Pacing the Heart. Ayo Ositelu ECE 5030 Final Presentation Tuesday, 15 December 1:00pm

Similar documents
Electromagnetic Interference between External Defibrillator and Cardiac Resynchronization Therapy-Pacemaker (CRT-P) Devices

Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

that physicians image Riata and Riata ST leads implanted in patients to assess for externalization or other visible insulation abnormalities.

MEDICAL POLICY Cardiac Event Monitors/ Cardiac Event Detection

OLBI Stimulation in Biatrial Pacing? A Comparison of Acute Pacing and Sensing Conditions for Split Bipolar and Dual Cathodal Unipolar Configurations

SARASOTA MEMORIAL HOSPITAL

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

Patient Safety: the optimal lead body design

Intermittent episodes of paced tachycardia: what is the cause?

Pacing Lead Implant Testing. Document Identifier

Electronic System for Measuring and Optimization of Pacemaker Pulses

Contents. Example: Pacemaker in DDD Mode. I. Introduction II. Website and Relevant Documents III. Background Information IV.

Wide QRS Tachycardia in a Dual Chamber Pacemaker Patient: What is the Mechanism?

Clinical Data Summary: Avoid FFS Study

Biomedical Instrumentation

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Sinus rhythm with premature atrial beats 2 and 6 (see Lead II).

Leadless Pacing. Osama Diab Assistant Prof. of Cardiology Ain Shams University Egypt

Long Term Monitoring of the Intrinsic Ventricular Monophasic Action Potential with an Implantable DDD Pacemaker

Does Changing the Pacing Configuration Affect Phrenic Stimulation? - A substudy of the DETECT PS Trial -

Is This Thing Working?

OHTAC Recommendation: Internet- Based Device-Assisted Remote Monitoring of Cardiovascular Implantable Electronic Devices

Implantable cardioverter defibrillator, Inappropriate shock, Lead failure

Supplemental Material

Therapeutic/Prosthetic Devices Pacemakers & Defibrillators. Biomedical Instrumentation JHU Applied Physics Lab. Dr. Nitish V. Thakor.

VALLIAMMAI ENGINEERING COLLEGE

DEFIBRILLATORS ATRIAL AND VENTRICULAR FIBRILLATION

Electrocardiography for Healthcare Professionals

Pediatric pacemakers & ICDs:

Syllabus and Program of the Diploma in Cardiac Pacing

December D. EL ALLAF Centre Hospitalier Hutois, Huy, Belgium. P. ATTUEL Centre Chirurgical Val d'or, Saint Cloud, France

LATITUDE Patient Management System

Interactive Simulator for Evaluating the Detection Algorithms of Implantable Defibrillators

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

Cardiac Rhythm Management Coder 2018

Ventricular Capture Control and the Increase of Pacemaker Lifetime

Friedman, Rott, Wokhlu, Asirvatham, Hayes 201. Figure 65.7 Shortening of the AV interval during pacing.

856 Unintentional Deactivation of ICDs Mayo Clin Proc, August 2002, Vol 77 Figure 1. Case 3. Printout from Guidant programmer (Guidant Corp, St Paul,

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

BRITISH HEART RHYTHM SOCIETY GUIDELINES FOR THE MANAGEMENT OF PATIENTS WITH CARDIAC IMPLANTABLE ELECTRONIC DEVICES (CIEDs) AROUND THE TIME OF SURGERY

A Mechanism for "False" Inhibition of Demand Pacemakers

EC6001 MEDICAL ELECTRONICS

Relation between QT interval and heart rate

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev

PRODUCT PERFORMANCE REPORT

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers

Leadless pacing: Technical challenges and concerns. Panos Vardas President Elect of the ESC, Prof. of Cardiology, Heraklion University Hospital

Model 5392 EPG Temporary Pacer

ICD: Basics, Programming and Trouble-shooting

Advances in Arrhythmia and Electrophysiology

Review of Pacemakers and ICD Therapy: Overview and Patient Management

Implantable Defibrillators Market by Product Type [Transvenous Implantable Cardioverter-Defibrillator (T-ICDs), Subcutaneous Implantable Cardioverter

