GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

Similar documents
GRASON-STADLER HEARING ASSESSMENT SYSTEMS

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Handheld OAE-Tympanometry Combination System

Science made smarter. Titan. Advanced made flexible. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

GSI AMTAS AUTOMATED AUDIOMETRY. Setting The Clinical Standard

Oscilla - excellence since 1960

Audiology Equipment p r o d u c t s c AtA l o g u E

GSI 61 CLINICAL TWO-CHANNEL AUDIOMETER

AT235 Middle Ear Analyzer. Diagnostic & clinical tympanometry with basic audiometry

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

Bio-logic AuDX PRO FLEX Quick start Quick start guide

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )

MI 44 Operating Instructions

AA222 / AA220. Audio Traveller. Save time on routine. Focus on results. Interacoustics. leading diagnostic solutions

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

Diagnostic Impedance & Audiometry in one solution

QUICK START GUIDE SENTIERO DESKTOP DIAGNOSTIC (WHITE HOUSING)

QUICK START GUIDE TYMPANOMETRY AND AUDIOMETRY FOR SENTIERO DESKTOP DEVICES

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

myaudiometer. It s familiar, and it s so much

by Maico Diagnostics

A full product range for your every need. World leading diagnostic solutions

MEASUREMENTS AND EQUIPMENT FOR AUDIOLOGICAL EVALUATIONS

Amplivox Ltd Otowave 302 Tympanometer Operating Manual

Experience the power of integration

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

Instructions for Use. Oscilla TSM400 Screening Tympanometer. Specifications are subject to change without notice ID: 6795 / ver.

Operating Instructions MI 24

AD226 Diagnostic Audiometer

AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY

AC40. The true clinical. hybrid

QUICK START GUIDE SENTIERO DESKTOP OAE AND TYMP SCREENER (BLUE HOUSING)

MI 26 Operating Instructions

The true clinical hybrid audiometer. Interacoustics. Clinical Audiometer AC40. Stand alone & PC-based audiometry in one box.

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

Additional Information Titan

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

AC40 Technical Specificatons Page 1. Technical Specifications AC40. Clinical Audiometer

Technical Report: Distortion Product Otoacoustic Emissions That Are Not Outer Hair Cell Emissions DOI: /jaaa

ERO SCAN. Otoacoustic Emission Testing

Operating Instructions MI 24, MI 24h

The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box. Interacoustics. Clinical Audiometer AC40.

Neuro-Audio Version 2010

EA 87. Clinical Impedance. Audiometer. User Manual

AC40 Technical Specificatons. Technical Specifications AC40. Clinical Audiometer D F 2017/11

Operating Instructions MAICO MI 26

Operating Instructions Race Car Tympanometer w/ Audiometer

ABOUT THIS MANUAL READ THIS OPERATING MANUAL BEFORE ATTEMPTING TO USE THE INSTRUMENT.

Equinox 2.0. PC-based audiometer. Time saving solutions. Interacoustics. leading diagnostic solutions

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

The Eclipse High quality evoked potentials at your command. AEP, ASSR, & OAE testing on one dedicated platform

Welch Allyn TM286 Auto Tymp

This document presents the reader with instructions on using AudBase in the UCSF environment. AudBase Guidebook. Application How-To.

Operation Manual easytymp TM

Otowave 202. Operating Manual

Table of Contents Morning Set-up (GSI equipment, only)... 2 Opening AudBase... 3 Choosing a patient... 3 Performing Pure-Tone Air & Bone

AMBCO AUDIOMETER

General Catalogue. Product Line for Hearing Screening & Diagnostics

General Catalogue. Hearing Screening & Diagnostics

OtoRead Portable OAE. More Time for Care. Optimized for Accuracy and Ease of use

BioMed Jena GmbH -Biomedical Technology- PRODUCT CATALOGUE AUDIOLOGY

General Catalogue. Product Line for Hearing Screening & Diagnostics

AD629 The true hybrid

Diagnostic Audiometer

BioMed Jena GmbH -Biomedical Technology- PRODUCT CATALOGUE AUDIOLOGY

MADSEN Zodiac Diagnostic & Clinical Stand-alone

ER75 Electro-Acoustic Ear Simulator. Operating Manual

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

General Catalogue. Product Line for Hearing Screening & Diagnostics

ATMOS 360 diagnostics. Complete solution.

