They aren t the same thing. Daniel Dunham

Similar documents
Capnography: The Most Vital Sign

June 2011 Bill Streett-Training Section Chief

How it Works. CO 2 is the smoke from the flames of metabolism 10/21/18. -Ray Fowler, MD. Metabolism creates ETC0 2 for excretion

Interesting Capnography Cases

Capnography (ILS/ALS)

Capnography Connections Guide

Capnography 101. James A Temple BA, NRP, CCP

OWN THE AIRWAY. Airway Management Bruce Barry, RN, CEN, CPEN, TCRN, NRP. Paramedic Program

Capnography- A Review and Renewed Perspective of its Uses and Limitations

Don t let your patients turn blue! Isn t it about time you used etco 2?

Airway Management Essentials Self-Study Guide

Capnography. Capnography. Oxygenation. Pulmonary Physiology 4/15/2018. non invasive monitor for ventilation. Edward C. Adlesic, DMD.

EMS System for Metropolitan Oklahoma City and Tulsa 2017 Medical Control Board Treatment Protocols

Capnography for Pediatric Procedural Sedation Learning Module Last revised: February 18, 2014

ETCO2 MONITORING NON-INTUBATED PATIENTS

LVADs, Supraglottic Airways and CPAP

Capnography: The Most Vital of Vital Signs. Tom Ahrens, PhD, RN, FAAN Research Scientist, Barnes-Jewish Hospital, St. Louis, MO May, 2017

CAPNOGRAPHY. 1.1 To set forth the policy and procedure for performing continuous end-tidal waveform capnography.

ASPIRUS WAUSAU HOSPITAL, INC. Passion for excellence. Compassion for people. SUBJECT: END TIDAL CARBON DIOXIDE MONITORING (CAPNOGRAPHY)

Non-Invasive Assessment of Respiratory Function. Chapter 11

Pediatric Cardiac Arrest General

Advanced Cardiac Life Support (ACLS) Science Update 2015

A silent chest is. Pediatrics II Asthma, seizures and cardiac arrest. Children are different. Cough variant asthma. Symptoms of severe distress

3/30/12. Luke J. Gasowski BS, BSRT, NREMT-P, FP-C, CCP-C, RRT-NPS

Capnography Could Make You a Rock Star!

App Update: 4.0 will be updated on July 16 th, 2017 update your app (Ontario Paramedic Clinical Guide)

The Role of Capnography in EMS. By Bob Page, AAS, NREMT-P, CCEMT-P, I/C

ACLS Prep. Preparation is key to a successful ACLS experience. Please complete the ACLS Pretest and Please complete this ACLS Prep.

Michigan Pediatric Cardiac Protocols. Date: November 15, 2012 Page 1 of 1 TABLE OF CONTENTS

current practices: education series CAPNOGRAPHY IN RESUSCITATION: PEAKS, VALLEYS, AND TRENDS DO THEY SIGNAL THE END?

Post Resuscitation (ROSC) Care

By Mark Bachand, RRT-NPS, RPFT. I have no actual or potential conflict of interest in relation to this presentation.

Michigan Pediatric Cardiac Protocols. Date: November 15, 2012 Page 1 of 1 TABLE OF CONTENTS

AVOIDING THE CRASH: OPTIMIZE YOUR PRE, PERI, AND POST AIRWAY MANAGEMENT AVOIDING THE CRASH 1: DON T INTUBATE, OPTIMIZE PRE-AIRWAY MANAGEMENT

Association for Radiologic & Imaging Nursing

Julie Zimmerman, MSN, RN, CCRN Clinical Nurse Specialist

Prepared by : Bayan Kaddourah RN,MHM. GICU Clinical Instructor

Recognizing and Correcting Patient-Ventilator Dysynchrony

Nihon Kohden America. Capnography Monitoring with the CapONE CO2 Sensor For use with the BSM 2300/4100/5100 and the BSM 6000 Series Bedside Monitors

CAPNOGRAPHY DR JOHN ROOS

SUMMARY OF MAJOR CHANGES 2010 AHA GUIDELINES FOR CPR & ECC

Scene Safety First always first, your safety is above everything else, hands only CPR (use pocket

Capnography: Not just for confirmation

STATE OF OKLAHOMA 2014 EMERGENCY MEDICAL SERVICES PROTOCOLS

Lab A Overview. Oxygenation. Ventilation. Anatomy. Prep Yourself. Prep Your Team. Prep Your Patient. Prep Your Stuff.