Concurrent Failure of Active and Redundant Ventricular Epicardial Electrodes in Children

Programming of Bradycardic Parameters. C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany

Riata lead extraction- a single centre experience

Diagnostic capabilities of the implantable therapeutic systems

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing

11/21/18. EKG Pop Quiz. Michael Giocondo, MD Cardiac Electrophysiology Saint Luke s Cardiovascular Consultants

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

Implant manual. Dual-chamber pacemaker

MRI conditional devices. A luxury or a real clinical need? Sophie Mavrogeni, MD, FESC Onassis Cardiac Surgery Center, Athens, Greece

Closed Loop Stimulation vs. Conventional DDDR Pacing: Benefits of Hemodynamic Pacing

Closed Loop Stimulation: A New Philosophy of Pacing

STUDY REPORT ON THE EFFECT OF RADIO WAVES ON MEDICAL DEVICES

Implantable Cardioverter-Defibril. Defibrillators. Ratko Magjarević

Safety of Bioelectrical Impedance Analysis in Patients Equipped With Implantable Cardioverter Defibrillators

Defibrillator. BiomedGuy

WHAT CAN I DO ABOUT ATRIAL FIBRILLATION? Finding answers about atrial fibrillation

Cardiac Rhythm Management Coder 2017

Device Interrogation- Pacemakers, ICD and Loop Recorders. Dulce Obias-Manno, RN, MHSA, CCDS,CEPS, FHRS Device Clinic Coordinator, MHVI

2009 CPT Codes for Cardiac Device Monitoring

Timing cycles. Objectives Upon completion of this program the participant will be able to:

MRI and CIEDs. Disclosures

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

Leadless pacing. P.E. Vardas Professor of Cardiology University of Crete, Greece

Performance of a Miniaturized Transcatheter Pacing System: First-in-human experience

MEDICAL POLICY Cardioverter Defibrillators

ELEC ENG 4BD4 Lecture 1. Biomedical Instrumentation Instructor: Dr. Hubert de Bruin

Influence of Postural Position, Respiratory Maneuvers and Exercise on Atrial Electrograms

Clinically Relevant Basics of Pacing and Defibrillation

Principles and Applications of Electrical Circuits and Signal Theories in EP

Management of RT patients with implanted cardiac devices: From recommendation to implementation

Full file at

Device based CRT optimization: is there a future? Lessons learned from published trials

The Evolution of Pacemakers: An Electronics Perspective

Implantable Cardioverter Defibrillator with Wireless Charging and IOT Applications

A System for Pacemaker Treatment Advice 1

BIO 360: Vertebrate Physiology Performing and analyzing an EKG Lab 11: Performing and analyzing an EKG Lab report due April 17 th

Teaching Rounds in Cardiac Electrophysiology

Remote monotoring of cardiac rhythm devices: present and future Pacemaker and ICD

MEET MICRA. Micra TM ACTUAL SIZE. Transcatheter Pacing System

WHY AM I FAINTING? Finding answers about unexplained fainting

MEET MICRA. Micra TM ACTUAL SIZE. Transcatheter Pacing System

How to Record & Send Information

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

Presented By: Barbara Furry, RN-BC, MS, CCRN, FAHA Director The Center of Excellence in Education Director of HERO

Acute Evaluation of the Post Atrial Stimulation Evoked Response at Various Sites

Transcription:

Pacing the Heart Ayo Ositelu ECE 5030 Final Presentation Tuesday, 15 December 2009 @ 1:00pm

Outline Background Main Features New Features

The Cardiac Action Potential Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 7.

Natural Pacemakers of the Heart Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 8.

