NMIJ measurement service on ultrasonic field parameters available to demonstrate performance and safety of ultrasonic medical equipment

Similar documents
High ultrasonic power standard by calorimetric method in NMIJ. Takeyoshi Uchida Masahiro Yoshioka

The current status of Acoustics, Ultrasound and Vibration measurement standards at NMIJ/ AIST

Underwater Acoustic Measurements in Megahertz Frequency Range.

IEC 87: Ultrasonics Overview update July 2002

39th Annual UIA Symposium. Metrology research for External Beam Cancer Therapy. K.-V. Jenderka

The current status of Acoustics, Ultrasound and Vibration measurement standards at NMIJ/ AIST

KRISS MEASUREMENT TECHNIQUE OF ULTRASOUND EXPOSURE PARAMETERS AND PREPARATION OF ULTRASOUND POWER KEY COMPARISON IN APMP

Feng Xiujuan National Institute of Metrology (NIM),China

Uncertainty Evaluation of Effective Radiation Area of Ultrasound Transducers: Preliminary Results of Inmetro s Laboratory of Ultrasound

Current Status of Ultrasonic Device Calibration in China

Annular Array Transducer and Matched Amplifier for Therapeutic Ultrasound

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ACOUSTICS, ULTRASOUND AND VIBRATION METROLOGY

TECHNICAL SPECIFICATION

Sam Howard PhD Tests & measurements, Onda Corporation. Timothy Demchek PhD - Human tissue heating, Indian State University

Ultrasound Measurements and Non-destructive Testing Educational Laboratory

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Physikalisch-Technische Bundesanstalt

Descriptions of NDT Projects Fall 2004 October 31, 2004

Ultrasound in Medicine

ULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS

TECHNICAL SPECIFICATION

The Physics of Ultrasound. The Physics of Ultrasound. Claus G. Roehrborn. Professor and Chairman. Ultrasound Physics

A new method of sonograph lateral resolution measurement using PSF analysis of received signal

HiFFUT A New Class of Transducer

Ultrasonic Transducer. Piezoelectric ceramics / Piezoelectric polymer film / Piezoelectric thin film

Integrative Solution for In-situ Ultrasonic Inspection of Aero-engine Blades Using Endoscopic Cheap Optical Transducers (CHOTs)

INTERNATIONAL STANDARD

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound

EURAMET TC-AUV Report to CCAUV11

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

Status report of KRISS AUV for the 11 th CCAUV meeting

Essentials of Medical Ultrasound

High power density prototype for high precision transcranial therapy

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques

MEASUREMENTS OF ULTRASONIC CAVITATION IN LIQUIDS AND TISSUE MIMICKING MATERIALS

Electrotherapy, ultrasound therapy, combined therapy, laser therapy and magnetotherapy Etius ULM

The Yesterday, Today and Tomorrow of Focused Ultrasound Surgery CHONGQING HAIFU (HIFU) TECHNOLOGY CO., LTD.

Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer

Contents Ultra ICE Plus 9 MHz Imaging Catheter MDU5 PLUS Sterile Bag 26 gauge needle 10 ml (cc) syringe

Automatic quality control processing for detection of element/channel dropout in ultrasound transducers

warwick.ac.uk/lib-publications

This document is a preview generated by EVS

The table below shows the density and velocity of waves in two different substances. Density / kg m 3 Velocity / m s 1

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Ultrasonic Testing Level I:

Walls of Sound: The acoustic field of multiple vessels hammering on metal pipes

Basic Physics of Ultrasound and Knobology

Physikalisch-Technische Bundesanstalt

Introduction to Biomedical Imaging

VISUALIZATION OF TRANSDUCER-PRODUCED SOUND FIELDS IN SOLIDS

Consultative Committee for Acoustics, Vibration and Ultrasound CCAUV

Stress Wave Focusing Transducers

Supplementary Movie Caption

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

Contents Ultra ICE Plus - PI 9 MHz Peripheral Imaging Catheter MDU5 PLUS Sterile Bag 26 gauge needle 10 ml (10 cc) syringe

Vibration Analysis & Practical Solutions

Transcranial Pulsed Ultrasound Stimulates Intact Brain Circuits

Ultrasound Physics and Knobology Alan Macfarlane. Consultant Anaesthetist Glasgow Royal Infirmary

Ultrasonic transducers

FOR MORE THAN 60 YEARS, therapeutic ultrasonography

RADIATION MONITORING DEVICES R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S

Heat Drain Device for Ultrasound Imaging Probes ESAOTE SPA

Modeling of Thermal Damage from Focused Ultrasound Exposures for Heterogeneous Tissues

ACOUSTORAPHY Acousto-Optical (AO) Ultrasonics & Its Applications

Section 1. Executive Summary

Can you believe that the ultrasonic waves are used for cleaning purpose???

A Methodology for Ultrasound Product Development Applications in HIFU and High Frequency

Ultrasonic Measurement of Aircraft Strut Hydraulic Fluid Level

Signals, systems, acoustics and the ear. Week 1. Laboratory session: Measuring thresholds

Characteristics of Liquids Atomization Using Surface Acoustic Wave

Q1. The diagram shows an ultrasound monitor being used to scan a fetus.

DIGITAL IMAGE PROCESSING IN ULTRASOUND IMAGES

Physical Principles of Ultrasound

DEVELOPMENT OF ULTRASONIC TESTING TECHNIQUE TO INSPECT CONTAINMENT LINERS EMBEDDED IN CONCRETE ON NUCLEAR POWER PLANTS

PainShield MD User Manual

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Test Procedure for Piezoelectric Accelerometer Ice Thickness Measurement

GUIDANCE FOR INDUSTRY

Patient - Ultrasound Interaction. latest developments and efforts in medical ultrasound safety topics and bio-effects research.

