Transdental Photo-activation Technique: Hardness and Marginal Adaptation of Composite Restorations Using Different Light Sources

Similar documents
Influence of the light curing unit and thickness of residual dentin on generation of heat during composite photoactivation

Effect of the Curing Method and Composite Volume on Marginal and Internal Adaptation of Composite Restoratives

Influence of. on Conversion and Microleakage

Effect of. Conversion Degree and Hardness of Dual-cured Resin Cement

Effect of Time and Polymerization Cycle on the Degree of Conversion of a Resin Composite

Development of dental resin luting agents based on Bis-EMA4: bond strength evaluation

Effect of Light Curing Units on Marginal Adaptation and Hardness of Class II Composite Resin Restorations

Effect of light-curing method and indirect veneering materials on the Knoop hardness of a resin cement

Effect of Different Initial Light Intensity by the Soft-Start Photoactivation on the Bond Strength and Knoop Hardness of a Dental Composite

WHY PLASMA TECHNOLOGY?

Effect of Different Modes of Light Modulation on the Bond Strength and Knoop Hardness of a Dental Composite

Effect of light irradiation distance during intermediate. polymerization on depth of cure and hardness of. indirect composite

Pulse-delay Curing: Influence of Initial Irradiance and Delay Time on Shrinkage Stress and Microhardness of Restorative Composites

Clinical report. Drs Paul and Alexandre MIARA and F. CONNOLLY COMPOSITE POSTERIOR FILLINGS. How to control. layering? 8 - Dentoscope n 124

Impact of adhesive and photoactivation method on sealant integrity and polymer network formation

Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location

Comparison of Quartz-Tungsten-Halogen, Light-emitting Diode, and Plasma Arc Curing Lights

The Influence of Temperature on the Efficacy of Polymerization of Composite Resin

EFFECT OF CURING LIGHT DISTANCE ON MICROLEAKAGE AND COMPRESSIVE STRENGTH OF PEDIATRIC COMPOSITE RESTORATIONS

Effect of Reduced Exposure Times on the Microhardness of Nanocomposites Polymerized by QTH and Second-generation LED Curing Lights

For the Perfect Class V and All Cervical Area Gingival Margins when Placing Direct Composites, Create an Injection Molding Matrix

shrink less than 1 %

Influence of Curing Rate of Resin Composite on the Bond Strength to Dentin

Effect of various grit burs on marginal integrity of resin composite restorations

The Influence of C-factor, Flexural Modulus and Viscous Flow on Gap Formation in Resin Composite Restorations

Influence of. in Resin Composite

A Step-by-Step Approach to

Results:Mean microleakage score of group G1, G2 and G3 was 2.86 ± 1.43, 1.86 ± 1.65 and 2.46 ± 1.50 respectively.

Charisma Topaz PRODUCT INFORMATION. The three - in - one composite solution. Heraeus Kulzer Nordic AB

Near-UV light detection

shrink less than 1 %

Metal-Free Restorations PROCEDURES FOR POSTERIOR DIRECT & SEMI-DIRECT COMPOSITE RESTORATIONS D I D I E R D I E T S C H I. For.

Microleakage around zirconia crowns after ultrasonic scaling around their margin

Effect of Cavosurface Angle on Dentin Cavity Adaptation of Resin Composites

Filtek LS Low Shrink Posterior Restorative System Case 1: Cusp build-up

Effectiveness of Second-generation Light-emitting Diode (LED) Light Curing Units

Effects of Different Temperatures and Storage Time on the Degree of Conversion and Microhardness of Resin-based Composites

The effect of a plastic-wrapped LED light curing unit and curing distance variances on diametral tensile strength of composite resin

No Prep And Minimal Prep Veneers

Original Article. in depth, 4 mm in mesiodistal width and 3 mm occlusogingival

< 1% shrinkage! * new record: Low Shrink Posterior Restorative. volumetric. The fi rst direct posterior composite to achieve less than 1 % shrinkage.

