Femoral / Tibial Augmentation. Orthopaedic Salvage System

Similar documents
Resurfacing Distal Femur. Orthopaedic Salvage System

Tibial Replacements. Orthopaedic Salvage System

OSS Modular Arthrodesis System. Assembly Guide

Biomet Large Cannulated Screw System

Distal Cut First Femoral Preparation

MIS Cemented Tibial Component

EXACTECH KNEE. Operative Technique ADDENDUM. Metaphyseal Cones. Surgeon focused. Patient driven. TM

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

OSS Orthopedic Salvage System Compress Device. Surgical Technique

THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME

OSS Overview Biomet Oncology Salvage System Featuring the Finn Knee

U2 PSA. Revision Knee. Surgical Protocol

NEXGEN COMPLETE KNEE SOLUTION S A. Tibial Stem Extension & Augmentation Surgical. ATechnique

THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM

Single Axis Revision Knee System

MRH Knee System Modular Peg Baseplate Surgical Protocol

TOTAL KNEE ARTHROPLASTY SYSTEM

HP KNEE EXTRACTION Instrumentation. Product Overview

ANATOMIC SURGICAL TECHNIQUE. 5 in 1. Conventional instrumentation 07/11/2013

Patella Planing System

Surgical Technique. VISIONAIRE FastPak Instruments for the LEGION Total Knee System

Profix. Total Knee System. As described by

Surgical Technique. VISIONAIRE Disposable Instruments for the LEGION Total Knee System

Triathlon TS Knee System. Surgical Protocol

THE P.F.C. SIGMA FEMORAL ADAPTER. Surgical Technique

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique. IMAGE TO COME Designed for minimally invasive procedures

HP Knee Extraction Instrumentation. Product Overview

TRK REVISION KNEE Surgical Technique

Scorpio TS Single Axis Revision Knee System. Scorpio Total Stabilizer Revision Knee System Surgical Protocol

Total Knee Original System Primary Surgical Technique

PRIMARY POROUS PATELLA WITH TRABECULAR METAL. Surgical Technique

Revolution. Unicompartmental Knee System

Zimmer NexGen Tibial Stem Extension & Augmentation. Surgical Technique IMAGE TO COME. Stem Extensions and Augments

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

S U R G I C A L T E C H N I Q U E David A. McQueen, MD Return to Menu

ELEOS Limb Salvage System

Tibial & Femoral Opening Wedge Osteotomy System. Surgical Technique

Resurfacing Patellar Preparation

Zimmer NexGen Trabecular Metal Tibial Tray

Constrained Posterior Stabilized (CPS)

operative technique Kent Hip

Intramedullary Tibial Preparation

Patient Specific Instruments. Surgical Technique

Wichita Fusion Nail Surgical Technique. David A. McQueen, MD

PLR. Proximal Loading Revision Hip System

Anterior Cut First Surgical Technique

Taperloc Complete Hip System. Surgical Technique

Proven Gen-Flex Revision Knee System. Surgical Protocol

Signature Personalized Patient Care

ELEOS Limb Salvage System

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

TRABECULAR METAL AUGMENTS. Includes Surgical Technique Abbreviated for LCCK and RHK Trabecular Metal Augments

Orthopedic Bone Nail System - Distal Femoral Nail Surgical Technique Manual

Trabecular Metal Primary Patella

The Bio-Modular Choice Shoulder System,

Triathlon Knee System. Universal Baseplate Surgical Protocol

Surgical Technique. Hinge Disassembly and Rebuild Technique

Triathlon Knee System Universal Baseplate Surgical Protocol

Constrained Posterior Stabilized (CPS) Surgical Technique

1. Pre-Operative Planning Skin Incision and Arthrotomy

Bone Preservation Stem

Tibial Fixation. with TunneLoc Device. Surgical Technique by Mark J. Albritton, M.D. and Sherwin Ho, M.D.

