Proceedings Laparoscopy s Gestures Assessment: A Construct Study for the Validation of an Instrumented Glove

Similar documents
Index. B Basic Arthroscopic Knee Skill Scoring System (BAKSSS), , 162 Bloom s taxonomy, 22 Box trainers for arthroscopic knot tying, 64

Title: Role of portable laparoscopic simulators in surgical skills: a feasibility study

New Technologies for Surgery

Minimally Invasive Surgery Tool. Team Members: Sujan Bhaheetharan (BWIG) Ashley Huth (BSAC) Max Michalski (Communicator) Brenton Nelson (Leader)

Development of esmoca RULA, Motion Capture Instrumentation for RULA Assessment

Development and application of a hand force measurement system

FUSE TECHNICAL REPORT

Virtual Reality-based Personalized Learning Environment for Repetitive Labor-intensive Construction Tasks

Thermo Scientific Finnpipette Manual Pipetting Systems. you can handle. anything

Training Programme in OB & Gyn

Effect of mental training on short-term psychomotor skill acquisition in laparoscopic surgery - a pilot study

ON DEVELOPING A REAL-TIME FALL DETECTING AND PROTECTING SYSTEM USING MOBILE DEVICE

An Innovative Measurement in Musculoskeletal Rehabilitation Using 3D Motion Analysis

Evaluating Tactile Feedback in Graphical User Interfaces

Content and Construct Validation of a Robotic Surgery Curriculum Using an Electromagnetic Instrument Tracker

Laparoscopy training essentials

Squid: Exercise Effectiveness and. Muscular Activation Tracking

Reliability and validity of the GymAware optical encoder to measure displacement data

Force Characteristics of Trocar Insertion Abdomen in Laparoscopic Surgery

ISE Italian School of Endoscopy Hysteroscopy lv.1 Salerno Jan , 2018 Ergonomics in Hysteroscopy

Evaluation of Interactive Systems. Anthropometry & Anatomy

To Advance Clinical Performance

professional rehabilitation PRODUCT RANGE by

The Effects of Carpal Tunnel Syndrome on the Kinematics of Reach-to-Pinch Function

Face, content, construct and concurrent validity of dry laboratory exercises for robotic training using a global assessment tool

Prevalence of Musculoskeletal Disorders. Rose Moss, MN, RN, CNOR Perioperative Nurse Consultant/Medical Writer Moss Enterprises, LLC Westcliffe, CO

An Investigation of Hand Force Distribution, Hand Posture and Surface Orientation

Experimental evaluation of the accuracy of the second generation of Microsoft Kinect system, for using in stroke rehabilitation applications

ScienceDirect. Rotational traction behaviour of artificial turf

Accuracy and validity of Kinetisense joint measures for cardinal movements, compared to current experimental and clinical gold standards.

Virtual reality simulation training can improve technical skills during laparoscopic salpingectomy for ectopic pregnancy

ANTICIPATING DYNAMIC LOADS IN HANDLING OBJECTS.

Modeling the behavior of human body tissues on penetration A. Conci, A. L. Brazil, D. Popovici, G. Jiga, F. Lebon

Pilot Study: Performance, Risk, and Discomfort Effects of the RollerMouse Station

What We Do To Reduce Work-related Musculoskeletal Disorders and Injuries at Occupational Ergonomics and Biomechanics (OEB) Laboratory

FLx. USER INSTRUCTIONS Version. 01 STRONGARM ERGOSKELETON. Postural Support Device FLx

Characterizing the Learning Effect in Response to Biofeedback Aimed at Reducing Tibial Acceleration during Running

7 Grip aperture and target shape

Development of an Electronic Glove with Voice Output for Finger Posture Recognition

Food Intake Detection from Inertial Sensors using LSTM Networks

16th Coaches Conference 2011 Slovenia

ECHOGRAPHIC EXAMINATION IN EMERGENCY TELE-OPERATED USING A ROBOTIC ARM. APPLICATION TO ABDOMINAL & CARDIOVASCULAR PATHOLOGY AND OBSTETRICS.

