EXTERNAL HEX INTERNAL HEX NTERNAL. ENDOPORE Product Catalog

Similar documents
Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

SwissPlant Prosthetic Catalog. SwissPlant

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

HEXAGON Implant System

NARROW DIAMETER implant

- RESTORATIVE PRODUCT CATALOG

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD

Product Catalog. Since 1985» Simple. Predictable. Profitable.

RePlant System Prosthetic Catalog

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free

Legacy Prosthetic Catalog

4766 Research Dr. San Antonio, TX insightdentalsystems.com

CATALOG. Since 1985» Simple. Predictable. Profitable.

External Hex 4.1 & 5.0 platform

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

SimpleLine II Surgical / Prosthesis Manual

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

Legacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4

NARROW DIAMETER implant

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

US Implant System 2013 PROSTHETIC PROCEDURE

InterActive System Catalog

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

Implant Phase Flow Chart

Hex-Lock Abutment System. Restorative Manual

For the oral rehabilitation

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

SS Implant System 2013 PROSTHETIC PROCEDURE

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte

The REAL Mini Implant

cement-retained single crowns using cementable abutments

INTERNAL HEX Implant System

TRINON. Index. Index. Overview Page 4. Catalogue

SICHERHEITSDATENBLATT

Restoring Straumann implants. with Locator abutments.

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

How something small, can make such a big difference!! Your best choice in overdenture

NARROW DIAMETER implant

Steri-Oss Compatible Components

FBR PATENTEDV-TPS EARLY LOADING FBR PATENTED SUCCESS PATENTED PITT-EASY EARLY LOADING PROSTHETIC VARIETY. Product Catalog SUCCESS

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

OT EQUATOR CASTABLE Single Attachment for Overdentures

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

ESTHETIC LINE implant

Xive. Product Catalog

Product Catalog July 2017

SuperLine & Implantium Surgical / Prosthesis Manual

Product Catalog August 2018

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm

product catalog

RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED

N E W S M I L E S E V E R Y D AY

User Manual Complete Prosthetic Kit (CPK)

CHECK-UP Determination of Impression type & Method after implant placement

For Threadloc 3.75 (implant discontinued - components available in Branemark section) For Spline SD, RD & WD (only Locator components available)

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

UFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

SuperLine & Implantium Surgical / Prosthesis Manual

Smarter Thinking. Simpler Design. Prima TM. Product Catalog

Astra Tech Implant System. Product catalog. OsseoSpeed TX

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

Osteotome inserts kit, angled. Impression tube (open tray) Selection abutment kit / Selection measurement post. Bar base PMMA & Finisher

Product catalog. ASTRA TECH Implant System EV

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

GINGIVAL LEVEL implant

INTERNAL HEX ( ps) PLATFORM SHIFT PRESERVATION OF BONE NEVER LOOKED BETTER

Step-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System

SCREW-RETAINED RESTORATION LINE. THE MULTI UNIT ABUTMENT SYSTEM ON STRAIGHT and tilted IMPLANTS

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

TRI-TAPERED Implant System

isy indications and techniques

Straight Octagon Abutment for Tissue Level Implant

FOR PROFESSIONALS. Product Catalogue. Cochlear Vistafix 3 System A BONE ANCHORED PROSTHETIC SOLUTION

DENTAL IMPLANT SYSTEM. Product Catalog. October 2015

InterActive TM System. Catalog

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

Quick start Prosthetics

Ankylos. Product Catalog

MICRODENT EXTERNAL CONNECTION PRODUCTS GUIDE EXTERNAL CONNECTION IMPLANTS IMPLANTOLOGY SYSTEMS. Product presentation. Digital information

introduction to BioHorizons prosthetics

Product Catalog. Others make Implants to sell... Tatum Surgical makes Implants to treat your Patients.

Innovative Präzision Made in Germany

Product catalog. ASTRA TECH Implant System EV

Swish System Catalog

prosthetic technique manual

RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP

TS Implant System 2013 PROSTHETIC PROCEDURE

Including product catalog

3M ESPE MDI. Mini Dental Implants. Quick Order Guide

Type 1. Type 2. Straumann Bone Level. The L-Series abutments are compatible with» L-SERIES «

NR Line Product Catalog

Contents. Contents Design Features. Packaging. Implant Range. System Hardware.

CAMLOG IMPLANT SYSTEM PRODUCT CATALOG

Osteoconductive S.L.A. Surface. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation.

MiNi Overdenture Fixture

» For multi-unit restorations -

Smarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants

Product Catalog. Since 1985» Simple. Predictable. Profitable.

Transcription:

Osteotome PROCEDURES perfect NTERNAL PERFECT SURFACE ENDOPORE Product Catalog INTERNAL HEX PerfeCT SURFACE EXTERNAL HEX Implant Placement Procedure

ENDOPORE

Table of Contents ENDOPORE Contents Endopore Implants with internal connection 4 Endopore Implants with internal connection for one-stage surgery 5 Case Planning Chart Crown and Bridge Restorations 7 Cover Screws 7 Cementable s 7 ECO System 8 Octabutment System Overdenture Restorations 9 Locator System 10 Dalla Bona System 10 O-Ring System Endopore Implants with internal Hex 11 Endopore Implants for one-stage and two-stage surgery 12 Case Planning Chart Crown and Bridge Restorations 14 Cover Screws 14 Healing s 15 Transfer Copings 15 Implant Analogs 15 Retaining Screws 16 Hexed s 16 Angled s 17 UCLA s Overdenture Restorations 18 Locator System 19 O-Ring System 19 Dalla Bona System 20 UMA System Endopore Implants with external Hex 21 Endopore External Hex Connection implants for one-stage and two-stage surgery 23 Case Planning Chart Crown and Bridge Restorations 26 Cover Screws 26 Healing s 27 Transfer Copings 28 Implant Analogs 28 Retaining Screws 29 Hexed s 30 Angled s 30 Temporary Titanium s 31 UCLA s Overdenture Restorations 32 Locator System 32 O-Ring System 33 Dalla Bona System 34 UMA System 36 Prosthetic Instrumentation Surgery 38 Endopore Surgical Kits 39 Endopore Surgical Instrumentation 42 Articles in alphabetical order 3 Internet All print material released by Oraltronics is available online, too. Product catalogs and insertion brochures as well as information for patients or current case reports it takes you only 4 steps to get to the print product desired. Just click under www.oraltronics.com

ENDOPORE Internal connection Endopore Implants with internal connection for one-stage surgery 4 The Endopore implants have a standard Morse Taper implant-to-abutment interface and are supplied in both 4.1 mm and 5.0 mm implant diameters, each having a 4.8 mm abutment platform diameter. This allows both the 4.1 mm and 5.0 mm diameter implants to accept the same prosthetic components. Each implant diameter is available with a 1.8 mm transgingival collar. A 1 mm low profile cover screw is packaged with each implant. AP* TC* Length 4.8 mm AP* Implant Ø 4.1 mm 1.8 mm TC* Length 4.8 mm 1.8 mm 7 mm 01S-7I1.8 4.8 mm 1.8 mm 9 mm 01S-9I1.8 4.8 mm 1.8 mm 12 mm 01S-12I1.8 Implant Ø 5.0 mm 4.8 mm 1.8 mm 5 mm 01WS-5I1.8 * AP Platform Ø ** TC Transgingival Collar Diameter 4.8 mm 1.8 mm 7 mm 01WS-7I1.8 4.8 mm 1.8 mm 9 mm 01WS-9I1.8 4.8 mm 1.8 mm 12 mm 01WS-12I1.8

