IEC Subcommittee 62C (Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry): Recent and Active Projects

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Calibration of Radiation Instruments Used in Radiation Protection and Radiotherapy in Malaysia

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

Hong Kong Association of Medical Physics. Guide to Candidates

Albert Lisbona Medical Physics Department CLCC Nantes Atlantique a

Nuclear energy, nuclear technologies, and radiological protection Vocabulary. Part 4: Dosimetry for radiation processing

Development and prospects on dosimetry at radiotherapy levels in the Secondary Standard Dosimetry Laboratory of Cuba.

Current Status of Electronic Brachytherapy Dosimetry

New Radiation Health Technologies Challenges, Opportunities, Limitations

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

Twelfth Annual Warren K. Sinclair Keynote Address

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

The need for standardization of dosimetry in experimental radiation biology

A. DeWerd. Michael Kissick. Larry. Editors. The Phantoms of Medical. and Health Physics. Devices for Research and Development.

DOSIMETRIC COMPARISION FOR RADIATION QUALITY IN HIGH ENERGY PHOTON BEAMS

Implantable MOSFET dosimeter response to 192 Ir HDR radiation

Assessment of Dosimetric Functions of An Equinox 100 Telecobalt Machine

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology

QA for Clinical Dosimetry with Emphasis on Clinical Trials

Amendment No. 2. Item No. 2 (Rfx/ Event number )

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

Guideline & Reports 医学物理学会教育委員会資料

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

The Journey of Cyberknife Commissioning

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

IEC 87: Ultrasonics Overview update July 2002

Radiation physics and radiation protection. University of Szeged Department of Nuclear Medicine

PHYSICS NEEDS IN RADIATION SCIENCES. James Deye, Ph. D. Contractor, NCI Radiation Research Program

Sterilization of health care products Radiation. Part 3: Guidance on dosimetric aspects of development, validation and routine control

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

Hong Kong Association of Medical Physics

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

EORTC Member Facility Questionnaire

Who Should Know Radiation Oncology Coding?

Bureau of Laboratory Quality Standards

ISO INTERNATIONAL STANDARD

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

IPEM Recommendations for the Provision of a Physics Service to Radiotherapy

Beam Quality Effects in Nonstandard Fields of the Varian TrueBeam

RADIOTHERAPY DEPARTMENT

Computed tomography Acceptance testing and dose measurements

ADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro

Specific Aspects of Radiochromic Film Dosimetry AAPM Task Group 235 An Update to Task Group 55 (1998)

Plan-Specific Correction Factors for Small- Volume Ion Chamber Dosimetry in Modulated Treatments on a Varian Trilogy

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

THE IAEA/WHO NETWORK OF SECONDARY STANDARD DOSIMETRY LABORATORIES SSDL NETWORK CHARTER

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Presented by: Rebecca M. Howell PhD, DABR, FAAPM. Results from Voluntary Independent External Peer Review of Beam Output

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

TECHNICAL REPORT. Medical electrical equipment Guidelines for implementation of DICOM in radiotherapy

CT Quality Control Manual FAQs

Application of the Commission's Recommendations for the Protection of People in

Bell in 1903 was first suggested implanting. First Report on Study of Quality Control Program of High Dose Rate (Hdr) Brachytherapy.

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Procedure. Identify all possible radiation hazards.

ICRP 128 ICRP ICRP ICRP 1928

Eric E. Klein, Ph.D. Chair of TG-142

Limits of Precision and Accuracy of Radiation Delivery Systems

Manik Aima, Larry A. DeWerd, Wesley S. Culberson

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

PGY-1. Resident Review Session Schedule

Investigation of the clinical performance of a novel solid-state diagnostic dosimeter

Quality assurance in external radiotherapy

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

Dosisverifikation mit Delta 4 Discover während der Behandlung

Canadian Partnership for Quality Radiotherapy. Technical Quality Control Guidelines for Gamma Knife Radiosurgery. A guidance document on behalf of:

Lessons learned from accidents in conventional external radiotherapy

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

AAPM Administrative Policy: Joint AAPM/IROC Houston Registry of Brachytherapy Sources Complying with AAPM Dosimetric Prerequisites

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

The RPC s Evaluation of Advanced Technologies. AAPM Refresher Course July 29, 2008 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Verification of Advanced Radiotherapy Techniques

5th ADAMAS Workshop at GSI December 15-16, 2016, Darmstadt, Germany

I. Equipments for external beam radiotherapy

TLD as a tool for remote verification of output for radiotherapy beams: 25 years of experience

Has radiotherapy the potential being focal?