Overview. Learning Objectives

ThruPort Ergonic Minimal Incision Instrumentation

Rooter S. Compact, Cordless Endodontic Motor

Personalized Solutions. Portfolio Brochure

User Guide ActiGraph GT9X Link + ActiLife

Instructions for Use

TWO HANDED SIGN LANGUAGE RECOGNITION SYSTEM USING IMAGE PROCESSING

Application of ecological interface design to driver support systems

Health Utilities of Type 2 Diabetes-Related Complications: A Cross-Sectional Study in Sweden

FILE INFORMATION. 3RD GENERATION PROFESSIONAL MULTI-USER PACK and what generation are you?

Analyzing Hand Therapy Success in a Web-Based Therapy System

Finger spelling recognition using distinctive features of hand shape

Lecture 12: Psychophysics and User Studies

Best Practice: SPORTS

The potential effect of a vibrotactile glove rehabilitation system on motor recovery in chronic post-stroke hemiparesis

Proceedings Design of a Wireless Wearable DAQ System for the Evaluation of Sports Performances

TURKISH SIGN LANGUAGE RECOGNITION USING HIDDEN MARKOV MODEL

Agitation sensor based on Facial Grimacing for improved sedation management in critical care

Measurement of welder's movement for welding skill analysis

Accelerometer can accurately measure training load in badminton

Ergonomic Test of Two Hand-Contoured Mice Wanda Smith, Bob Edmiston, and Dan Cronin Global Ergonomic Technologies, Inc., Palo Alto, CA ABSTRACT

Pushing the boundaries

Abstract. A novel device to improve sitting posture. Hoda Dalimi (1) Ali Ghorbani (2) Anoushirvan Kezam nejad (3) Mohammad Hossein Alizadeh (4)

Hitachi Aloka Medical manufactured one of the world s first diagnostic ultrasound platforms, and today this imaging modality has become the first

Operator tooling for the Touch-up Procedure

AVR Based Gesture Vocalizer Using Speech Synthesizer IC

Effects of Capital Collar Enhanced on Head-Cervical Movements in Comparison with Miami J Advanced and Aspen Vista TX Collars

Monitoring of Physical Activity

DESIGN AND IMPLEMENTATION OF A MECHATRONIC SYSTEM FOR LOWER LIMB MEDICAL REHABILITATION

How Can Dynamic Computerized Posturography Help in Cases of Dizziness?

Target contact and exploration strategies in haptic search

An Investigation into the Teaching of Injection Procedures in Dental Education and Other Clinical Skills Programmes Using a Virtual Haptic Simulator

TriAuto mini Compact, Cordless Endodontic Handpiece

An Investigation of Social Identity in Smart Healthcare System for Physiotherapy Exercises

Thesis Rehabilitation robotics (RIA) Robotics for Bioengineering Forefront research at PRISMA Lab and ICAROS Center

Augmented reflection technology for stroke rehabilitation a clinical feasibility study

CITY OF TURLOCK ERGONOMICS POLICY

Combining EEG with Heart Rate Training for Brain / Body Optimization. Combining EEG with Heart Rate Training. For Brain / Body Optimization

HIWIN Thesis Award 2007

carpal tunnel get back to life Patient information about Endoscopic Surgery for the treatment of Carpal Tunnel Syndrome

Control principles in upper-limb prostheses

The Ergonomic Alternative

Samantha McGlone B.Ed., Gabby Rabadam, Veronica Young Gurtej Grewal, Ph.D, Bijan Najafi PhD, Daniel Latt, M.D.,Ph.D Human Movement Biomechanics

Provider Dashboard User's Manual

The 3E Approach to Eliminating Musculoskeletal Injuries: Utility Spotlight

LION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:

The PinTrace system. medical robotics

Toolbox for Reducing Sprains and Strains

Faculty of Physical Education & Sport Sciences, Diala University. Seif El Din Watheq :

Educational system of laparoscopic gastrectomy for trainee how to teach, how to learn