Internal connection BICORTICAL ENDOPORE Case Planning Chart One-stage Surgery Angled Cementable Straight Cementable ECO Octabutment 5 Crown Bridge Locking Non-Locking Crown Bridge Bar

ENDOPORE Internal connection Case Planning Chart 6 One-stage Surgery Locator System O-Ring System Dalla Bona System Impression Stage Laboratory Processing Final Restoration Overdenture

Internal connection BICORTICAL ENDOPORE Crown and Bridge Restorations Cover Screws Length Cover Screw (replacement) A 1 mm cover screw is packaged with each implant. 1 mm 02S-1HS 2 mm 02S-2HS 3 mm 02S-3HS 4 mm 02S-4HS Cementable s Length Straight Cementable s 4.0 mm 05S-4.0FS 5.5 mm 05S-5.5FS 7.0 mm 05S-7.0FS 7 Angled Cementable s Angle 15 Angle 25 05S-15FA 05S-25FA 15 ECO System ECO and Cap for cementable restorations Length 5.0 mm (7.0 mm with cap) ECO Analog 05S-5ABUT/WC 06S-ANALOG 7.0 mm 5.0 mm ECO ECO Analog ECO Coping Indexed ECO Coping Non Indexed 06S-COPING/I 06S-COPING ECO Coping Indexed ECO Coping Non Indexed

ENDOPORE Internal connection Octabutment System The Octabutment System is used for all procedures where a removable prosthesis is required, or where a working model incorporating an abutment analog is desired. Octabutment Octabutment Cap with Screw 07S-0010 07S-2100 Octabutment Cap with screw Transfer Coping with Guide Pin for Octabutment Octabutment Analog 07S-0090 07S-0015 Transfer Coping Octabutment Analog 8 Temporary for Octabutment locking Temporary for Octabutment non-locking Temporary abutments include an octabutment retaining screw. 07S-0303 07S-0353 locking non-locking Plastic Coping for Octabutment locking 07S-0203 Plastic Coping for Octabutment non-locking 07S-0253 locking non-locking Note: Plastic copings include an octabutment retaining screw. Octabutment Retaining Screw 07S-0053 Accessories Insertion Tip for the ECO and Cementable 07S-0176 Insertion Tip for Octabutment 07S-0175 Driver Housing Driver Tip 0.05 Hex Tip 07-0190 06-TWHT Insertion Tip Insertion Tip for Octabutment Driver Housing 0.05 Hex Tip Hex Tip 12.5 mm

Internal connection BICORTICAL ENDOPORE Overdenture Restorations Locator s Impl. Ø mm Collar The Locator abutment is an attachment with a self-aligning feature. This feature will aid patients in seating their denture and eliminate additional wear from improper seating. With the Locator s minimal vertical height, it is ideal where interocclusal space is limited. This abutment can also accommodate up to 40 between implants. 4.1/ 5.0 mm 0.73 mm 8950 4.1/ 5.0 mm 2 mm 8951 4.1/ 5.0 mm 3 mm 8952 4.1/ 5.0 mm 4 mm 8953 4.8 mm Platform Locator Attachments Locator Attachments 9 Locator Male Processing Package 2 Sets, each Set includes: 1 Processing Replacement Male 8515, 1 Replacement Male 8524/ 8527/8529, 1 Spacer white Locator Replacement Male clear, 4 Pack Locator Light Retention Replacement Male pink, 4 Pack 8519 8524 8527 Locator Extended Range Replacement Male green, 4 Pack Locator Extra Light Extended Range Male red, 4 Pack Locator Black Processing Replacement Male 4 Pack 8547 8548 8515 Locator Extra Light Retention Replacement Male, blue, 4 Pack 8529 Locator Parallel Post 4 Pack 8517 Locator Impression Coping 4 Pack 8505 Locator Female Analog 5 mm Diameter. 4 Pack 8516 Locator Parallel Post Locator Impression Coping Female Analog Ø 5 mm Angle Measurement Guide 9530 Angle Measurement Guide Locator Core Tool 8393 Locator Driver 15 mm length 21 mm length 8926 8927 20 Ncm Torque Wrench (Ncm Newton centimeters) 06-TW20

ENDOPORE Internal connection Overdenture Restorations Dalla Bona and O-Ring Systems The ORS and the Dalla Bona abutments lie flush with the top of the implant when the abutments are inserted into the Endopore One-Stage implants. Note Please refer to pages 32 33 for Dalla Bona System and O-Ring System. 10 Dalla Bona System Each Dalla Bona System includes a titanium male abutment, a brass abutment analog, a titanium female with a PVC ring and a spacer. 07S-3000 O-Ring System Each O-Ring System includes a titanium male abutment and an ORS lab kit which includes a brass abutment analog, metal housing, 3 red O-Rings and 3 white O-Rings. 07S-4000 Note The red O-Ring is used for laboratory set-up and the white O-Ring is used for the finished overdenture. Accessories Driver Housing 07-0190 Driver for ORS and Dalla Bona System 07-0140 Dalla Bona Activating Tool An instrument used to increase the retention of an attachment 07-1017 Dalla Bona Deactivating Tool An instrument used to reduce the retention of an attachment 07-1018

Internal hex BICORTICAL ENDOPORE Endopore Implants with internal hex for one-stage and two-stage surgery Endopore Implants with internal hex are supplied in both 4.1 mm and 5.0 mm implant platforms. A low profile cover screw is packaged with each implant. 11 SCR* Length SCR* Length Implant Ø 4.1 mm 2 mm 7 mm 01l-7I2 2 mm 9 mm 01l-9I2 2 mm 12 mm 01l-12I2 Implant Ø 5.0 mm Diameter * SCR Smooth Coronal Region 2 mm 7 mm 01Wl-7I2 2 mm 9 mm 01Wl-9I2 2 mm 12 mm 01Wl-12I2

ENDOPORE Internal hex Case Planning Chart Flared Healing Straight Healing 12 One- and twostage Surgery Flared Transfer Straight Transfer Impression Stage Coping Assembly Coping Assembly Flared Hexed Angled Hexed Angled Hexed Straight Hexed Hexed UCLA Non-Hexed UCLA Laboratory Processing 15 25 Final Restoration Crown Bridge

Internal hex BICORTICAL ENDOPORE Case Planning Chart One- and twostage Surgery Straight Healing 13 Impression Stage Locator System O-Ring System (ORS) Dalla Bona System Laboratory Processing Final Restoration Overdenture