Mammography calibration qualities establishment in a Mo- Mo clinical system

PERSONNEL MONITORING AND DOSIMETRY POLICIES

The IAEA BSS and development of an international dosimetry protocol

FEE RULES RADIATION ONCOLOGY FEE SCHEDULE CONTENTS

Facing the challenges: IAEA activities to protect the patients

Catharine Clark NPL, Royal Surrey County Hospital and RTTQA

LONG TERM STABILITY OF THE PERFORMANCE OF A CLINICAL LINEAR ACCELERATOR AND Z-SCORE ASSESSEMENT FOR ABSORBED DOSE TO WATER QUANTITY

ADVANCED TECHNOLOGY CONSORTIUM (ATC) CREDENTIALING PROCEDURES FOR LUNG BRACHYTHERAPY IMPLANT PROTOCOLS

DOSE MEASUREMENTS IN TELETHERAPY USING THERMOLUMINESCENT DOSIMETERS

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

ph fax

8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit

Appendix I. List of stakeholders consulted with on the Patient Radiation Protection Manual and members of the Medical Exposure Radiation Unit

Influence of the exposure time in the area monitors at radiodiagnostic

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Transcription:

IEC Subcommittee 62C (Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry): Recent and Active Projects 2015 AAPM Annual Meeting Anaheim, CA Wes Culberson, PhD, DABR University of Wisconsin Madison University of Wisconsin Medical Radiation Research Center (UWMRRC)

Topics Covered 1. Getting involved in the IEC 2. Scope of IEC 62C 3. Structure of 62C 4. List of current projects for the working groups of 62C 2 of 34

Getting Involved Each person has a story of how they became involved in the IEC For seven years I worked as a clinical medical physicist I (like others) assumed that the manufacturers and ADCLs were providing accurate calibrations on equipment that worked Then after working in an accredited dosimetry calibration laboratory (ADCL), I recognized the impact of technical standards 3 of 34

Clinical Physicists Front line clinical physicists care about their equipment and that it functions properly Without standards, equipment may not operate properly in conditions outside of ADCL calibration environments Clinical physicists do not have the time or resources to test every piece of equipment for all technical aspects! Observations: Many more standards should be proposed System is difficult to navigates acronyms!!! Very formal, but opinions welcomed Slow to create standards, but well thought through 4 of 34

Participation Countries are members of IEC SC 62C / People are members of the working groups (as experts) Each member nation participates in the IEC through its national committee The U.S. National Committee (USNC) is located at the offices of American National Standards Institute (ANSI) in New York. The USNC established a technical advisory group (TAG) associated with subcommittee 62C, whose role is to advise the USNC This setup helps assure that the standards are scientifically and clinically meaningful 5 of 34

Rationale and history of IEC 62C Technical Committee No 62: Electrical Equipment in Medical Practice Subcommittee 62C is responsible for equipment for Radiation therapy Nuclear medicine Radiation dosimetry SC 62C is the smallest of the SC in 62 (in membership) Small but mighty Many active projects 6 of 34

Scope of 62C The preparation of standards for the safety and performance of medical equipment and systems using ionizing radiation for the treatment of disease associated equipment and software used in planning, delivering and monitoring such treatments instruments measuring ionising radiation used in the diagnosis and treatment of disease radiation conditions for testing them nuclear medicine equipment Proposed scope change and nuclear medicine equipment used for imaging the distribution of radioactive substances within the human body for both diagnostic purposes and radionuclide therapies. 7 of 34

