CORAIL HIP SYSTEM DESIGN RATIONALE

Similar documents
The science of simplicity

simplicity THE SCIENCE OF DESIGN RATIONALE

Optimizing function Maximizing survivorship Accelerating recovery

Surgical Technique r5.indd 1 12/8/10 10:36 AM

Optimum implant geometry

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Bone Preservation Stem

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

Optimum implant geometry

Approach Patients with CONFIDENCE

Optimum implant geometry

Approach Patients with Confidence

This publication is not intended for distribution in the USA.

RECLAIM REVISION HIP SYSTEM

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Tissue Sparing. DEsign Rationale

Surgical Technique. Hip System

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

Approach Patients with Confidence

Integra. Titan Modular Shoulder System, 2.5

HIP SYSTEM SURGICAL TECHNIQUE

Progeny Hip Stem. Surgical Protocol and Product Specifications

Metha Short Hip Stem System

AML Hip System. Design Rationale/ Surgical Technique

Featuring. Technology. Product Rationale

Tri-Lock Bone Preservation Stem

MetaFix. Cementless Total Hip Replacement Surgical technique

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

DESIGN RATIONALE AND SURGICAL TECHNIQUE

CORAIL Upgrade Kit. Surgical Technique

SHOULDER EXTRACTION INSTRUMENTS

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

HIP CONTINUUM OF CARE. Trauma and Joint Reconstruction Hip Portfolio

Revision. Hip Stem. Surgical Protocol

SURGICAL TECHNIQUE. Entrada Hip Stem

Overview of Cementless Stems in Total Hip Arthroplasty Review Paper on the Corial Style Stem

HELIOS h i p s y s t e m

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

ACETABULAR CUP SURGICAL TECHNIQUE

CORAIL UPGRADE KIT. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

MetaFix Cementless Total Hip Replacement Product overview

Bone Conserving Hip Replacement Surgical technique

Surgical Technique. *smith&nephew POLARSTEM Cementless Stem System

Hip Fracture Management. Product overview

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Move Ahead with Confidence. Hip Replacement Solutions from DePuy Orthopaedics

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

TOTAL HIP REPLACEMENT:

Knee Revision. Portfolio

Bone Bangalore

TriboFit Hip System. Issue 3 - August 2013 English

ARTICUL/EZE Mini Taper. C-STEM AMT Hip. Design Rationale & Surgical Technique

Continuing the Tradition. VerSys Heritage Hip System

CORAIL Hip System. Product Rationale and Surgical Technique

CORAIL Hip System. Product Rationale and Surgical Technique

Product Rationale. Where Strength and Modularity Connect

Arcos Modular Femoral Revision System

S U R G I C A L T E C H N I Q U E

EXTENDED TROCHANTERIC OSTEOTOMY SURGICAL TECHNIQUE FPO EXTENSIVELY COATED FIXATION

3.5 mm Clavicle Hook Plates

)501( COPYRIGHT 2018 BY THE ARCHIVES OF BONE AND JOINT SURGERY

Design Rationale. ECHELON Primary Hip System

Furlong H-A.C. THR System

TaperFill. Surgical Technique

Cementless Tapered Femoral Stem Surgical technique

Duraloc CONSTRAINED LINER

Taperloc Complete Hip System. Surgical Technique

This publication is not intended for distribution in the USA. Product rationale and surgical technique

CAUTION Federal law (USA) restricts this device to sale, by or on the order of a physician.

MetaFix. Cementless Total Hip Replacement Surgical technique

UTF Stem. reduced. Surgical Protocol

S h o u l d e r Solutions by Tornier C o n v e r T i b l e S h o u l d e r S y S T e m

Femoral Revision Algorithm. A practical guide for the use of the CORAIL Hip System in femoral revision surgery

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

Specifications guide ECHELON. Hip System

EVOLVING OUR HERITAGE, MEETING YOUR NEEDS. Surgical Technique

Cementless Tapered Femoral Stem Surgical technique

PLR. Proximal Loading Revision Hip System

3.5 mm Locking Attachment Plate

CORAIL Hip System. Clinical Summary

9800 Metric Blvd. Austin, Texas

CPCS. Training Manual. Collarless Polished Cemented Stem

Avenir Femoral Hip System

FLH /11

CONSENSUS ORTHOPEDICS INC. UNISYN HIP SYSTEM

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM

Comprehensive Reverse Shoulder System

Hip Resurfacing System

CONSENSUS ORTHOPEDICS INC.