General Catalogue. Hearing Screening & Diagnostics

Reliable, flexible & precise

TYMP Technical data. at 85, 95 und 105 db HL. 2. detailed display symbols

Comparison of Acoustic Immittance Measures Obtained With Different Commercial Instruments

AA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer

SECTION 6: DIAGNOSTIC CLASSIFICATION TERMS AND NORMATIVE DATA

Documentation, Codebook, and Frequencies

Unlock. your potential. Otometrics Madsen A450 the audiometer that works for you N O A H P M M R E P O R T I N G H I T C O U N S E L I N G

MADSEN OTOflex 100 & OTOsuite Immittance Module

MADSEN Zodiac Quick Check PC-based

QUICK START GUIDE SENTIERO HANDHELD OAE AND AUDIOMETRY SCREENER (GREEN LABEL)

BC380. The New Standard in Body Composition Analysis BODY COMPOSITION ANALYZER

III. Comprehensive. Efficient. Auditory EP Testing

AudioConsole. User Guide. Doc. No EN/01 Part No EN

Hearing Solutions Catalog Winter Supplement January 2009

The registration testing for audiometric device in CFDA

MedRx Otowave 102 Hand Held Portable Tympanometer Operating Manual (Applies from serial number onwards)

The true hybrid Stand alone & PC-based audiometry in one box

Tympanometry and Reflectance in the Hearing Clinic. Presenters: Dr. Robert Withnell Dr. Sheena Tatem

AMBCO 1000+P AUDIOMETER

Transcription:

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER New Standard for Clinical Impedance The GSI TympStar Pro is setting the clinical standard for performing a full range of middle-ear measurements on patients of all ages. Audiologists will feel an instant comfort with the TympStar Pro's consistent interface. GSI understands that efficiency is required in today s busy audiology practice and strives to provide hearing healthcare professionals versatility, efficiency and reliability in a comprehensive middle-ear analyzer. TYMP TOUCH TECHNOLOGY Tymp Touch Technology A simple touch of the screen provides access to user protocols, test parameters and on-screen analyses of test results. Evaluation of the immittance properties of the middle-ear and assessment of neural integrity are completed seamlessly. This touch screen interface will revolutionize how clinicians interact with their tympanometer. Improve Workflow Capabilities Customizable user tests and pre-defined protocols Auto Start for screening and diagnostic tympanometry Automatic detection of acoustic reflex thresholds Display multiple immittance components Start tests from probe box Easy to view and operate touch screen

Features Integrated 12 inch color touch screen Auto Start with seal for screening and diagnostic tympanograms Multiple probe tone frequencies included Pressure sweep speeds 12.5, 50, 200, 600/200 dapa/second Manual pump control Multiple Immittance Displays (Y/B/G) Zoom function for detailed analysis of results Customizable tympanogram labels or Jerger classification Start tests or switch ears from probe box Automatic detection of acoustic reflex thresholds Click stimulus for reflex Multiplex Pulsed-Tone Stimuli for reflex Pre-defined protocols and customizable user tests Eustachian Tube Function - Intact or Perforated TM Stand alone and PC enabled Stores 100 test sessions Comments with wireless keyboard EMR/EHR Compatible Audiometric Data Management As hearing healthcare moves to EMR and EHR, it is important for audiologic and tympanometric equipment to be compatible with data management solutions. With a single button press, test data is transferred from the instrument to the GSI Suite software where it is stored and a report may be generated. GSI Suite is compatible with network solutions and business management software. Integrate GSI Suite and Noah 4 for hearing aid fittings. Counseling overlays provide clinicians with tools to describe hearing test results to their patients. Customize reports with the comprehensive report designer by adding comments, tables and check boxes to describe your audiologic data. Save time by defining locations for audiometric reports and print to file with a click of a button from GSI Suite. GSI Suite GSI Suite captures, saves and shares patient information and provides custom reporting to support the needs of the contemporary clinic. GSI Suite is available as a Noah module for seamless integration to hearing aid fittings.

Evaluate and Diagnose the Middle-Ear with Ease and Precision With the TympStar Pro, testing and analysis of the middle-ear is efficient and precise. From integrated protocols to automatic functionality, evaluations will be completed quickly and accurately. Diagnostic Tympanometry The components of tympanometry, Y, G and B are recorded and stored simultaneously for every tympanogram tracing. The audiologist may access all immittance components for additional diagnostic information when test results are questionable. Acoustic Reflex Threshold Evaluate stapedial reflexes and observe reflex growth when increasing intensity. Whether manual or automatic testing is completed, every tracing will be displayed. Utilizing reflex growth when interpreting test data adds value and ensures accuracy. Eustachian Tube Function (ETF) With a single touch to the screen, access ETF-Intact or ETF-Perforated protocols. ETF-Intact test results are displayed in a table showing ear canal volume, tympanogram peaks, and peak pressure shifts in dapa making analysis quick and easy. Patient instructions during measurements may be used as a guide ensuring consistency in testing. ETF-Perforated test notifications guide the clinician throughout the test. Screening Tympanogram Perform a fast evaluation of the mechanical acoustic properties of the ear in the screening mode. Automatic start with seal for both 226 and 1,000 Hz probe tones ensures a fast analysis of the middle-ear. Test up to four screening reflexes using any combination of ipsilateral or contralateral stimulation. Acoustic Reflex Decay After establishing reflex thresholds, transition to acoustic reflex decay testing with one button press. The appropriate stimulus level for each test frequency will be set automatically and is based on the stored reflex threshold.

