Reiterative ventricular fibrillation caused by R-on-T during temporary epicardial pacing: a case report

Similar documents
Permanent Pacemaker Implantation Post Cardiac Surgery: A Cautionary Tale

Figure 2. Normal ECG tracing. Table 1.

Temporary pacemaker 삼성서울병원 심장혈관센터심장검사실 박정왜 RN, CCDS

Intraoperative and Postoperative Arrhythmias: Diagnosis and Treatment

Cardiovascular Nursing Practice: A Comprehensive Resource Manual and Study Guide for Clinical Nurses 2 nd Edition

University of Florida Department of Surgery. CardioThoracic Surgery VA Learning Objectives

EKG Competency for Agency

RN-BC, MS, CCRN, FAHA

Presented By: Barbara Furry, RN-BC, MS, CCRN, FAHA Director The Center of Excellence in Education Director of HERO

Cardiac Cycle. Each heartbeat is called a cardiac cycle. First the two atria contract at the same time.

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

CRC 431 ECG Basics. Bill Pruitt, MBA, RRT, CPFT, AE-C

Electrocardiography for Healthcare Professionals

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

THE CARDIOVASCULAR SYSTEM. Heart 2

REtrive. REpeat. RElearn Design by. Test-Enhanced Learning based ECG practice E-book

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

Electrical Conduction

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

Pacing Codes and Modes Concepts

Please check your answers with correct statements in answer pages after the ECG cases.

Pediatric pacemakers & ICDs:

UNDERSTANDING YOUR ECG: A REVIEW

Electrocardiography Abnormalities (Arrhythmias) 7. Faisal I. Mohammed, MD, PhD

Arrhythmic Complications of MI. Teferi Mitiku, MD Assistant Clinical Professor of Medicine University of California Irvine

4. The two inferior chambers of the heart are known as the atria. the superior and inferior vena cava, which empty into the left atrium.

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

Clinical Policy: Holter Monitors Reference Number: CP.MP.113

Aortic Dissection Causes of Death

Cardiology. Objectives. Chapter

Electrocardiography Biomedical Engineering Kaj-Åge Henneberg

PATIENT WITH ARRHYTHMIA IN DENTIST S OFFICE. Małgorzata Kurpesa, MD., PhD. Chair&Department of Cardiology

BUSINESS. Articles? Grades Midterm Review session

Cardiovascular System Notes: Heart Disease & Disorders

Project Title Temporary Pacemaker Training Simulator

Cardiac Arrhythmias. Cathy Percival, RN, FALU, FLMI VP, Medical Director AIG Life and Retirement Company

Chapter 20 (2) The Heart

Emergency Intraoperative Echocardiography

Cardiac arrhythmias. Janusz Witowski. Department of Pathophysiology Poznan University of Medical Sciences. J. Witowski

When to implant an ICD in systemic right ventricle?

The Electrocardiogram part II. Dr. Adelina Vlad, MD PhD

Intra-operative Echocardiography: When to Go Back on Pump

Clinical and Electrocardiographic Characteristics of Patients with Brugada Syndrome: Report of Five Cases of Documented Ventricular Fibrillation

Skin supplied by T1-4 (medial upper arm and neck) T5-9- epigastrium Visceral afferents from skin and heart are the same dorsal root ganglio

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

An Approach to the Patient with Syncope. Guy Amit MD, MPH Soroka University Medical Center Beer-Sheva

(Ann Thorac Surg 2008;85:845 53)

Implantation of a Permanent Tined Endocardial Electrode into Right Atrium during Open-heart Surgery: Report of 3 Cases

SUPPLEMENTAL MATERIAL

Paroxysmal Supraventricular Tachycardia PSVT.