ENDOPORE Internal hex Crown and Bridge Restorations Cover Screws Impl. Ø mm Cover Screw (replacement) A low profile cover screw is packaged with each implant. 4.1 mm 02I-CS 5.0 mm 02WI-CS Healing s Impl. Ø mm Length Width 14 Straight Healing s The straight healing abutment is used in all situations except where an expanded gingival cuff is desired. 4.1 mm 3 mm 4.1 mm 02B-3HS 4.1 mm 5 mm 4.1 mm 02B-5HS 4.1 mm 7 mm 4.1 mm 02B-7HS 5.0 mm 3 mm 5.0 mm 02WB-3HS 5.0 mm 5 mm 5.0 mm 02WB-5HS 5.0 mm 7 mm 5.0 mm 02WB-7HS Flared Healing s The use of a flared healing abutment allows the gingiva to heal around this expanded profile, where a more natural emergence profile is preferred. 4.1 mm 4 mm 5.5 mm 02B-4H 4.1 mm 6.5 mm 5.5 mm 02B-6.5H 5.0 mm 4 mm 6.4 mm 02WB-4H 5.0 mm 6.5 mm 6.4 mm 02WB-6.5H Width Width Length Length Straight Healing Flared Healing

Internal hex BICORTICAL ENDOPORE Transfer Copings The shape of the transfer coping matches the shape of the corresponding healing abutment and this allows the profile of the gingival cuff to be accurately reproduced in the working model. Transfer Copings Impl. Ø mm Length Straight Transfer Copings for use with straight healing abutments, incl. screw Flared Transfer Copings for use with flared healing abutments incl. screw Transfer Coping Screw, long for optional use with transfer copings, when an open tray technique is used 4.1 mm 11 mm 06I-CTCA/S 5.0 mm 11 mm 06WI-CTCA/S 4.1 mm 11 mm 06I-CTCA/F 5.0 mm 11 mm 06WI-CTCA/F 4.1 mm 16 mm 06B-TC/SL 5.0 mm 16 mm 06B-TC/SL 15 Straight Transfer Coping Flared Transfer Coping Transfer Coping Screw Implant Analogs Impl. Ø mm Length Qty. Implant Analogs Material: Stainless Steel 4.1 mm 9 mm 1 06I-PIA 5.0 mm 9 mm 1 06WI-PIA Retaining Screws (replacement) Impl. Ø mm for use with hexed and UCLA abutments Titanium Alloy Replacement Screw Gold Alloy Replacement Screw 4.1/ 5.0 mm 05B-2RS 4.1/ 5.0 mm 05B-2RS/G All abutments are packaged with a titanium retaining screw.

ENDOPORE Internal hex Hexed s Impl. Ø mm Length Collar These abutments are used for cement retained crown or bridge restorations. Straight Hexed s Retaining screw included The straight hexed abutment has a parallel sided transgingival collar. 4.1 mm 7 mm 1.5 mm 05I-7FN 4.1 mm 9 mm 3.5 mm 05I-9FN 4.1 mm 11 mm 5.5 mm 05I-11FN 5.0 mm 7 mm 1.5 mm 05WI-7FN 5.0 mm 9 mm 3.5 mm 05WI-9FN 5.0 mm 11 mm 5.5 mm 05WI-11FN Length Collar 16 Flared Hexed s Retaining screw included The flared hexed abutment is designed for restorations requiring a natural emergence profile. 4.1 mm 8.5 mm 2 mm 05I-8.5UN 5.0 mm 8.5 mm 2 mm 05WI-8.5UN Collar Length Angled s Impl. Ø mm Length Angle Angled Hexed s Retaining screw included Angled abutments compensate for large divergences in implant alignment. Angled guide pins are available in the Prosthetic Instrumentation section of this catalog. 4.1 mm 11 mm 15 05I-15FA 4.1 mm 11 mm 25 05I-25FA 5.0 mm 11 mm 15 05WI-15FA 5.0 mm 11 mm 25 05WI-25FA 15 25

Internal hex BICORTICAL ENDOPORE UCLA s UCLA abutments provide a foundation to which wax can be added to shape a screwretained crown or bridge or a custom abutment. See the Prosthetic Instrumentation section for the lapping tool used to polish the cast surface that will mate with the implant. A reamer is also available to clean out the retaining screw hole in the casting. Gold base abutments have machined surfaces and will not require finishing with these tools. Hexed UCLA abutments should be used for custom abutments and for supporting crowns as they will resist the rotational forces associated with single tooth screw retained restorations. UCLA s Impl. Ø mm UCLA Plastic s Retaining screw included Hexed 4.1 mm 06I-UCLA/H 5.0 mm 06WI-UCLA/H Non-Hexed UCLA Gold Base s Non-Ceramic Alloy Retaining screw included Hexed 4.1 mm 06I-UCLA 5.0 mm 06WI-UCLA 4.1 mm 06I-UCLA/H/GNC 5.0 mm 06WI-UCLA/H/GNC 17 Non-Hexed 4.1 mm 06I-UCLA/GNC 5.0 mm 06WI-UCLA/GNC Important The melting range is 1,400 1,490 C (2,550 2,710 F), refer to package instructions for further details. UCLA Plastic Hexed UCLA Plastic Non-Hexed UCLA Gold Base Hexed UCLA Gold Base Non-Hexed

ENDOPORE Internal hex Overdenture Restorations Locator s Impl. Ø mm Collar 18 The Locator abutment is an attachment with a self-aligning feature. This feature will aid patients in seating their denture and eliminate additional wear from improper seating. With the Locator s minimal vertical height, it is ideal where interocclusal space is limited. This abutment can also accommodate up to 40 between implants. 4.1 mm 0 mm 8145 4.1 mm 1 mm 8146 4.1 mm 2 mm 8147 4.1 mm 3 mm 8148 4.1 mm 4 mm 8149 4.1 mm 5 mm 8150 5.0 mm 1 mm 8164 5.0 mm 2 mm 8165 5.0 mm 3 mm 8166 5.0 mm 4 mm 8167 5.0 mm 5 mm 8168 5.0 mm 6 mm 8169 Locator Attachments Locator Attachments Locator Male Processing Package 2 Sets, each Set includes: 1 Processing Replacement Male 8515, 1 Replacement Male 8524/ 8527/8529, 1 Spacer white Locator Replacement Male clear, 4 Pack Locator Light Retention Replacement Male pink, 4 Pack 8519 8524 8527 Locator Extended Range Replacement Male green, 4 Pack Locator Extra Light Extended Range Male red, 4 Pack Locator Black Processing Replacement Male 4 Pack 8547 8548 8515 Locator Extra Light Retention Replacement Male, blue, 4 Pack 8529 Locator Parallel Post 4 Pack 8517 Locator Impression Coping 4 Pack 8505 Locator Female Analog 4.1 mm Diameter. 4 Pack 5.0 mm Diameter. 4 Pack 8530 8516 Locator Parallel Post Locator Impression Coping Female Analog Ø 4.1 mm Female Analog Ø 5.0 mm Angle Measurement Guide 9530 Angle Measurement Guide Locator Core Tool 8393 Locator Driver 15 mm length 21 mm length 8926 8927 20 Ncm Torque Wrench 06-TW20