ABOUT BULK FILL COMPOSITE RESINS

2011 Dental Materials Clinical Dentistry Survey

Hardening of a dual-cure resin cement using QTH and LED curing units

How to build up the perfect tooth

Change the Way You Think About Bulk Fill Composites

The Sof-Lex Finishing and Polishing System 3ESPE

Pulpal Protection: bases, liners, sealers, caries control Module A: Basic Concepts

Quantifying Light Energy Delivered to a Class I Restoration

TECHNICAL GUIDE. For use with CEREC

Influence of the Internal Conditioning of Indirect Restorations of Resin Composite in Relation to Microleakage Using LEDs and QTH Units

ARTICLE IN PRESS. dental materials xxx (2010) xxx xxx. available at journal homepage:

***Handout*** Adhesive Dentistry Harald O. Heymann, DDS MEd Dentin Bonding Rewetting/Desensitization

Post-gel Shrinkage Strain and Degree of Conversion of Preheated Resin Composite Cured Using Different Regimens

Comparison of Temperature Changes in the Pulp Chamber Induced by Various Light Curing Units, In Vitro

Contamination of Composite Resin by Glove Powder and Saliva Contaminants: Impact on Mechanical Properties and Incremental Layer Debonding

LMArte. Sculpt masterpieces

Effect of the composite photoactivation mode. mode on microtensile bond strength and Knoop microhardness.

Impact of Photodynamic Therapy Applied by FotoSan on Periodontal Tissues Clinical Parameters

Marketed in US as: Individual Attention Only

Preparation and making fillings Class V., III., IV.

CLINICAL GUIDE CLINICAL GUIDE. by DR. NOBORU TAKAHASHI BY DR. NOBORU TAKAHASHI

Principle Investigators: Overview of Study Methods: Dr. John Burgess Dr. Carlos Muñoz

SDR has proven reliability in high C-factor cavities 2

Surface/Interface Morphology and Bond Strength to Glass Ceramic Etched for Different Periods

Adper Easy Bond. Self-Etch Adhesive. Technical Product Profile

Clinical Technique/Case Report

Effect of Composite Insertion Technique on Cuspal Deflection Using an In Vitro Simulation Model

Evaluation of a Second-Generation LED Curing Light

Colourf low. light cured dental flowable composite

Howard E. Strassler, DMD University of Maryland School of Dentistry

Press Release. Press Contact. The concept for Class II restoration Delicate preparation, rapid procedure and reliable results

Effect of Composite Insertion Technique on Cuspal Deflection Using an In Vitro Simulation Model

EVALUATION OF INTERNAL ADAPTATION OF CLASS V RESIN COMPOSITE RESTORATIONS USING THREE TECHNIQUES OF POLYMERIZATION

J Lasers Med Sci 2016 Summer;7(3):

Bulk Fill PERFECTION STRESS DEPTH STATES: The New Esthetics

The Cavity Fighting ProActive Crown

Effects of Different Curing Lights on Microleakage in Resin- Based Composite Restorations

Management of Inadequate Margins and Gingival Recession Presenting as Tooth Sensitivity

Clinical Time Required and Internal Adaptation in Cavities

Wear Rates of Resin Composites

Effect of Tooth Bleaching on Bond Strength of Enamel-Dentin Cavities Restored With Siloraneand Dimethacrylate-based Materials

Tetric Evo Line. A composite for every indication.

Amaris. You want outstanding esthetic restorations with the WOW-EFFECT

Adper Scotchbond SE. Self-Etch Adhesive. Self-etch technology that s visibly better

Evaluation of Curing Light Distance on Resin Composite Microhardness and Polymerization

EFFECT OF LIGHT CURING UNIT ON RESIN-MODIFIED GLASS-IONOMER CEMENTS: A MICROHARDNESS ASSESSMENT

2. Gap closure and replacement of the missing tooth 35 with directly modelled bridge region 34-36

Research Article Push-Out Bond Strength of Restorations with Bulk-Fill, Flow, and Conventional Resin Composites

Vickers Hardness of Composite Resins Cured with LED and QTH Units

Introduction to Layering with Filtek Supreme Plus Universal Restorative. Filtek. Supreme Plus Universal Restorative

Cutting instruments. Instruments

A Study of Microleakage in Class II Composite Restorations Using Four Different Curing Techniques

values is of great interest.