Zimmer Patient Specific Instruments. Surgical Techniques for NexGen Complete Knee Solution

Medial Rotation Knee. Forever Active. Landmark Operative Technique Supplement: No.1 All-Polyethylene Tibia (Cemented)

PIN GUIDE SYSTEM SURGICAL TECHNIQUE. with the SIGMA High Performance Instruments System. This publication is not intended for distribution in the USA.

NEXGEN COMPLETE KNEE SOLUTION. Revision Instrumentation Surgical Technique For Legacy Knee Constrained Condylar Knee

NexGen Trabecular Metal Tibial Tray. Surgical Technique

A novel cementless option. Zimmer NexGen Trabecular Metal Primary Patella Surgical Technique

RECOVERY. P r o t r u s i o

Arcos Modular Femoral Revision System. Broach and Calcar Proximal Bodies Surgical Technique

Zimmer Patient Specific Instruments. Surgical Technique for Gender Solutions Natural-Knee Flex System

Approach Patients with Confidence

Persona. The Personalized Knee. Trabecular Metal Tibia. Surgical Technique

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

Extramedullary Tibial Preparation

FLH /11

Answer. Hip System Design Features:

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

OptiLock Periarticular Plating System For Distal Tibial Fractures. Surgical Technique

Knee Replacement Implants

REVISION SYSTEM DIFFERENT NEEDS...YOUR GLOBAL SOLUTION. Hip Knee Spine Navigation GLOBAL MEDACTA KNEE

StageOne. Shoulder Cement Spacer Molds. Surgical Technique

Approach Patients with Confidence

Surgical Technique Guide

RESECTION GUIDE SYSTEM. TRUMATCH Personalized Solutions Surgical Technique with ATTUNE Knee INTUITION Instruments

Trabecular Metal Tibial Cone Surgical Technique

The information contained in this document is intended for healthcare professionals only.

Pin Guide System. Surgical Technique

Femur. Monoaxial Locking Plate System. Operative Technique. Distal Lateral Femur Universal Holes Targeting Instrumentation.

Aesculap Targon TX. Intramedullary Nail for Tibial Fractures...going to X-tremes. Aesculap Orthopaedics

Zimmer NexGen Rotating Hinge Knee Primary/ Revision

Figure 3 Figure 4 Figure 5

14 mm x +30 mm Stem Extension

Gamma3 TM Fragment Control Clip

Zimmer NexGen RH Knee Primary/Revision. Surgical Technique

DFS Hip Distractor. Surgical Technique

Revision. Hip Stem. Surgical Protocol

Transcription:

Femoral / Tibial Augmentation Orthopaedic Salvage System

OSS Tibial Block Augments Preparation To utilize the OSS tibial block augments (available as 10mm universal and 20mm side-specific components), the following steps should be taken after the initial resection of the tibial plateau: Apply the appropriate tibial template and, using methylene blue or a cautery device, mark reference points through the center of the template on both anterior and posterior aspects of the tibial canal. Remove the tibial template (). Hold the tibial block augment trial to the affected anterior portion of the tibia and, using the augment trial as a guide, make reference marks on both the distal and medial areas. Remove the augment trial (Figures 2 & 3). Using the reference marks, complete the transverse and sagittal resections (Figures 4 6). The Orthopaedic Salvage System features the Finn Rotating Hinge Knee. The Finn Rotating Hinge Knee was developed by Henry A. Finn, M.D., F.A.C.S., in conjunction with Biomet, Inc. OSS & Finn are trademarks of Biomet Manufacturing Corp., Warsaw, IN. This brochure is presented to demonstrate the surgical technique recommended by: Henry A. Finn, M.D., F.A.C.S. Chief of Orthopaedic Surgery Weiss Memorial Hospital Professor of Surgery, Orthopaedic Surgery University of Chicago Chicago, IL John H. Healey, M.D., F.A.C.S. Chief of Orthopaedic Surgery Memorial Sloan-Kettering Cancer Center Professor of Surgery, Orthopaedic Surgery Weil Medical College of Cornell University New York, NY Edward J. McPherson, M.D. Associate Professor Department of Orthopaedic Surgery USC School of Medicine Los Angeles, CA L. Daniel Wurtz, M.D. Associate Professor Department of Orthopaedic Surgery Indiana University School of Medicine Indianapolis, IN Figure 5 Figure 4 Figure 6