Internal hex BICORTICAL ENDOPORE O-Ring System (ORS) Impl. Ø mm Collar Length O-Ring System The red O-Ring is used for laboratory set-up and the white O-Ring is used for the finished overdenture. The O-Ring abutment system can accommodate up to 5 degrees of divergence between implants. Each O-Ring System includes a titanium male abutment and an ORS lab kit which includes a brass abutment analog, metal housing, 3 red O-Rings and 3 white O-Rings. Note Please refer to page 32 for O-Ring System. Ø 4.1 1 mm 4 mm 04I-1ORS Ø 4.1 2 mm 5 mm 04I-2ORS Ø 4.1 3 mm 6 mm 04I-3ORS Ø 4.1 4 mm 7 mm 04I-4ORS Ø 4.1 5 mm 8 mm 04I-5ORS Ø 4.1 6 mm 9 mm 04I-6ORS Ø 4.1 7 mm 10 mm 04I-7ORS Ø 5.0 1 mm 4 mm 04WI-1ORS Ø 5.0 2 mm 5 mm 04WI-2ORS Ø 5.0 3 mm 6 mm 04WI-3ORS Ø 5.0 4 mm 7 mm 04WI-4ORS Ø 5.0 5 mm 8 mm 04WI-5ORS Ø 5.0 5 mm 9 mm 04WI-6ORS O-Ring Accessories O-Ring Lab Kit Metal Housing 06-ORS 07-0044 White O-Rings Package of 10 Dalla Bona System Impl. Ø mm Collar Length 06-O/ORS 19 Dalla Bona System The Dalla Bona abutment is a ball & socket type connector. Its spherical design allows up to 15 degrees divergence between the abutments. Each Dalla Bona System includes a titanium male abutment, a brass abutment analog, a titanium female with a PVC ring and a spacer. Note Please refer to page 33 for Dalla Bona System. Dalla Bona Accessories Dalla Bona Replacement Female Cap Includes a brass abutment analog, a titanium female with a PVC ring and a spacer. Ø 4.1 1 mm 4 mm 04I-1DB Ø 4.1 2 mm 5 mm 04I-2DB Ø 4.1 3 mm 6 mm 04I-3DB Ø 4.1 4 mm 7 mm 04I-4DB Ø 4.1 5 mm 8 mm 04I-5DB Ø 4.1 6 mm 9 mm 04I-6DB Ø 4.1 7 mm 10 mm 04I-7DB Ø 5.0 1 mm 4 mm 04WI-1DB Ø 5.0 2 mm 5 mm 04WI-2DB Ø 5.0 3 mm 6 mm 04WI-3DB Ø 5.0 4 mm 7 mm 04WI-4DB Ø 5.0 5 mm 8 mm 04WI-5DB Ø 5.0 6 mm 9 mm 04WI-6DB Ø 5.0 7 mm 10 mm 04WI-7DB 07-1012 Dalla Bona Activating Tool An instrument used to increase the retention of an attachment. 07-1017 Dalla Bona Deactivating Tool An instrument used to reduce the retention of an attachment. 07-1018

ENDOPORE Internal hex UMA System Impl. Ø mm Collar UMA System s The UMA (Universal Modification ) system is used for screw retained restorations where it is desired to have the points of attachment superior to the soft tissue. Where there is insufficient clearance to use a UMA or when a sub-gingival separation is desired, a UCLA abutment can be used to achieve separation of the restoration at the implant level. The UMA is a transmucosal collar that should be secured to the implant with 30 Ncm of torque. The UMA screw used to secure the restoration to the abutment is packaged with each UMA plastic coping. A 0.05 hex driver is used to secure the screw which should only be tightened to 20 Ncm. Ø 4.1 2.0 mm 02I-2.0UMA Ø 4.1 3.0 mm 02I-3.0UMA Ø 4.1 4.0 mm 02I-4.0UMA Ø 4.1 5.0 mm 02I-5.0UMA Ø 4.1 6.0 mm 02I-6.0UMA Ø 4.1 7.0 mm 02I-7.0UMA Ø 4.1 8.0 mm 02I-8.0UMA Ø 5.0 3.0 mm 02WI-3.0UMA Ø 5.0 4.0 mm 02WI-4.0UMA Ø 5.0 5.0 mm 02WI-5.0UMA Ø 5.0 6.0 mm 02WI-6.0UMA Note Please refer to pages 34 35 for UMA System. 20

External hex BICORTICAL ENDOPORE Endopore Implants with external hex for one-stage and two-stage surgery Endopore Implants with external hex are compatible with a wide variety of prosthetic products for crown and bridge and overdenture restorations including UCLA, UMA, Dalla Bona, Overdenture and O-Ring Systems. All implants are packaged with colour coded labels that identify their diameters. All prosthetic components must be matched to the diameter of implant to which they are to be connected. labels have the same color coding as the corresponding implants. 21

ENDOPORE External hex Endopore Implants with external hex 22 The Endopore External Hex Connection implants are available in three diameters: 3.5 mm, 4.1 mm and 5.0 mm. A low profile cover screw is packaged with each implant. The 4.1 mm and 5.0 mm diameter are available with a 1 mm or 2 mm smooth coronal region. The 3.5 mm diameter implant is available in a 1 mm smooth coronal region. SCR* Length 3.5 mm diameter implant The 3.5 mm diameter implant is packaged in a red labeled box (01M-range). This implant has a 0.9 mm high x 2.0 mm flat-toflat hex and a UNF thread. 4.1 mm diameter implant The 4.1 mm diameter implants with the industry standard hex are packaged in green labeled boxes (01B-range). These implants have a 0.7 mm high x 2.7 mm flat-to-flat hex and a metric thread. 5.0 mm diameter implant The 5.0 mm diameter implants are packaged in turquoise labeled boxes (01WB-range). These implants have a 0.9 mm high x 2.7 mm flat-to-flat hex and metric thread. Diameter SCR* 1 mm Length SCR* Length Implant Ø 3.5 mm 1 mm 9 mm 01M-9I1 Implant Ø 4.1 mm * SCR Smooth Coronal Region Diameter Diameter SCR* 2 mm Length 1 mm 7 mm 01B-7I1 2 mm 7 mm 01B-7I2 1 mm 9 mm 01B-9I1 2 mm 9 mm 01B-9I2 1 mm 12 mm 01B-12I1 2 mm 12 mm 01B-12I2 Implant Ø 5.0 mm 1 mm 5 mm 01WB-5I1 1 mm 7 mm 01WB-7I1 2 mm 7 mm 01WB-7I2 1 mm 9 mm 01WB-9I1 2 mm 9 mm 01WB-9I2 1 mm 12 mm 01WB-12I1 2 mm 12 mm 01WB-12I2

External hex BICORTICAL ENDOPORE Case Planning Chart One- and twostage Surgery Flared Healing Straight Healing 23 Impression Stage Flared Transfer Coping Assembly Straight Transfer Coping Assembly Flared Hexed Angled Hexed Angled Hexed Straight Hexed Hexed UCLA Non-Hexed UCLA Laboratory Processing 15 25 Final Restoration Crown Bridge

ENDOPORE External hex Case Planning Chart One- and twostage Surgery Straight Healing 24 Impression Stage Locator System O-Ring System Dalla Bona System Laboratory Processing Final Restoration Overdenture

