BioGraph Infiniti DynaMap Suite 3.0 for ProComp Infiniti March 2, SA7990B Ver 3.0

Similar documents
BioGraph Infiniti DynaMap Suite 3.0 for FlexComp Infiniti March 2, SA7990A Ver 3.0

Thought Technology Ltd.

MES 9000 MUSCULOSKELETAL EVALUATION SYSTEM

FUSE TECHNICAL REPORT

Software Overview. Thought Technology Ltd Belgrave Avenue, Montreal, QC H4A 2L8 Canada

Supplementary Figure S1: Histological analysis of kainate-treated animals

Overview. Page 1 of 9. Impedance Cardiography

Raw BP and Eight Hemodynamic Measurements Displayed in Real Time

Accuracy and validity of Kinetisense joint measures for cardinal movements, compared to current experimental and clinical gold standards.

Angular Measurements with BIOPAC Goniometers & Torsiometers

Hybrid EEG-HEG based Neurofeedback Device

Drug Free Stress Management using Biofeedback by

Stationary regime for Standing Wave Central Pattern Generator

EMG-Driven Human Model for Orthosis Control

11/18/13 ECG SIGNAL ACQUISITION HARDWARE DESIGN. Origin of Bioelectric Signals

FES Standing: The Effect of Arm Support on Stability and Fatigue During Sit-to-Stand Manoeuvres in SCI Individuals

Analysis of EMG Signal to Evaluate Muscle Strength and Classification

Processed by HBI: Russia/Switzerland/USA

Electroencephalograph EEG-9200J/K

Dynamic Surface Electromyography (SEMG) Information Sheet

BSL PRO Lesson H03: Nerve Conduction Velocity: Along the Ulnar Nerve of a Human Subject

Software Manual. Thought Technology Ltd Belgrave Avenue, Montreal, QC H4A 2L8 Canada

Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011

Human Brain Institute Russia-Switzerland-USA

Biopac Student Lab Lesson 20 SPINAL CORD REFLEXES Analysis Procedure. Rev

An electrocardiogram (ECG) is a recording of the electricity of the heart. Analysis of ECG

Hand of Hope. For hand rehabilitation. Member of Vincent Medical Holdings Limited

Extraction of Blood Vessels and Recognition of Bifurcation Points in Retinal Fundus Image

FT-302 Force Transducer

Instruction Manual No A. Goniometer PS-2138, PS-2137

Ergonomic Test of the Kinesis Contoured Keyboard

Experiment HM-7: Electromyogram (EMG) Activity in Antagonistic Muscles and Range of Motion

6 Correlation of Biometric Variables Measured with Biograph Infinity Biofeedback Device and Psychometric Scores of Burnout and Anxiety

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

Step-by-Step RECD Guide

How to use AutoFit (IMC2) How to use AutoFit (IMC2)

Early Learning vs Early Variability 1.5 r = p = Early Learning r = p = e 005. Early Learning 0.

Effect of Patellar Taping on Quadriceps Muscle of Knee Joint INTRODUCTION

Theta sequences are essential for internally generated hippocampal firing fields.

Development of an Electronic Glove with Voice Output for Finger Posture Recognition

General Treatment Equipment

The Effect of Analysis Methods and Input Signal Characteristics on Hearing Aid Measurements

Massage and Movement. Patrick A. Ward, MS CSCS LMT OptimumSportsPerformance.com

TMG - BMC LTD. Mirje 6 Tel: ( ) Ljubljana Fax: ( ) TENSIOMYOGRAPHY (TMG) MEASUREMENT RESULTS

Humerus. Ulna. Radius. Carpals

Corporate Medical Policy

An Overview of BMIs. Luca Rossini. Workshop on Brain Machine Interfaces for Space Applications

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 2, Issue 10, April 2013

Photic Output control using BrainMaster Atlantis

ELECTROMYOGRAM ANALYSIS OF MUSCLE FUNCTION INTRODUCTION

Cloud Condensation Nuclei Counter (CCN) Module

Nature Neuroscience: doi: /nn Supplementary Figure 1

MultiStim SWITCH and MultiStim SENSOR Setting the trend in nerve stimulation

Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive

Myoelectric control algorithm for robot assisted therapy: a hardware in the loop simulation study