Appendix D An unresponsive patient with shallow, gasping breaths at a rate of six per minute requires:

Simulation 15: 51 Year-Old Woman Undergoing Resuscitation

1 Pediatric Advanced Life Support Science Update What s New for 2010? 3 CPR. 4 4 Steps of BLS Survey 5 CPR 6 CPR.

US National Standards & Guidelines Capnography for Emergency Care

Capnography: Creating a Culture of Safety! An Interview With Peggy Lange, RT!

1. When a patient fails to ventilate or oxygenate adequately, the problem is caused by pathophysiological factors such as hyperventilation.

ADVANCED AIRWAY MANAGEMENT

ACLS. Advanced Cardiac Life Support Practice Test Questions. 1. The following is included in the ACLS Survey?

Foundation in Critical Care Nursing. Airway / Respiratory / Workbook

San Benito County EMS Agency Section 700: Patient Care Procedures

INTUBATION/RSI. PURPOSE: A. To facilitate secure, definitive control of the airway by endotracheal intubation in an expeditious and safe manner

The ALS Algorithm and Post Resuscitation Care

THE FOLLOWING QUESTIONS RELATE TO THE RESUSCITATION COUNCIL (UK) RESUSCITATION GUIDELINES 2005

Ventilator Waveforms: Interpretation

Routine Patient Care Guidelines - Adult

ALCO Regulations. Protocol pg. 47

Guidelines Administrative Practice X Clinical Practice Professional Practice

Health Tech Symposium Fall, Dan Sommers P.E. EMT-P

Interfacility Protocol Protocol Title:

Northwest Community EMS System Continuing Education Class Credit Questions Respiratory Assessment January 2012

Prehospital Resuscitation for the 21 st Century Simulation Case. VF/Asystole

EMS Subspecialty Certification Review Course

ILCOR, ARC & NZRC PAEDIATRIC RESUSCITATION RECOMMENDATIONS 2010

Adult Advanced Cardiovascular Life Support. Emergency Procedures in PT

Handling Common Problems & Pitfalls During. Oxygen desaturation in patients receiving mechanical ventilation ACUTE SEVERE RESPIRATORY FAILURE

IFT1 Interfacility Transfer of STEMI Patients. IFT2 Interfacility Transfer of Intubated Patients. IFT3 Interfacility Transfer of Stroke Patients

Putting it all together: 1. The arrested patient 2. The shocked patient 3. The breathless patient

ACLS Review. Pulse Oximetry to be between 94 99% to avoid hyperoxia (high oxygen tension can lead to tissue death

NIV - BI-LEVEL POSITIVE AIRWAY PRESSURE (BIPAP)

Biphasic Capnogram in a Single Lung Transplant Recipient A Case Report

Dr. Yasser Fathi M.B.B.S, M.Sc, M.D. Anesthesia Consultant, Head of ICU King Saud Hospital, Unaizah

Airway Anatomy. Soft palate. Hard palate. Nasopharynx. Tongue. Oropharynx. Hypopharynx. Thyroid cartilage

Resuscitation Checklist

Consider Treatable Underlying Causes Early

TEACHING BASIC LIFE SUPPORT (& ALS)

ADVANCED LIFE SUPPORT

End Tidal CO2 Not All Its Cracked Up To Be The Limitations of PETCO2 In Sedation Analgesia

Other methods for maintaining the airway (not definitive airway as still unprotected):

Lesson 4-3: Cardiac Emergencies. CARDIAC EMERGENCIES Angina, AMI, CHF and AED

Lecture. ALS Algorithm

VENTILATOR GRAPHICS ver.2.0. Charles S. Williams RRT, AE-C

MICHIGAN. State Protocols. Pediatric Cardiac Table of Contents 6.1 General Pediatric Cardiac Arrest 6.2 Bradycardia 6.

