Comparison of Appendix VIII and ENIQ

Similar documents
COMPARISON BETWEEN NDE QUALIFICATION STANDARDS AND PRACTICES IN DIFFERENT COUNTRIES. P. Jardet, M. Dib, EDF Qualification Body, France

EUROPEAN COMMISSION DG-JRC Institute for Advanced Materials ISSUE 2. December 1999 ENIQ Report nr. 12 EUR EN

Inspection Qualification II

Standard compliance - NDT performance demonstration in the CANDU industry

THE EUROPEAN NETWORK FOR INSPECTION AND QUALIFICATION (ENIQ)

Controlling the risk due to the use of gamma sources for NDT First feedback from the deployment of replacement NDT Techniques

Challenges of Hungarian nuclear NDT regarding existing plants and new-builds

The Need For Technical Justification and Performance Demonstrations

Implementation of a Performance Evaluation System for Nondestructive Testing Methods Daniel Algernon, Sascha Feistkorn and Michael Scherrer

Some Critical Remarks from German Chemical Industry on Certification and Accreditation in NDT

Nondestructive testing course structure

ENIQ RECOMMENDED PRACTICE 2

4th International CANDU In-service Inspection Workshop and NDT in Canada 2012 Conference, 2012 June 18-21, Toronto, Ontario

Phased Array Ultrasonic Testing

AIRWORTHINESS ADVISORY CIRCULAR

BEST PRACTICE IN THE APPLICATION OF NDT AN UPDATE J. M. Farley Mitsui Babcock, Renfrew, UK

Reliable Flaw Detection. Fast Inspection Times. High quality non-destructive testing services tailored for all your needs.

Reliability Studies, a Tool in the Development of Techniques for NDT of the Canister for the Swedish Spent Nuclear Fuel

The Volume POD as an Optimisation Tool of Multiple NDT Inspections of Complex Geometries

Achieving Effective and Reliable NDT in the Context of RBI

Nondestructive Testing (NDT) users Bill of Right. Morteza K. Jafari, P.E.

This course is designed to meet over a period of 14 weeks, 1 meeting per week, and 3 hours per meeting in a combined lecture-lab meeting.

The NDT Quality Infrastructure for Best Practice

RELIABILITY of NON-DESTRUCTIVE TESTING RESULTS of WELDED JOINTS

The Current Situation and Outlook of the NDT Personnel Certification in China

MDEP VICWG-02. Technical Report

Qualification of Manual Phased Array Ultrasonic Techniques for Pipe Weld Inspection in Nuclear Power Plants

Research Centre Rez. NDT Laboratory - SUSEN

Stress Corrosion Cracking Test Pieces for Inspection Qualification and NDT Development

Are we ready for the switch over?

AN EMPLOYERS GUIDE TO NDT PERSONNEL CERTIFICATION

Updating WENRA Reference Levels for existing reactors in the light of TEPCO Fukushima Dai-ichi accident lessons learned

EFNDT Guidelines on the overall NDT quality system in Europe

Global Inspection and Certifications (GIC) (Learn Today Lead Tomorrow)

19 th World Conference on Non-Destructive Testing Manfred JOHANNES 1. 1 More info about this article:

Quantification of the reliability of flaw detection (NDT) using probability of detection (POD) based on synthetic data

API. Generic Procedure. for the. Ultrasonic Examination. Ferritic Welds

The scheduled dates for NDT Inspector Certification Examination are as below:

MANUAL PHASED ARRAY ULTRASONIC TECHNIC FOR PIPE WELD INSPECTION IN NUCLEAR POWER PLANTS

An ISO 9001:2008 Certified Company

1. SCOPE ELIGIBILITY EXAMINATION CONTENT RENEWAL & RECERTIFICATION PROCEDURE ESSENTIAL READING...

ISO and the Delivery of Competent NDT Services

AMERICAN SOCIETY FOR NONDESTRUCTIVE TESTING Recommended Practice No. SNT-TC-1A June 1980 Edition

The Electronic Newsletter of The Industrial Refrigeration Consortium Vol. 11 No. 4, 2011

Ultrasonic Testing (UT) Level 2

Developments in Radiographic Inspection Methods

We are providing Level I, II Training and Certification as per Recommended practice SNT TC 1A 2006 in the following NDT Methods.

