Calibration Standards

Similar documents
PEEK Columns & Guard Columns

PEEK SS Columns & Guard Columns

TSKgel Hydrophobic Interaction Chromatography Columns

TSKgel Size Exclusion Chromatography Columns

Tosoh Bioscience llc Distributed by Phenomenex in the USA, Canada, and Puerto Rico only.

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Purification - Flash Chromatography

Product Guide for LudgerSep TM C3 anion exchange HPLC Column for Glycan Analysis

HPLC. Varian Dynamax Preparative HPLC Columns

UHPLC Column and System Protection Essentials

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

HC-75 Calcium Form. 305 x 7.8 mm HC-75 Calcium Form (P/N 79436)

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

Rev. CO Packed Columns for Ion Chromatography

GPC columns TOSOH BIOSCIENCE

InfinityLab Purification Capillary Kits

CANNABIS TESTING ACCESSORIES

TSKgel GPC columns TOSOH BIOSCIENCE

Protect your expensive HPLC and UHPLC columns from premature failure with MAC-MOD Pre-Column Filters

SeQuant ZIC -HILIC For all who expect more...

Hypersil BDS and Hypersil Classical HPLC Columns

SeQuant ZIC -HILIC For all who expect more...

Purification - Flash Chromatography

Choosing Preparative Columns

size exclusion

Selection and Optimization of the Sample Introduction System

Compressor Accessories

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Chromatography Catalog

Sepax Technologies, Inc.

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Ultra Columns HPLC COLUMNS

BabyBio IMAC columns DATA SHEET DS

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2

Ultra Columns. also available. ordering note

Membrane Chip Interface and Accessories

Gas Chromatography Syringe Selection Guide

2 Tosoh bioscience LLc. suite 100 king of Prussia, pa 19406, USA.

GPC columns TOSOH BIOSCIENCE

Relative Measurement of Zeaxanthin Stereoisomers by Chiral HPLC

Contents. 01 Welded Syringe Filter Economy Syringe Filter Sterile Syringe Filter Membrane Filter 21

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

Hamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles

HTEC-500 and 700 Series Related

More accurate results.

cataleg-inl-2007-def6.indd /01/ :27:30

CORESTA RECOMMENDED METHOD N 8

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide

Sample Preparation Quick Reference Guide

Agilent Technologies Prep LC Columns

EASI-EXTRACT MULTI-VIT B (LGE) Product Code: P183 / P183B

Agilent Captiva Sample Preparation Filtration Portfolio GAUGE THE DIFFERENCE FILTRATION CAN MAKE

HxSil C18, 4.6 x 150mm, 5um (P/N 79868) 1. Oxybenzone 2. Octocrylene 3. Octyl Methoxycinnamate 4. Avobenzone (Parsol 1789) 5.

Selecting The Right Syringe

ICP-OES Organics Kit Installation Instructions

Product Guide for LudgerSep TM R1 HPLC Column for Glycan Analysis

HPLC-MALDI-TOF Mass Spectrometry for the Analysis of Complex Polymers

Operating Instructions

Keep it Clean with Strata -X

ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog

Needle Gauge. Needle OD (mm) Needle ID (mm)

Plastic Storage Bottles. Product Selection Guide

HILIC COLUMNS TOSOH BIOSCIENCE

EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B

Hyper-fast & Super-rugged

Determination of Patulin in Apple Juice Using SPE and UHPLC-MS/MS Analysis

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available

Lipidomic Analysis by UPLC-QTOF MS

Hydrophobic Interaction Chromatography

EASIMIP TM PATULIN Product Code: P250 / P250B

Liquid Chromatography Syringes

176 YMC Chiral Columns

Quantity in. Unit of Measure. (If Applicable) 1 each Anode Buffer Reservoir Jar 1 Applied Biosystems $101.65

Overview on YMC Column Hardware and Phases

EASI-EXTRACT BIOTIN Product Code: P82 / P82B

Ultimate Core Performance to Maximize Your Investment

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Title Revision n date

COMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Store at 2-8 C. Do not freeze. Store at 2-8 C. Do not freeze.

Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results

Filtration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products

Supporting Information for. Interaction of Spin-Labeled HPMA-based Nanoparticles with Human Blood Plasma Proteins

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

Ordering Information You may contact us via phone, fax, , or through our website.

CAMAG TLC-MS INTERFACE

Ordering Information You may contact us via phone, fax, , or through our website.

Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES

CE Columns and Accessories

Columns for HPLC. Columns for HPLC

Super Clean TM. Gas Filters BIG TRAP INLINE FILTERS. Ideal for Central Purifying Solutions Largest Big Trap Available High Pressure Stainless Steel

Overview on YMC Column Hardware and Phases

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Ordering Information You may contact us via phone, fax, , or through our website.

Synthesis of Sequence-Controlled Acrylate Oligomers. via Consecutive RAFT Monomers Additions

Analytical and Preparative SFC Columns

COMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Store at 2-8 C. Do not freeze. Store at 2-8 C. Do not freeze.

Determination of Carbohydrates in Kombucha Using HPAE-PAD

Transcription:

Calibration Standards/ Calibration Standards TSKgel standards polystyrene TSKgel standards poly(ethylene oxide) PStQuick polystyrene calibration standards TSKgel guard column products Fittings Pre-injector filters Pre-column filters Tubing For more info visit: www.tosohbioscience.com 201

202 Call customer service: 866-527-3587, technical service: 800-366-4875

Calibration Standards/ About: Calibration Standards The TSKgel standards product line consists of bulk quantities of polystyrene and polyethylene oxide standards of varying molar mass and pre-mixed quantities of polystyrene polymers for calibration of GPC columns (PStQuick). All standards are tested to certify quality and reliability. Testing is done by laser light scattering, except for the standards below 1,000 Da, which are tested by size exclusion chromatography. TSKgel polystyrene bulk calibration standards are used to calibrate size exclusion columns for subsequent analysis of unknown samples. The standards range from 400 to 2.1 10 7 Da. TSKgel polyethylene oxide calibration standards were developed to meet the demand for a high molar mass aqueous standard polymer. Synthesized by living anionic polymerization, this product, like its sister product TSKgel polystyrene calibration standards, has an extremely sharp molar mass distribution. The polymer is available in seven types, with molar mass values between 1.8 10 4 and 1.0 10 6 Da. The polymer may be used as a test sample for liquid chromatography, such as SEC using water (buffer) or alcohol as a solvent for evaluating the performance of a separation membrane, or for calibrating light-scattering photometers and other molar mass analysis devices. It may also be used for biochemical research. PStQuick polystyrene calibration standards contain premixed quantities of polystyrene polymers in autosampler vials for calibration of GPC columns. Addition of solvent is all that is required for easy preparation and analysis. Twelve different kits containing polystyrene polymers of various molar masses are available. Of the 12 kits, 9 are individual kits, each containing 3 to 5 polystyrene polymers. The remaining 3 are composite kits containing 2 or 3 of the individual kits. Ordering Information - TSKgel polystyrene calibration standards Part # Description Weight 2016 Price 05202 A-300, 400 Da 10 g $463 05203 A-500, 530 Da 10 g $463 05204 A-1000, 950 Da 10 g $463 05205 A-2500, 2,800 Da 5 g $245 05206 A-5000, 6,200 Da 5 g $245 05207 F-1, 1.0 10 4 Da 5 g $245 05208 F-2, 1.7 10 4 Da 5 g $245 05209 F-4, 4.4 10 4 Da 5 g $245 05210 F-10, 1.0 10 5 Da 5 g $245 05211 F-20, 1.9 10 5 Da 5 g $245 05212 F-40, 4.2 10 5 Da 5 g $245 05213 F-80, 7.8 10 5 Da 5 g $245 05214 F-128, 1.3 10 6 Da 1 g $119 05215 F-288, 2.9 10 6 Da 1 g $119 05216 F-380, 3.8 10 6 Da 1 g $119 05217 F-450, 4.5 10 6 Da 1 g $227 05218 F-550, 5.5 10 6 Da 1 g $302 05219 F-700, 6.8 10 6 Da 1 g $302 05220 F-850, 8.4 10 6 Da 1 g $302 05221 F-2000, 2.1 10 7 Da 1 g $606 06476 Oligomer Kit, A-500 thru F-128 12 1 g $889 06477 High MW Kit, F-10 thru F-2000 12 1 g $1,948 For more info visit: www.tosohbioscience.com 203