Anesthesia Monitoring. D. J. McMahon rev cewood

Science Behind Resuscitation. Vic Parwani, MD ED Medical Director CarolinaEast Health System August 6 th, 2013

Advanced Airway Management PRESENTED BY: JOSIAH POIRIER RN, JOHN GRUBER FP-C

Manual Defibrillation. CPR AGE: 18 years LOA: Altered HR: N/A RR: N/A SBP: N/A Other: N/A

² C Y E N G R E M E ssignac Cardiac Arrest Resuscitation Device uob

1 Chapter 40 Advanced Airway Management 2 Advanced Airway Management The advanced airway management techniques discussed in this chapter are to

Chapter 40 Advanced Airway Management

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

Introducing the Fastrach-LMA. Prepared by Jim Medeiros, NREMT-P Regional Field Coordinator Lord Fairfax EMS Council

Learning Objectives. 1. Indications versus contra-indications 2. CPAP versus NiVS 3. Clinical evidence

Pediatric Resuscitation

INSIGHTS AND BEST PRACTICES FOR EMS AGENCIES

Friday Night [under the] Lights 2014

Transcription:

They aren t the same thing Daniel Dunham

Capnometry Displays the value (as a number) of the partial pressure of CO2

Capnography Waveform capnography shows (as a wave) the change in CO2 over time

Both are valuable, and both measure CO2, but they should be used for different things.

Why are we measuring end-tidal CO2? CO2 is a byproduct of aerobic metabolism CO2 is carried by the blood to be excreted by the lungs Respiratory rate controls the amount of CO2 in the blood End tidal CO2 can non-invasively reveal cardiac output, patient response to ventilation, and ETT placement confirmation and monitoring.

Capnometry In capnometry, the resultant value is directly correlated to the blood CO2, HOWEVER, values may not match EtCO2 is closest to PaCO2 in healthy patients, when cardiac function is not reduced In patients with reduced cardiac output, EtCO2 and PaCO2 can be very different For example, a patient in cardiac arrest (without chest compressions), EtCO2 will be very low or zero, but PaCO2 will be very high. This is because without cardiac output, blood will not be flowing to bring CO2 to the lungs to allow them to exhale the CO2.

Normal Values Normal values of PaCO2 are 35-45. Normal values of EtCO2 are approximately 35-45. The waveform of a healthy patient, will be a deep square, with sharp, straight upstroke, plateau, and downslope. (this waveform will be present in healthy patients whether they are breathing spontaneously or being ventilated via any adjunct)

Exhalation begins CO2 does not increase immediately: the first air exhaled does not contain CO2 because of airway dead space.

Exhalation continues The flat plateau shows exhalation

Exhalation ends Exhalation ends

No air movement, or inspiration A value of zero indicates inspiration or no air movement

During Intubation Following intubation, waveform capnography is much more valuable than numerical capnometry. A square waveform does not occur unless air exchange is occurring in the lungs

Esophageal Intubation This is what you can expect from an esophageal intubation. CO2 may be returned initially (due to CO2 that is already in the stomach), but it will rapidly taper off. A LOW CO2 READING IS CAUSE FOR CONCERN

PEA, Pulmonary Embolism Because EtCO2 is a function of cardiac output, if the patient is still intubated, a decreasing CO2 can also indicate low lung perfusion, could be a sign the patient has become pulseless, or is developing a PE A LOW CO2 READING IS CAUSE FOR CONCERN

Shark Fin A shark fin wave form indicates bronchospasm (asthma/copd). This occurs because exhalation requires effort, and CO2 output increases as resistance is overcome. The longer the slope lasts, the more effort is being put into exhalation, and more tired the patient is becoming, and the more effort is required in exhalation. Manage this patient aggressively, and be prepared for respiratory failure. Both of these waveforms show bronchospasm, but one is sicker than the other, which one?

