G7 ACETABULAR SYSTEM. beautifully. efficient.

Similar documents
Arcos Modular Femoral Revision System

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Understanding Hip Implant Options

Vanguard. Total Knee System

Optimum implant geometry

Comprehensive Reverse Shoulder System

Optimum implant geometry

Featuring. Technology. Product Rationale

PINNACLE REVISION CUP SYSTEM

FLH /11

THE PERSONALIZED KNEE

JuggerKnot Soft Anchor 1.0 mm Mini

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

The information contained in this document is intended for healthcare professionals only.

Peanut Growth Control Plating System

DVR Crosslock Distal Radius Plating System. Product Brochure

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

Bone Preservation Stem

The information contained in this document is intended for healthcare professionals only.

Tibial Fixation. with TunneLoc Device. Surgical Technique by Mark J. Albritton, M.D. and Sherwin Ho, M.D.

StageOne. Shoulder Cement Spacer Molds. Surgical Technique

Scan Bi-Polar 22/28. Operative Technique

D E S I G N R A T I O N A L E

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

The Leader in Orthopaedic Innovation

3.0 mm Cannulated Screw System. Surgical Technique

Signature Personalized Patient Care

OSS Modular Arthrodesis System. Assembly Guide

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

Biomet Multi-Axial Correction (MAC) System Correction Atlas

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Acetabular Cup System. Clinical Summary

MARATHON Cross-Linked Polyethylene

JuggerKnot Soft Anchor 1.0 mm Mini

MetaFix Cementless Total Hip Replacement Product overview

*smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System. Product Information

ReCap Product Rationale

ACETABULAR CUP SURGICAL TECHNIQUE

Active Articulation E1

PINNACLE Acetabular Cup System

DEVELOPED BY SURGEONS

Optimum implant geometry

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Systematic Review of Clinical Outcome using Titanium Fiber Mesh Porous Ingrowth Surfaces

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Reaching new heights. Comprehensive. Efficient. Simple.

CoAxial Spray Kit. Simplifying the Application of Platelet-Rich Plasma onto Graft Material. Surgical Technique

HIP CONTINUUM OF CARE. Trauma and Joint Reconstruction Hip Portfolio

Common Instruments for Biomet Hip Systems

Taperloc Complete Hip System. Surgical Technique

Instrumentation Options

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

SUMMIT and DURALOC. Clinical Summary

CERAMIC-ON-METAL. References: Cat No: version 2

Dual Mobility System Surgical technique

Dual Mobility System Evaluation surgical technique

DermaSpan Acellular Dermal Matrix. Reinforcement of Ruptured Posterior Tibial Tendon Repair. Surgical Protocol by Charles Zelen, DPM, FACFAS

SternaLock Blu PRIMARY CLOSURE SYSTEM

RECLAIM REVISION HIP SYSTEM

HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX

Versatility in a proven design. Trilogy Acetabular System

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

Vault Reconstruction System. Meet Your Match

Gender Solutions Patello-Femoral Joint System

RM Philosophy Innovation based on clinical evidence.

Duraloc CONSTRAINED LINER

Femoral Fixation for ACL Reconstruction. Surgical Protocol by Mark Gittins, D.O.

Longevity Offset and Oblique Liners. Surgical Technique

Oxford. Partial Knee

Trusted technology. Trusted performance. Supporting healthcare professionals

Avenir Femoral Hip System

JuggerKnot Soft Anchor 1.4/1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff SLAP Repair

Stability without compromise. Epsilon Durasul Constrained Insert

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

R3think your options. For US distribution only.