BIOMECHANICAL ANALYSIS OF THE DEADLIFT DURING THE 1999 SPECIAL OLYMPICS WORLD GAMES

SleepSign System. FAQs User List Software Overview

SIGNATURE SERIES OLYMPIC FLAT BENCH

Stats 95. Statistical analysis without compelling presentation is annoying at best and catastrophic at worst. From raw numbers to meaningful pictures

E SERIES. Contents CALIBRATION PROCEDURE. Version 2.0

8/20/ Identify the functions of common ECG machines. 3.3 Explain how each ECG machine control is used. 3.4 Recognize common electrodes.

Cigarette Smoke Generator

POST-ACTIVATION POTENTIATION AND VERTICAL JUMP PERFORMANCE. Cody Hardwick

A Brain Computer Interface System For Auto Piloting Wheelchair

Testing the Accuracy of ECG Captured by Cronovo through Comparison of ECG Recording to a Standard 12-Lead ECG Recording Device

Posture Pump PENTAVEC Model 2500 Instructions

ANATOMIC. Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0

LABVIEW based expert system for Detection of heart abnormalities

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation

You make us tic. Leading an active life... syntic. contic + biotic + The first choice in the device-assisted conservative therapy of incontinence

CHAPTER 4 ANFIS BASED TOTAL DEMAND DISTORTION FACTOR

General Single Ion Calibration. Pete 14-May-09

Hemodynamic Analysis System

Electromyography Segmented Assessment for Lower Limb Muscle Transition to Fatigue During Isometric Contraction

Speed - Accuracy - Exploration. Pathfinder SL

SINCE 1978 MADE IN THE USA PRO 7000 SERIES SUPPLEMENTARY MACHINES MEDICAL SERIES. engineered for success

Protein quantitation guidance (SXHL288)

LIGHTING LABORATORY TESTING SERVICES EFFECTIVE & EFFICIENT ENERGY SAVING SOLUTIONS V1015W

Iso-inertial dynamometer

Outline of Talk. Introduction to EEG and Event Related Potentials. Key points. My path to EEG

Lesson 1 ELECTROMYOGRAPHY I Standard and Integrated EMG

Physiology Lessons for use with the Biopac Student Lab. Lesson 1 ELECTROMYOGRAPHY I Standard and Integrated EMG

CSDplotter user guide Klas H. Pettersen

Hanwell Instruments Ltd. Instruction Manual

A Hierarchical Artificial Neural Network Model for Giemsa-Stained Human Chromosome Classification

DETECTION OF HEART ABNORMALITIES USING LABVIEW

for Heart-Health Scanning

Biopac Student Lab Lesson 6 ELECTROCARDIOGRAPHY (ECG) II Analysis Procedure. Rev

Various Methods To Detect Respiration Rate From ECG Using LabVIEW

MODULE: SQUAT JUMP BRIEF DESCRIPTION:

What you re in for. Who are cochlear implants for? The bottom line. Speech processing schemes for

Digital. hearing instruments have burst on the

A NOVEL ALGORITHM TO PREDICT KNEE ANGLE FROM EMG SIGNALS FOR CONTROLLING A LOWER LIMB EXOSKELETON

EEG, ECG Measurement and Data Analysis. Carlo Lucignoli. ATSiP Teesside 2006

Doctoral School on Engineering Sciences Università Politecnica delle Marche

SedLine Sedation Monitor

EMG Signals for Co-Activations of Major Lower Limb Muscles in Knee Joint Dynamics

Digital hearing aids are still

STATISTICS AND RESEARCH DESIGN

Transcription:

BioGraph Infiniti DynaMap Suite 3.0 for ProComp Infiniti March 2, 2006 SA7990B Ver 3.0