Temporary pacemaker : Programming &Trouble shooting

Cardiac rhythm detailed monitoring by an implanted pacemaker: The iecg solution

Matters of the Heart: Comprehensive Cardiology SARAH BEANLANDS RN BSCN MSC

ECG ABNORMALITIES D R. T AM A R A AL Q U D AH

Do Now. Get out work from last class to be checked

National Coverage Determination (NCD) for Cardiac Pacemakers (20.8)

Cardiology/Cardiothoracic

ECG Interpretation Made Easy

Title and contents page 1 Who should read this document 2 Scope of the Guideline 2 Background 2 What is new in this version 2

BEDSIDE ECG INTERPRETATION

ECG interpretation basics

Review Packet EKG Competency This packet is a review of the information you will need to know for the proctored EKG competency test.

Principles of Biomedical Systems & Devices. Lecture 8: Cardiovascular Dynamics Dr. Maria Tahamont

Cardiac Pacing. Learning outcomes. Introduction. The cardiac impulse - its formation and its failure CHAPTER. To understand:

Diploma in Electrocardiography

Chapter 16: Arrhythmias and Conduction Disturbances

The Cardiovascular System. Chapter 15. Cardiovascular System FYI. Cardiology Closed systemof the heart & blood vessels. Functions

Cardiovascular Physiology. Heart Physiology. Introduction. The heart. Electrophysiology of the heart

11/21/18. EKG Pop Quiz. Michael Giocondo, MD Cardiac Electrophysiology Saint Luke s Cardiovascular Consultants

Basic Dysrhythmia Interpretation

SARASOTA MEMORIAL HOSPITAL

Implantable Cardioverter-Defibril. Defibrillators. Ratko Magjarević

ECG Interpretation Cat Williams, DVM DACVIM (Cardiology)

12-Lead ECG Interpretation. Kathy Kuznar, RN, ANP

Lab 16. The Cardiovascular System Heart and Blood Vessels. Laboratory Objectives

Ablative Therapy for Ventricular Tachycardia

Arrhythmia 341. Ahmad Hersi Professor of Cardiology KSU

Chapter 9. Learning Objectives. Learning Objectives 9/11/2012. Cardiac Arrhythmias. Define electrical therapy

EHRA Accreditation Exam - Sample MCQs Invasive cardiac electrophysiology

Introduction. Study Design. Background. Operative Procedure-I

CIRCULATION. Cardiovascular & lymphatic systems Functions. Transport Defense / immunity Homeostasis

UNDERSTANDING ELECTROPHYSIOLOGY STUDIES

Cardiac Telemetry Self Study: Part One Cardiovascular Review 2017 THINGS TO REMEMBER

Step by step approach to EKG rhythm interpretation:

Electrocardiography for Healthcare Professionals

Adult Echocardiography Examination Content Outline

Circulatory System Notes

The Heart and Heart Disease

DEFIBRILLATORS ATRIAL AND VENTRICULAR FIBRILLATION

12 Lead ECG Interpretation

Index. Note: Page numbers of article titles are in boldface type.

Lecture outline. Electrical properties of the heart. Automaticity. Excitability. Refractoriness. The ABCs of ECGs Back to Basics Part I

Revisions to the BC Guide for Physicians in Determining Fitness to Drive a Motor Vehicle

Chapter 20: Cardiovascular System: The Heart

Arrhythmias and congenital heart disease

Chad Morsch B.S., ACSM CEP

ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ

CORONARY ARTERIES. LAD Anterior wall of the left vent Lateral wall of left vent Anterior 2/3 of interventricluar septum R & L bundle branches

Unit 6: Circulatory System. 6.2 Heart

Wolff-Parkinson-White Syndrome

Transcription:

