Water Determination in Ethanol by Karl Fischer Titration

Similar documents
Acetic Acid in Vinegar by Acid/Base Titration

Hydrogen Peroxide Determination by Redox Titration

Sodium Chloride Content in Ketchup by Precipitation Titration

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

Fundamentals of the Volumetric Karl Fischer Titration with 10 Selected Applications. METTLER TOLEDO DL31/DL38 Titrators Application brochure 26

HI Total Acidity Mini Titrator for Water Analysis

EasyPlus Titration. Food & Beverage Analysis Made Easy Swiss Precision for Your Analysis

Determination of the acid value (AV) Application Bulletin 200/3 e. Electrodes Solvotrode easyclean

Determination of Langelier Index in Water

Determination of Vitamin C in Fruit Juices

METTLER TOLEDO Titrators. 30 Selected Applications Application brochure 12

Biodiesel Fundamentals for High School Chemistry Classes. Laboratory 3: Determination of the Acid Number of Vegetable Oils by Titration

Titrimetric Determination of Hypo Index, Thiosulfate, and Sulfite in EASTMAN Color Films, Process ECN-2 Fixer

Total Acid Number in petroleum products by automatic titration

3 To gain experience monitoring a titration with a ph electrode and determining the equivalence point.

Experiment: Iodometric Titration Analysis of Ascorbic Acid Chem251 modified 09/2018

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

HI Total Alkalinity Mini Titrator for Water Analysis

Free and Total Sulfur Dioxide (SO 2. ) in wine (Ripper method) by automatic titration

HI Total Alkalinity Mini Titrator for Water Analysis

Determining the Molecular Mass of an Unknown Acid by Titration

Pt-electrode with temperature sensor, Intellical MTC695

Application Note. Determination of the Acid Number (TAN) Tips and Tricks

Take an initial volume reading and record it in your. 11/17/2014 ChemLab - Techniques - Titration

Method (6 to 1000 µg/l Chlorine as Cl 2 ) Digital Titrator

Titration DL22 F&B Food & Beverage Analyzer

CORESTA Recommended Method No. 56

White Paper. Thermometric Titration of Acid Number According to ASTM D8045

COLE-PARMER LABORATORY SURFACTANT ION ELECTRODE INSTRUCTION MANUAL

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

PtPt-electrode with temperature sensor, Intellical MTC695

2. is a set of principles intended to help sustain a habitable planet.

Thiols (mercaptans) in Fuels (ASTM D )

Determination of the total acid number in petroleum products

Strength of Vinegar by Acid-Base Titration

SAC 17 Queen Mary University of London

EXPERIMENT 2: ACID/BASE TITRATION. Each person will do this laboratory individually. Individual written reports are required.

PROCEDURE. TITLE: Bedside Glucose Monitoring PC Laboratory. Issuing Department: Clinical Director Signature: Departments Involved:

HI FREE & TOTAL SULFUR DIOXIDE MINITITRATOR for wine analysis

888/890 Enter the Titrando world

10 th International Junior Science Olympiad, Pune, India. Experimental Tasks. Examination Rules: Task: C Tomato (6 marks for this task)

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

Determination of the total acid number in petroleum products

TRATION: ANALYSIS OF SODIUM HYDROXIDE

Application Note No. 112/2013 Nitrogen & urea determination in cosmetics KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376: Nitrogen and

Chemistry 201 Laboratory Fall 2006 page 1 of 4

WaveTrace TM Karl Fischer reagents. Achieve the best results in your moisture analysis

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

Determination of acid number in diesel engine oil

Application Note No. 113/2013 Nitrogen & protein determination in dry pet food KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376:

ebook Best practices using automated titrators Achieving speed and accuracy in your lab

Free Chlorine. Based on 4500-Cl D. in Standard Methods for the Examination of Water and Wastewater DOC

TRATION: ANALYSIS OF SODIUM HYDROXIDE

Chemistry Iodometric Determination of Vitamin C

#20 Separation of Alcohols Using Gas Chromatography

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Task: B Milk (20 marks for this task) Examination Rules:

25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual

May 13, 2017 Data Back Ban of Artificial Trans Fats

COLE-PARMER REPLACEABLE MEMBRANE SCIENTIFIC SURFACTANT ION ELECTRODES INSTRUCTION MANUAL

QUICK START GUIDE HI 903 KARL FISCHER VOLUMETRIC TITRATOR. Revision 1.0

Agilent 1260 Infinity Analytical Hybrid SFC/UHPLC system

IODINE AFFINITY. 3. Extraction Shells: Paper, 80 x 22 mm (Note 1)

