Satisfy central line placement guidelines with two convenient bedside trays.

Similar documents
Optimize your hemodialysis procedural bundle.

Make the right vascular access choice, with Cook s comprehensive line of PICCs.

Spectrum In-Service Guide. In-Service Guide

More control, less stress.

Move beyond to Biodesign.

Make the right vascular access choice, with Cook s comprehensive line of PICCs.

Make the right vascular access choice, with Cook s comprehensive line of PICCs.

Why and how to prep the vessel

Thora-Para catheter drainage systems

SAFETY-DELUXE DIAGNOSTIC AND PROCEDURAL TRAYS

PATIENT GUIDE. Treating Your Thoracoabdominal Aortic Aneurysm. Zenith t-branch THORACOABDOMINAL ENDOVASCULAR GRAFT

Evolution C ONTROLLED-RELEASE STENT

A CATHETER FAMILY FOR ALL YOUR PATIENT NEEDS

Simplifying hemostasis.

Rely on image-guided enteral feeding and cecostomy options from a name you trust.

Accessories. for Endovascular Procedures

DRAINAGE. Merit.com. Corporate Headquarters, South Jordan, Utah USA. Austria Norway

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

Advance to the next generation of percutaneous tracheostomy introducers.

drainage prepare access drain secure contain integrate

SEE WHY ZILVER PTX IS A GAME CHANGER.

ACCEL VALVED SAFETY CENTESIS CATHETER WITH INTROCAN SAFETY TECHNOLOGY

Continuous peripheral nerve block catheter

E S C C R I A L T E A R. One great catheter + maximum barrier insertion. c k. p a. h e. a t. a l. r i t e. A r

interventional cardiology

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

Sterile Technique & IJ/Femoral Return Demonstration

Safe-T-Centesis catheter drainage system. Innovations in patient safety, clinician safety and procedural efficacy.

Ultrasound Guided Drainage Procedures

Arrow Right Heart Catheters and Vascular Access Sheaths Diagnostic Monitoring and Therapeutic Catheter Solutions

Lifecath Twin & Dualyse/Trilyse Permanent and Temporary Renal Catheters

The Power of Purple* Polyurethane PICC. Patient Guide. Access Systems

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017

arrow nextstep antegrade & Arrow Edge The next step in dialysis catheter technology

PRODUCTS FOR EMERGENCY MEDICINE AND TRAUMA MEDICAL

Better Post-Op Pain Control Starts Here

2. Need for serial arterial blood gas determinations. 2. Anticipation of the initiation of thrombolytic therapy

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE REF LOT STERILE EO. Manufactured for: 824 Twelfth Avenue Bethlehem, PA

Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy.

Product Catalog 2016 EMEA

DRAINAGE. MeritEMEA.com

Department Policy. Code: D:PC Entity: Fairview Pharmacy Services. Department: Fairview Home Infusion. Manual: Policy and Procedure Manual

ATI Skills Modules Checklist for Central Venous Access Devices

Arrow Cannon II Plus Retrograde-tunneled, Tip-first Chronic Hemodialysis Catheter

Peripherally Inserted Central Catheter & Midline Placement with ECG Confirmation of Tip Placement

* CDC (Central Disease Control, USA) Guideline 2011* recommends using transparent and split septum designed needle free valves.

INNOVATIVE PRODUCTS G, J AND GJ-TUBES WITH ENFit TM CONNECTION

Anaesthetic Procedure Packs Ensuring maximum barrier precautions

Central Line Care and Management

PRODUCTS FOR THE DIFFICULT AIRWAY. Courtesy of Cook Critical Care

MAKE THE CLEAR CHOICE. IV Products and Accessories Designed to Help Maximize Clinical Performance While Optimizing Savings

Retractable Technologies, Inc.

LINEAR. 7.5Fr. IAB Catheter. This document is intended to provide information to an international audience outside of the US.

LINEAR 7.5Fr. IAB Catheter

Central Venous Catheter Insertion: Assisting

The next step in dialysis catheter technology

Veterinary Products Catalog. I.V. Catheters Needles Syringes Winged Infusion Sets

AMSure UROLOGICAL CARE

Peritoneal Dialysis. Life Improved

PICC and Midline Catheters

Doctor choice, patient comfort.