Nakamori et al. JA Clinical Reports (2016) 2:3 DOI 10.1186/s40981-016-0029-6 CASE REPORT Reiterative ventricular fibrillation caused by R-on-T during temporary epicardial pacing: a case report Yuki Nakamori *, Takuma Maeda and Yoshihiko Ohnishi Open Access Abstract Epicardial pacemaker wire insertion is standard following cardiothoracic surgery. However, undersensing of pacing wires may cause the R-on-T phenomenon, which induces ventricular fibrillation. We report a case of a male patient with severe mitral regurgitation scheduled for mitral valve replacement who experienced two ventricular fibrillation episodes related to the R-on-T phenomenon caused by undersensing of the epicardial pacing wire. Both undersensing events happened despite an appropriately low sensing threshold. Notably, the stimulated T wave followed the QRS of the premature ventricular contraction (PVC). This case suggests that a PVC s R wave may be undersensed despite a low sensing threshold. This critical complication may have occurred because pacemakers sense R waves using a slew rate, which is the quotient of voltage over time. As a result, pacemakers may undersense wide QRS waves such as PVCs. Avoiding this dangerous phenomenon completely is not possible using epicardial pacemakers; therefore we recommend carefully adapting epicardial pacing especially when PVC waves occur frequently. Keywords: Cardiac pacemaker, Artificial, Epicardial temporary pacing, R-on-T phenomenon, Undersensing, Slew rate, Premature ventricular contraction Background Epicardial pacemaker wire insertion is standard following cardiothoracic surgery in most centers [1]. These wires are valuable in diagnosing and treating cardiac arrhythmias following surgery, maintaining an appropriate heart rate, and may facilitate the reestablishment of circulatory integrity and normal hemodynamics [2]. They also suppress both atrial and ventricular tachyarrhythmias [3]. The R-on-T phenomenon is a well-known entity that predisposes to dangerous arrhythmias, including ventricular fibrillation (Vf), a fatal arrhythmia. The phenomenon is also related to undersensing of temporary pacing wires. To check its sensitivity, the pacemaker rate should be set below the endogenous rate (if present), and placed in ventricular demand (VVI), atrial demand (AAI), or atrioventricular universal (also known as dual-chamber (DDD)) modes. The sensitivity is increased until the sense indicator stops flashing and that number is the threshold. It is recommended to leave the * Correspondence: yunakamori@gmail.com Department of Anesthesiology, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, Suita, Osaka 565-8565, Japan pacing generator set at half the pacing threshold. If there is no endogenous rhythm, it is impossible to determine the pacemaker sensitivity, in which case the sensitivity is typically set to 2 mv [4]. There is currently no consensus on the threshold for premature ventricular contraction (PVC). Previous reports have presented electrocardiography (ECG) in cases of undersensing in temporary pacing wires [1, 5]; however, the cause is unclear. The R-on-T pacing because of undersensing of temporary pacing wires is an unavoidable and critical problem for most patients undergoing surgery using cardio-pulmonary bypass (CPB). Anesthesiologists must understand the mechanism of undersensing to provide better pacemaker management for patients undergoing cardiac surgery using CPB to protect their safety. We herein report two Vf episodes in a single patient related to the R-on-T phenomenon caused by undersensing of the pacing wire. In this case, undersensing occurred despite a sufficiently low threshold, on which the T wave followed the QRS of the PVC, which is an 2016 Nakamori et al. Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Nakamori et al. JA Clinical Reports (2016) 2:3 Page 2 of 6 important finding for anesthesiologists who manage epicardial pacemakers. Case presentation A 65-year-old male with severe mitral regurgitation and moderate tricuspid regurgitation was scheduled for mitral valve replacement, tricuspid annuloplasty, and maze surgery. The degree of heart failure was New York Heart Association class II and atrial fibrillation had been present for 18 months. There was no history of syncope or sudden death among the patient s family members. Preoperative coronary angiography showed no significant stenosis; preoperative ECG revealed a heart rate of 65 bpm and atrial fibrillation. The QRS was narrow without evidence of bundle branch block, and there was no sign of QT prolongation. General anesthesia was induced with midazolam, fentanyl, and rocuronium and maintained by continuous injection of propofol, remifentanil, and rocuronium. The operation proceeded without problems and his mitral valve was replaced with a biological valve. The left atrium vent and aortic root cannula were removed after using transesophageal echocardiography (TEE) to confirm that the intracardiac air had been completely removed. We then attempted to withdraw from CPB and began VVI pacing at 50 bpm (Fig. 1). The CPB time was 185 min and the cardiac arrest time was 155 min. After 30 min, we attempted atrial asynchronous (AOO) pacing, but the patient s atrioventricular (AV) node did not completely conduct supraventricular electrical activity and the ECG showed Mobitz type AV block (Fig. 2); therefore, we elected to maintain VVI pacing. Before sternal closure, epicardial pacemaker wires were inserted on the anterior right ventricle (RV) and the anterior right atrium and we changed the direct grasping myocardial lead to epicardial pacemaker wires. Because the patient s endogenous ventricular rhythm was only 30 bpm immediately post-operatively, we chose VVI pacing at 90 bpm. At that time, both the electrolyte levels and acid base balance were within the allowable ranges; Na, 143 meq/l; K, 4.4 meq/l; Cl, 116 meq/l; and standard base excess, 3.1 mmol/l. Additionally, the patient s rectal temperature was kept above 36.2 C after weaning from CPB. During transfer from the operation room to the intensive care unit (ICU), the ECG showed Vf (Fig. 3). External defibrillation with 270 J was administered immediately, which resulted in recovery of the electrical rhythm; ventricular pacing was then able to capture ventricular contraction. We assumed that undersensing had occurred; therefore, the ventricular sensing threshold was changed from 10 mv to 2 mv, which is a sufficiently low sense threshold, recommended in cases where there is no endogenous rhythm [4]. However, within only two minutes of the first Vf, the ECG again showed a Vf waveform (Fig. 4). The second Vf was also treated by external defibrillation. After these two Vf episodes, we performed blood gas analysis and again Fig. 1 ECG and pressure waveform at 50 bpm VVI pacing. Each VVI pacing spike captures a QRS wave