EXPERIMENT. Titration of the Weak Acid Potassium Hydrogen Phthalate (KHP)

Application Note No. 110/2013 Nitrogen & protein determination in corn, flour and soy KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376:

Technical Report. E-Liquid Preliminary Proficiency Study

Experiment 6: STANDARDIZATION OF A BASE; MASS PERCENT OF AN ACID

Titration of Synthesized Aspirin A continuation of the aspirin synthesis lab

Application Note No. 107/2013 Nitrogen & protein determination in beer and malt KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376:

Determination of total caustic, total soda and alumina in Bayer process liquors with 859 Titrotherm

Lipidomic Analysis by UPLC-QTOF MS

NF-κB p65 (Phospho-Thr254)

22 Bicozamycin (Bicyclomycin)

Chemistry 212. Experiment 3 ANALYSIS OF A SOLID MIXTURE LEARNING OBJECTIVES. - learn to analyze a solid unknown with volumetric techniques.

Potentiometric determination. Application Bulletin 125/3 e. Branch General analytical laboratories; water analysis; beverages

Application Note No. 108/2013 Nitrogen & protein determination in beer and malt KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376: Nitrogen

Traceability of breath alcohol concentrations in Romania

VarseoWax CAD/Cast GEBRAUCHSANWEISUNG INSTRUCTIONS FOR USE MODE D EMPLOI INSTRUCCIONES DE USO ISTRUZIONI PER L USO Partners in Progress

Determination of Total Hardness in Water by Automatic Titration

Application Bulletin

Institute of Science & Technology in Medicine Control of Substance Hazardous to Health COSHH assessment

Carbohydrates. Objectives. Background. Experiment 6

Biodiversity Study & Biomass Analysis

FIGURE 1. The structure of glucose and ascorbic acid (vitamin C). FIGURE 2. Reduced and oxidized forms of ascorbic acid.

OH 102. Communication Training. Pickle Research Campus CEER, Building 133 Labs: 1.502A&B, 1.504, 1.704

Hardness by EDTA Titration

Page 1/5. Harris Hematoxylin Harris Hematoxylin without Mercuric Chloride N/A N/A

LAB: DIFFUSION ACROSS A SELECTIVELY PERMEABLE MEMBRANE

Determination of sodium in margarine manufacture

EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B

Hardness (Total & Calcium) Test Kit TK4040-Z 1 drop = 2 or 10 ppm as CaCO 3

Experiment 3. Potentiometric Titration Using a ph Electrode. information necessary for both purposes by monitoring the ph of the solution as the

PROTE NITROGEN / PROTEIN by COMBUSTION

Teacher Demo/Student Activity: Limit to Cell Size

SAFETY GOGGLES MUST BE WORN AT ALL TIMES!

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

What is worse, cigarettes or narghile?

EASI-EXTRACT BIOTIN Product Code: P82 / P82B

Transcription:

Water Determination in Ethanol by Karl Fischer Titration Background Water content is an important parameter for a wide range of processes (e.g. chemical reactions) and products (e.g. food products). Its determination in raw and finished products is therefore a standard method in many laboratories, often by means of Karl Fischer titration. This method is based on a selective reaction between water and the Karl Fischer reagent, ideally using an automated titrator. It has excellent precision, accuracy and selectivity, which can be achieved with a short analysis time for water contents from 100 % to a few ppms. Karl Fischer is the method recommended by international standards for different matrices in liquid, solid and even gaseous samples. Reaction CH 3 OH + SO 2 + 3 C 3 H 4 N 2 + I 2 + H 2 O (C 3 H 4 N 2 H) SO 4 CH 3 + 2 (C 3 H 4 N 2 H)I From this reaction it can be seen that water (H 2 O) reacts with iodine (I 2 ) - in the presence of sulfur dioxide (SO 2 ), a base (C 3 H 4 N 2, imidazole) and methanol (CH 3 OH) - attaining 1:1 stoichiometry. Safety Karl Fischer titrant and solvent are toxic. Remember to follow general laboratory safety procedures. Always wear a lab coat, gloves and protective goggles during this workshop. Tasks 1. Titrant concentration determination: Use an automated titrator to determine the concentration of the Karl Fischer onecomponent titrant with a nominal concentration of 5 mg/ml. Fill the titration vessel with 50 ml of dry methanol and start the titrant concentration determination. The pretitration is performed automatically; the titrator switches to standby mode as soon as it is finished. Wait for a low and stable drift (< 25 µg/min). Rinse a 10 ml syringe with 2 ml of certified water standard (10 mg/g) and then aspirate ca. 5 ml of this standard. Start the concentration determination on the titrator and inject about 1 ml of the water standard into the titration vessel. Use the back-weighing technique to determine the amount of sample injected: 1. Place the syringe containing the water standard on the balance. 2. Tare. 3. Start the concentration determination and inject the sample into the titration vessel through one of the vessel stoppers. Workshop 4 1 Powered by METTLER TOLEDO