OSS Tibial Block Augments Trial Assembly Place the augment trial against the inferior side of the tibial base plate trial and, using the 3.5mm short screwdriver, tighten the set screw located within the augment trial (). Place the augment trial/base plate trial assembly into the prepared tibia and proceed with the reduction (). Implant Assembly The tibial augment(s) is attached to the inferior surface of the tibial base plate with bone cement. Hold the augment(s) securely to the base plate with either a patellar clamp or digital pressure while the cement cures (if using a patellar clamp, make sure to use the non-marring portion of the clamp on the polished base plate surface) (Figures 3 & 4). Note: It is imperative that the augment(s) is cemented to the tibial base plate prior to implantation. Biomet, as the manufacturer of this product, does not practice medicine and does not recommend this or any other system for use on a specific patient. The surgeon who performs any procedure is responsible for determining and utilizing the appropriate techniques for such procedure for use on a specific patient. Biomet is not responsible for selection of the appropriate surgical technique or products to be utilized for an individual patient. Figure 4 1

OSS Tibial Sleeve Augments To utilize the OSS tibial sleeves (available as large and small components), the following steps should be taken after the initial resection of the tibial plateau: Small Tibial Sleeve Note: The small tibial sleeve implant must be used in conjunction with 10mm tibial augments. Broach Assembly Insert the tibial sleeve broach shaft through the small tibial sleeve trial, making sure that the inset groove of the broach shaft and the set screw on the sleeve trial match up (). With the two parts seated, use the 3.5mm short screwdriver to tighten the set screw (Figures 2 & 3). Metaphyseal Preparation Attach the T-handle to the broach shaft and place the broach shaft/sleeve assembly into the tibia. Use a slow, uniform twisting motion to work the sleeve trial into the tibial deficit (Figures 4 & 5). Important: Never use a power source with this broach shaft/sleeve assembly. 2 Figure 4 Figure 5

OSS Tibial Sleeve Augments Small Tibial Sleeve Trial Assembly Place two 10mm block augment trials (that correspond to the size of the base plate trial) onto the inferior side of the base plate trial and secure the set screws with the 3.5mm short screwdriver (Figures 1 & 2). Slide the small tibial sleeve trial over the boss of the base plate trial and tighten the set screw with the 3.5mm short screwdriver (Figures 3 & 4). Place the augment/trial plate assembly into the prepared tibia and proceed with the reduction (Figure 5). Figure 4 Figure 5 3

OSS Tibial Sleeve Augments Small Tibial Sleeve Implant Assembly Note: If a stem is added to the tibial base plate, perform the impaction of the base plate and stem prior to adding the tibial augments and tibial sleeve. The 10mm tibial augments are attached to the inferior surface of the tibial base with bone cement (). Hold the augments securely to the base plate with either a patellar clamp or digital pressure while the cement cures (if using a patellar clamp, make sure to use the nonmarring portion of the clamp on the polished base plate surface). With the tibial augments in place, a liberal supply of bone cement is applied to both the inferior surface of the tibial augments and the exposed boss of the tibial base plate. Slide the tibial sleeve over the distal end of the boss and onto the bone cement, making certain that the cement fully extrudes up through the entire internal tibial sleeve/ boss construct. Use digital pressure while the cement cures (Figures 2 & 3). Important: It is imperative that the sleeve/block augment construct is cemented to the tibial base plate prior to implantation. 4