Product Rationale. Where Strength and Modularity Connect

The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series

Optimizing function Maximizing survivorship Accelerating recovery

StelKast Acetabular. Surgical Protocol and Product Specifications. Including ProForm, Provident, Provident Apical Threaded Hole & Systems

DUAL MOBILITY CUP, CEMENTED OR CEMENTLESS

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Amy Hendrickson Complaint/M DR Administrator DePuy Johnson & Johnson Phone: x 7179 Fax:

Hip Product Brochure

Restoration Modular Revision Hip System. Choice Matters

Allofit /Allofit -S Alloclassic Acetabular Cup System

PLR. Proximal Loading Revision Hip System

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

Trabecular Metal Acetabular Revision System Buttress and Shim Augments Surgical Technique

Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System

Positioning Sleeve Surgical Technique

Trinity. Advanced Bearing Acetabular System Surgical technique

RECOVERY. P r o t r u s i o

Arcos Modular Femoral Revision System. Broach and Calcar Proximal Bodies Surgical Technique

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

Trilogy Acetabular System

TOTAL HIP REPLACEMENT:

JOINT RECONSTRUCTION PORTFOLIO OVERVIEW

Transcription:

G7 ACETABULAR SYSTEM beautifully efficient.

HERITAGE MEETS MODERN DESIGN SIMPLICITY, EFFICIENCY AND PERFORMANCE The G7 System is a multi-bearing acetabular platform delivering simplicity, efficiency and performance to optimize the operating room experience. With the latest technological developments in implant and instrumentation design, it offers a wide range of acetabular shell options, clinically proven fixation, 1 4 and advanced bearing technologies within a simple, elegant and highly flexible instrumentation platform.

CLINICALLY PROVEN HERITAGE Biomet continues to expand upon its rich history of clinically successful acetabular products. The clinical experience with RingLoc and Exceed* acetabular systems, E1 Antioxidant Infused Technology and PPS coating has provided the foundation for the development of the G7 System. 98% survivorship at 15 years 5 - RingLoc Acetabular System 98% survivorship at 5 years 6 - Exceed ABT Acetabular System* 100% survivorship at 3 years 7,8 - E1 Antioxidant Infused Technology 99% survivorship at 3 years 9 - ArComXL Polyethylene 99% survivorship at 26 years 10 - PPS Porous Plasma Spray Coating *Not available for sale in the US. 01 02

ENGINEERED FOR ULTIMATE PERFORMANCE Patent Pending Color-Coded Shell corresponds with instrumentation and package labels to create an efficient and accurate OR environment* Optimized head to shell ratio facilitates the use of a 36 mm head in a 50 mm shell Multi-bearing Locking Mechanisms accommodate multiple polyethylene configuration options, including Freedom Constrained Liners, for a wide spectrum of acetabular reconstructive needs Push Out Strength 11 Lever Out Strength 11 550 650 Force ( lbf) 450 350 250 150 50 0 504 190 62% Lower 463 8% Lower 319 36% Lower Force (in-lbf) 450 350 250 150 50 0 442 446 Statistically equivalent 204 53% Lower 252 43% Lower Biomet G7 E1 (10 Mrad) DePuy Synthes Pinnacle AltrX (7.5 Mrad) Zimmer Continuum Longevity (10 Mrad) Stryker Trident X3 (10 Mrad) Biomet G7 E1 (10 Mrad) DePuy Synthes Pinnacle AltrX (7.5 Mrad) Zimmer Continuum Longevity (10 Mrad) Stryker Trident X3 (10 Mrad) Push Out: Axial force required to dislodge a polyethylene liner from an acetabular shell All tests were performed with 54 mm acetabular shells and 32 mm acetabular liners Lever Out: Disassembly force required to dislodge a polyethylene liner from an acetabular shell All tests were performed with 54 mm acetabular shells and 32 mm acetabular liners * Primary identification should be made using size and letter designations.

OSSEOTI POROUS METAL TECHNOLOGY INSPIRED BY BONE OsseoTi Porous Metal is created through the use of a proprietary additive manufacturing process, generating a porous material designed with a structure that directly mimics human cancellous bone. Clinically proven titanium (Ti6Al4V) material is used to build a fully integrated part with solid and porous regions while maintaining consistent porosity and strength to facilitate tissue ingrowth and implant stability. 12 When applied to the G7 system, this enables surgeons to realize the benefits of highly porous technology without compromising head to shell ratio. Unique porous architecture has demonstrated excellent integration with host bone as early as 4 weeks in an animal study 12* Porosity of approximately 70% directly mimics the structure of human cancellous bone Average pore size of 475 microns facilitates cell migration, vascularization and bone ingrowth 12* Material strength between that of cancellous and cortical bone enhances biological fixation and loading of surrounding bone 9 * Animal studies are not necessarily indicative of clinical performance. 03 04