Filtek. Bulk Fill. Posterior Restorative. One. and done.

Black class I. and II. composite fillings Dental matrix systems and its use DR. KÁROLY BARTHA

In-Depth Polymerization of a Self-Adhesive Dual- Cured Resin Cement

etching systems with mixing self-etching Etch & Rinse systems 3-year Water-storage Class-V Dentin Margin Integrity of Adhesives

MDJ Evaluation the effect of eugenol containing temporary Vol.:9 No.:2 2012

Transcription:

Operative Dentistry, 2008, 33-4, 421-425 Transdental Photo-activation Technique: Hardness and Marginal Adaptation of Composite Restorations Using Different Light Sources EB Alves RCB Alonso GM Correr AB Correr RR de Moraes MAC Sinhoreti L Correr-Sobrinho Clinical Relevance The association of transdental and direct photo-activation of composite restorations might improve marginal adaptation, while not being detrimental to composite hardness. Eliane Bemerguy Alves, DDS, MS, PhD, Department of Restorative Dentistry, Dental Materials Area, Piracicaba Roberta Caroline Bruschi Alonso, DDS, MS, PhD, Department of Restorative Dentistry, Dental Materials Area, Piracicaba Gisele Maria Correr, DDS, MS, PhD, Department of Restorative Dentistry, Dental Materials Area, Piracicaba Américo Bortolazzo Correr, DDS, MS, graduate student, Rafael Ratto de Moraes, DDS, MS, graduate student, Mário Alexandre Coelho Sinhoreti, DDS, MS, PhD, professor, *Lourenço Correr-Sobrinho, DDS, MS, PhD, professor, *Reprint request: Av Limeira, 901 13414-903, Piracicaba, SP, Brazil; e-mail: sobrinho@fop.unicamp.br DOI: 10.2341/07-109 SUMMARY This study investigated the influence of different light sources associated with a transdental photoactivation technique on the marginal adaptation and hardness of composite restorations. Cavities (3 mm wide x 3 mm long x 1.5 mm in deep) were prepared on flattened bovine dentin and filled with Z250 composite (3M ESPE). Nine groups (n=10) were defined according to the curing technique (direct; transdental photo-activation through 1 mm of enamel and 2 mm of dentin; mixed transdental + direct) and light source (QTH XL2500, 3M ESPE; PAC Apollo 95E, DMD; LED Ultrablue Is, DMC) combination. Marginal