External hex BICORTICAL ENDOPORE Case Planning Chart UMA Healing Cap One- and twostage Surgery Standard UMA System 25 Impression Stage Single Crown Bridge, Bar and Clip O-Ring Step 1 Step 1 Step 2 Step 2 Laboratory Processing Final Restoration Crown Bridge Bar Overdenture

ENDOPORE External hex Crown and Bridge Restorations Cover Screws Impl. Ø mm Cover Screw (replacement) A low profile cover screw is packaged with each implant. 3.5 mm 02M-CS 4.1 mm 02B-CS 5.0 mm 02WB-CS Healing s Impl. Ø mm Length Width 26 Straight Healing s The straight healing abutment is used in all situations except where an expanded gingival cuff is desired. Ø 3.5 3 mm 3.5 mm 02M-3HS Ø 3.5 5 mm 3.5 mm 02M-5HS Ø 3.5 7 mm 3.5 mm 02M-7HS Ø 4.1 3 mm 4.1 mm 02B-3HS Ø 4.1 5 mm 4.1 mm 02B-5HS Ø 4.1 7 mm 4.1 mm 02B-7HS Ø 5.0 3 mm 5.0 mm 02WB-3HS Ø 5.0 5 mm 5.0 mm 02WB-5HS Ø 5.0 7 mm 5.0 mm 02WB-7HS Flared Healing s The use of a flared healing abutment allows the gingiva to heal around this expanded profile, where a more natural emergence profile is preferred. Ø 3.5 4 mm 4.7 mm 02M-4H Ø 3.5 6.5 mm 4.7 mm 02M-6.5H Ø 4.1 4 mm 5.5 mm 02B-4H Ø 4.1 6.5 mm 5.5 mm 02B-6.5H Ø 5.0 4 mm 6.4 mm 02WB-4H Ø 5.0 6.5 mm 6.4 mm 02WB-6.5H Width Width Length Length Straight Healing Flared Healing

External hex BICORTICAL ENDOPORE Transfer Copings Impl. Ø mm Length Width The shape of the transfer coping matches the shape of the corresponding healing abutment and this allows the profile of the gingival cuff to be accurately reproduced in the working model. Straight Transfer Copings for use with straight healing abutments Ø 3.5 11 mm 3.5 mm 06M-CTCA/S Ø 3.5 16 mm 3.5 mm 06M-CTCA/SL Ø 4.1 11 mm 4.1 mm 06B-CTCA/S Ø 4.1 16 mm 4.1 mm 06B-CTCA/SL Ø 5.0 11 mm 5.0 mm 06WB-CTCA/S Ø 5.0 16 mm 5.0 mm 06WB-CTCA/SL Flared Transfer Copings for use with flared healing abutments Ø 3.5 11 mm 4.7 mm 06M-CTCA/F Ø 4.1 11 mm 5.5 mm 06B-CTCA/F Ø 4.1 16 mm 5.5 mm 06B-CTCA/FL Ø 5.0 11 mm 6.4 mm 06WB-CTCA/F 27 Transfer Coping Screw, long for optional use with transfer copings, when an open tray technique is used Closed Impression Ø 3.5 16 mm 06-TC/SL Ø 4.1 16 mm 06B-TC/SL Ø 5.0 16 mm 06B-TC/SL Straight Transfer Copings 11 mm Flared Transfer Copings 11 mm marking marking marking marking marking marking Ø 3.5 Ø 4.1 Ø 5.0 Ø 3.5 Ø 4.1 Ø 5.0 Open Impression Transfer Coping Screw for optional use 16 mm marking Ø 3.5 Ø 4.1 Ø 5.0

ENDOPORE External hex Implant Analogs Impl. Ø mm Length Qty. Implant Analogs Material: Aluminum Ø 3.5 9 mm 1 06M-IA/1 Ø 3.5 9 mm 5 06M-IA Ø 4.1 9 mm 1 06B-IA/1 Ø 4.1 9 mm 5 06B-IA Ø 5.0 9 mm 1 06WB-IA/1 Ø 5.0 9 mm 5 06WB-IA Implant Analog Material: Stainless Steel Ø 3.5 9 mm 1 06M-PIA Ø 3.5 9 mm 5 06M-PIA/5 Ø 4.1 9 mm 1 06B-PIA Ø 4.1 9 mm 5 06B-PIA/5 Ø 5.0 9 mm 1 06WB-PIA Ø 5.0 9 mm 5 06WB-PIA/5 28 Aluminum Stainless Steel Ø 3.5 Ø 4.1 Ø 5.0 Ø 3.5 Ø 4.1 Ø 5.0 Retaining Screws Impl. Ø mm Retaining Screw (replacement) for use with hexed and UCLA abutments Titanium Alloy Replacement Screw Ø 3.5 Ø 4.1/5.0 05-2RS 05B-2RS Gold Alloy Replacement Screw Ø 3.5 Ø 4.1/5.0 05M-2RS/G 05B-2RS/G All abutments are packaged with a titanium retaining screw.

External hex BICORTICAL ENDOPORE Hexed s Impl. Ø mm Length Collar These abutments are used for cement retained crown or bridge restorations. Straight Hexed s Retaining screw included The straight hexed abutment has a parallel sided transgingival collar. These abutments are available in both regular (grooved FS) and thick wall (not grooved FN) versions. Ø 3.5 7 mm 1.5 mm 05M-7FS Ø 3.5 7 mm 1.5 mm 05M-7FN Ø 3.5 9 mm 3.5 mm 05M-9FN Ø 4.1 7 mm 1.5 mm 05B-7FS Ø 4.1 7 mm 1.5 mm 05B-7FN Ø 4.1 9 mm 3.5 mm 05B-9FS Ø 4.1 9 mm 3.5 mm 05B-9FN Ø 4.1 11 mm 5.5 mm 05B-11FS Ø 4.1 11 mm 5.5 mm 05B-11FN Ø 5.0 7 mm 1.5 mm 05WB-7FS Ø 5.0 7 mm 1.5 mm 05WB-7FN Ø 5.0 9 mm 3.5 mm 05WB-9FS Ø 5.0 9 mm 3.5 mm 05WB-9FN Ø 5.0 11 mm 5.5 mm 05WB-11FS Ø 5.0 11 mm 5.5 mm 05WB-11FN 29 Length Length Collar FN FS Flared Hexed s Retaining screw included The flared hexed abutment is designed for restorations requiring a natural emergence profile. These abutments are available in both regular (grooved UF) and thick wall (not grooved UN) versions. Ø 3.5 8.5 mm 2 mm 05M-8.5UN Ø 3.5 9 mm 2 mm 05M-9UF Ø 4.1 8.5 mm 2 mm 05B-8.5UN Ø 4.1 10 mm 2 mm 05B-10UF Ø 4.1 11.5 mm 3.5 mm 05B-11.5UN Ø 5.0 8.5 mm 1.5 mm 05WB-8.5UN Ø 5.0 8 mm 1.5 mm 05WB-8UF Ø 5.0 10.5 mm 3.5 mm 05WB-10.5UN Length Length Collar UN UF