4. Place the syringe again on the balance. The amount of sample added into the titration vessel will be given on the balance as the negative weight. 5. Enter the weight into the titrator. Wait until the titration is finished. The result will be displayed on the screen (or printed out). Repeat the concentration determination two times. The mean value, standard deviation (s) and relative standard deviation (srel) will be calculated automatically by the titrator. Calculate the optimal sample size from the estimated water content of the ethanol sample, such that about 20 mg of water are injected into the titration vessel. Start the titration. Note that this is a water content determination and not a concentration determination. Wait until the pretitration is finished and the drift in the standby mode is low and stable. Rinse the syringe with 1 ml of sample and then aspirate the amount of sample needed. Start the measurement and add the calculated amount of sample. Use the back-weighing technique as described above to determine the amount of sample injected. Perform this analysis at least three times. The results (water content in %) mean value, standard deviation (s) and relative standard deviation (srel) will be displayed on the screen (or printed out). Stop the titration and remove the solvent from the vessel. Waste disposal: Collect all solutions and dispose of as organic solvents. Workshop 4 2 Powered by METTLER TOLEDO

Water Determination in Ethanol by Karl Fischer Titration Equipment - 1x Analytical balance - 1x Mettler-Toledo Easy KFV titrator with 10 ml burette, tubing, drying tubes, bottle heads and EasyPump for solvent replacement - 1x EG43-BNC ph Electrode - 1x Magnetic stirrer bars Chemicals The quantities below were roughly estimated for 5 concentration determinations and 5 water content determinations. - 200 ml of Karl Fischer one-component titrant 5 mg/ml - 100 ml of dry methanol (for Karl Fischer titration) - 10 ml of certified water standard 10mg/g - 10 ml of ethanol containing about 1 % of water as sample - 100 g molecular sieve Preparation - Install the titrator and fill all drying tubes with fresh (or regenerated) molecular sieve. - Rinse the burette of the automatic titrator with titrant at least twice to dispel any air bubbles trapped in the burette and tubing. Comments - This method may be slightly adapted depending on the water content of the sample. Teacher Information 3 Powered by METTLER TOLEDO

Solution 1. Concentration determination: Expected result: The concentration of the titrant should be between 4.5 mg/ml and 5.5 mg/ml. Use fresh titrant if the concentration lies outside this limit. The optimum sample size of the titrant can be calculated by using the following formula: m opt m = R 10 m: Optimum sample size (in g) m opt : Optimum amount of water which should be put into the titration vessel (in mg, here: 20 mg) R: Expected water content for the sample (in %, here: 1 %) 10: Unit conversion factor from % to mg/g (in mg/(g %)) Expected result: Depending on the sample the water content should be around 1 %. Teacher Information 4 Powered by METTLER TOLEDO

Example 1. Concentration determination: Three concentration determinations were performed and the following titrant concentrations (c) were obtained for the three samples (m: Sample size): Nr. m c 1 2.136 g 5.1975 mg/ml 2 1.783 g 5.2089 mg/ml 3 2.234 g 5.2175 mg/ml The statistics for these results are: Mean: 5.2080 mg/ml s: 0.0100 mg/ml srel: 0.19 % The optimum sample size was calculated using the following formula, estimating a water content of 1 % and an optimum amount of water of 20 mg. It is expected that around half of the burette volume will be used for this amount of water. m = m opt R 10 = 20 mg 1 % 10 mg = 2 g g % The calulated sample size was used to measure the water content of ethanol three times. The following water contents (R) and statistics were obtained: Nr. m R 1 2.136 g 0.8753 % 2 1.783 g 0.8739 % 3 2.234 g 0.8761 % Mean: 0.8751 % s: 0.0011 % srel: 0.13 % Teacher Information 5 Powered by METTLER TOLEDO