ADVANCED TECHNOLOGY FOR INCREASED DEMANDS The G7 Acetabular System offers a wide range of bearing options, allowing each surgeon to choose what is right for each patient. POLYETHYLENE WEAR 9 5 million cycles on a hip simulator 55.0 50.0 *Gamma Sterilized Polyethylene 53.3 mm 3 45.0 40.0 Volumetric Wear (mm 3 /million Cycles) 35.0 30.0 25.0 20.0 15.0 10.0 5.0 12.89 10.04 0 3.36 2.82 CoCr on ArComXL BIOLOX delta on ArComXL CoCr on E1 BIOLOX delta on E1 *Gamma Sterilized polyethylene test performed with 28 mm bearings. April, 2007 All other tests were performed with 62 mm acetabular shells and 44 mm bearings. Sept., 2012

E1 ANTIOXIDANT INFUSED TECHNOLOGY The Protection of Vitamin E E1 is the only antioxidant infused bearing to use a proprietary diffusion process to maximize wear resistance, 9 strength and oxidative resistance. E1 FREEDOM CONSTRAINED LINER High Constraint, Optimal Range of Motion The Freedom Constrained liner offers both constraint and optimized range of motion. The pre-assembled constraining ring maximizes lever out force of the head and allows for easy assembly in-situ. 13,14 ARCOMXL HIGHLY CROSSLINKED POLYETHYLENE Low Wear, High Strength, Oxidative Stability Utilizing a patented radiation crosslinking and free radical processing method, ArComXL polyethylene offers low wear, high strength, and oxidative stability. 9 05 06

ORGANIZED FOR EFFICIENCY Shell Trial Streamlining total hip replacement goes beyond implant design and bearing options. Full optimization of implant and instrument delivery systems is required to improve flow and performance from implantation through sterile processing. The G7 platform introduces a number of instrumentation advancements coupled with Biomet s unique color-coding system in order to: Shell Packaging > Reduce the need for a large number of trays and instruments in the OR > Customize instrumentation based on patient anatomy or surgeon preference > Simplify implant and instrument selection during surgery Shell Implant Easy-to-Use Inserter Handles > Transmit tactile feedback during cup insertion > Provide maximum control with ergonomic, comfortably-sized silicone grips > Offer optimal overall handle balance to minimize effect on cup placement

Unique Patient-Specific Mini Tray System Reduces clutter in the operating room by allowing staff and surgeons to choose only the instrumentation needed Face Plate Impactor Liner Packaging Liner Trial 07 08

ADVANCING TOTAL HIP REPLACEMENT From simple primary to complex revision arthroplasty, Biomet offers a comprehensive portfolio of total hip constructs that combine rich clinical heritage with modern technological advancements. Each of these is designed to address the distinct needs of individual patients, while simplifying surgical workflow.

G7 SHELL PORTFOLIO G7 shells are available in limited and multi hole designs for use in both primary and revision total hip arthroplasty. Holes are clustered to allow for placement of screws in the strongest portion of pelvic bone. Screw holes are pre-plugged in limited hole shells to avoid the migration of polyethylene debris that could potentially cause osteolysis. The plugs can be removed if supplemental fixation is desired. PPS Limited Hole Acetabular Shell 42 68 mm (3 Hole, pre-plugged) OsseoTi Limited Hole Acetabular Shell 42 52 mm (3 Hole, pre-plugged) 54-68 mm (4 Hole, pre-plugged) OsseoTi Multi Hole Acetabular Shell 42 80 mm (number of holes increases as shell diameter increases; will not accept screw hole plugs) 09 10

