by Maico Diagnostics

Similar documents
Handheld OAE-Tympanometry Combination System

OAE Test System. by Maico Diagnostics ERO SCAN. EroScan Pictured. OAE Hearing Screener DPOAE/TEOAE Test Systems.

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

ERO SCAN. Otoacoustic Emission Testing

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

Reliable, flexible & precise

OtoRead Portable OAE. More Time for Care. Optimized for Accuracy and Ease of use

ABR Screener Excellence in Newborn Hearing Screening

A Guide to. Otoacoustic Emissions (OAEs) for Physicians.

A Guide to. Otoacoustic Emissions (OAEs) for Otolaryngologists.

Early Hearing Detection & Intervention Programs, Pediatricians, Audiologists & School Nurses use AuDX Screeners

(OAEs) for. Steven D. Smith, Au.D.

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

The Eclipse High quality evoked potentials at your command. AEP, ASSR, & OAE testing on one dedicated platform

QUICK START GUIDE SENTIERO DESKTOP OAE AND TYMP SCREENER (BLUE HOUSING)

ABR Screener Excellence in Newborn Hearing Screening

Neuro-Audio Version 2010

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

(OAEs) for. Physicians. Steven D. Smith, Au.D.

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

Bio-logic AuDX PRO FLEX Quick start Quick start guide

Hearing Evaluation: Diagnostic Approach

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

O A E screening with a C A R It s just more F U N! OAE+

General Catalogue. Product Line for Hearing Screening & Diagnostics

General Catalogue. Hearing Screening & Diagnostics

General Catalogue. Product Line for Hearing Screening & Diagnostics

Biologic AuDX/Welch Allyn Quick Screen Instructions ECHO Training/Workshops

A full product range for your every need. World leading diagnostic solutions

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

General Catalogue. Hearing Screening & Diagnostics

General Catalogue. Product Line for Hearing Screening & Diagnostics

Science made smarter. Titan. Advanced made flexible. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

Bio-logic AuDX PRO FLEX Diagnostic OAE and audiometry Quick start guide

QUICK START GUIDE SENTIERO HANDHELD OAE AND AUDIOMETRY SCREENER (GREEN LABEL)

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

Operation Manual. OtoRead Screener

the truly automated all-in-one hearing screener

School Nurses Guide to Otoacoustic Emissions (OAEs)

QUICK START GUIDE SENTIERO DESKTOP DIAGNOSTIC (WHITE HOUSING)

Oscilla - excellence since 1960

AC40. The true clinical. hybrid

Comparison of Screening Otoacoustic Emission Devices for Pre-school Aged Children

Welch Allyn OAE Hearing Screener. Directions for use

AD629 The true hybrid

AT235 Middle Ear Analyzer. Diagnostic & clinical tympanometry with basic audiometry

the truly automated all-in-one hearing screener Only the Echo-Screen Hearing Screener combines

The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform

The following describes general use of ELIOS device

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER

On the following pages you ll find a few more specific features to consider in evaluating OAE equipment.

Operation Manual. OtoRead Standard & Clinical

The true clinical hybrid audiometer. Interacoustics. Clinical Audiometer AC40. Stand alone & PC-based audiometry in one box.

QUICK START GUIDE TYMPANOMETRY AND AUDIOMETRY FOR SENTIERO DESKTOP DEVICES

ATMOS 360 diagnostics. Complete solution.

3. How does your state collect these results? (Check all that apply.) collecting this information.

Welch Allyn OAE Hearing Screener. Directions for use

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

The Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems

Advanced otoacoustic emission detection techniques and clinical diagnostics applications

Affinity 2.0 integrated fitting solution. Audiometry, REM, HIT, and Visible Speech Mapping

FALSE POSITIVE DP GRAMS

Otoacoustic Emissions As A Test Of Noise-Induced Hearing Loss. Brenda L Lonsbury-Martin PhD

Comparison of Distortion Product Otoacoustic Emission Amplitude between Normal Hearing Male and Female Subjects

FONIX FP35. Ease and Accuracy with the FP35 Touch Hearing Aid Analyzer! Visible Speech

Clinical applications of otoacoustic emissions in Industry. Prof. Dr. B. Vinck, MSc, PhD University of Ghent, Belgium

GSI 61 CLINICAL TWO-CHANNEL AUDIOMETER

Emissions are low-intensity sounds that may be detected in the external ear canal by a microphone

OAE Screening in Healthcare Settings: A Pilot Project. Terry E. Foust, AuD William Eiserman, PhD Lenore Shisler, MS

The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box. Interacoustics. Clinical Audiometer AC40.