ENDOPORE External hex Hexed s Impl. Ø mm Length Angle Angled Hexed s Retaining screw included Angled abutments compensate for large divergences in implant alignment. Angled guide pins are available in the Prosthetic Instrumentation section of this catalog, pages 36 37. Ø 3.5 11 mm 15 05M-15FA Ø 3.5 11 mm 25 05M-25FA Ø 4.1 11 mm 15 05B-15FA Ø 4.1 11 mm 25 05B-25FA Ø 5.0 11 mm 15 05WB-15FA Ø 5.0 11 mm 25 05WB-25FA 15 25 Temporary Titanium s Impl. Ø mm 30 Temporary s Retaining screw included Hexed Temporary Ø 3.5 Ø 4.1 Ø 5.0 05M-TEMP/H 05B-TEMP/H 05WB-TEMP/H Non-Hexed Temporary Ø 3.5 Ø 4.1 Ø 5.0 05M-TEMP 05B-TEMP 05WB-TEMP

External hex BICORTICAL ENDOPORE Crown and Bridge Restorations UCLA s UCLA abutments provide a foundation to which wax can be added to shape a screw-retained crown or bridge or a custom abutment. See the Prosthetic Instrumentation section for the lapping tool used to polish the cast surface that will mate with the implant. A reamer is also available to clean out the retaining screw hole in the casting. Gold base abutments have machined surfaces and will not require finishing with these tools. Hexed UCLA abutments should be used for custom abutments and for supporting crowns as they will resist the rotational forces associated with single tooth screw retained restorations. Non-hexed UCLA abutments should be used for supporting screw retained bridges. UCLA s Impl. Ø mm UCLA Plastic s Retaining screw included Hexed, green Hexed, yellow Hexed, blue Ø 3.5 Ø 4.1 Ø 5.0 06M-UCLA/H 06B-UCLA/H 06WB-UCLA/H 31 Non-Hexed, white Non-Hexed, white Non-Hexed, yellow Ø 3.5 Ø 4.1 Ø 5.0 06M-UCLA 06B-UCLA 06WB-UCLA Hexed Non-Hexed UCLA Gold Base s, metal alloy for porcelain fusing Retaining screw included Important The melting range is 1232 1260 C (2250 2300 F), refer to package instructions for further details. Hexed Ø 3.5 Ø 4.1 Ø 5.0 06M-UCLA/H/G 06B-UCLA/H/G 06WB-UCLA/H/G Non-Hexed Ø 3.5 Ø 4.1 Ø 5.0 06M-UCLA/G 06B-UCLA/G 06WB-UCLA/G Hexed Non-Hexed UCLA Gold Base s, alloy not for porcelain fusing Retaining screw included Hexed Gold Base UCLA Important The melting range is 1400 1490 C (2550 2710 F), refer to package instructions for further details. Ø 3.5 Ø 4.1 Ø 5.0 06M-UCLA/H/GNC 06B-UCLA/H/GNC 06WB-UCLA/H/GNC Non-Hexed Gold Base UCLA Ø 3.5 Ø 4.1 Ø 5.0 06M-UCLA/GNC 06B-UCLA/GNC 06WB-UCLA/GNC Hexed Non-Hexed

ENDOPORE External hex Overdenture Restorations Locator System Impl. Ø mm Collar 32 The Locator abutment is an attachment with a self-aligning feature. This feature will aid patients in seating their denture and eliminate additional wear from improper seating. With the Locator s minimal vertical height, it is ideal where interocclusal space is limited. This abutment can also accommodate up to 40 between implants. Note Please refer to pages 9 and 18 for Locator System and its components. 3.5 mm 1 mm 8851 3.5 mm 2 mm 8852 3.5 mm 3 mm 8853 3.5 mm 4 mm 8854 4.1 mm 0.73 mm 8681 4.1 mm 2 mm 8682 4.1 mm 3 mm 8683 4.1 mm 4 mm 8684 5.0 mm 1.35 mm 8691 5.0 mm 2 mm 8691 5.0 mm 3 mm 8691 5.0 mm 4 mm 8691 O-Ring System (ORS) Impl. Ø mm Collar Length O-Ring System The O-Ring abutment system can accommodate up to 5 degrees of divergence between implants. Each O-Ring System includes a titanium male abutment and an ORS lab kit which includes a brass abutment analog, metal housing, 3 red O-Rings and 3 white O-Rings. Length Note The red O-Ring is used for laboratory set-up and the white O-Ring is used for the finished overdenture. O-Ring Accessories O-Ring Lab Kit Metal Housing White O-Rings Package of 10 Collar Ø 3.5 1 mm 4 mm 04M-1ORS Ø 3.5 2 mm 5 mm 04M-2ORS Ø 3.5 3 mm 6 mm 04M-3ORS Ø 3.5 4 mm 7 mm 04M-4ORS Ø 3.5 5 mm 8 mm 04M-5ORS Ø 4.1 1 mm 4 mm 04B-1ORS Ø 4.1 2 mm 5 mm 04B-2ORS Ø 4.1 3 mm 6 mm 04B-3ORS Ø 4.1 4 mm 7 mm 04B-4ORS Ø 4.1 5 mm 8 mm 04B-5ORS Ø 4.1 6 mm 9 mm 04B-6ORS Ø 4.1 7 mm 10 mm 04B-7ORS Ø 5.0 1 mm 4 mm 04WB-1ORS Ø 5.0 2 mm 5 mm 04WB-2ORS Ø 5.0 3 mm 6 mm 04WB-3ORS Ø 5.0 4 mm 7 mm 04WB-4ORS Ø 5.0 5 mm 8 mm 04WB-5ORS Ø 5.0 6 mm 9 mm 04WB-6ORS 06-ORS 07-0044 06-O/ORS

External hex BICORTICAL ENDOPORE Dalla Bona System Impl. Ø mm Collar Length Dalla Bona System The Dalla Bona abutment is a ball & socket type connector. Its spherical design allows up to 15 degrees divergence between the abutments. Each Dalla Bona System includes a titanium male abutment, a brass abutment analog, a titanium female with a PVC ring and a spacer. Length Collar Dalla Bona Plus Accessories Ø 3.5 1 mm 4 mm 04M-1DB Ø 3.5 2 mm 5 mm 04M-2DB Ø 3.5 3 mm 6 mm 04M-3DB Ø 3.5 4 mm 7 mm 04M-4DB Ø 3.5 5 mm 8 mm 04M-5DB Ø 3.5 6 mm 9 mm 04M-6DB Ø 3.5 7 mm 10 mm 04M-7DB Ø 4.1 1 mm 4 mm 04B-1DB Ø 4.1 2 mm 5 mm 04B-2DB Ø 4.1 3 mm 6 mm 04B-3DB Ø 4.1 4 mm 7 mm 04B-4DB Ø 4.1 5 mm 8 mm 04B-5DB Ø 4.1 6 mm 9 mm 04B-6DB Ø 4.1 7 mm 10 mm 04B-7DB Ø 5.0 1 mm 4 mm 04WB-1DB Ø 5.0 2 mm 5 mm 04WB-2DB Ø 5.0 3 mm 6 mm 04WB-3DB Ø 5.0 4 mm 7 mm 04WB-4DB Ø 5.0 5 mm 8 mm 04WB-5DB Ø 5.0 6 mm 9 mm 04WB-6DB Ø 5.0 7 mm 10 mm 04WB-7DB 33 Dalla Bona Plus Keeping the same benefits as the Dalla Bona System, the Dalla Bona Plus female attachment is a gold insert that can be easily replaced and adjusted with Dalla Bona Plus Activating/Deactivating Tool. Includes a brass abutment analog, a titanium cap with a gold female insert, and a spacer. Dalla Bona Plus Activating/Deactivating Tool An instrument used to increase and reduce the retention of an attachment. 07-0480 07-0489 Dalla Bona Accessories Dalla Bona Replacement Female Cap Includes a brass abutment analog, a titanium female with a PVC ring and a spacer. 07-1012 Dalla Bona Activating Tool An instrument used to increase the retention of an attachment. 07-1017 Dalla Bona Deactivating Tool An instrument used to reduce the retention of an attachment. 07-1018