Navigator: 2 Degree of Freedom Robotics Hand Rehabilitation Device

Notes on Medical Robotics and Computer-Integrated Surgery, Russell H. Taylor, Arianna Menciassi, Gabor Fichtinger Paolo Fiorini and Paolo Dario

Ontario s Move to Hot Mix Asphalt Pavement Smoothness Acceptance Using High Speed Inertial Profilers

BACKGROUND: The purpose of this study was to determine whether low-fidelity arthroscopic simulation training improves basic ankle arthroscopy

CSESaR Center for Simulation Education and Safety Research

Analysis of Visual Properties in American Sign Language

Transcription:

Proceedings Laparoscopy s Gestures Assessment: A Construct Study for the Validation of an Instrumented Glove Gaelle Thomas 1,2,3, *, Juan Diego Lemos 2,3, Georges Soto-Romero 1,3, Jean-Yves Fourniols 3 and Alher Mauricio Hernández 2 1 Institut Supérieur d Ingénieurs de Franche-Comté, 25000 Besançon, France; gsotorom@laas.fr 2 GIBIC, Bioengineering Department, University of Antioquia, Medellín, Colombia; juan.lemos@udea.edu.co (J.D.L.); alher.hernandez@udea.edu.co (A.M.H.) 3 LAAS-CNRS, Université de Toulouse, CNRS, 31000 Toulouse, France * Correspondence: gaelle.thomas.be@gmail.com Presented at the Eurosensors 2017 Conference, Paris, France, 3 6 September 2017. Published: 11 August 2017 Abstract: The GIBIC research team, from UdeA, and S4M from LAAS-CNRS, designed a glove with inertial sensors (IMU) for quantifying surgeons dexterity. A previous study validated its capacity to accurately rank participants, compared to a video evaluation, during neurosurgery training. The objective of this work is to check this validity for laparoscopic surgery, compared with a gold-standard simulator, the LapSim (Surgical Science ). For this purpose, the inertial basic data of the sensors were processed into quantified score comparable with the LapSim scores. A trial was designed and conducted during one month with nine students training on specific LapSim tasks. Keywords: Instrumented Glove; IMU sensor; laparoscopy; training 1. Introduction Accuracy, speed, and economy of effort are crucial determinants of surgical skills. However, quick reaction performance, team coordination in the context of long procedures, and trade-offs between service and safety still have a high potential of error for a surgeon [1]. Reports published in recent years ([2,3]) have documented the same observation: there s an important annual number of medical adverse events. It costs a lot in terms of hospital expenses and patients satisfaction. Therefore, surgery evaluation methods are being more demanded, especially for laparoscopy that is more challenging compared to open surgery. Indeed, surgeons must operate in a three-dimensional space through a two-dimensional projection on a monitor, which results in a loss of depth perception. Also, the length of the instruments induces a loss of precision, as well as a lack of tactile feedback. Thus, reinforced training must be carried out, whether for already experienced abdominal surgeons or for residents, because of the longer traditional learning curve. Beyond the limits of current traditional methods (cadavers, animals, box-trainers), an open problem remains to dispose of a robust method to objectively quantify resident s apprenticeship. Virtual Reality (VR) simulators aim to complement traditional training tasks by providing high quality simulations in surgery exercises. It has been proved to be efficient for laparoscopic training. The more sophisticated VR simulators measure the trainee performance through haptic devices that capture movements but not fine movements that could be captured with an Instrumented Glove [4]. Proceedings 2017, 1, 599; doi:10.3390/proceedings1040599 www.mdpi.com/journal/proceedings