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

Imbibe Bone marrow aspiration needle. Operative technique

Per-Q-Cath* PICC Catheters with Excalibur Introducer* System

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE. Rx only REF LOT. STERILE EO Sterilized using ethylene oxide

Xcela Hybrid PICC with PASV Valve Technology

THE BUSSE PAIN MANAGEMENT TRAY PROGRAM. To Building The Exact Tray For

Port Design. Page 1. Port Placement, Removal, and Management. Selecting a Vascular Access Device. Thomas M. Vesely, MD

BD PosiFlush Pre-Filled Syringes * Average reflux as measured in 4Fr PICC; data on file at BD.

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

Sharps Safety. Product Catalog. Needle-Pro EDGE Safety Needles and Syringe Combinations. Arterial Blood Sampling Kits

Extended Dwell Catheter Product Offerings. Providing optimal outcomes for long-term and intermediate therapies

Polyurethane Radiology PICC

Successful IV Starts Revised February 2014

The University of Toledo Medical Center and its Medical Staff

Cook Europe Shared Service Centre

BARD. Instructions For Use

P: (888) F: (888)

Chemical compatibility of the Pall QPoint TM Docking Station - Tap Assembly with common surface disinfectants

ASEPT Pleural Drainage System

A FEW WORDS ABOUT US

The first convertible endotracheal tube

Because your patients trust you to be your best

The High-Flow Port Designed & Indicated for Apheresis

Helping to protect you from exposure to hazardous drugs

HLS Cannulae Solutions from tip to tip.

HLS Cannulae Solutions from tip to tip.

Initial placement 24FR Pull PEG kit REORDER NO:

Endo Fascial Closure System

Aspira* Peritoneal Drainage Catheter

Vascu-PICC WITH CUFF PERIPHERALLY INSERTED CENTRAL VEIN ACCESS CATHETER INSTRUCTIONS FOR USE

FLEXIC ATH LTD. Peripherally Inserted. Instructions n For Use.

Spinal Anaesthesia. Spinal Anaesthesia PAIN MANAGEMENT

MANITOBA RENAL PROGRAM

Prevention of Central Line-associated Bloodstream Infections (CLA-BSIs) associated with Arterial Catheters

Groshong Catheters with Introcan Safety Peripheral IV Catheter Introducer

Arrow-Clark VectorFlow Hemodialysis Catheter Because in Chronic Hemodialysis Catheters, the Tip Matters

Infusion Skills Competency Checklist To be used at annual skills fair or at any other time for IV Competency

Fundamentals of Flushing and Locking

arrow Diagnostic and drainage products More options for easier, less traumatic procedures

Transcription:

Satisfy central line placement guidelines with two convenient bedside trays. COOK CATHETER TRAY MEDICAL www.cookmedical.com

Two solutions for seven organizations. The Cook Catheter Tray and the Cook Catheter Tray with Maximal Sterile Barriers are two options designed to help meet these organizations guidelines: Agency for Healthcare Research and Quality (AHRQ) Institute for Healthcare Improvement (IHI) Society for Healthcare Epidemiology of America (SHEA) Infectious Diseases Society of America (IDSA) Centers for Disease Control and Prevention (CDC) The Joint Commission Occupational Safety & Health Administration (OSHA) The Comprehensive Unit-Based Safety Program (CUSP) These organizations recommend maximal sterile barrier precautions or needlestick prevention to minimize injuries and reduce infections in both patients and clinicians. In addition to increasing the safety for patients and clinicians, Cook Catheter Trays are designed to optimize procedure outcomes and respond to the demands of hospital value-analyzed purchasing in response to clinical and administrative feedback. Catheter features such as power-injection may decrease the number of unnecessary vascular access procedures that can result in increased costs and inefficiencies within a hospital facility. Organized for safety from start to finish. The Cook Catheter Tray provides a complete and convenient assortment of all the components you need to place a central venous catheter (CVC) at the bedside. The tray is ergonomically designed and sequentially organized to promote procedural efficiency and accuracy and to eliminate hassle. The Cook Catheter Tray is available with maximal sterile barrier components to further your facility s goal of reaching an infection rate of zero.