Structure of 62C IEC (Geneva, Switzerland) TC61 TC62 Electrical Equipment in Medicine TC64 SC62A Common Aspects SC62B Diagnostic Equipment SC62C Equipment for RT, NM, Dosimetry SC62D Non Radiological WG1 Equipment for RT WG2 Equipment for NM WG3 Equipment for Dosimetry 8 of 34

SC62C Officers Chairman: Geoff Ibbott (USA) Secretary: Norbert Bischof (Germany) Technical Officer: Laurent Mailly 9 of 34

Liasons Digital Imaging and Communications in Medicine (DICOM) International Atomic Energy Agency (IAEA) International Commission on Radiological Protection (ICRP) Collaborations ASTRO AAPM ACR 10 of 34

Meetings Annually Last meeting was held in New Orleans in Nov, 2014 Next meeting in Kobe, Japan in Nov, 2015 11 of 34

Within SC 62C Working Groups Meet periodically Actively work on new and existing standards Comprised of a convenor and experts Project Teams Single specific theme Comprised of a project team leader and experts 12 of 34

3 Working Groups WG1 Radiation therapy equipment WG2 Nuclear medicine equipment WG3 Radiation dosimetry measurement equipment 13 of 34

Project Teams Project Team (PT) 62926 within WG1: Medical electrical equipment Requirements of safety and performance of complex real-time controlled radiotherapy systems for a moving target Individual Approach Systems Approach 14 of 34

Project Team Discussions Information communicated to other working groups via documents online Example: 62C/618/DC is a document for comments within SC62C All participating countries can give feedback P-members vote and comment on documents 10 15 of 34

Current AAPM Involvement WG1 (Radiation Therapy) Geoff Ibbott, PhD (chair of SC62C, Technical Advisor to USNC, Convenor of WG-1, Chair of TAG dealing with 62C standards) Michael Moyers, PhD Raymond Wu, PhD Frank Bova, PhD Alan Cohen, MS (Accuray) Anuj Purwar, PhD (Varian) WG2 (Nuclear Medicine) James Halama, PhD WG3 (Radiation Dosimetry) Wes Culberson, PhD Larry DeWerd, PhD Douglas Pfeiffer, PhD Tom Heaton FDA Michele Obrien - NIST Paul Sunde - RadCal Bill Zimmerman Fluke Ray Riddle - SI William Maloney - FDA 16 of 34

WG1 List of Projects (Green items indicates active) IEC 60601-2-1 Basic safety Electron accelerators in the range 1 MeV to 50 MeV Preparing new 4 th edition IEC 60601-2-8 Basic safety and essential performance of therapeutic x-ray equipment operating in the range 10 kv to 1 MV Working on Amendment 1 IEC 62667 Light ion beam medical equipment Performance characteristics 17 of 34

WG1 Safety Standards IEC 60601-2-64 Light ion beam equipment IEC 60601-2-68 X-ray based IGRT equipment for use with electron accelerators, light ion beam therapy systems and radionuclide beam therapy systems IEC 60601-2-29: 2008 radiotherapy simulators 18 of 34

WG1 Safety Standards IEC 60601-2-17: 2013 Applies to performance of remote HDR afterloaders Applies to sealed sources and electronic brachytherapy (ebt) Requirements for manufacturers Places limits on the degradation of equipment Interlocks Assumes that the TPS and source strength are known 19 of 34

WG1 Project IEC 60601-2-1 Is the third edition of IEC 60601-2-1, known as the Accelerator Safety Standard. Edition 4 is bringing accelerator technology up to today s standards Probably the most comprehensive, farreaching and influential recent work of WG-1 Dictates the design of important safety features of medical linear accelerators including requirements for a dual-channel dosimetry system, testing of interlocks, permitted levels of radiation leakage and certain important characteristics of the radiation beams. 20 of 34

WG1 IEC 60601-2-64 Published last year and is stable now For proton and light ion accelerators. US Spearheaded Addresses aspects of beam control considered important for safety such as selection and verification of the correct beam energy (or range), range modulation lateral beam spreading and uniformity correct dose delivery. It also specifies safety provisions such as collision avoidance, correct treatment couch positioning and avoidance of electrical hazards. 21 of 34