Proceedings 2017, 1, 599 2 of 5 2. Materials and Methods 2.1. The Instrumented Glove [4] The IGlove is made of two parts: an elastic-textile glove with textile small pockets for the sensors, and a hub, strapped to the wrist, for the signal acquisition. The sensors are Inertial Measurement Units (IMU, model MPU-9250, InvenSense) and embed a 3-axis accelerometer, a 3-axis gyroscope and a 3-axis magnetometer. Up to 8 channels can be used at the same time, for capturing different phalanges motion. In this study, when analyzing the hand and fingers displacements during laparoscopic exercises, four sites were chosen: thumb, index, middle finger and upper hand face. 2.2. Study Characteristics The study was designed by referring to a survey paper [5] reviewing laparoscopic Simulation- Based Training studies, from 1997 to 2011. The hired population were nine engineering students (19 to 28 years old, including 3 men, all right-handed), with no prior knowledge in laparoscopy. Their skill improvement was assessed during a month on different LapSim tasks. Each participant had ten training sessions, with only four recorded sessions. Each session was conducted as follows: two warming exercises (Camera navigation, Instrument navigation) and three recorded exercises (Coordination, Grasping, Cutting). They are Basic Skills tasks of the LapSim software. The chosen parameters were the mainly found in the literature, namely task duration, path length (in rotation and translation) and number of movements. 2.3. IGlove Data Processing The selected parameters were extracted from the IMU s thanks to a MATLAB data processing. The mainly used sensor was the gyroscope. A sliding-hanning-window filter was used to smooth the signals (width: 2 s). The task duration (time between first and last movement) was deduced from the number of peaks as described in Figure 1a. The angular path (path taken by the sensor of the hand, in degrees) was calculated by estimating the integration of the gyroscope signal. (a) (b) Figure 1. (a) Time extraction using a gyroscope signal and sensor 1 (task Grasping). (b) Exponential approximation of the task duration decrease (task Coordination, LapSim data, 9 participants). 2.4. Validation of the IGlove The extracted data were compared with two parameters from the LapSim reference data: the task duration and the angular path length. Different analyses can be conducted: to compare the parameters value, to compare the parameters evolution and to compare the participants ranking. Comparison of the parameters value. The parameters error e was defined as the average difference between the IGlove values and the LapSim values, for one parameter, such as:

Proceedings 2017, 1, 599 3 of 5 N S e = 1 N S x IGlove x LapSim 100 (1) x LapSim i=1 j=1 where N is the number of participants, S the number of sessions, x IGlove the value of the parameter recorded by the IGlove and x LapSim the value of the parameter recorded by the LapSim. x IGlove was obtained using only sensor 1. The smaller e is, the closer to the LapSim is the IGlove. Comparison of the parameters evolution. The ratio between the first and the last session of each participant, for the two parameters was calculated. It gives a first idea of how well the IGlove evaluates the total improvement of a parameter, after 10 sessions of repetition. Another way to assess the evolution of the parameters is to fit them to a known trend line. Then, the trend lines have coefficients that are elements of comparison between the IGlove and the LapSim. A four-parameter decreasing exponential (Figure 1b) fits best the data (R 2 = 0.9726), y model = Ae BS + Ce DS (2) Therefore, to compare the IGlove assessment with the LapSim assessment, the different coefficients A, B, C and D are evaluated and compared for both equipment. The closer to the LapSim it is, the better the IGlove is to assess the participants evolution. Comparison of the participants rank. Outcome of each participant is compared to a reference. For assessing their evolution, this reference is their first session, equal to 1. The ratios between session 1 and session x is displayed at each step of the training. It is a way of evaluating objectively the speed of apprenticeship and the situation of the trainee in his skill acquisition curve. The curves are elements of comparison between the IGlove and the LapSim. For assessing their best performance, the reference is an experienced surgeon in laparoscopy (8 years of practice) whose outcomes are rated as a 100%. The closer to this score a participant is, the higher it will be in a rank for one given parameter. Those ranks are also elements of comparison. 3. Results Comparison of the parameters value. For the parameter task duration, the estimated error of the IGlove is of 23.5%. For the parameter angular path, the estimated error of the IGlove is of 72.2%. Comparison of the parameters evolution. The ratios between the first and last session of each task for the parameters task duration and angular path are presented in Table 1. The different modelling parameters A, B, C and D were calculated for the parameters task duration and angular path, and the percentages of difference between the IGlove and the LapSim outcomes were calculated, being the coefficients with the lower differences between IGlove and LapSim the B and D, and the more similar results were obtained in the task Grasping. Table 1. Average ratios between first and last sessions (difference with LapSim values). Task Duration Angular Path LapSim IGlove Error (%) LapSim IGlove Error (%) Coordination 0.4967 0.4629 6.8% 0.7308 0.7432 1.7% Grasping 0.6463 0.6156 4.7% 0.5104 0.7437 45.7% Cutting 0.7996 0.6979 12.7% 0.6586 0.9467 43.7% Comparison of the parameters ranking. In Figure 2 is presented an example of the curves of apprenticeship calculated from the IGlove and the LapSim, for the task Grasping (participants TR02 to TR09). Table 2 displays one of the possible ranking of the participants (task Grasping).