Two Schools of Thought Current density theory The critical factor required to induce a regenerative wave front of depolarization is the magnitude of current flowing through a given mass of myocardium Electric Field Theory The critical factor affecting myocardial depolarization is the magnitude of the electric field that is induced in the myocardium

History Hyman s Pacemaker of 1932 Accompanying Flow Diagram http://www.hrsonline.org/news/ep-history/topics-in-depth/hymanspacemaker2.cfm

Components Pacemaker Leads Pulse Generator Power Source (not discussed)

Pacemaker Leads The leads are the only link between the sophisticated electronics in the pulse generator and the heart. Relevant Issues: Polarization, electrode porosity, electrode composition, the electrode-tissue interface, etc. http://www.hrsonline.org/news/ep... Clinical Cardiac Pacing, pg 70.

Pacemaker Leads Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 74, 75.

Pacemaker Leads Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 86.

Pulse Generator Pacing therapy controller Output amplifiers Sense amplifiers Diagnostic subsystem

Pulse Generator Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 113, 114.

New Features Sensing Telemetry Improved SNR

Rate-Adaptive Sensors Activity-Sensing Rate-Adaptive Sensors Rate-Modulated Pacing Controlled by Mixed Venous Oxygen Saturation Temperature-Controlled Rate-Adaptive Pacing Rate-Adaptive Pacing Controlled by Dynamic Right Ventricular Pressure (dp/dtmax) Rate-Adaptive Pacing Based on Impedance- Derived Minute Ventilation, etc.

Rate-Adaptive Sensors Kristensson, et al.

Activity-Sensing Sensors Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 168, 169.

Activity-Sensing Sensors Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 171.

Activity-Sensing Sensors Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 171.

Activity-Sensing Sensors Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 171.

Rate-Adaptive Venous Oxygen Sensor Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 188.

Rate-Adaptive Venous Oxygen Sensor Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 192.

Rate-Adaptive Venous Oxygen Sensor Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 192.

Temperature-Controlled Sensor Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 202.

Temperature-Controlled Sensor Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 203.

Temperature-Controlled Sensor Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 203.

Temperature-Controlled Sensor Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 206.

Temperature-Controlled Sensor Fearnot, et al.

Manufacturer Overview Biotec, S.P.A., Bologna, Italy Biotronik, GmbH & Co., Berlin, Germany Cardiac Pacemakers Inc., St. Paul, MN Cook Pacemakers Corporation, Leechburg, PA Ela Medical, Rougermont, France Intermedics Inc., Angleton, TX Medtronic Inc., Minneapolis, MN

Manufacturer Overview Siemens Ltd., Solna, Sweden Sorin Biomedica, Saluggia, Italy St. Jude Medical, Inc, St. Paul, MN Telectronics Pacing Systems, Englewwod, CO Vitatron Medical B.V., Dieren, The Netherlands.

Manufacturer Overview Ellenbogen, Kay, and Wilkoff. Clinical Cardiac Pacing, pg 144.

Telemetry Telemetry involves the transmission of information from the pulse generator to an external programmer. Battery voltage and impedance, stimulus Battery voltage and impedance, stimulus current, voltage, and energy, lead resistance, intracardiac electrograms, and stored histograms of pace and sensed data retrievable from telemetry

Telemetry Biotronik Home Monitoring Medtronic CareLink Network Monitoring Device

Improving SNR Federica Censi, et al. studying the effects of electromagnetic interference on pacemakers. RF feedthrough filters

References Ellenbogen KA, Kay GN, Wilkoff BL. Clincial Cardiac Pacing. W.B. Saunders Company. Philadelphia. 2005. pg 3 276. Fearnot, NE et al. Heart Rate Correlation, response time, and effect of previous exercise using advanced pacing rate algorithm for temperature-based rate modulation. PACE (11): 1846-1852, 1988. Kristensson B, et al. Holter-monitored heart rhythm during atrioventricular synchronous and fixed-rate Ventricular pacing. PACE (9): 511, 1986. Censi, F, et al. Interference between mobile phones and pacemakers: a look inside. Ann Ist Super Sanita, 2007. Vol. 43, 3: 254 259. Hayes, DL and Vliestra RE. Pacemaker Malfunction. Ann Internal Medicine. 1993; 119: 828 835.