Ordering Information - TSKgel polyethylene oxide calibration standards Part # Description Weight 2016 Price 06211 SE-2, 1.8 10 4 Da 0.5 g $133 06212 SE-5, 3.9 10 4 Da 0.5 g $133 06213 SE-8, 8.6 10 4 Da 0.5 g $133 06214 SE-15, 1.5 10 5 Da 0.5 g $133 06215 SE-30, 2.5 10 5 Da 0.5 g $133 06216 SE-70, 5.9 10 5 Da 0.5 g $133 06217 SE-150, 1.0 10 6 Da 0.5 g $133 05773 Polyethylene Oxide Kit, SE-2 thru SE-150 7 0.2 g $375 Ordering Information - PStQuick polystyrene calibration standards To calibrate TSKgel SuperMultiporeHZ columns Part # Description Remarks Calibration Range Contents Vials 2016 Price 21912 PStQuick MP-N For SuperMultiporeHZ-N 530 to 4.4 10 4 A-500, A-5000, F-4 60 $927 21913 PStQuick MP-M For SuperMultiporeHZ-M 530 to 8.0 10 5 A-500, A-5000, F-10, F-80 21914 PStQuick MP-H For SuperMultiporeHZ-H 950 to 5.5 10 6 A-1000, F-1, F-10, F-80, F-550 60 $927 60 $927 To calibrate TSKgel H-type mixed bed columns Part # Description Remarks Calibration Range Contents Vials 2016 Price 21915 PStQuick Kit-L For H-type N grade 530 to 4.2 x 10 5 PStQuick E, F 40** $642 21916 PStQuick Kit-M For H-type M grade 530 to 2.9 10 6 PStQuick C, D 40** $642 21917 PStQuick Kit-H For H-type H grade 530 to 8.4 10 6 PStQuick A, B, C 60* $927 *20 of each type 3, **20 of each type 2 To calibrate other TSKgel GPC columns Part # Description Remarks Calibration Range Contents Vials 2016 Price 21911 PStQuick A For other GPC columns 2,800 to 8.4 10 6 A-2500, F-2, F-20, F-128, F-850 21910 PStQuick B For other GPC columns 950 to 5.5 10 6 A-1000, F-1, F-10, F-80, F-550 21909 PStQuick C For other GPC columns 530 to 2.9 10 6 A-500, A-5000, F-4, F-40, F-288 21908 PStQuick D For other GPC columns 2,800 to 1.3 10 6 A-2500, F-2, F-20, F-128 21907 PStQuick E For other GPC columns 950 to 4.2 10 5 A-1000, A-5000, F-4, F-40 21906 PStQuick F For other GPC columns 530 to 1.9 10 5 A-500, A-2500, F-2, F-20 204 Call customer service: 866-527-3587, technical service: 800-366-4875