Improving the diagnostic power of otoacoustic emissions. Arturo Moleti Physics Department University of Roma Tor Vergata

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

MI 44 Operating Instructions

OtoAcoustic Emissions (OAE s)

HEALTH SERVICES. Vision & Hearing Screening. Assisting Schools with Their Vision & Hearing Screening Equipment Since 1957

BERA The HOMOTH ABR / BERA- module is a real time brainstem audiometer. It is developed considering the latest knowledge of the ENT research.

AA222 / AA220. Audio Traveller. Save time on routine. Focus on results. Interacoustics. leading diagnostic solutions

Educational Module Tympanometry. Germany D Germering

MADSEN AccuScreen OAE & ABR Screener

Audiometric Techniques Program in Audiology and Communication Sciences Pediatric Audiology Specialization

Coding Fact Sheet for Primary Care Pediatricians

Plural Publishing Newsletter Spring Otoacoustic Emissions (OAEs): A 30-Year Perspective. James W. Hall III, Ph.D. University of Florida

Ear Exam and Hearing Tests

Experience the power of integration

Proceedings of Meetings on Acoustics

AA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

The registration testing for audiometric device in CFDA

Diagnostic Impedance & Audiometry in one solution

Transcription:

Diagnostic OAE-Tympanometry Combination System by Maico Diagnostics ERO SCAN Pro 3 tests with one probe fit Electronic medical records (EMR), ready Link results to patient's electronic chart with EroScan Pro software EroScan Pro Pictured www.maico-diagnostics.com

Otoacoustic Emissions (OAEs) Otoacoustic emissions are sounds that are produced by the cochlea (outer hair cells) and can be measured in the ear canal. When sound passing through the ear canal reaches the cochlea, the vibration stimulates thousands of tiny hair cells. This creates a byproduct that can be detected and measured: otoacoustic emissions. OAEs only occur in a normal cochlea with normal hearing sensitivity. If there is damage to the outer hair cells, which produces hearing loss, then OAEs will not be present. In general, OAEs will be present if hearing is at 30 db or better. www.maico-diagnostics.com

ERO SCAN Pro Why are OAEs Clinically Valuable? OAEs are widely applied in pediatric and adult patient populations for a variety of reasons. OAEs are an index of outer hair cell activity. Because of their dependence on normal cell metabolism, almost all insults to the cochlea first affect the outer hair cells. For example, vascular, noise damage or hypoxic cochlear deficits will be invariably reflected by reduced OAE amplitude. Therefore, assuming normal middle ear function, OAE abnormalities provide early and compelling evidence of cochlear (outer hair cell) dysfunction. Additional clinical advantages of OAE are: Brief test time: Usually less than a minute per ear Relatively simple technique: Little training is required Objective: Unaffected by attention, cognition, cooperation Independent of age: OAEs can even be recorded from newborn infants Ear specific: Test results for each ear Frequency specific: Information for many individual frequencies Test up to 10 frequency bands as close as 100 Hz apart Clinical Applications of OAEs Given their sensitivity to cochlear dysfunction, and the clinical advantages, it s not surprising that OAEs are useful in auditory assessment of diverse patient populations. One of the most common applications of OAEs is screening persons at risk for hearing impairment. OAE screening outcome is generally described as either Pass or Refer. A pass outcome is reported when OAEs are present ( 6 db above the noise floor) for the majority of test frequencies. Although the presence of OAEs does not always indicate normal hearing sensitivity, a pass outcome rules out serious degrees of hearing loss. A refer OAE screening outcome should be viewed as a clear risk factor for hearing loss that could affect communication. Patients who yield a refer outcome for OAE screening should be referred for diagnostic hearing assessment, and possible audiological or medical management.

OAE Say Hello to Tympanometry Ero Scan Pro As a non-invasive test, tympanometry can quickly and easily be performed on patients of any age, from infants to adults. The objectivity of tympanometry means the results are not dependant upon a response from the patient. Choose test to run (ie, linked OAE & Tymp) OAE PASS Result Advantages of Tympanometry: Tymp PASS Result Middle Ear evaluations Objective test method Test patients of any age Documented test results OAE REFER Result Features of Ero Scan Pro: Print to thermal paper, PDF, or 8.5 x 11 PC printer Customizable settings and protocols Optional patient management database Sequenced protocols permit a full test battery Review Result EroScan Pro Screen Shots www.maico-diagnostics.com