Nakamori et al. JA Clinical Reports (2016) 2:3 Page 3 of 6 Fig. 2 ECG and pressure waveform showing Mobitz type AV block. Each AOO pacing spike captures a P wave, but every third P wave does not induce a QRS wave Fig. 3 ECG and pressure waveform during the first episode of ventricular fibrillation. This ECG shows the R-on-T phenomenon resulting from undersensing of a PVC. A pacing spike hit the T wave (large arrow) following a PVC (small arrow)

Nakamori et al. JA Clinical Reports (2016) 2:3 Page 4 of 6 Fig. 4 ECG and pressure waveform during the second episode of ventricular fibrillation. This ECG also shows the R-on-T phenomenon resulting from undersensing of a PVC. A pacing spike hit the T wave (large arrow) following a PVC (small arrow) in this episode, as well obtained values within the allowable ranges: Na, 144 meq/l; K, 4.6 meq/l; Cl, 117 meq/l; and standard base excess, 3.8 mmol/l. We subsequently evaluated the electronically recorded ECG waveforms collected during anesthesia and found that the Vf episodes were induced by the R-on-T pacing. Neither T wave during the Vf episodes followed the pacing-induced QRS complex, but instead followed the T wave of the premature ventricular contractions. To prevent further the R-on-T pacing, the pacemaker was set at AOO pacing at 70 bpm during the ICU stay. Because of the presence of the AV block, AOO pacing could not produce enough subsequent ventricular contraction; therefore, we used norepinephrine to maintain the body pressure at first. However, the patient s AV conduction recovered over time, and he was free from temporary epicardial pacing and any catecholamines or vasopressors support on postoperative day 1. He was discharged from the ICU on postoperative day 5 and finally discharged from the hospital without any neurological sequelae on postoperative day 13. Discussion This was a case of the R-on-T phenomenon caused by undersensing of the pacing wire in a single patient. Notably, the T wave followed the QRS of the PVC. Understanding this phenomenon requires the answers to two questions: First, why were the pacing spikes not inhibited? Second, what caused the PVCs? The R-on-T pacing in this patient occurred despite lowering the sense threshold to 2 mv, suggesting that simple undersensing is unlikely to explain this phenomenon. Lowering the sense threshold even further than in this case is not a reasonable management in temporary epicardial pacing for patients with prolonged AV delay. Like this patient, severe AV block cases require ventricular pacing to maintain sufficient cardiac output because their ventricular contractions are too rare to do so; therefore excessively low sensing thresholds are not an option. Low threshold sensing numbers cause the pacemaker to sense external factors such as electrical scalpel stimulation or postural change. If pacing is excessively inhibited, patients suffer critical bradycardia and low-output syndrome. Dispersion of the duration of the action potential and electrical inhomogeneity in the myocardium may explain the undersensing [6]. The electrical voltage waveforms that pacemakers detect are not equal to those identified by surface electrocardiography. Surface electrocardiography reflects electrical activity of the entire heart while the pacemaker electrode contacts the external cardiac muscle directly and senses only the electrical excitation of surrounding cells. Surface electrocardiography is related to space and epicardial wires are related to linear or punctual factors. With peri-lead fibrous or necrotic tissue, pacemakers cannot detect depolarization despite