WG1 IEC 60601-2-68 Addresses the use of equipment for x-ray image guidance of radiation therapy Published last year and is stable Provisions specify limits on the control of movements of the equipment and allowable speeds controls on the delivery of radiation Resolution on monitors is addressed Types of images that can be used as reference images (orientation, DICOM conformance statement as an example) IGRT dose quantities other safety aspects. 22 of 34

WG2 (Nuc Med) Recent meeting held April 27-29, 2015 in Vancouver, Canada Maintenance Projects have been initiated for the following Technical Reports: IEC 61303: 1994 IEC TR 61948-1: 2001 IEC TR 61948-2: 2001 IEC TR 61948-3: 2005 IEC TR 61948-4: 2006 New item work proposal (NP) on cardiac cameras The US National Committee has agreed to submit a proposal 23 of 34

WG2 Current Project IEC TR 61948-1 Nuclear medicine instrumentation Routine tests Part 1: Radiation counting systems, copyright 2001 IEC 61675-2 This technical report describes test methods of counting instruments for measuring RADIONUCLIDES in vivo and in vitro without the option of imaging. Gamma cameras for planar, wholebody, and SPECT imaging, Part 2 Combines two standards: 61675-1-1 and 60789 (Anger type gamma cameras) Copyright 2015 24 of 34

WG3 (Radiation Dosimetry) Convenor Ludwig Buermman (PTB Germany) New secretariat is Norbert Bischof from Germany Recent meeting held June 25-26, 2015 in Stockholm, Sweden 25 of 34

WG3 List of Standards IEC 60580 Dose area product meters (2 nd edition 2000-01) IEC 60731 Dosimeters with ionization chambers as used in radiotherapy IEC 61267 Radiation conditions for use in the determination of characteristics Lots of x-ray beam qualities standardized IEC 62467-1 No therapeutic beam qualities addressed Dosimetric instruments as used in brachytherapy Part 1: instruments based on well-type ionization chambers IEC 61676 Dosimetric instruments used for non-invasive measurements of x-ray tube voltage in diagnostic radiology 26 of 34

IEC 60731 Chambers + Electrometers Dosimeters with ionization chambers as used in radiotherapy Includes requirements for ionization chamber performance Assembly Humidity Temperature Pressure changes Sealed chamber designs Survey sent out to countries in 2014 Survey results showed interest in including other types of dosimeters such as semiconductors At WG3 meeting in Sweden it was decided to investigate further. Likely result is to break into two standards: chambers and diodes 27 of 34

60731 Details Defines reference-class vs field-class dosimeters Reference-class Chamber assembly Long-term stability Post-irradiation leakage Measuring assembly Long-term stability Resolution Repeatability Zero drift No sealed chambers 28 of 34

WG3 60731 Update Correcting for zero drift During a step and shoot IMRT, beams will have intermittent times of zero output. Zero drift can be tested by looking at known charges injected and pausing for different amounts of time. Zero Drift Dm = (Q2-Q1)/T 29 of 34

Which of the following detectors is not covered under the IEC 60731 standard? 8% 1. Spherical ion chambers 45% 1% 39% 7% 2. Diode detectors 3. Thimble ion chambers 4. Sealed ion chambers 5. Parallel-plate chambers

SAM Q1 Answer Answer: 2 Diode detectors Ref: IEC 60731 Medical electrical equipment dosimeters with ionization chambers as used in radiotherapy, IEC, Geneva, Switzerland, 2011. 32 of 34

Which of the following is not a requirement of a reference class dosimeter according to the IEC 60731 standard? 3% 1. Long-term stability 0% 19% 10% 68% 2. Repeatability 3. Zero drift 4. Resolution 5. Waterproof

SAM Q2 Answer Answer: 5 Waterproof Ref: IEC 60731 Medical electrical equipment dosimeters with ionization chambers as used in radiotherapy, IEC, Geneva, Switzerland, 2011. 35 of 34

Conclusions AAPM members are involved in the working groups of IEC SC62C SC62C created to maintain safe standards for manufacturers of radiotherapy equipment and nuclear medicine equipment Several projects are actively being revised More input from AAPM members is better Questions? 36 of 34

37 of 34