The following components meet your safety-precaution needs: Preparation The tray includes components that ensure safety, even before the procedure starts. Catheter Insertion Checklist ChloraPrep with Hi-Lite Orange Tint Lidocaine and lidocaine label Filter straw Prefilled sodium chloride syringes The maximal sterile barrier option includes a cap, mask with face shield, gown, gloves, and a large drape Placement The tray components are ergonomically placed and sequentially ordered to aid the clinician at each step of the procedure. Power-injectable* central venous catheter with Luer-lock end caps BakSnap safety syringe EchoTip echogenic introducer needles MicroCLAVE Neutral Displacement Connector Safe-T-J double flexible-tipped wire guide with centimeter markings Sterile gauze pads Safety scalpel Suture with a needle driver Postprocedure Safety precautions don t end when the CVC is placed: It is vital to complete and file the procedure checklist in order to manage safety and comply with your facility s safety process. Safety components for sharps help prevent injury from accidental needlesticks. Prefilled sodium chloride syringes Locking sharps container Needle holder cup MicroCLAVE Neutral Displacement Connector StatLock securement device** Catheter Insertion Checklist (same list for preparation) Postprocedure label for the patient chart BakSnap is a registered trademark of DuoProSS Meditech Corporation. ChloraPrep is a registered trademark of CareFusion 2200, Inc. MicroCLAVE is a registered trademark of ICU Medical, Inc. StatLock is a registered trademark of C.R. Bard, Inc. *Power-injectable central venous catheters are available only in 7.0, 8.0, 9.0, and 10.0 Fr. **The StatLock securement device is available with 4.0 and 5.0 Fr central venous catheters.

COOK CATHETER TRAY WITH MAXIMAL STERILE BARRIERS Simplify your compliance process. Catheter insertion checklist The checklist provides step-by-step directions for CVC placement. The checklist helps you comply with CDC, IHI, and NHSN guidelines. BakSnap safety syringes The retractable and locking plunger enhances needlestick safety and reduces the risk of contamination. Use of the BakSnap complies with OSHA s Needlestick Safety and Prevention Act. Disposable safety scalpel EchoTip echogenic needle(s) Prefilled 10 ml sodium chloride syringes Locking sharps container The sharps container reduces the risk of accidental needlesticks during disposal. Use of the sharps container complies with OSHA s Needlestick Safety and Prevention Act. Lidocaine with an adhesive syringe label The label complies with The Joint Commission guidelines. Filter straw The filter straw reduces the risk that particulates will enter the syringe.

Maximal sterile barrier preparation bundle The following components comply with CDC, IHI, and SHEA/IDSA guidelines: Sterile gown Mask with a face shield Cap Large, fenestrated drape with clear window ChloraPrep One-Step applicators with orange tint These components comply with CDC and IHI guidelines. Multi-lumen central venous catheter with Luer-lock end caps Power-injectable central venous catheters are available in 7.0, 8.0, 9.0, and 10.0 Fr. MicroCLAVE Neutral Displacement Connectors Safe-T-J double flexible-tipped wire guide with centimeter depth markings Straight or curved needle with suture and needle driver The following components are also included: 22 gage needle 25 gage needle FEP catheter introducer needle Transducer tubing Dilator(s) Sterile gauze sponges Needle holder cup CSR wrap Movable suture wing StatLock securement device (Available in 4.0 Fr and 5.0 Fr only) 6 ml disposable syringe

STANDARD COOK CATHETER TRAY The standard Cook Catheter Tray includes the following components: Multi-lumen central venous catheter (The power-injectable central venous catheter with Luer-lock end caps is available in 7.0, 8.0, 9.0, and 10.0 Fr.) Safe-T-J double flexible-tipped wire guide with centimeter depth markings EchoTip echogenic introducer needle(s) BakSnap safety syringe Prefilled 10 ml sodium chloride syringes 22 gage needle 25 gage needle FEP catheter introducer needle Transducer tubing Dilator(s) Lidocaine with adhesive syringe label Filter straw Orange-tinted ChloraPrep One-Step A large, fenestrated drape with a clear window Sterile gauze sponges Disposable safety scalpel Straight or curved needle with suture and a needle driver 6 ml disposable syringe MicroCLAVE Neutral Displacement Connectors Locking sharps container Needle holder cup CSR wrap Movable suture wing StatLock securement device Catheter insertion checklist