Nakamori et al. JA Clinical Reports (2016) 2:3 Page 5 of 6 QRS waves appearing on the ECG monitor. Also, the literature provides little information on the best locations for epicardial pacing. In the presented case, the temporary epicardial electrode was placed on the anterior RV, which is the most widely used location for wire implantation because of the easy access. However, one study reported that the anterior RV location provides suboptimal sensing and stimulation thresholds [7]. In the presented case, the undersensed QRS wave was a wide PVC; therefore, QRS width could be a contributing factor. If the device recognizes the R wave by slew rate, which is the quotient of voltage over time, a wide QRS may impair accurate sensing of R voltage. The duration of the QRS wave would be longer and the slew rate would be smaller despite having the same R wave voltage. Therefore, temporary epicardial pacing devices set at a clinically valid threshold may not detect abnormally wide QRS waves without omission. We provided anesthetic management to prevent arrhythmias in this patient. We maintained intravascular volume, preload, afterload, heart rate, and contractile force within normal limits by referring to TEE, arterial blood pressure, pulmonary arterial pressure, central venous pressure, cardiac output, and mixed venous blood saturation in oxygen by Swan-Ganz Catheter. We did not use excessive amounts of catecholamines and only 3 mcg/kg/min dopamine was injected. We also maintained the patient s electrolytes and body temperature at normal levels. The ECG ST slope elevated slowly by the time of sternal closure. TEE performed after the two Vf episodes showed poor contraction of the right coronary artery (RCA) perfusion segments, often caused by RCA ischemia. Intracardiac air was removed carefully and there was little probability that coronary spasm or partial pericardial tamponade occurred. Bleeding in or around the epicardial pacing wires tends to occur in the immediate postoperative period and pericardial hematoma formation around epicardial pacing wires has been reported [8]. Myocardial infarction related to the epicardial pacing wire itself has also been reported [9]. The hypothesis that ischemic RCA perfusion induced frequent PVCs is reasonable. Following this case, we reviewed our anesthetic records from the past 7 years and found one case of Vf resulting from the R-on-T wave phenomenon; however, we concluded that the cause of the R-on-T in that case was an excessively high sensing threshold. Also, the undersensed QRS wave was one following a P wave. This case was our first experience of Vf caused by R on PVC T wave phenomenon. Some authors suggest that routine use of temporary epicardial pacing wires after valve surgery is only necessary for high risk patients [10, 11]. In addition to the R-on-T pacing, major complications of epicardial wires include infection, myocardial damage, perforation, tamponade, and disruption of coronary anastomoses [4]. Insertion can prolong the operative time and increase the risk of bleeding and patients are also at risk for ventricular arrhythmias during removal of epicardial pacing wires [12]. Therefore, it is important to consider the risks of using temporary epicardial pacing. Conclusions We report a case of Vf episodes related to the R-on-T phenomenon caused by undersensing of a QRS wave despite an appropriately low sensing threshold. Temporary epicardial pacing is very effective for bradycardia or low output syndrome after CPB but there are instances in which a PVC s R wave may be undersensed despite an appropriately low sensing threshold. This undersensing can cause the R-on-T phenomenon, which may induce critical arrhythmia. It is very important to assess the use of temporary epicardial pacing with high-frequency PVC waves. Consent Written informed consent was obtained from the patient for publication of this Case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal. Abbreviations AAI: atrial demand; AOO: atrial asynchronous; AV: atrioventricular; CPB: cardio-pulmonary bypass; DDD: dual-chamber; ECG: electrocardiography; ICU: intensive care unit; PVC: premature ventricular contraction; RCA: right coronary artery; RV: right ventricle; TEE: transesophageal echocardiography; Vf: ventricular fibrillation; VVI: ventricular demand. Competing interests The authors declare that they have no competing interests. Authors contributions YN wrote the manuscript. TM collected the data. YO collected the data and analyzed the electrocardiograms. All authors read and approved the final manuscript. Authors information YN: Resident doctor in the Department of Anesthesiology, National Cerebral and Cardiovascular Center; TM: Staff doctor in the Department of Anesthesiology, National Cerebral and Cardiovascular Center; YO: Chief doctor in the Department of Anesthesiology, National Cerebral and Cardiovascular Center. Received: 5 November 2015 Accepted: 5 January 2016 References 1. Chemello D, Subramanian A, Kumaraswamy N. Cardiac arrest caused by undersensing of a temporary epicardial pacemaker. Can J Cardiol. 2010;26: e13 4. 2. Del Nido P, Goldman BS. Temporary epicardial pacing after open heart surgery: complications and prevention. J Card Surg. 1989;4:99 103. 3. Archbold RA, Schilling RJ. Atrial pacing for the prevention of atrial fibrillation after coronary artery bypass graft surgery: a review of the literature. Heart. 2004;90:129 33.