Proceedings 2017, 1, 599 4 of 5 (a) (b) Figure 2. Examples of curves of apprenticeship, parameter task duration, (a) IGlove, (b) LapSim. Table 2. Comparison of ranking using all the parameters (blue: similar ranks, REF: expert surgeon). 1 ST 2 ND 3 TH 4 TH 5 TH 6 TH 7 TH 8 TH 9 TH LAPSIM REF TR08 TR06 TR04 TR07 TR09 TR03 TR05 TR02 IGLOVE REF TR03 TR08 TR06 TR04 TR05 TR09 TR07 TR02 4. Discussion The selected tasks were basic enough for every participant to achieve a quantifiable improvement. The selected parameters extracted from the IGlove sensors seemed all relevant to show how the participants went towards a more economical gesture. Their absence of knowledge or skills in laparoscopy made their progression clearly identifiable. The IMU sensors give a lot of information, their place on the IGlove has to be well chosen to balance redundant and additional information. Finally, the physical and psychological discomfort has to be taken into account as it appeared the participants felt much more at ease practicing without being observed and measured. The IGlove outcomes are always higher than the LapSim data. It is because of the movement detection method: it takes into account additional movements that are not parts of the exercise itself, while the LapSim software doesn t. The comparison of the curves of apprenticeship shows a good correlation, it leads to validate the IGlove as a good equipment to anticipate the dynamic of learning. If the exponential approximation of the apprenticeship curves seems reliable, the comparison of the coefficients shows that it can be improved to have the IGlove and LapSim models match. With regard to the obtained classifications of the trainees, there are mainly consistent between both equipment. A more advanced method of classification could be designed, by weighting certain parameters and determining the number of common points less arbitrarily. 5. Conclusions As a preliminary study, it appears that the IGlove is able to assess an evolution of dexterity as the LapSim software would do. A model of curve of apprenticeship can be extracted and used to predict the learning dynamics of a trainee. The data process can be improved for more accuracy. Its design can also be reconsidered, as its ergonomics directly influences the outcome of an exercise. This work shows that the possibilities of utilizing IMU sensors for surgical skills assessment are immense, particularly in those simulators that don t have haptic parts. The good correlation between IGlove and LapSim suggests possibilities to be used as complementary tools including sophisticated processing techniques in those tasks that include fine movements. It also shows that still a lot of work can be done for discovering all the ways of assessing a surgeon gesture. Acknowledgments: This work was partially supported by Republic of Colombia, SGR-RutaN-139C. Conflicts of Interest: The authors declare no conflict of interest.

Proceedings 2017, 1, 599 5 of 5 References 1. Chamberlain, N. The folly of rewarding silence with hoping for open reporting of reporting adverse medical events. N. Z. Med. J. 2008, 121, 58 66. 2. DREES. Enquête Nationale sur les Évènement Indésirables Graves Associés aux Soins; DREES: Fort Mitchell, KY, USA, 2011. 3. Institute of Medicine. To err Is Human: Building a Safer Health System; National Academies Press: Washington, DC, USA, 1999. 4. Lemos, J.D.; Hernandez, A.M.; Soto-Romero, G. An Instrumented Glove to Assess Manual Dexterity in Simulation-Based Neurosurgical Education. Sensors 2017, 17, 988. 5. Zendejas, B.; Brydges, R.; Hamtra, S.J.; Cook, D.A. State of Evidence on Simulation-Based training for Laparoscopic Surgery. Ann. Surg. 2013, 257, 586 593. 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).