Calibration Standards/ About: Parts and Accessories Tosoh Bioscience offers a limited line of replacement parts for its columns and guard columns. With the introduction of TSKgel BioAssist series, the TSKgel column line consists of stainless steel, glass and PEEK columns. The tubing, fittings and frits in the stainless steel TSKgel columns are manufactured from 316-grade stainless steel. The top and bottom end-fittings are engraved with the pore size of the frit. If the top frit plugs, the entire endfitting can be removed and replaced. Order the appropriate replacement fitting according to the ID of the column. Stainless steel end-fittings will connect to the 10-32 PEEK or stainless steel nuts and ferrules on a standard HPLC system. The end-fittings on the glass columns contain Pyrex frits with a nominal 10 μm pore size. The materials in the glass column fittings that come into contact with the sample and the mobile phase are chlorotrifluoroethylene and tetrafluoroethylene. The end-fittings will connect to 1/4-28 and also to M6 nuts and ferrules. Tosoh Bioscience recommends that each column be protected by a guard column and filter. Guard columns are listed with corresponding columns in each section of this catalog. We recommend installing a pre-column filter in front of the (guard) column to avoid clogging the top frit, particularly when working with columns that contain smaller than 5 μm particles. In addition, when suspecting debris from the breakdown of pump seals, we have found it beneficial to use a pre-injector membrane filter to prevent any particulates from reaching the injector and/or (guard) column. Ordering Information - TSKgel guard holders Part # Description ID (mm) Length (cm) 2016 Price 07093 TSKgel Guardgel Holder for 7.5 mm ID SS columns 6 1 $298 08809 TSKgel Guardgel Holder for 5 mm ID and 8 mm ID glass columns 8 1 $405 16106 TSKgel Guardgel Holder for 21.5 mm ID SS columns 20 1 $356 18206 TSKgel Guardfilter Holder for TSKgel Super-ODS, -Octyl, -Phenyl guard filters $183 19018 TSKgel Guard Cartridge Holder for 3.2 mm ID cartridges 3.2 1.5 $364 19308 TSKgel Cartridge Guard Holder for 2 mm ID columns 2 1 $363 Ordering Information - fittings Part # Description 2016 Price 16566 One-Piece Fingertight Fitting, 1/16", 10-32, PEEK, ea $15 03400 Plug, 1/4-28 for glass column fitting, pk 10 $39 02342 Male Nut and Ferrule, 10-32, 1/16" SS, pk 2 $31 05748 End-fitting w/ Fixed 10 µm Frit for 7.5 mm ID SS columns $98 06191 End-fitting w/ Fixed 10 µm Frit for 21.5 mm ID SS columns $355 07619 End-fitting w/ Fixed 2 µm Frit for 4.6 mm ID SS columns $98 08092 End-fitting w/ Fixed 2 µm Frit for all 6 mm ID SS columns $98 08095 End-fitting w/ Fixed 2 µm Frit for all 7.8 mm ID SS columns $98 08600 End-fitting w/ 10 µm Pyrex Frit for all 8 mm ID Glass columns $98 13998 End-fitting w/ Fixed 1 µm Frit for NPR columns $85 16104 End-fitting w/ 10 µm Pyrex Frit for all 5 mm ID Glass columns $85 16105 End-fitting w/ 10 µm Pyrex Frit for all 20 mm ID Glass columns $232 18254 End-fitting w/ Fixed 1 µm Frit for TSKgel SuperH columns $72 18255 End-fitting w/ Fixed 1 µm Frit for TSKgel Super Series columns $87 18544 End-fitting w/ Fixed 2 µm Frit for TSKgel ODS-80TS QA columns $72 18545 End-fitting w/ Fixed 2 µm Frit for 2 mm ID SS columns $89 19834 End-fitting w/5 µm Frit for 4.6 mm ID TSKgel BioAssist columns $144 19838 End-fitting w/5 µm Frit for TSKgel BioAssist PEEK SWXL columns $219 For more info visit: www.tosohbioscience.com 205

Ordering Information - filters and frits Part # Description 2016 Price 14594 Pre-Injector Membrane Filter Holder, SS $312 03409 13 mm Nylon Membrane Filter.45 µm for p/n 14594, 100 pk $116 03410 Low Dead Volume Pre-Column Filter with 0.5 µm SS Frit -- for general use $137 03411 Replacement 0.5 µm SS Frits for 2 mm ID SS columns, 10 pk $85 03430 Replacement 2 µm SS Frits for p/n 03432, 10 pk $40 Ordering Information - tubing Part # Description 2016 Price 02353 Teflon Tubing, 1/16" x 0.01" x 150 cm $47 02354 PEEK Tubing, 1/16" x 0.01" x 150 cm $40 02359 Tefzel Tubing, 1/16" x 0.03" x 150 cm $73 02374 Stainless Steel Tubing, 1/16" x 0.01" x 10 cm, 5 pk $40 02375 Stainless Steel Tubing, 1/16" x 0.02" x 10 cm, 5 pk $39 206 Call customer service: 866-527-3587, technical service: 800-366-4875