DynaMap Suite 3.0 for ProComp Infiniti Contents List P Inf 8 Ch EMG Bi-Lateral Difference.chs 3 P Inf 8 Ch EMG.chs 4 P Inf 8 Ch Legs.chs 5 P Inf 5 Ch Multi Modality.chs 6 P Inf 4 Ch EMG 2 Goni 2 Force.chs 7 P Inf Force Calibration.chs 8 P Inf Goniometer Calibration.chs 9 P Inf Force Calibration.scr 10 P Inf Goniometer Calibration.scr 11 P Inf 2 Ch Raw Separated Graphs.scr 12 P Inf 2 Ch Raw Graphs Dual Screen.scr 13 P Inf 2 Ch Raw.scr 14 P Inf Ch A Test.scr (also B) 15 P Inf Ch C Test.scr (also D, E, F, G, H) 16 P Inf 2 Ch Spectral.scr 17 P Inf 8 Ch RMS.scr 18 P Inf 8 Ch RMS Bargraphs.scr 19 P Inf 8 Ch Line & Bar.scr 20 P Inf A and B RMS.scr (also C/D, E/F, G/H) 21 P Inf RMS A and B FFT.scr 22 P Inf 8 Ch RMS with Video.scr 23 P Inf 4 Ch RMS 2 Goni 2 Force.scr 24 P Inf EMG, Force, Goni, Video Dual Screen.scr 25 P Inf 2 Axis Goniometer.scr 26 P Inf 2 Ch Review RAW.scr 27 P Inf 2 Ch Review RAW Dual Screen with Video.scr 28 P Inf 8 Ch Review RMS.scr 29 P Inf 2 Ch Review Median Frequency.scr 30 P Inf 2 Ch Median Freq.scr 31 P Inf 2 Ch Median Freq with Video.scr 32 P Inf 1 Ch Median Freq with Log.scr 33 P Inf 2 Ch Bi-Lateral.scr 34 P Inf 8 Ch Bi-Lateral Bars.scr 35 P Inf 8 Ch Bi-Lateral + Video.scr 36 P Inf 2 Ch A - B Bi-Lateral + Video.scr (also C/D, E/F, G/H) 37 P Inf 8 Ch Bi-Lateral Back.scr 38 P Inf Para-spinal muscle activity.scr 39 P Inf Para-spinal and cervical comparison.scr 40 P Inf 5 Ch Multi Modality Overview.scr 41 P Inf 1 Ch EKG.scr 42 P Inf 2 Ch SC, Temp.scr 43 P Inf 2 Ch EMG.scr 44 P Inf 8 Ch Seated Iso + Anim.scr 45 Recuired Files for DynaMap Suite 3.0 for ProComp infiniti 46

Channel Sets P Inf 8 Ch EMG Bi-Lateral Difference.chs A. MyoScan-Flex B. MyoScan-Flex C. MyoScan- Pro 400 D. MyoScan- Pro 400 E. MyoScan- Pro 400 F. MyoScan- Pro 400 G. MyoScan- Pro 400 H. MyoScan- Pro 400 This channel set is designed with bi-lateral pairs of electrodes in mind, in placements such as the lumbar region. Two MyoScan-Flex channels is filtered with a notch, then a high pass IIR filter that is set by default to 0.5Hz this can be increased to filter out heart artifact if it becomes evident in the signal. It is converted from the raw state to an RMS value using the non-sliding window algorithm, with a time period of one second and an averaging factor of 10. For looking at the spectral of the signals it is converted by an FFT. The MyoScan-Pro sensor automatically converts SEMG signal to a root mean square (RMS) signal (an analog rectification is done inside the circuitry). The logic to determine if the signals have a difference greater than 20% is the following:- e.g. between channel A and B. (A > B + B x 0.2 OR A < B B x 0.2 ) OR (B > A + A x 0.2 OR B < A A x 0.2 ) To enable easy adjustment of the percentage difference all of the channels have been ganged together and converted into a real number. By changing the constant value of the channel labeled Insert % Difference Value Here from the default 20 to 30 the percentage used in all the channels will be changed to 30%. This Boolean output is then converted to a float and optionally smoothed for use in an instrument. This smoothed output is used in all the screens supplied with this channel set. An additional level of logic is added to the channel set to prevent small levels of environmental electronic noise from changing the value for the output. This logic looks at the level of the two signals and if it is below 2uV then it does not calculate the 20% difference, and the out put remains at 0 or the light off. Note 1: Smoothing has been added to some of the digital and animated bar graphs to enhance the clinical feedback. Smoothing has not been added to the red indicator lights, this smoothing delay can lead to a slight miss match between the numbers seen and the illumination of the light. Note 2: The frequency of Notch filter is necessary to set from the Biograph Infiniti application before recording a session by selecting Options, Notch Filters then 60Hz or 50 Hz. 3