tympstarpro MIDDLE-EAR ANALYZER Precise The TympStar Pro is a comprehensive middle-ear analyzer which takes precision to the next level. Evaluate neural integrity, reflex pathways and Eustachian tube function with one touch. Have complete confidence during reflex threshold testing with artifact-free tracings. Eliminate the null point that cancels out the reflex with multiplex pulsed-tone stimulation for ipsilateral reflex recordings. Reliable Grason-Stadler has over 65 years of experience manufacturing instrumentation for hearing healthcare professionals and is known for precise diagnostics and reliable mechanics. Operate as a stand-alone device without the worry of computer related or network failure; interface with a computer to take advantage of electronic data management. Efficient Benefit from Auto Start in both screening and diagnostic testing modes. Save time and improve accuracy by viewing multiple immittance components (Y/B/G) which are available for every recording. Use screening tympanogram and reflexes to quickly evaluate pediatric patients. Tymp Touch Technology allows hearing health-care professionals to easily change test ears and test parameters, leaving more time to interact with patients.

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER Product Specifications Dimensions and Weight Size: 16 [41 cm] W x 11 [28 cm] D x 14.5 [37 cm] H Weight: 12 lb [5.5 kg] Power Consumption: 60 Watts maximum Test Types: Tympanometry, Acoustic Reflex Threshold, Reflex Decay, Eustachian Tube Function (Intact and Perforated) Protocols: Diagnostic, Screening, Multi-component Tympanometry, Auto Sequence and User Defined Display: Internal Color Touchscreen and optional external HDMI monitor Interface: USB (keyboard, mouse, Flash Drive, PC communications) Printout: External printer Probe Tone: 226 Hz (85 db SPL ± 1.5 db) 678 Hz (72 db SPL ± 1.5 db) 1000 Hz (69 db SPL ± 1.5 db) Accuracy: ± 1% Harmonic Distortion: Less than 1% Admittance Measurements Range: 226 Hz (-10 to + 10 mmho) 678 Hz (-21.0 to +21 mmho)1000 Hz (-32.0 to +32 mmho) Sensitivity Scale: Auto Scales to Appropriate Range, Manual selection also possible in Reflex Modes only Accuracy (226 Hz): Tymp Mode: ± 5% of reading or ± 0.1 mmho, whichever is greater Reflex Mode: ± 5% of reading or ± 0.02 mmho, whichever is greater Pressure Measurements (load volume of 0.2 to 7.0 ml) Range: Normal = +200 to -400 dapa Wide = +400 to -600 dapa Accuracy: ± 10% of reading or ± 10 dapa, whichever is greater Sweep Rate: 12.5, 50.0, 200, 600 and 600/200 dapa and manual Sweep Accuracy: 10% of nominal rate Maximum limits (in 0.5cc cavity): -800 dapa and +600 dapa Reflex Measurements Stimuli: 250, 500, 1k, 2k, 4k, BBN, LBN, HBN, Click, External Input, Non-acoustic Frequency Accuracy: ± 3% Harmonic Distortion (THD): Less than 5% (measured acoustically) Noise Signals: (3 db bandwidths) Low Band: 400-1,600 Hz High Band: 1,600-4,000 Hz Broad Band: 400-4,000 Hz Intensity Range: 35 to 120 db HL Step Size: 5 db, 1 db and 2 db Calibration Accuracy: ± 3 db Step Accuracy: ± 0.5 db ON/OFF Ratio: 70 db minimum Environmental Temperature and Humidity Operating Range: Storage: +32 F [0 C] to +122 F [50 C] Operating: +59 F [+15 C] to +95 F [+35 C] Transport: -4 F [-20 C] to +122 F [+50 C] Humidity: 90% at 95 F [+35 C] (non-condensing) Atmospheric Pressure: 98 kpa to 104 kpa Accessories Supplied Probe Assembly (including contralateral insert phone) Eartip sample kit Calibration Test Cavity Cleaning kit Probe Mount Kit (shoulder, clip, wrist band) User Quick Guide Reference Instruction Manual Quality System Manufactured, designed, developed and marketed under an ISO 13485 certified quality system Compliance/ Regulatory Standards Designed, tested and manufactured to meet the following domestic (USA), Canadian, European and International Standards: IEC 60601-1, EN 60601-1 International Standards for Medical Electrical Equipment CAN/CSA-C22.2 No. 60601-1 ANSI S3.39, IEC 60645-5, ISO 389 Medical Device Directive (MDD) (ID No.: 0344) to comply with MDD 93/42/EC 501C-26 Rev A www.grason-stadler.com Grason-Stadler, 10395 West 70th Street, Eden Prairie, Minnesota 55344 800-700-2282 952-278-4402 fax 952-278-4401 e-mail info@grason-stadler.com