PINNACLE REVISION CUP SYSTEM

HP KNEE EXTRACTION Instrumentation. Product Overview

THE P.F.C. SIGMA FEMORAL ADAPTER. Surgical Technique

Transcription:

CORAIL HIP SYSTEM DESIGN RATIONALE

THE SCIENCE OF SIMPLICITY The advanced features of the CORAIL stem, and its bone-preserving surgical technique, have made it a great choice for minimally invasive hip surgery. More than twenty years ago, we began a revolution with the use of HA in orthopaedics. Today we face an exciting new era, and we look forward with confidence in sharing continued success with the world s orthopaedic community. ARTRO Group - Design Surgeon Team, Clinique d Argonay International Visitation Centre - Annecy, France US Surgeon Team James Caillouette, MD; Charles R. Clark, MD; Mark Froimson, MD; Jonathan Garino, MD; William Lanzer, MD; Joel Matta, MD; Sam Sydney, MD

1 2 3 4 5 1 Three offset options to restore hip biomechanics 2 Tapered neck geometry and Articul/eze taper designed to increase range of motion 6 3 Low-profile lateral shoulder design enables easy insertion in reduced incision techniques, including the anterior approach. 4 Available in collared or non-collared options 7 5 6 Step geometry converts hoop stresses to compressive loads Vertical/horizontal grooves provide rotational and axial stability 7 Proprietary HA coating I ve used the CORAIL since 1998 and with its easyto-use surgical technique, choose to use it on many types of patients, including those with osteopenia and in hemiarthroplasty cases for femoral neck fracture treatment. Jonathan Garino, MD - Philadelphia, Pennsylvania

Proven Fixation CORAIL stepped geometry is oriented to minimize shear forces and maximize compression loading in host cancellous bone. Proximal trapezoid cross section resists axial/torsional stresses and promotes initial stability. Distal quadrangular cross section provides rotational stability without cortical contact 4 DePuy Synthes Joint Reconstruction CORAIL Design Rationale

1 year post-op 16 years post-op LONG-TERM SURVIVORSHIP 98.3% Survivorship at 10 and 14 years 1 98.9% Survivorship in 100 consecutive cases at 8 years 2 97.0% Survivorship in 5,456 cases at 15 years 3 I find the CORAIL stem design and HA coating provides initial stability for my patients. William Lanzer, MD - Seattle, Washington Design Rationale CORAIL DePuy Synthes Joint Reconstruction 5

Enhanced Biomechanics +7 mm +7 mm Stem Axis Stem Axis -5 mm Corail STD Corail High Offset 135 STD 135 High Offset Corail Coxa Vara Corail STD 135 STD 125 Coxa Vara COLLARLESS STEM OPTIONS Standard and high offset collarless stem options enable femoral offset restoration and soft-tissue tensioning. High offset collarless option adds +7 mm of direct lateralization to restore hip biomechanics in a wider range of patients. COLLARED STEM OPTIONS Collared stems are available in both standard and coxa vara offset to control subsidence and add rotational stability in patients with osteopenic bone. Coxa vara collared neck option offers an increased offset and varus neck angle for femoral restoration and proper soft-tissue tensioning of varus neck angled patients. 6 DePuy Synthes Joint Reconstruction CORAIL Design Rationale

NECK ENHANCEMENTS Narrowed anterior-posterior neck dimensions and optimized Articul/eze taper increase range of motion and reduce risk of mechanical impingement. Articul/eze 12/14 taper is fully captured by all nonskirted Articul/eze heads, eliminating the creation of a false skirt due to trunnion protrusion. I use the CORAIL because of its ease of implantation and long track record. Used with the PINNACLE Acetabular Cup System, it lets me select multiple options in order to optimize hip biomechanics in my patients. Charles R. Clark, MD - Iowa City, Iowa Polished neck is designed to generate less wear debris secondary to prosthetic impingement. Design Rationale CORAIL DePuy Synthes Joint Reconstruction 7

Bone Preserving Philosophy COMPACTION BROACHING A philosophy of respecting and preserving patient anatomy, biology and physiology are key to the CORAIL success. Compressing and compacting the cancellous bone during the broaching process maintains the medullary canal endosteum, preserving blood supply to the bone and the bone/implant interface. Compaction broaching creates an excellent bone/implant contact ratio and high pullout strength, and it increases prosthetic torsional stability. Compaction broaching preserves the blood supply to promote healing and growth of bone around the implant, and this technique has shown excellent longterm survivorship. 2,3 8 DePuy Synthes Joint Reconstruction CORAIL Design Rationale

18 years post-op Compaction broaching coupled with CORAIL creates silent hip replacement. We haven t seen any adverse, long-term radiographic changes. James Caillouette, MD - Newport Beach, California I find the CORAIL stem and instrumentation facilitate ease of insertion using an anterior approach. Joel Matta, MD - Los Angeles, California Design Rationale CORAIL DePuy Synthes Joint Reconstruction 9