P Inf 8 Ch EMG.chs A. MyoScan-Flex B. MyoScan-Flex C. MyoScan- Pro 400 D. MyoScan- Pro 400 E. MyoScan- Pro 400 F. MyoScan- Pro 400 G. MyoScan- Pro 400 H. MyoScan- Pro 400 Two MyoScan-Flex channels are filtered once through a notch filter to remove 60 Hz or 50 Hz noise, and then through a IIR high pass filter set to 20 Hz, this can be increased in the main application to 100 Hz to eliminate the heart rate artifact that may be detected when the electrodes are used in a number of locations. FFT, RMS, Median Frequency (MF), MF smoothed, Peak Frequency, Maximum, Minimum, Mean, Standard Deviation, Minimum MF, Variability, Mean MF are calculated for 2 channels. Six other channels are used to connect MyoScan- Pro sensors.. The MyoScan-Pro sensor automatically converts SEMG signal to a root mean square (RMS) signal (an analog rectification is done inside the circuitry). Maximum, Minimum, Mean, Standard Deviation, Variability are calculated for 6 MyoScan-Pro channels. 4

P Inf 8 Ch Legs.chs A. MyoScan-Flex B. MyoScan-Flex C. MyoScan-Pro 400 D. MyoScan-Pro 400 E. MyoScan-Pro 400 F. MyoScan-Pro 400 G. Goniometer H. Goniometer A collection of channels intended for the monitoring of dual leg activity and angle. Standard signal processing of the EMG signals. Goniometer channels are processed through a linear transform, enabling the calibration by the user. 5

P Inf 5 Ch Multi Modality.chs A. MyoScan-Flex B. MyoScan-Flex C. EKG-Pro/Flex D. Temp-Pro/Flex E. SC-Pro/Flex A mix of modalities to enable monitoring physiology and EMG simultaneously. Standard filtering on the EMG signal, with Notch and High Pass IIR filter and RMS and FFT calculations. EKG processed to detect the inter beat interval, from this Heart Rate is calculated and an FFT to look at the power spectrum. Temperature and Skin Conductance are also recorded and statistical values extracted. 6

P Inf 4 Ch EMG 2 Goni 2 Force.chs A. MyoScan-Flex B. MyoScan-Flex C. MyoScan-Pro 400 D. MyoScan-Pro 400 E. Force F. Force G. Goniometer H. Goniometer I. Alternative arrangement of sensors inputs, processing for each channel as described above. Note: - Goniometers and Torsiometers are interchangeable in the software. Goniometer, Torsiometer and Force sensors are all fed through a linear transform equation that is accessible within the main application. The input max and min values are correlated to the desired and calibrated output values. Sensors that are not connected at time of recording are automatically set to a raw input value of 1. If this channel is then processed through a linear transform virtual channel it may result in a constant value different from 1, and will display as such on the display screen. 7

P Inf Force Calibration.chs A. Force B. Force C. Force D. Force E. Force F. Force G. Force H. Force All Force channels are intended for calibrating Force sensors. 8

P Inf Goniometer Calibration.chs A. Goniometer B. Goniometer C. Goniometer D. Goniometer E. Goniometer F. Goniometer G. Goniometer H. Goniometer All Goniometer channels are intended for calibrating Goniometer/ Torsiometer sensors. 9

P Inf Force Calibration.scr Channel Set: P Inf Force Calibration.chs Category: Calibration Description: Force Calibration. Screen intended for force sensors calibration. To calibrate the sensors, connect the hardware and open the Force calibration screen then start a recording. Apply a know load to the force sensor and record the loaded (max) and unloaded (min). Stop the session and move to the channel set that is going to be used to record data, edit the virtual channel set and select the virtual channel relating to the sensor that you are calibrating. Manually enter the input Min and Max values and the corresponding output min and max values of the known load. It is also possible to enter the units of measure which will appear in generated reports. Note: - A force sensor converts the load applied to a raw value, as the load changes the value corresponding to that load changes with it. This raw value can be transformed into a meaningful calibrated value in the software by using the linear transform virtual channel. This linear transform takes the minimum and maximum raw value and converts it to the min-max output values corresponding to the positions (e.g. - 719 to 845 becomes 0 to 10 lbs). 10