422 Operative Dentistry adaptation was evaluated using a dye staining method, and the percentage of stained margins was recorded. Knoop Hardness readings were made across the transversal section of the fillings. Data were submitted to two-way ANOVA and Tukey s test (p 0.05). For margin analysis, although none of the curing conditions provided perfect adaptation, the mixed technique showed lower gap formation. No significant differences were detected between the transdental and other techniques, and no significant differences were detected among the light sources. For hardness, the direct technique showed slightly greater hardness than the mixed technique. Also, the mixed technique yielded greater hardness than the transdental technique. Among the light sources, the LED showed greater hardness than the PAC; whereas, no significant differences between the QTH and other sources were detected. The mixed technique might improve the marginal adaptation of restorations, while not being detrimental to composite hardness. INTRODUCTION Resin composites are the material of choice for direct restorative procedures. However, during constrained polymerization, these materials undergo volumetric shrinkage during setting, which may generate stresses within the material and at the tooth-filling interface. 1 This phenomenon could disrupt bonding between the composite and cavity walls or cause cohesive failure of either the restoration or the surrounding tooth structure 1 and may cause marginal failure of the restorations. Numerous light-curing approaches have been proposed in order to attenuate the resulting shrinkage stress and reduce the formation of marginal gaps. 2-3 These strategies reduced the curing rate, allowing more time for the material to flow during setting. 4 Previous studies 2-3 have shown that marginal integrity might be improved using activation at low irradiance without compromising the final conversion. 5 An additional approach to reducing the irradiance level is to activate the material through the dental tissues (transdental technique, TDT). 6 This technique, which was introduced based on the common belief that the direction of shrinkage vectors was towards the polymerization light, attempted to change the direction of the vectors towards the bonded walls. However, it was further demonstrated that the shrinkage vectors actually develop toward the bonded walls, irrespective of the light position. 7 Nonetheless, the TDT could be effective in modifying the kinetics of polymerization, as a reduction in light intensity of up to 70% may occur when light passes through the dental structure. 8 This reduction would propitiate the maintenance of bond integrity, working as a modulated photo-curing method. In addition to curing methods, different light-curing units (LCUs) are available. Light-emitting diodes (LED) and plasma arc (PAC) were introduced as alternatives to traditional quartz-tungsten-halogen (QTH) LCUs. However, little is known about the influence of these different light sources when using the TDT. Therefore, this study investigated the influence of different light sources using direct (DT), mixed (MT) or TDT curing techniques on the marginal adaptation and hardness of composite restorations. The tested hypothesis was that TDT would reduce the formation of gaps without decreasing hardness, regardless of the light source tested. METHODS AND MATERIALS The roots of bovine incisors were sectioned 1 mm below the cementum-enamel junction and the teeth were embedded in polystyrene resin. The buccal surface of each tooth was ground using a water-cooled mechanical polisher (APL-4, Arotec, Cotia, ) with 80-, 180-, 320- and 600-grit SiC papers (Norton SA, São Paulo, ) to expose a flat dentin area at least 6 mm in diameter. Cavity Preparations The mesial and distal faces of each tooth were sectioned in order to standardize a width of 7 mm for all specimens. Cavities (3 mm wide x 3 mm long x 1.5 mm deep) were prepared on the central area of the flattened surfaces, defining a thickness of 2 mm for the proximal dentin walls. The preparations were made using air/water-cooled #1094 cylindrical diamond burs (KG Sorensen, Barueri, ). The internal walls of each cavity were perpendicular to the top and bottom surfaces, with round angles as defined by the bur shape, presenting a C-factor of 3. Additionally, a 1 mm thick enamel slice was obtained by removing the dentin portion of the buccal surface of a bovine incisor. Wetpolishing the enamel slice was carried out with 200- and 400-grit SiC papers, and this slice was used for the TDT. Restorative Procedures The specimens were randomly assigned to nine groups (n=10), as described in Table 1. Filtek Z250 resin composite (3M ESPE, St Paul, MN, USA) shade A2 and the Single Bond adhesive system (3M ESPE) were used according to the manufacturer s instructions. The composite was inserted into the cavity in a single increment. After light-activation, the specimens were stored in distilled water at 37 C for 24 hours and wet-polished with 600- and 1200-grit SiC papers. Figure 1 shows positioning of the enamel slice during the TDT. For this technique, light-curing was performed through the 1 mm thick enamel slice and the 2 mm thick proximal