ISO INTERNATIONAL STANDARD. Steel products Employer's qualification system for non-destructive testing (NDT) personnel

ANSI/ASNT CP-189 Inquiries

A CONTRIBUTION TO QUANTIFYING THE SOURCES OF ERRORS IN PAUT

SECTION A GENERAL A1. a. Identify types of nondestructive testing performed at the facility being audited:

Non-destructive Testing ISO/IEC Application Document. Issue Date: October 2017

ISO INTERNATIONAL STANDARD. Non-destructive testing Qualification of personnel for limited applications of non-destructive testing

VMI Conference San Antonio, Texas

Certification of NDT Personnel: Current Perspective & Future Outlook

Magnetic Testing (MT) Level 2

Kiwa Inspecta. Kiwa Inspecta. Trust Quality Progress

Education of specialists

CONTENTS. Introduction Scope External References Terms and Definitions Abbreviations... 7

Developing a Phased Array Ultrasound Training Program. By: Mick Patino,

NON-DESTRUCTIvE TESTING. full SCOPE Of INTEGRATED NDT SERvICES

SOUTHERN AFRICAN INSTITUTE OF WELDING. Non Destructive Testing (NDT) Course Syllabus & Programme

Nature of Work. Working Conditions

NDT PERFORMANCE DEMONSTRATION USING SIMULATION

LIQUID PENETRANT EXAMINATION PROCEDURE

Radiant NDT Services

Marine Composite Certification Group

COWLEY COLLEGE & Area Vocational Technical School

Advanced Radiographic Testing (RT) Level 2.9

API. Defined Procedure. for. Ultrasonic Thickness Measurement API-UT-21

INNOVATIVE NDT SOLUTIONS RELIABILITY & INTEGRITY

PCN-ISO GEN Requirements for the Qualification of personnel for Limited Applications of Non-destructive Testing

Workshop Information IAEA Workshop

Field inspection of Phase-Array ultrasonic for polyethylene electrofusion joints

NANDTB-F012 Rev 0 Audit Checklist

PCN/AERO A0 Issue 3 IMPLEMENTATION DATE: 1 ST AUGUST 2014 PCN QUALIFICATION AND CERTIFICATION OF NDT PERSONNEL FOR THE AEROSPACE MULTI-SECTOR

A General Survey on NDT in the Chemical Industry

Safety Requirements for Long Term Operation or Ageing Aspects and for Design, Construction and Operation of New Nuclear Power Plants

ISO INTERNATIONAL STANDARD. Steel products Employer's qualification system for non-destructive testing (NDT) personnel

Nondestructive Testing Procedure: Liquid Penetrant Testing

National Certification Board

Harmony of NDT Training

Global Inspection and Certifications (GIC) (Learn Today Lead Tomorrow)

Non-Destructive Test (NDT) and Non-Destructive Evaluation (NDE) Requirements

THE EUROPEAN FEDERATION FOR NON DESTRUCTIVE TESTING RILOT PROJECT CERTIFICATION AND ACCREDITATION OF UKRAINIAN NDT LABORATORIES (The 1 st stage

Procedure. Identify all possible radiation hazards.

PART 1c: Time of Flight Diffraction Ultrasonic Inspector (TOFD) of Welds in Ferritic and Non-Ferritic Materials, Levels 1, 2 and 3

Miroslav Žamboch February 2015, IAEA,Vienna

Eddy Current Testing Level 1

Reliability Analysis of the Phased-Array Ultrasonic System used for the Inspection of Friction Stir Welds of Copper Canisters

IAEA s Technical Safety Review Services

PCN QUALIFICATION AND CERTIFICATION OF NDT PERSONNEL FOR THE AEROSPACE MULTI-SECTOR

Other Major Component Inspection II

The UDT-CERT system as a nationally recognized system for the certification of competence of NDT personnel

Non Destructive Testing Services

Guidelines for the Qualification and Certification of Penetrant Testing Personnel

Development of Indigenous Ultrasonic Data Acquisition and Recording System for ISI of Pressure Tubes of PHWR

Misconceptions about NDT Workmanship Acceptance Criteria for Quality Control

COWLEY COLLEGE & Area Vocational Technical School

Transcription:

Comparison of Appendix VIII and ENIQ Ladislav Horáček ladislav.horacek@ujv.cz NUCLEAR CODES & STANDARDS WORKSHOP July 7-8, 2014

ENIQ network changed to NUGENIA TA8 TA1: Safety and risk of NPPs TA2: Severe accidents TA3: Core and reactor operation TA4: System and component integrity TA5: Fuel, waste and decommissioning TA6: Innovative LWR design & technology TA7: Harmonisation TA8: Inspection Qualification and Risk-Informed Inspection Planning (ENIQ) 1

ENIQ network changed to NUGENIA TA8 ENIQ European Network for Inspection and Qualification was integrated as Technical Area 8 (TA8) into NUGENIA NUGENIA is an International non-profit-making association, according to 1921 Belgian law, established in Brussels on 14 Nov. 2011. TA8: Inspection Qualification and Risk-Informed Inspection Planning (ENIQ) Group Qualification (TGQ) 8.2 Task Group Risk (T8.1 Task GR) 8.3 TG Inspection Qualification Bodies (TG IQB) http://www.nugenia.org/ 2