P Inf Goniometer Calibration.scr Channel Set: P Inf Goniometer Calibration.chs Category: Calibration Description: Goniometer Calibration. Screen intended for goniometer sensors calibration. To calibrate the sensors, connect the hardware and open the goniometer calibration screen then start a recording. Manipulate the goniometer to its maximum and minimum specified deflection. Record the max and min values. Stop the session and move to the channel set that is going to be used to record data, edit the virtual channel set and select the virtual channel relating to the axis that you are calibrating. Manually enter the input Min and Max values and the corresponding output min and max values. It is also possible to enter the units of measure which will appear in generated reports. Note: -.A goniometer sensor converts its position to a raw value, as the position changes the value corresponding to that position changes with it. Most goniometers have a specified minimum and maximum deflection. This raw value can be transformed into a meaningful calibrated value in the software by using the linear transform virtual channel. This linear transform takes the minimum and maximum raw value and converts it to the min-max output values corresponding to the positions (e.g. -119 to 70 becomes 0 to 180 Degrees.) 11

P Inf 2 Ch Raw Separated Graphs.scr Channel Set: P Inf 8 Ch EMG.chs Category: RAW Description: 2 Ch Raw 2 channels of RAW EMG each on its own line graph. No feedback. 12

P Inf 2 Ch Raw Graphs Dual Screen.scr Channel Set: P Inf 8 Ch EMG.chs Category: RAW Description: 2 Ch Raw Two screens containing 2 channels of RAW EMG each on its own line graph, a digital readout of each channel converted to RMS. Video to display from the web cam. No feedback 13

P Inf 2 Ch Raw.scr Channel Set: P Inf 8 Ch EMG.chs Category: RAW Description: 2 Ch Raw 2 channels of RAW EMG on multi line graph. No feedback. 14

P Inf Ch A Test.scr (also B) Channel Set: P Inf 8 Ch EMG.chs Category: Review Description: Test screen Ch A A sample of information from the output of channel A. Raw Line graph, RMS line Graph, Max, Mean, Min, Std Deviation, Variability stats, and Median and Peak Frequencies and a 2D power spectrum. This screen has been duplicated for channel B. 15

P Inf Ch C Test.scr (also D, E, F, G, H) Channel Set: P Inf 8 Ch EMG.chs Category: Review Description: Test screen Ch C A sample of information from the output of channel C. RMS line Graph, Max, Mean, Min, Std Deviation, Variability stats. This screen has been duplicated for D, E, F, G, H channels as a test of each channel. 16

P Inf 2 Ch Spectral.scr Channel Set: P Inf 8 Ch EMG.chs Category: RAW Description: 2 Ch Raw 2 channels of Spectral from Raw EMG divided bilaterally two signals left and right per spectral display with RMS EMG bargraphs for each channel at the side. 17

P Inf 8 Ch RMS.scr Channel Set: P Inf 8 Ch EMG.chs Category: RMS Description: 8 Ch RMS 8 channels of RMS data shown in bi-lateral pairs on multi line graphs. 18

P Inf 8 Ch RMS Bargraphs.scr Channel Set: P Inf 8 Ch EMG.chs Category: RMS Description: 8 Ch RMS Bargraphs 8 Channels of RMS data shown in multiple bar graphs with digital display of value. 19

P Inf 8 Ch Line & Bar.scr Channel Set: P Inf 8 Ch EMG.chs Category: RMS Description: 8 Ch RMS Line Graph and Bar Graphs. 8 Channels of RMS data derived from the 2 RAW inputs (Channels A and B) and 6 RMS inputs (channels C, D, E, F, G, H) shown in 2 line graphs for signals A,B and bar graphs for the other 6 signals. 20