Range of Sizes and Configurations Cook offers a range of CVC sizes, from 4.0 Fr to 10.0 Fr, to serve a variety of patient populations. Power-injectable uncoated catheters are available in 7.0, 8.0, 9.0, and 10.0 Fr only. Using power injectable catheters can reduce the number of needlesticks and eliminate the need to place additional catheters, which may reduce the chance of infection and lead to lower costs. Catheter Fr 4.0 Double (UDLM) 5.0 Double (UDLM) 5.0 Triple (UTLM) 7.0 Triple Power-Injectable (UTLM) 8.0 Double Power-Injectable (UDLM) 9.0 Triple Power-Injectable (UTLM) 10.0 Five Lumen Power-Injectable (UQLM) Cross-section Lumen No./ Hub Color Port Equivalent gage Minimum Lumen Volume ml Approximate Flow Rate ml/hr Maximum Flow Rate ml/sec* Average Pressure at Maximum Flow psi* 1 Distal 20 0.2 780 - - 2 Proximal 23 0.2 180 - - 1 Distal 20 0.2 900 - - 2 Proximal 20 0.2 1,200 - - 1 Distal 18 0.3 1,200 - - 2 Mid 23 0.2 120 - - 3 Proximal 23 0.2 120 - - 1 Distal 16 0.6 3,840 10 143.3 2 Mid 18 0.5 1,560 10 143.3 3 Proximal 18 0.6 1,860 10 143.3 1 Distal 14 0.9 6,780 10 55.1 2 Proximal 14 1.0 7,260 10 55.1 1 Distal 14 0.9 10,140 10 35.8 2 Mid 18 0.4 1,380 10 35.8 3 Proximal 18 0.5 1,440 10 35.8 1 Distal 14 0.9 8,820 10 32 2 Mid 17 0.4 2,880 10 32 3 Mid 17 0.4 2,940 10 32 4 Proximal 19 0.2 840 10 32 5 Proximal 19 0.2 840 10 32 *Maximum pressure limit settings of 325 psi. All testing verified on industry-leading MEDRAD Stellant CT Injector.

MEDICAL Customer Service EMEA: EDI www.cookmedical.com/edi.do Distributors: +353 61239240, ssc.distributors@cookmedical.com Austria: +43 179567121, oe.orders@cookmedical.com Belgium: +32 27001633, be.orders@cookmedical.com Denmark: +45 38487607, da.orders@cookmedical.com Finland: +358 972519996, fi.orders@cookmedical.com France: +33 171230269, fr.orders@cookmedical.com Germany: +49 6950072804, de.orders@cookmedical.com Hungary: +36 17779199, hu.orders@cookmedical.com Ireland: +353 61239252, ie.orders@cookmedical.com Italy: +39 0269682853, it.orders@cookmedical.com Netherlands: +31 202013367, nl.orders@cookmedical.com Norway: +47 23162968, no.orders@cookmedical.com Spain: +34 912702691, es.orders@cookmedical.com Sweden: +46 858769468, se.orders@cookmedical.com Switzerland French: +41 448009609, fr.orders@cookmedical.com Switzerland Italian: +41 448009609, it.orders@cookmedical.com Switzerland German: +41 448009609, de.orders@cookmedical.com United Kingdom: +44 2073654183, uk.orders@cookmedical.com www.cookmedical.com Americas: EDI www.cookmedical.com/edi.do Phone: +1 812.339.2235, 800.457.4500, Fax: 800.554.8335 E-mail: orders@cookmedical.com Australia: Phone: +61 734346000, 1800777222, Fax: +61 734346001, 1800077283 E-mail: cau.custserv@cookmedical.com COOK 2013 CC-BM-CVCMP-EN-201311