Comparison Basic information ASME SECTION XI APPENDIX VIII PERFORMANCE DEMONSTRATION (PD) FOR ULTRASONIC EXAMINATION SYSTEMS A part of ASME Code Section XI - Rules for In-service Inspection of Nuclear Power Plant Components Mandatory Appendix - written in prescriptive way EUROPEAN METHODOLOGY FOR QUALIFICATION OF NON-DESTRUCTIVE TESTING (EMQ) Recommended Guideline for Qualification of Nondestructive testing In general applicable to all NDE methods 3

Comparison Basic information (cont.) ASME SECTION XI APPENDIX VIII PERFORMANCE DEMONSTRATION (PD) FOR ULTRASONIC EXAMINATION SYSTEMS Devoted to ultrasonic examination only PD of inspection procedure, equipment and personnel performed altogether (not a separate PD of inspection procedure) EUROPEAN METHODOLOGY FOR QUALIFICATION OF NON-DESTRUCTIVE TESTING (EMQ) Applied mainly for volumetric examinations (UT, ET, RT) Qualification of inspection procedure and equipment separate from personnel qualification 4

5 Comparison Main Principles and rules ASME Section XI Appendix VIII provides requirements (reqs) for ultrasonic examination procedures, equipment, and personnel used to detect and size flaws. Each organization that performs ultrasonic examinations shall qualify its procedures, equipment, and personnel in accordance with this Appendix. PD reqs apply to personnel who size flaws or detect, record, or interpret indications in welds or components. ENIQ/NUGENIA TA 8 Qualification of an inspection means assessment of NDT system, composed of combination of NDT procedure, equipment and personnel. Considered as the sum of the two items: Technical justification (TJ) and Practical trials (PT - blind or open). The mix of TJ and PT must be judged separately, use of TJ highly recommended in all cases.

Comparison Qualification Procedure (QP) ASME Section XI Appendix VIII Appendix VIII written in a detailed prescriptive way necessary to be followed Written Qualification procedure described in ENIQ/NUGENIA TA8 can be regarded as useless ENIQ/NUGENIA TA 8 Part of Qualification Dossier as a written agreement between the involved parties on the qualification approach required. In the qualification procedure is described the way the qualification will be implemented in practice. QP should contain, at least: objectives of the inspection qualification, qualification level, the way the TJ and IP will be assessed, details of how the practical OT/BT will be conducted, details of the qualification OT pieces, the way the results of the qualification will be evaluated. 6

Comparison Inspection procedure (IP) ASME Section XI Appendix VIII Examination procedure is not qualified as a separate item Provided for PD of examination procedure, equipment and personnel ENIQ/NUGENIA TA 8 Initial IP is a part of qualification input data. IP can be optimized using practice test pieces and the results obtained can be used in the TJ. Only qualified IP and equipment can be used for Personnel qualification 7

Comparison Technical justification (TJ) ASME Section XI Appendix VIII Not required within PD Sometimes used within the preparation for PD in a similar way like within ENIQ/NUGENIA TA8 ENIQ/NUGENIA TA 8 TJ involves assembling all the supporting evidence for inspection capability like results of capability evaluation exercises, feedback from site experience, applicable and validated theoretical models, physical reasoning and may include practical trials using deliberately defective test pieces. TJ can contain: measurements on practice/development test pieces, physical reasoning, feedback from field experience, the results from mathematical models, relevant RRT round trials, laboratory studies, description of the equipment, experimental development results. 8

Comparison Open Practical Trials (OT) ASME Section XI Appendix VIII OT are not required as a mandatory component of PD OT, if any, are performed by the inspection vendor usually on site specific specimens under site supervision as a site specific training just before the job ENIQ/NUGENIA TA 8 OT should be performed for the NDT procedure, where a sufficient demonstration of its adequacy through technical justification is not possible. Qualification of Personnel, using qualified NDT procedures and equipment, should be performed through one or any combination of the following: a) certification through a national NDT personnel certification scheme, b) theoretical and/or open practical examination, c) blind trials 9

Comparison - Blind Practical Trials (BT) ASME Section XI Appendix VIII All PD tests are blind - Flaw location and specimen identification shall be obscured to maintain a "blind test. PD tests are performed on Detection specimens and Sizing specimens ENIQ/NUGENIA TA 8 Blind practical trials are not mandatory, can be part of QP Qualification of Personnel (QP), using qualified NDT procedures and equipment, should be performed through one or any combination of the following: a) certification through a national NDT personnel certification scheme, b) theoretical and/or open practical examination, c) blind trials 10

Thank you for your attention www.ujv.cz 11