P Inf A and B RMS.scr (also C/D, E/F, G/H) Channel Set: P Inf 8 Ch EMG.chs Category: RMS Description: 2 Ch RMS A and B 2 channels of RMS data shown in a line graph. This screen has been duplicated for the other 3 pairs of channels. 21

P Inf RMS A and B FFT.scr Channel Set: P Inf 8 Ch EMG.chs Category: RMS Description: 2 Ch RMS A and B with 3D FFT display. 2 Channels of RMS data derived from the channels A and B RAW inputs to the ProComp shown in a line graph. 22

P Inf 8 Ch RMS with Video.scr Channel Set: P Inf 8 Ch EMG.chs Category: RMS Description: 8 Ch RMS with Video. 8 channels of RMS data shown in line graphs. It also shows a single video view. 23

P Inf 4 Ch RMS 2 Goni 2 Force.scr Channel Set: P Inf 4 Ch EMG 2 Goni 2 Force.chs Category: General Description: 4 Ch of EMG with Force and Goniometers. Two line graphs showing RMS EMG signals and two line graphs one for Goniometer dual axis and one for two force sensors. 24

P Inf EMG, Force, Goni, Video Dual Screen.scr Channel Set: P Inf 4 Ch EMG 2 Goni 2 Force.chs Category: General Description: 4 Ch of EMG with Force and Goniometers. Two line graphs showing RMS EMG signals and two line graphs one for Goniometer dual axis and one for two force sensors. Extended onto a second screen which displays a video display 25

P Inf 2 Axis Goniometer.scr Channel Set: P Inf 4 Ch EMG 2 Goni 2 Force.chs Category: Goniometer Description: 2 Axis Goniometer. 2 Channels of dual axis goniometer displayed on line graph. 26

P Inf 2 Ch Review RAW.scr Channel Set: P Inf 8 Ch EMG.chs Category: Review Description: 2 Ch Raw with stats for review. 2 Ch EMG review with RAW line graphs shown. 27

P Inf 2 Ch Review RAW Dual Screen with Video.scr Channel Set: P Inf 8 Ch EMG.chs Category: Review Description: 2 Ch Raw with stats for review. 2 Ch EMG review with RAW line graphs shown, with the addition of a dual screen and a video display. 28

P Inf 8 Ch Review RMS.scr Channel Set: P Inf 8 Ch EMG.chs Category: Review Description: 8 Ch RMS with stats for review. 8 channel review screen, with instruction. RMS data shown. 29

P Inf 2 Ch Review Median Frequency.scr Channel Set: P Inf 8 Ch EMG.chs Category: Review Description: 2 Ch Median Freq with stats for review. 2 channel review screen, with instruction. Median Frequency data shown. By moving the vertical red cursor available in the review mode it is possible to view statistics in the table above corresponding to any part of the session displayed as Median Frequency in the lower screens. The Median Frequency displayed in the table and the line graphs is smoothed to decrease the rapid changes and show a better trend. 30

P Inf 2 Ch Median Freq.scr Channel Set: P Inf 8 Ch EMG.chs Category: Median Freq Description: 2 Ch Median Freq with stats for recording. 2 Channel recording screen, for looking at interplay of median frequency and RMS data between two bilateral sites. Median Frequency data shown. All Median Freq statistics are based on smoothed MF to give a slower higher level view of this measure. 31

P Inf 2 Ch Median Freq with Video.scr Channel Set: P Inf 8 Ch EMG.chs Category: Median Freq Description: 2 Ch Median Freq with stats for recording. 2 Channel recording screen, for looking at interplay of median frequency and RMS data between two bilateral sites. Median Frequency data shown. All Median Freq statistics are based on smoothed MF to give a slower higher level view of this measure. Dual screen with video and larger graphing spaces. 32

P Inf 1 Ch Median Freq with Log.scr Channel Set: P Inf 8 Ch EMG.chs Category: Median Freq Description: 1 Ch Median Freq with histogram. 1 Channel recording screen, for looking at a trend of median frequency and RMS data over a clinical session. All Median Freq statistics are based on smoothed MF to give a slower higher level view of this measure. By changing the settings for the comparator virtual channel it is possible to trigger on the rising or falling edge of the RMS. 33