Alves & Others: Transdental Photo-activation of Composite Restorations 423 Table 1: Description of the Light Sources and Curing Techniques Light Source* Curing Technique** Photo-Activation Protocol Radiant Exposure QTH Direct 20 second top 12 J/cm 2 Transdental 20 second mesial + 20 second distal 1.2 J/cm 2 Mixed 20 second mesial + 20 second distal + 20 second top 13.2 J/cm 2 LED Direct 20 second top 10 J/cm 2 Transdental 20 second mesial + 20 second distal 1.6 J/cm 2 Mixed 20 second mesial + 20 second distal + 20 second top 11.6 J/cm 2 PAC Direct 9 second top 12 J/cmv Transdental 9 second mesial + 9 second distal 1 J/cm 2 Mixed 9 second mesial + 9 second distal + 9 second top 13 J/cm 2 *QTH XL2500 (3M ESPE), with irradiance of 600 mw/cm 2 ; LED Ultrablue Is (DMC, São Carlos, ), with irradiance of 500 mw/cm 2 ; PAC Apollo 95E (DMD, Westlake, CA, USA), with irradiance of 1340 mw/cm 2. Measurements were made using a handheld radiometer. **Transdental technique photo-activation through 1 mm of enamel slice and 2 mm of mesial/distal dentin wall. The irradiance actually reaching the composite was 30mW/cm 2 for QTH, 40mW/cm 2 for LED, and 55mW/cm 2 for PAC. Figure 1. Experimental design of the study. Bovine incisors were embedded in polystyrene resin and a flat ground surface in dentin was obtained. Both proximal faces were sectioned using a diamond saw to obtain 2 mm-thick dentin walls. 1) Standardized cavities were prepared on the central area of the flattened surfaces. 2) After insertion of the composite, different curing techniques and light sources were tested. 3) A 1 mm-thick enamel slice was positioned between the light guide tip and the proximal dentin wall for the transdental technique. dentin walls. A handheld radiometer (Demetron, Danbury, CT, USA) was used to measure irradiance of the LCUs and the irradiance transmitted through a 2 mm thick dentin specimen covered with the enamel slice. These values were used to calculate the radiant exposure for each curing technique-light source combination (Table 1). Table 2: Average Percentage (Standard Deviation) of Marginal Gap Formation Light Source Curing Technique LED QTH PAC Total Direct 13.3 (5.9) 19.8 (6.4) 17.5 (5.3) 16.8 a Transdental 12.3 (3.0) 9.7 (2.6) 6.2 (1.5) 9.4 ab Mixed 6.3 (2.8) 8.2 (1.8) 7.7 (2. 2) 7.4 b Total 10.6 A 12.5 A 10.5 A Same capital letter in the row indicates no significant difference for light source, and same small letter in the column indicates no significant difference for curing technique (p>0.05). Marginal Adaptation Analysis After air-drying the samples, a drop of 1% acid red propylene glycol solution (Caries Detector, Kuraray, Osaka, Japan) was placed on the margins for 20 seconds. The samples were rinsed with water, air-dried and digital images were obtained. The length of time for staining along the margins was measured using Image Tool 2.0 software (UTHSC, San Antonio, TX, USA). Marginal adaptation (%) was calculated as the ratio of the stained margin by the total length of the margin. Data were submitted to two-way ANOVA and Tukey s test (p 0.05). Hardness Evaluation Each specimen was cut in half through the center of the restoration. The cervical portion was wet-polished with 400-, 600- and 1200-git SiC papers. Knoop indentations were made across the section of the composite with an indenter (HMV-2, Shimadzu, Tokyo, Japan), using a 50g load for 15 seconds. Three readings were performed at 0.5 mm deep and three at 1 mm deep. The Knoop Hardness number (KHN) for each specimen was recorded as the average of the six indentations. The data were submitted to two-way ANOVA and Tukey s test (p 0.05). RESULTS Table 2 presents the results of the marginal adaptation analysis. Significant differences among the light-curing techniques were detected (p=0.009); whereas, the factor light source (p=0.774) and the interaction between the technique and light source (p=0.692) were not significant. No curing techniquelight source combination provided a perfect marginal adaptation. However,