References 1. Keisu, K., et al. Primary Cementless Total Hip Arthroplasty in Octogenarians: Two to Eleven-Year Follow- Up. Journal of Bone and Joint Surgery. 83: 359, 2001. 2. McLaughlin, J., et al. Total Hip Arthroplasty in Young Patients. 8 to 13 year Results Using an Uncemented Stem. Clinical Orthopaedics and Related Research. 373: 153 63, 2000. 3. Parvizi, J., et al. Prospective Matched-Pair Analysis of Hydroxyapatite-Coated and Uncoated Femoral Stems in Total Hip Arthroplasty. Journal of Bone and Joint Surgery. 83: 783 6, 2004. 4. McLaughlin, J., et al. Total Hip Arthroplasty with an Uncemented Femoral Component: Excellent Results at Ten Year Follow-Up. Journal of Bone and Joint Surgery. 79 (B): 900 7, 1997. 5. The Danish Hip Arthroplasty Register, 2011 Annual Report, confirms 15-year survivorship at 98.1% for the Ranawat-Burstein RingLoc cup design. 6. The April 2012 ODEP UK (Orthopaedic Device Evaluation Panel), based upon 9,529 patients, upgraded the Exceed ABT cementless cup from 3A to 5A classification, confirming 5-year survivorship of at least 95%. ODEP Notification from PASA, Mr. Phil Lewis PhD, Lead Senior Buyer, 30.04.12. 7. Greene, M., et al. Multicenter RSA Evaluation of In Vivo Wear of Vitamin E Stabilized Highly Cross-linked Polyethylene. 2012 AAOS Annual Meeting. 8. Greene, M., et al. Three Year RSA Evaluation of the Wear of Vitamin E Stabilized Highly Crosslinked Polyethylene, the Stability of Regenerex Acetabular Shells and Femoral Components with 32 mm Heads. AAOS, 2011. 9. Data on file at Biomet. Bench test results not necessarily indicative of clinical performance. 10. McLaughlin, J.R. and Lee, K.R. Survivorship at 22 to 26 Years Reported with Uncemented Tapered Total Hip Stem. Orthopedics Today. 30(1): 1, 2010. 11. Testing conducted by independent lab. Report data on file at Biomet. Laboratory testing August, 2013. Test results are not necessarily indicative of clinical performance. 12. Gupta, G. OsseoTi Porous Metal for Enhanced Bone Integration: an Animal Study. Biomet Form No. BMET0718.1-GBL. 13. Berend, K., et al. A Constrained Device with Increased Range of Motion Prevents Early Dislocation. Clinical Orthopedics and Related Research. 447: 70 5, 2006. 14. Tradonsky, S., et al. Performance Characteristics of Two Piece Acetabular Cups Series II. Scientific Exhibit. 62nd Annual AAOS Meeting. 1996. One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical care is to provide the right solution for each individual patient. This requires clinical mastery, a human connection between the surgeon and the patient, and the right tools for each situation. At Biomet, we strive to view our work through the eyes of one surgeon and one patient. We treat every solution we provide as if it s meant for a family member. Our approach to innovation creates real solutions that assist each surgeon in the delivery of durable personalized care to each patient, whether that solution requires a minimally invasive surgical technique, advanced biomaterials or a patient-matched implant. When one surgeon connects with one patient to provide personalized care, the promise of medicine is fulfilled. This publication and all content, is protected by copyright, trademarks and other intellectual property rights owned by or licensed to Biomet Inc. or its affiliates unless otherwise indicated. It must not be used, copied or reproduced in whole or in part without the express written consent of Biomet or its authorized representatives. BIOLOX delta is a trademark of CeramTec AG. This material is intended for healthcare professionals and the Biomet sales force. The distribution to any other recipient is prohibited. For product information see package insert and Biomet s website. Check for local product clearances and reference product specific instructions for use. Not for distribution in France 2015 Biomet Orthopedics Form No. BMET0327.1 REV0115 Legal Manufacturer Biomet Orthopedics P.O. Box 587 56 E. Bell Drive Warsaw, Indiana 46581-0587 USA www.biomet.com Biomet UK, Ltd. Waterton Industrial Estate Bridgend, South Wales CF31 3XA UK 0086 Note: For Ceramic components contained within this Surgical Technique Biomet UK, Ltd is the Legal Manufacturer.