P Inf 2 Ch Bi-Lateral.scr Channel Set: P Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: 2 Ch of Bi-Lateral difference. One pairs of channels A vs B, showing difference when greater than 20% indicated by lights turning red. Linegraphs showing RMS SEMG of each muscle site. 34

P Inf 8 Ch Bi-Lateral Bars.scr Channel Set: P Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: 8 Ch of Bi-Lateral difference. Five pairs of channels A vs B, C vs D, E vs F, and G vs H showing difference when greater than 20% indicated by lights turning red. Designed with the intent of evaluating lumbar muscle pairs during forward flexion. Layout of the screen such as to aid in the bilateral evaluation of problem areas. Animated bars and digital displays showing RMS SEMG of each muscle site. 35

P Inf 8 Ch Bi-Lateral + Video.scr Channel Set: P Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: 8 Ch of Bi-Lateral difference. Five pairs of channels A vs B, C vs D, E vs F, G vs H showing difference when greater than 20% indicated by lights turning red. Designed with the intent of evaluating lumbar muscle pairs during forward flexion. Layout of the screen such as to aid in the bilateral evaluation of problem areas. Animated bars and digital displays showing RMS SEMG of each muscle site. Includes video display to show web cam footage. 36

P Inf 2 Ch A - B Bi-Lateral + Video.scr (also C/D, E/F, G/H) Channel Set: P Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: 2 Ch A - B of Bi-Lateral difference with Video. One pair of channels A vs B, showing difference when greater than 20% indicated by lights turning red. Designed with the intent of evaluating lumbar muscle pairs during forward flexion. Animated bars and digital displays showing RMS SEMG of each muscle site. Video enables viewing of the motion performed. 37

P Inf 8 Ch Bi-Lateral Back.scr Channel Set: P Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: 8 Ch of Bi-Lateral difference. Five pairs of channels A vs B, C vs D, E vs F, and G vs H showing difference when greater than 20% indicated by lights turning red. Designed with the intent of evaluating lumbar muscle pairs during forward flexion. Layout of the screen such as to aid in the bilateral evaluation of problem areas. Animated bars and digital displays showing RMS SEMG of each muscle site 38

P Inf Para-spinal muscle activity.scr Channel Set: P Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: Bilateral comparison of para-spinal muscle activity. Five pairs of channels A vs B at C7 T1, C vs D at T6 T7, E vs F at T12 L1, G vs H at L2 L3, Bi-lateral difference when greater than 20% is indicated by lights turning red. Designed with the intent of evaluating para-spinal muscle pairs during forward flexion. Layout of the screen such as to aid in the bilateral evaluation of problem areas. Animated bars and digital displays showing RMS SEMG of each muscle site. 39

P Inf Para-spinal and cervical comparison.scr Channel Set: F Inf 8 Ch EMG Bi-Lateral Differences.chs Category: Difference Description: Para-spinal and cervical muscle activity. Five pairs of channels A vs B at C2 C3, C vs D at C7 T1, E vs F at T6 T7, G vs H at T12 L1, Bi-lateral difference when greater than 20% is indicated by lights turning red. Designed with the intent of evaluating para-spinal including cervical muscle pairs during forward flexion. Layout of the screen such as to aid in the bilateral evaluation of problem areas. Animated bars and digital displays showing RMS SEMG of each muscle site. 40

P Inf 5 Ch Multi Modality Overview.scr Channel Set: P Inf 5 Ch Multi Modality.chs Category: Multi Modality Description: Overview of Signals. A multi-modality use of the ProComp encoder, this channel set and screen presents data from the EMG, EKG, Temp and Skin Conductance sensors. EKG Heart Rate, IBI, Max, Min Mean, Peak Freq, Std Dev in Heart Rate. Temp Max, Min, Mean, Real Time. SC Mean, Real Time EMG Two channels of real time RMS EMG and the Mean for each channel. 41

P Inf 1 Ch EKG.scr Channel Set: P Inf 5 Ch Multi Modality.chs Category: Multi Modality Description: EKG Overview of Signals. Focusing on EKG and heart rate, this screen shows in line graphs both the heart rate and the raw EMG signal. Standard Deviation of the heart rate is shown as a bar graph on the right of the screen. A Fast Fourier Transform of the inter-beat interval (IBI) is displayed in both a 3D and a 2D power spectrum, to accompany these there is a digital display showing the peak frequency. Real-time measurements of Heart Rate, IBI, Max, Min and Mean Heart Rates are also displayed. 42