Heritage The fully HA-coated CORAIL Total Hip System can be used in a variety of types and sizes of femora. 4 Pre-op 4 years post-op Pre-op 5 years post-op Pre-op 5 years post-op Type A: Champagne Flute Type B: Proportional Shape Type C: Stovepipe I find it to be reproducible and easy to implant, and use it on many different types of patients. Sam Sydney, MD - Baltimore, Maryland After independently reviewing the ARTRO Group CORAIL data in 1998, I decided to try the CORAIL stem. I m pleased with the results and now use it on many types of patients. Mark Froimson, MD - Cleveland, Ohio 11 DePuy Synthes Joint Reconstruction CORAIL Design Rationale

Surgical Technique Step 1: Neck Osteotomy Step 2: Femoral Canal Preparation Step 3: Offset Selection & Head Trialing Step 4: Femoral Component Insertion Design Rationale CORAIL DePuy Synthes Joint Reconstruction 11

Essential Product Information - CORAIL AMT Hip Important This Essential Product Information sheet does not include all of the information necessary for selection and use of a device. Please see full labeling for all necessary information. Indications The CORAIL AMT Hip Prosthesis is intended for use in total hip arthroplasty and is intended for pressfit (uncemented) use. Total hip arthroplasty is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. Total hip replacement is indicated in the following conditions: 1. A severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. Avascular necrosis of the femoral head. 3. Acute traumatic fracture of the femoral head or neck. 4. Failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, or total hip replacement. 5. Certain cases of ankylosis. HA coated stems are indicated for cementless use only. Contraindications The following conditions are contraindications for total or hemi-hip replacement: 1. Active local of systemic infection. 2. Loss of musculature, neuromuscular compromise or vascular deficiency in the affected limb rendering the procedure unjustified. 3. Poor bone quality, such as osteoporosis, where, in the surgeon s opinion, there could be considerable migration of the prosthesis or a significant chance of fracture of the femoral shaft considerable migration of the prosthesis or a significant chance of fracture of the femoral shaft and/or the lack of adequate bone to support the implant(s). 4. Charcot s or Paget s disease. 5. For hemi-hip arthroplasty, any pathological condition of the acetabulum, such as distorted acetabuli with irregularities, protrusion acetabuli (arthrokatadysis), or migrating acetabuli, that would preclude the use of the natural acetabulum as an appropriate articul surface for the hemi-hip prosthesis. Warnings and Precautions HA coated implants must not be implanted with cement When changing the head on a femoral stem which is still in place, it is essential to use a metal-metal interface. For some stems, head offset Warning notices are visible on labels to limit the maximum offset used for the head. For the Corail Revision stem, the maximum offset used for the head is limited to 13mm. Adverse Events The following are the most frequent adverse events after hip arthroplasty: change in position of the components, loosening of components, wear or fracture of components, dislocation, infection, peripheral neuropathies, tissue reaction References: 1. Vidalain JP. CORAIL Stem Long-Term Results based on the 15-Years ARTRO Group Experience. Fifteen Years of Clinical Experience with Hydroxyapatite Coatings in Joint Arthroplasty, Ed. Springer, 217-224; 2004. 2. Rokkum M, Brandt M, Bye K, Hetland KR, Waage S, Reigstad A. Polyethylene wear, osteolysis and acetabular loosening with an HA coated hip prosthesis. A follow-up of 94 consecutive arthroplasties. J Bone Joint Surg Br. 1999;81(4):582-9. 3. Hallan, G, Lie SA, Furnes O, Engesaeter LB, Vollset SE, Havelin LI. Medium - and long-term performance of 11,516 uncemented primary femoral stems from the Norwegian arthroplasty register. The Journal of Bone and Joint Surgery. 2007:89-B:1574-80. 4. Chatelet JC, Setiey L. Long-term study of osteolysis around the hydroxyapatite-coated total hip arthroplasty without cement. British Editorial Society of Bone and Joint Surgery. 2004;86-B (supple I):39. Limited Warranty and Disclaimer: DePuy Synthes Joint Reconstruction products are sold with a limited warranty to the original purchaser against defects in workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed. WARNING: In the USA, this product has labeling limitations. See package insert for complete information. CAUTION: USA Law restricts these devices to sale by or on the order of a physician. Not all products are currently available in all markets. DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN 46582 T. +1 (800) 366-8143 www.depuysynthes.com DePuy Synthes Joint Reconstruction, a division of DOI 2013. All rights reserved. 0612-70-501 (Rev. 5) 3M 04/13