Curare Cleft A Curare Cleft is a notch that can be found anywhere in a waveform, with varying depths. It is the result of spontaneous respiration from the patient This can be due to inadequate sedation, neuromuscular blockade wearing off, due to the patient resisting ventilations (usually on a mechanical vent) Fix this by more sedation or neuromuscular blockade. BVM ventilations (instead of ventilation by mechanical vent) can also improve this.

Normal Values Normal values for capnometry are 35-45. Remember that capnometry is dependent on cardiac output and the ability of CO2 to cross from blood to inspired air for exhalation. Pulselessness, low metabolic rate (like hypothermia), or interrupted metaboilc process (like occurs with cyanide poisoning when aerobic metabolism doesn t occur, CO2 is not being created) can also effect EtCO2. It s also important to remember that while there is a direct correlation between EtCO2 and PaCO2, they are not necessarily the same (however, if you obtain a PaCO2 and EtCO2 at the same time, it is ok to assume that the difference will remain the same for a reasonable amount of time; e.g., EtCO2 is 32 and PaCO2 is 36, add 4 to your changing EtCO2 to approximate PaCO2 if you make changes to how you are ventilating)

During CPR EtCO2 > 20 indicate chest compressions are being performed well Values any higher than 20 indicate the patient may have a spontaneous pulse (this will help you differentiate PEA and hypotension, and help you decide on continuing CPR or started a fluid bolus and dopamine) Values less than 10 mean chest compressions are not being performed well, ETT is displaced, or the metabolic processes are no longer occurring (i.e., the patient is dead)

For ventilation It is not uncommon to see values over 110 after intubating patients that had inadequate respirations for an extended period of time. Increasing ventilation rate results in a lower EtCO2 Goal is to maintain EtCO2 of 35-45 (hyperventilation to maintain EtCO2 of 30 in head injuries is no longer recommended) It is rarely warranted to ventilate >24 or <8/minute regardless of EtCO2; possible exceptions include DKA and hypothermia The biggest clinical benefit in EMS is to avoid hyperventilation of intubated patients

COPD/CHF discrimination EtCO2 values will be higher in patients with acute bronchoconstriction. Along with higher peak values, the baseline may become elevated.

COPD/CHF discrimination EtCO2 can be used to determine whether bronchoconstriction is present, even in patients with inaudible lung sounds. A high EtCO2 in indicative of bronchoconstriction. A normal EtCO2 is non-diagnostic (it does not rule out bronchoconstriction, or confirm pulmonary edema). If you ve determined that a patient is either having a exacerbation of COPD or CHF, but you re not sure which, EtCO2 can answer this question for you.

Continuous EtCO2 Monitoring EtCO2 is non-invasive and can be performed on any patient with any symptoms, but is strongly encouraged for all patients with respiratory distress. Continuous EtCO2 monitoring is now expected (mandatory) for all patients in which nebulized medication is administered (be sure to document this in your report) When you administer nebulized medications, you are treating bronchoconstriction, if you re going to treat bronchoconstriction, you should assess for bronchoconstriction (of course, this can be done with lung sounds, but in a loud ambulance environment and many people will less than perfect hearing, EtCO2 can be easier to assess so do both!) EtCO2 changes are an excellent indicator of the effectiveness of bronchodilators. As nebulizer is more effective, you will see EtCO2 return to normal levels, and baseline return to zero. An elevated, unchanging EtCO2 indicates that bronchoconstriction is not improving

Capnography and capnometry can be very valuable tools if you understand how they work and their limitations. In conjunction with SpO2, a normal EtCO2 range indicate a patient is being ventilated very well. A square waveform on a capnograph is nearly irrefutable and objective evidence that intubation was successful, and that ventilations are being performed properly. EtCO2 can be used on spontaneously breathing patients, ETT, King Tube, or LMA intubation, Trach or cric patients, or any other adjunct that you attach a BVM to, and the reference values do not change.