P Inf 2 Ch SC, Temp.scr Channel Set: P Inf 5 Ch Multi Modality.chs Category: Multi Modality Description: SC, Temp Overview of Signals. This screen shows in line graphs both the Temperature and Skin Conductance. Real-time measurements of Temperature, Skin Conductance, Max, Min and Mean are also displayed. 43

P Inf 2 Ch EMG.scr Channel Set: P Inf 5 Ch Multi Modality.chs Category: Multi Modality Description: EMG, Temp Overview of Signals. Focusing on EMG, this screen shows in line graphs both the RMS and the raw EMG signal. 2D Power Spectrums show the result of the FFT performed on the two channels. Real-time measurements of RMS, Max, Min and Mean are displayed. 44

P Inf 8 Ch Seated Iso + Anim.scr Channel Set: P Inf 8 Ch Legs.chs Category: Goniometer Description: EMG and Goniometer for leg evaluation Focusing on EMG activity and angle of the knee when subject is seated during extension and flexion, this screen displaying the placement and RMS readings from six EMG sensors, and Goniometer. Placement is on the Quadriceps Femoris, Vastus Lateralis and the Vastus Medialis. This screen can be used with others in the leg series to give an integrated view of the leg as a whole. Animation works with the client, as they move their leg the animation moves. Set the animation scale to the max min readings of goniometer G. 45

Recuired Files for DynaMap Suite 3.0 for ProComp infiniti Channel Sets (.chs ) P Inf 8 Ch EMG.chs P Inf 8 Ch EMG Bi-Lateral Difference.chs P Inf 8 Ch Legs.chs P Inf 5 Ch Multi Modality.chs P Inf 4 Ch EMG 2 Goni 2 Force.chs P Inf Force Calibration.chs P Inf Goniometer Calibration.chs Screens (.scr ) P Inf Force Calibration.scr P Inf Goniometer Calibration.scr P Inf 2 Ch Raw Separated Graphs.scr P Inf 2 Ch Raw Graphs Dual Screen.scr P Inf 2 Ch Raw.scr P Inf Ch A Test.scr (also B) P Inf Ch C Test.scr (also D, E, F, G, H) P Inf 2 Ch Spectral.scr P Inf 8 Ch RMS.scr P Inf 8 Ch RMS Bargraphs.scr P Inf 8 Ch Line & Bar.scr P Inf A and B RMS.scr (also C/D, E/F, G/H) P Inf RMS A and B FFT.scr P Inf 8 Ch RMS with Video.scr P Inf 4 Ch RMS 2 Goni 2 Force.scr P Inf EMG, Force, Goni, Video Dual Screen.scr P Inf 2 Axis Goniometer.scr P Inf 2 Ch Review RAW.scr P Inf 2 Ch Review RAW Dual Screen with Video.scr P Inf 8 Ch Review RMS.scr P Inf 2 Ch Review Median Frequency.scr P Inf 2 Ch Median Freq.scr P Inf 2 Ch Median Freq with Video.scr P Inf 1 Ch Median Freq with Log.scr P Inf 2 Ch Bi-Lateral.scr P Inf 8 Ch Bi-Lateral Bars.scr P Inf 8 Ch Bi-Lateral + Video.scr P Inf 2 Ch A - B Bi-Lateral + Video.scr (also C/D, E/F, G/H) P Inf 8 Ch Bi-Lateral Back.scr P Inf Para-spinal muscle activity.scr P Inf Para-spinal and cervical comparison.scr P Inf 5 Ch Multi Modality Overview.scr P Inf 1 Ch EKG.scr P Inf 2 Ch SC, Temp.scr 46

P Inf 2 Ch EMG.scr P Inf 8 Ch Seated Iso + Anim.scr Animations Linear R to L Rainbow Bar.avi Linear L to R Rainbow Bar.avi Man with leg flex.avi Binary Red Light.avi Pictures back.bmp 47