424 Operative Dentistry Table 3: Knoop Hardness Means (Standard Deviation) Light Source Curing Technique LED QTH PAC Total Direct 95.3 (1.1) 96.2 (1.4) 87.4 (1.9) 93.0 a Transdental 88.6 (1.6) 87.1 (2.1) 86.5 (1.9) 87.4 b Mixed 63.2 (1.3) 56.5 (3.0) 58.3 (3.3) 59.3 c Total 82.4 A 79.9 AB 77.4 B Same capital letters indicate no significant differences for light source, and same small letters indicate no significant differences for curing technique (p>0.05). MT yielded a decrease in gap formation compared with DT (p<0.05), regardless of the light source. No significant difference was detected between TDT and the other techniques. Table 3 shows the results of the hardness analysis. Significant differences were detected among the curing techniques (p<0.001) and light sources (p=0.033) but not for the interaction between them (p=0.152). DT showed greater hardness than both TDT (p<0.01) and MT (p<0.05). Also, MT yielded greater hardness than TDT (p<0.05). For the light source, LED showed greater hardness compared with the PAC (p<0.05), but there was no significant difference between QTH and other light sources. DISCUSSION It is known that continuous irradiance at high intensity generates high contraction stress 9 and gap formation. 2-3 Indeed, the poorest marginal adaptation was found for DT. This technique also showed the greatest hardness, which is probably related to a higher degree of conversion and shrinkage, which might have also accounted for increasing gap formation. On the other hand, it could be expected that the lower initial irradiance provided by TDT would interfere with gap formation. Nonetheless, only MT provided better marginal adaptation than direct curing. Therefore, the tested hypothesis cannot be confirmed. The lower gap formation observed for MT could be explained by a reduction in irradiance when light passes through the dental structure. Indeed, previous studies 10-11 reported that photo-activation at reduced irradiance is more efficient than trying to guide the shrinkage vectors in order to preserve marginal integrity, as the direction of vectors is determined by boundary conditions. 1 Therefore, MT seemed to work as a soft-start polymerization. Also, the current results suggest that an increase in exposure time leads to smaller gap formation. However, when activation was carried out through just the dental structure, no improvement in marginal adaptation was detected. The hardness outcomes might explain this phenomenon, as significantly softer polymers were detected for TDT. When compared to the other techniques, the radiant exposure for TDT was noticeably lower, as a function of the significant reduction in irradiance for the light transmitted through enamel and dentin, probably leading to a lower degree of conversion. During polishing procedures, irregularities around the restoration margins could have been produced because of low polymerized material increasing marginal staining. This outcome highlights a proper curing of the composite. which might be essential for the long-term success of the restorations. In order to assess marginal adaptation, a dye staining method was used. 12 Although depth of penetration or gap width are usually evaluated, the presence of gaps, regardless of their width or depth, might be the first sign of restoration failure. 12 However, due to the limitations of in vitro analyzes, it is difficult to predict whether the observation of dye-stained margins could indicate poor clinical performance. Nonetheless, the presence of gaps might lead to interfacial leakage, degradation of the bonding layer or even extrinsic staining. Therefore, it would be advisable to use a curing method capable of improving the adaptation of fillings. On the other hand, with respect to the light source, no significant differences in gap formation were detected, regardless of the photo-activation technique used. This result is probably related to the similar radiant exposure that controls conversion and shrinkage. Therefore, it seems that, for gap formation, the light source presents less influence than the activation technique. In addition, the LED source showed significantly greater hardness than the PAC. In the current study, a nine second exposure time was used for activation with PAC, instead of the three seconds recommended by its manufacturer, in order to ensure adequate composite cure. Nonetheless, despite the similar radiant exposure, a slight reduction in hardness, compared to the LED source, was observed. This might be related to the fact that the output light spectrum of the LCU also has critical importance for polymerization potential. 13 Therefore, the narrower emission spectrum of LED lights, which is better correlated with the spectral absorbance peak of camphorquinone, could improve their curing ability. Moreover, a slight reduction in hardness was verified for MT when compared with DT. An attempt to explain this outcome considers that the initial exposure at lowlight intensity for TDT might result in the formation of short, low-molecular weight polymer chains, with less cross-linking 4 interfering with the mechanical properties of the composite. 13 Nevertheless, considering the