ENDOPORE External hex UMA System Impl. Ø mm Collar 34 UMA System s The UMA (Universal Modification ) system is used for screw retained restorations where it is desired to have the points of attachment superior to the soft tissue. Where there is insufficient clearance to use a UMA or when a sub-gingival separation is desired, a UCLA abutment can be used to achieve separation of the restoration at the implant level. The UMA is a transmucosal collar that should be secured to the implant with 30 Ncm of torque. The UMA screw used to secure the restoration to the abutment is packaged with each UMA plastic coping. A 0.05 hex driver is used to secure the screw which should only be tightened to 20 Ncm. Standard UMA System The upper diameter for all UMA System s is 3.85 mm. Ø 3.5 3.5 mm 02M-3.5UMA Ø 3.5 4.5 mm 02M-4.5UMA Ø 3.5 5.5 mm 02M-5.5UMA Ø 3.5 6.5 mm 02M-6.5UMA Ø 4.1 2.5 mm 02B-2.5UMA Ø 4.1 3.0 mm 02B-3.0UMA Ø 4.1 4.0 mm 02B-4.0UMA Ø 4.1 5.0 mm 02B-5.0UMA Ø 4.1 6.0 mm 02B-6.0UMA Ø 4.1 7.0 mm 02B-7.0UMA Ø 4.1 8.0 mm 02B-8.0UMA Ø 5.0 3.5 mm 02WB-3.5UMA Ø 5.0 4.5 mm 02WB-4.5UMA Ø 5.0 5.5 mm 02WB-5.5UMA Ø 5.0 6.5 mm 02WB-6.5UMA Collar UMA Healing Cap UMA Healing Cap 2 mm length 07-2120 UMA Transfer Copings UMA Hexed Transfer Coping Single tooth open tray UMA Guide Pin für 07-0090 07-0090 07-0062 UMA Non-Hexed Transfer Coping for bridge construction 07-0080

External hex BICORTICAL ENDOPORE UMA Analogs Brass 07-0015 Stainless Steel UMA retaining screw included 07-0162 Brass Stainless Steel UMA Copings UMA Temporary Non-Hexed Coping UMA retaining screw included 07-0352 UMA Hexed Plastic Coping UMA retaining screw included blue 07-0202 UMA Non-Hexed Plastic Coping UMA retaining screw included yellow 07-0252 UMA Non-Hexed Gold Coping UMA retaining screw included 07-0252/G UMA Temporary Non-Hexed Coping UMA Hexed Plastic Coping UMA Non-Hexed Plastic Coping UMA Non-Hexed Gold Coping 35 UMA Replacement Components UMA Non-Hexed Plastic Coping for Bar 07-0270 UMA Retaining Screw 07-0052 Gold Plated Bar Clip CM Rider 07-0120 UMA Hexed Plastic Coping UMA Retaining Srew Gold Plated Bar Clip UMA Bar Kit UMA Bar Kit Includes 4 bars, a spacer bar, 4 retaining screws, 4 plastic cylinders, and 4 gold plated clips 07-5540 UMA O-Ring System UMA O-Ring System Each abutment is packaged with an ORS lab kit that includes a brass abutment analog, metal housing, 3 red O-Rings and 3 white O-Rings. 07-4400 Note The red O-Ring is used for laboratory set-up and the white O-Ring is used for the finished overdenture.

ENDOPORE Prosthetics Prosthetic Instrumentation Hex Driver, 0.05 extra short, 9 mm short, 13 mm long, 18 mm 06-HDXS 06-HDS 06-HDL 36 9 mm 13 mm 18 mm extra short short long 30 Ncm Torque Wrench 20 Ncm Torque Wrench For use with UMA System and Locator System (Ncm Newton centimeters) 06-TW30 06-TW20 Driver Housing Driver Extension 07-0190 07-0195 Driver Housing Driver Extension Driver Tips fit Driver Housing and Torque Wrenches 0.05 Hex Tip 06-TWHT 0.05 Hex Tip Short 06-TWHTS UMA Driver ORS and Dalla Bona Driver 07-1150 07-0140 Hex Tip 12.5 mm Hex Tip short 6.5 mm UMA Driver ORS-, Dalla Bona Driver

Prosthetics BICORTICAL ENDOPORE Prosthetic Instrumentation Latch Driver 0.05 Hex Latch Type Driver 07-0125 UMA Friction Grip Driver Friction driver for UMA non-hexed transfer coping and UMA O-Ring 07-0004 Guide Pin for angled abutment selection 15 angled 25 angled 06-15AAGP 06-25AAGP 15 25 37 Reamer for use with UMA abutment castings for use with UCLA abutment castings 07-0150 06-REM Lapping Tool with guide pin for use with UMA and UCLA abutment castings and all platforms 07-0155WP Waxing Sleeve 06-WS

ENDOPORE Surgery Surgery 38 Comprehensive Surgical Kit Surgical Instrument Tray, fully equipped 06-ITSTART Content of a full equipped tray 2.3 mm Round Bur 06-RB 2.5 mm Twist Drill short 06-2.5TDS 2.5 mm Twist Drill long 06-2.5TDL 3.5 mm Implant Bur, 9 mm 06M-9IB 4.1 mm Implant Bur, 7 mm 06-7IB 4.1 mm Implant Bur, 9 mm 06-9IB 4.1 mm Implant Bur, 12 mm 06-12IB 5.0 mm Implant Bur, 5 mm 06W-5IB 5.0 mm Implant Bur, 7 mm 06W-7IB 5.0 mm Implant Bur, 9 mm 06W-9IB 5.0 mm Implant Bur, 12 mm 06W-12IB Drill Extension 06-DE 3.5 mm Trial Fit Gage, 9 mm 06M-9TFG/O 4.1 mm Trial Fit Gage, 7 mm 06-7TFG/O 4.1 mm Trial Fit Gage, 9 mm 06-9TFG/O 4.1 mm Trial Fit Gage, 12 mm 06-12TFG/O 5.0 mm Trial Fit Gage, 5 mm 06W-5TFG/O 5.0 mm Trial Fit Gage, 7 mm 06W-7TFG/O 5.0 mm Trial Fit Gage, 9 mm 06W-9TFG/O 5.0 mm Trial Fit Gage, 12 mm 06W-12TFG/O Paralleling Pins, Pack of 4 06-PP Mallet 06-M/L Punch Handle, straight 06-H Punch Handle, offset 06-HOS Stainless Steel Punch Tip 06-PTM Tip Wrench 06-TW Hex Driver 0.05 short 06-HDS Radiographic Overlays, 2 Pack 06-RO Surgical Video on DVD 06-SV Endopore Surgical Kits for use with all Endopore Implants with internal connection, internal hex and external hex. Endopore Osteotome Kit Endopore Osteotome Kit Osteotome Instrument Tray, fully equipped Content of a full equipped tray Osteotome Tip #1 Osteotome Tip #2 Osteotome Tip #3 Stainless Steel Punch Tip Punch Handle, straight, Pack of 4 Punch Handle, offset, one Mallet Osteotome Instrument Tray, empty 06-OTKIT 06-OT1 06-OT2 06-OT3 06-PTM 06-H 06-HOS 06-M/L 06-ITM/S2 Surgical Instrument Tray, empty 06-ITM/S1