Nakamori et al. JA Clinical Reports (2016) 2:3 Page 6 of 6 4. Reade MC. Temporary epicardial pacing after cardiac surgery: a practical review: part 1: general considerations in the management of epicardial pacing. Anaesthesia. 2007;62:264 71. 5. Ren X, Hongo RH. Polymorphic ventricular tachycardia from R-on-T pacing. J Am Coll Cardiol. 2009;53:218. 6. Oupadia P, Ramaswamy K. Images in clinical medicine. R-on-T phenomenon. N Engl J Med. 1998;338:1812. 7. Hurle A, Gomez-Plana J, Sanchez J, Martinez JG, Meseguer J, Llamas P. Optimal location for temporary epicardial pacing leads following open heart surgery. Pacing Clin Electrophysiol. 2002;25:1049 52. 8. Kapoor A, Syal S, Gupta N, Gupta A. Right paracardiac mass due to organized pericardial hematoma around retained epicardial pacing wires following aortic valve replacement. Interact Cardiovasc Thorac Surg. 2011; 13:104 6. 9. Cohen SB, Bartz PJ, Earing MG, Sheil A, Nicolosi A, Woods RK. Myocardial infarction due to a retained epicardial pacing wire. Ann Thorac Surg. 2012; 94:1724 6. 10. Alwaqfi NR, Ibrahim KS, Khader YS, Baker AA. Predictors of temporary epicardial pacing wires use after valve surgery. J Cardiothorac Surg. 2014;9:33. 11. Ferrari AD, Sussenbach CP, Guaragna JC, Piccoli Jda C, Gazzoni GF, Ferreira DK, et al. Atrioventricular block in the postoperative period of heart valve surgery: incidence, risk factors and hospital evolution. Rev Bras Cir Cardiovasc. 2011;26:364 72. 12. Carroll KC, Reeves LM, Andersen G, Ray FM, Clopton PL, Shively M, et al. Risks associated with removal of ventricular epicardial pacing wires after cardiac surgery. Am J Crit Care. 1998;7:444 9. Submit your manuscript to a journal and benefit from: 7 Convenient online submission 7 Rigorous peer review 7 Immediate publication on acceptance 7 Open access: articles freely available online 7 High visibility within the field 7 Retaining the copyright to your article Submit your next manuscript at 7 springeropen.com