Alves & Others: Transdental Photo-activation of Composite Restorations 425 magnitude of the difference verified between DT and MT, and also between the LED and PAC sources, it is difficult to predict whether this could have significant influence on the clinical practice. In summary, the current results show that a photocuring technique that combines initial activation through the dental structure and final exposure from the top surface of the restoration might reduce the formation of gaps, while not being detrimental to composite hardness, irrespective of the light source. Thereby, this technique could be encouraged in clinical practice. Nonetheless, it is important to highlight the fact that high-intensity lights should be used, as irradiance through the dental structure would be markedly reduced. CONCLUSIONS The association between transdental and direct curing techniques could reduce the formation of marginal gaps, regardless of the light source, while not being detrimental to composite hardness; The transdental photo-activation technique might produce no significant beneficial effect on the marginal adaptation of composite restorations, while significantly interfering with material hardness; The different light sources (QTH, LED and PAC) showed no influence on the marginal adaptation of composite restorations, while the LED unit yielded greater hardness than PAC. (Received 18 June 2007) References 1. Feilzer AJ, de Gee AJ & Davidson CL (1990) Quantitative determination of stress reduction by flow in composite restorations Dental Materials 6(3) 167-171. 2. Alonso RC, Correr GM, Cunha LG, De Moraes Souto Pantoja CA, Puppin-Rontani RM & Sinhoreti MA (2007) Modulated photoactivation methods-effect on marginal and internal gap formation of restorations using different restorative composites Journal of Biomedical Materials Research Part B Applied Biomaterials 82(2) 346-351. 3. Alonso RC, Cunha LG, Correr GM, Cunha Brandt W, Correr-Sobrinho L & Sinhoreti MA (2006) Relationship between bond strength and marginal and internal adaptation of composite restorations photocured by different methods Acta Odontologica Scandinavica 64(5) 306-313. 4. Schneider LF, Moraes RR, Cavalcante LM, Sinhoreti MA, Correr-Sobrinho L & Consani S (2008) Cross-link density evaluation through softening tests: Effect of ethanol concentration Dental Materials 24(2) 199-205 Epub 2007 June 4. 5. Sakaguchi RL & Berge HX (1998) Reduced light energy density decreases post-gel contraction while maintaining degree of conversion in composites Journal of Dentistry 26(8) 695-700. 6. Belvedere PC (1995) Controlling shrinkage using TEP: Trans-enamel polymerization Dentistry Today 14(4) 92, 94-97. 7. Versluis A, Tantbirojn D & Douglas WH (1998) Do dental composites always shrink toward the light? Journal of Dental Research 77(6) 1435-1445. 8. Prati C, Chersoni S, Montebugnoli L & Montanari G (1999) Effect of air, dentin and resin-based composite thickness on light intensity reduction American Journal of Dentistry 12(5) 231-234. 9. Sakaguchi RL, Wiltbank BD & Murchison CF (2004) Contraction force rate of polymer composites is linearly correlated with irradiance Dental Materials 20(4) 402-407. 10. Hofmann N, Hiltl O, Hugo B & Klaiber B (2002) Guidance of shrinkage vectors vs irradiation at reduced intensity for improving marginal seal of Class V resin-based composite restorations in vitro Operative Dentistry 27(5) 510-515. 11. Losche GM (1999) Marginal adaptation of Class II composite fillings: Guided polymerization vs reduced light intensity The Journal of Adhesive Dentistry 1(1) 31-39. 12. Caroline Bruschi Alonso R, Maria Correr G, Gonçalves Cunha L, Flávia Sanches Borges A, Maria Puppin-Rontani R & Alexandre Coelho Sinhoreti M (2006) Dye staining gap test: An alternative method for assessing marginal gap formation in resin composite restorations Acta Odontologica Scandinavica 64(3) 141-145. 13. St-Georges AJ, Swift EJ, Thompson JY & Heymann HO (2003) Irradiance effects on the mechanical properties of universal hybrid and flowable hybrid resin composites Dental Materials 19(5) 406-413.