Surgery BICORTICAL ENDOPORE Endopore Surgical Instrumentation Burs and Drills Crestotom for the removal of soft tissue, for smoothing and levelling of the alveor crest Initial Perforation (IP) Drill for initial perforation of the compact cortical bone, Ø 2.00 1452 90024 Round Bur Ø 2.3 mm Twist Drill short, Ø 2.5 mm, total length 30 mm 06-RB 06-2.5TDS 39 long, Ø 2.5 mm, total length 39 mm 06-2.5TDL Implant Burs Length Implant Burs for implant Ø 3.5 mm 9 mm 06M-9IB for implant Ø 4.1 mm 7 mm 06-7IB 9 mm 06-9IB 12 mm 06-12IB for implant Ø 5.0 mm 5 mm 06W-5IB 7 mm 06W-7IB 9 mm 06W-9IB 12 mm 06W-12IB

ENDOPORE Surgery Drill Extension Drill Extension 06-DE Trial Fit Gages/Osteotome Final Tips Length Trial Fit Gages/Osteotome Final Tips Implant Ø 3.5 mm 9 mm 06M-9TFG/O Implant Ø 4.1 mm 7 mm 06-7TFG/O 9 mm 06-9TFG/O 12 mm 06-12TFG/O 40 Implant Ø 5.0 mm The trial fit gages are threaded to connect to the punch handles. The trial fit gage corresponding to the size of the implant to be placed, acts as the final osteotome tip. 5 mm 06W-5TFG/O 7 mm 06W-7TFG/O 9 mm 06W-9TFG/O 12 mm 06W-12TFG/O Paralleling Pin Paralleling Pin for use with 2.5 mm twist drill 06-PP Mallet and Punch Handles Mallet 06-M/L Punch Handles for use in conjunction with osteotome tips and trial fit gages for osteotome technique straight offset 06-H 06-HOS straight offset

Surgery BICORTICAL ENDOPORE Punch Tips Stainless Steel Punch Tip for implant placement For use with all diameters. Connects to punch handle. 06-PTM Osteotome Punch Tips Osteotome punch tips connect to the punch handles. Osteotome Tip #1 Osteotome Tip #2 Osteotome Tip #3 06-OT1 06-OT2 06-OT3 Tip #1 Tip #2 Tip #3 Wrench and Driver Tip Wrench The tip wrench is used for tightening or loosening trial fit gages, punch tip and osteotome tips to the punch handles. 06-TW 41 Hex Driver 0.05 short length 13 mm 06-HDS 13 mm Cover Screw Trephines Cover Screw Trephines for implant Ø 3.5 mm for implant Ø 4.1 mm for implant Ø 5.0 mm Tissue Punch Tissue Punch The metal tissue punch attaches to the drill handpiece and will cleanly section a 4.3 mm diameter flap of tissue over the implant. 06M-3.5TR/CS 06-4.1TR/CS 06W-5.0TR/CS 06-TP

ENDOPORE Articles in alphabetic order Articles in alphabetic order Item Page Item Page 42 Angled s for - External Hex 30 - Internal Hex 16 Cementable s for Internal Connection 7 Cover Screw for - Internal connection 7 - Internal Hex 14 - External Hex 26 Cover Screw Trephines 41 Crestotom 39 Dalla Bona System for - Internal Connection 10 - Internal Hex 19 - External Hex 33 Drill Extension 40 Driver Extension 36 Driver Housing 8/10/36 Driver Tips 36 ECO System 7 Guide Pin 37 Healing s for - Internal Hex 14 - External Hex 26 Hex Driver 36/41 Hex Tip 0.05" 8/36 Hex Tip 0.05", short 36 Hex s for - Internal Hex 16 - External Hex 29/30 Implant Analogs for - Internal Hex 15 - External Hex 28 Implant Burs 39 Implants with - Internal Connection 4 - Internal Hex 11 - External Hex 22 Initial Perforation (IP) Drill 39 Insertion Tip 8 Latch Driver 37 Lapping Tool with guide pin 37 Locator s for - Internal Connection 9 - Internal Hex 18 - External Hex 32 Mallet 40 Octabutment System 8 O-Ring System (ORS) for - Internal Connection 10 - Internal Hex 19 - External Hex 32 Osteotome Instrument Tray, fully equipped 38 Paralleling Pin 40 Punch Handles 40 Punch Tips 41 Reamer 37 Retaining Screws 15/28 Round Bur 39 Surgical Instrument Tray, fully equipped 38 Temporary Titanium s 30 Tip Wrench 41 Tissue Punch 41 Torque Wrench 20 Ncm Ratchet 9/18/36 Torque Wrench 30 Ncm Ratchet 36 Transfer Copings for - Internal Hex 15 - External Hex 27 Trial Fit Gages/Osteotome Final Tips 40 Twist Drills 39 UCLA-s for - Internal Hex 17 - External Hex 31 UMA O-Ring System for External Hex 35 UMA System for - Internal Hex 20 - External Hex 34 UMA Driver 36 UMA Friction Grip Driver 37 Waxing Sleeve 37

ENDOPORE Implant Internal Connection Internal Hex Osteotome PROCEDURES perfect External Hex INTERNAL HEX PerfeCT SURFACE EXTERNAL HEX NTERNAL PERFECT SURFACE Implant Placement Procedure Innovative products PITT-EASY ENDOPORE BICORTICAL BIORESORB CYTOPLAST INNOVA ORALTRONICS ATTACHMENTS INTERNATIONAL A World of Implant Solutions The dental implant platform of Sybron Dental Specialties (SDS) brings together three organizations that have been leaders in implant manufacturing, design and development since the inception of implant dentistry. Delivering two of the most respected, leading-edge dental implants on the market ENDOPORE and PITT-EASY we are giving you access to a world of implant solutions. Manufacturer: Innova Corporation 522 University Ave Suite 1200 Toronto, ON M5G 1W7 Canada www.innovalife.com Distributed by: ORALTRONICS Dental Implant Technology GmbH Herrlichkeit 4 28199 Bremen Germany Phone +49 421 43939-0 Fax +49 421 443936 www.oraltronics.com info@oraltronics.com 07-0189: 06/07