OSS Tibial Sleeve Augments Large Tibial Sleeve Note: The large tibial sleeve implants are cemented directly to the tibial base plates, and cannot be used with any tibial block augment. Broach Assembly Insert the tibial sleeve broach shaft through the large tibial sleeve trial, making sure that the inset groove of the broach shaft and the set screw on the sleeve trial match up. With the two parts seated, use the 3.5mm short screwdriver to tighten the set screw (Figures 1 3). Metaphyseal Preparation Attach the T-handle to the broach shaft and place the broach shaft/sleeve assembly into the tibia. Use a slow, uniform twisting motion to work the sleeve trial into the tibial deficit (Figures 4 & 5). Important: Never use a power source with this broach shaft/sleeve assembly. Figure 4 Figure 5 5

OSS Tibial Sleeve Augments Large Tibial Sleeve Trial Assembly Slide the large tibial sleeve trial over the boss of the base plate trial and tighten the set screw with the 3.5mm short screwdriver. Place the augment/trial plate assembly into the prepared tibia and proceed with the reduction (Figures 1 4). If a stem will be added to the actual tibial base plate component, attach the corresponding stem trial to the base plate trial prior to insertion to replicate the actual construct. Large Tibial Sleeve Implant Assembly Note: If a stemmed tibial base plate is indicated, impact the base plate and stem prior to cementing the large tibial sleeve into place. Apply a liberal quantity of bone cement to the inferior surface of the tibial base plate and to the exposed tibial boss. Slide the large tibial sleeve over the distal end of the boss and onto the bone cement, making certain that the cement fully extrudes up through the entire internal tibial sleeve/boss construct. Use digital pressure while the cement cures (Figures 5 & 6). Important: It is imperative that the large sleeve is cemented to the tibial base plate prior to implantation. 6 Figure 4 Figure 6 Figure 5

OSS Anterior Femoral Flange Augment To utilize the OSS anterior femoral flange augment with a 3cm resurfacing femoral component, the following steps should be taken after preparing the distal femur: Trial Assembly After inserting the assembled 3cm resurfacing femoral trial onto the prepared femur, slide the anterior flange augment trial under the femoral trial s anterior flange (the flange augment trial should match up precisely with the flange of the femoral trial) (Figures 1 & 2). Implant Assembly Note: Impact the stem and resurfacing femoral component prior to cementing the anterior flange augment into place. Apply a liberal quantity of bone cement to the femoral component s anterior flange, as well as to the corresponding surface of the anterior flange augment (). It is important that the anterior flange augment is properly aligned with the femoral component s anterior flange. Clean away all extruded cement, and use firm digital pressure while the cement cures (Figure 4). The assembled components are implanted in the usual manner. Figure 4 7

OSS Femoral Sleeve Augment To utilize the OSS femoral sleeves (available as left and right components) with the 3cm resurfacing femorals, the following steps should be taken after preparing the distal femur: Broach Assembly Thread the stem trial to the femoral sleeve broach shaft (). Insert the femoral sleeve broach shaft into the universal femoral sleeve trial, making sure that the insert groove of the broach shaft and the set screw on the sleeve trial match up (). With the two parts seated, use the 3.5mm short screwdriver to tighten the set screw (). 8

OSS Femoral Sleeve Augment Metaphyseal Preparation Attach the T-handle to the broach shaft and place the assembly into the femoral canal defect (Figures 1 & 2). Use a slow, uniform twisting motion to work the sleeve trial into the femoral canal until properly seated (). Important: Never use a power source with this broach shaft/sleeve assembly. Implant Assembly Note: Impact the stem and resurfacing femoral component prior to cementing the femoral sleeve augment into place. Apply a liberal quantity of bone cement to the superior surface and to the exposed boss of the 3cm resurfacing femoral component. Slide the femoral sleeve down the stem, over the boss and onto the bone cement, making sure cement extrudes from within the femoral sleeve/boss area. Clean away all extruded cement, and use firm digital pressure while the cement cures (Figures 4 6). Figure 4 Figure 5 Figure 6

THE MOST RESPONSIVE COMPANY IN ORTHOPEDICS SM P.O. Box 587, Warsaw, IN 46581-0587 574.267.6639 2003, 2004 Biomet Orthopedics, Inc. All Rights Reserved web site: www.biomet.com email: biomet@biomet.com Form No. Y-BMT-800R/033104/K