The EroScan Pro is the only system that has the capability of linking DP & TE protocols for diagnostic cochlear mapping. ERO SCAN Pro The only OAE system that has the option of adding tympanometry in both 226Hz and 1000Hz, probe tones. DPOAE/ TEOAE/TYMP OAE and Tympanometry are completed in as little as 20 seconds Intuitive interface for fast, easy operation Advanced diagnostic capabilities One probe fit, three tests; (CPT codes) 92567, 92587 & 92588. Run three tests without taking probe out of the patient s ear Portability The EroScan Pro hand-held unit runs on batteries and allows you to move from room to room. The probe also makes it easy to maneuver around the head of your patient to attain a tight ear seal. Protocols Normative data included Approved, verified protocols can be customized Open templates that can be customized Multiple customizable test protocols Managing Data and Print Results Managing patient reports and tracking data is easy with the optional database. Selectable print options, are easily commanded by the push of one button. Compatible with EMR via PDF 8.5 x 11 full color PDF Full page to PC printer Customize report with office header information Thermal paper print Protocols Screen Pictured

ERO SCAN Pro Reimbursement Otoacoustic emissions are reimbursable using the Current Procedural Terminology (CPT) codes. To date, health care reimbursement has varied in terms of cost per test but no problems have arisen if the appropriate codes are utilized. The most typical CPT code for OAE screening is: 92587: Evoked otoacoustic emissions; limited (single stimulus level, either transient or distortion product). This is the most typical code and would be considered a screening code or sampling of the cochlea. 92588: Comprehensive or diagnostic evaluation (comparison of transient and/or distortion product otoacoustic emissions at multiple levels and frequencies). This is for diagnostic OAE testing, or mapping of the cochlea. 92567: Tympanometry Conforms to IEC 601-1. ERO SCAN is a trademark of ETYMOTIC RESEARCH, INC. Printed in the USA U.S. Patent #5,954,669; 6,299,584; 6,702,758; 6,056,698; 6,331,164; 7,050,592; 7,269,262,164 Other Patents Pending www.maico-diagnostics.com

Parts & Accessories The ERO SCAN Pro OAE System is available in three configurations: Screener, Standard and Clinical System Printer Kit #589-10 Cradle #589-2 USB #1025-2088 Printer Paper #586-8 (adhesive or non-adhesive) PRODUCT FEATURE SCREENER STANDARD CLINICAL Internal OAE Probe Y Y Y External OAE Probe Y Y Y External Tymp Probe Option Optional Optional Optional DPOAE/TEOAE DP or TE DP or TE DP and TE SYSTEM FEATURES SCREENER STANDARD CLINICAL Sequenced Protocols Y Y Y Quick-print to PDF Y Y Y Quick-print to PC Printer (8.5x11) Y Y Y Completely Portable Y Y Y Memory (# tests) Maximum 350 350 350 Save Tests by Patient # Y Y Y Print Graphics and Numeric Data Y Y Y Date and Time on Printout Y Y Y Tests All Ages Y Y Y Printer Optional Optional Optional OAE External Probe #589-1 Tymp/OAE External Probe #589-3 Patient Management Database w/ support for uploadng patient names to instrument Optional Optional Optional OAE FEATURES SCREENER STANDARD CLINICAL OAE Frequency Range (Hz) 2-5 DP 1.5-4 TE 1.5-12 DP 0.7-4 TE 1.5-12 DP 0.7-4 TE Maximum number of Test Frequencies or Bands Reported 4 DP 6 TE 10 DP 10 TE 10 DP 10 TE Probe Tips (internal) #589-4 Probe Tips (external) #589-5 Default Pass/Refer Y Y Y # of OAE Test Protocols 2 Included 5 Included 5 DP, 5 TE Included Customizable Pass Criteria N Y Y Customizable Test Protocols N Y Y Customizable by frequency/range: stimulus intensity, P1/P2 ratio, averaging time, SNR for pass, minimum OAE amplitude Not Customizable Y Y Eartip Kit #589-7 Patient Management Software (Includes Patient Management Manual) #589PM Carrying Case (optional accessory) #589-11 Ero Scan Pro Operation DVD #5577 Selectable Averaging Time Y Y Y TYMPANOMETRY OPTION SCREENER STANDARD CLINICAL Probe Tone 226 Hz Y Y Y Probe Tone 1000 Hz Y Y Y Default PASS/REFER Indicator & Box Y (226 Hz) Y Y Hide/Show PASS/REFER Indicator & Box Y Y Y Customizable Pass Criteria N Y Y # of Tymp Protocols 2 (226 Hz) 1 (1000 Hz) 2 (226 Hz) 1 (1000 Hz) 2 (226 Hz) 1 (1000 Hz)

Innovation, Continuity, Reliability, MAICO Product Line: Screening Audiometers Diagnostic Audiometers Middle Ear Analyzers OAE Test Systems PC Compatible Products Newborn Hearing Screening This brochure contains only a small segment of the comprehensive product portfolio of MAICO. To find out more about other solutions, please contact us at: Telephone: 888-941-4201 REV 9/10 MAICO Diagnostics 7625 Golden Triangle Drive Eden Prairie, MN 55344 Tel: 888-941-4201 Fax: 952-903-4100 Web: www.maico-diagnostics.com