SYNCHRONIZED MEASUREMENTS OF MAXIMUM BLOOD FLOW VELOCITIES IN CAROTID, BRACHIAL AND FEMORAL ARTERIES, AND ECG IN HUMAN POSTURE CHANGES

YY Translated English of Chinese Standard: YY PHARMACEUTICAL INDUSTRY STANDARD

COURSE DESCRIPTION FOR NONDESTRUCTIVE TESTING

Musculoskeletal Ultrasound: Basics, Utility, and Clinical Applications

AN ULTRASONIC MESH SENSOR FOR TWO-PHASE FLOW VISUALISATION

Proceedings of Meetings on Acoustics

EC6001 MEDICAL ELECTRONICS

DEVELOPMENT OF ELECTROMAGNETIC ACOUSTIC TRANSDUCER (EMAT) PHASED ARRAYS FOR SFR INSPECTION

Lesson 03: Sound Wave Propagation and Reflection. This lesson contains 15 slides plus 14 multiple-choice questions.

TC for Acoustics, Ultrasound and Vibration: Highlights Salvador Barrera-

ultrasonic instruments and devices i reference for modern instrumentation techniques and technology physical acoustics volume xxiii

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions.

Case studies on uncertainties of ultrasonic weld testing interpretation

IEC/TC 29 Electroacoustics. Status: September 2010

Non-Destructive Inspection of Composite Wrapped Thick-Wall Cylinders

Performance of force comparator with reference to tuning-fork type force transducer

Kadi Sarva Vishwavidyalaya Gandhinagar

Metrology Thought Leader

Ultrasound 10/1/2014. Basic Echocardiography for the Internist. Mechanical (sector) transducer Piezoelectric crystal moved through a sector sweep

A PRELIMINARY ANALYSIS OF POSSIBILITIES OF COMPENSATING FAULTS OF LASER AND ULTRASONIC TECHNOLOGIES IN SURGERY. Tadeusz GUDRA, Sylwia MUC

Linear Ultrasonic Wave Propagation in Biological Tissues

Transcription:

NMIJ measurement service on ultrasonic field parameters available to demonstrate performance and safety of ultrasonic medical equipment Masahiro Yoshioka National Metrology Institute of Japan (NMIJ) National Institute of Advanced Industrial Science And Technology (AIST)

Needs of ultrasonic measurement for ultrasonic medical equipment Demonstration of performance and safety required in International Standards Output control to balance efficiency and safety on diagnostic and therapy

NMIJ ultrasonic standards to provide measurement services Ultrasonic power Ultrasound pressure (Hydrophone sensitivity) Ultrasonic field parameters

Ultrasonic field characterization for Medical diagnostic equipment using IEC 62359 Ultrasonic field Measurement Ultrasonic power Ultrasound pressure Measurement, Calculation Ultrasonic field parameters Characterization Thermal Index Mechanical Index

Calibrated devices by NMIJ ultrasonic measurement services Hydrophone:Microphone for ultrasound in water Ultrasonic transducer: Ultrasound source Ultrasonic wave

Ultrasonic power standard Ultrasonic power: Energy per unit time of ultrasonic wave passing a certain plane (Unit: W) Ultrasonic power on sound source of medical equipment is indispensable for evaluation of ultrasonic output

Ultrasonic power calibration system using Radiation force balance Absorbing target Ultrasonic transducer Electric balance

Development of high output ultrasonic power standard Back ground Need has emerged for measurement of therapeutic high power ultrasound Problem on Radiation Force Damage of absorbing target by high power ultrasound exposure High power calibration system using calorimetric method is developed in NMIJ

High ultrasonic power calibration using calorimetric method Ultrasonic transducer

Ultrasound pressure standard Ultrasound pressure: Variation from static pressure by ultrasonic wave at a certain point (Unit: Pa) Parameters characterizing ultrasonic field is derived using instantaneous ultrasound pressure or that spatial distribution Ultrasound pressure standard is indispensable for demonstrating performance and safety of medical equipment

Ultrasound pressure standard is provided by hydrophone sensitivity calibration (Unit: V/Pa) Membrane type Needle type

Reciprocity calibration system of hydrophone sensitivity up to 1 MHz Receiver (Hydrophone, Ultrasonic transducer) Transmitter (ultrasonic transducer) Absorber

Hydrophone calibration system using laser interferometry for frequency Laser interferometer range up to 40 MHz Pellicle reflecting optically Small diameter (2 mm) ultrasonic transducer developed for expanding calibration frequency range up to 40 MHz

Ultrasonic field parameter standard Manufacture or distributor of ultrasonic medical diagnostic equipment required to demonstrate performance and safety of their products according to International Standards For validation of ultrasonic field measurement by manufacture or distributor, 3 ultrasonic field parameters are calibrated with reference transducer in NMIJ

Calibrated ultrasonic field parameters Peak-rarefactional acoustic pressure p r (Unit: Pa) Maximum of modulus of negative instantaneous acoustic pressure Spatial-peak temporal-average intensity I spta Spatial-average temporal-average intensity I sata (Unit: W/cm 2 ) (Acoustic) Intensity: Ultrasonic power per unit area at a certain point

Block diagram of ultrasonic field parameter calibration system Motorized stage Calibrated device Thermo -meter Water vessel Ultrasonic wave Hydrophone calibrated in NMIJ AD converter Clock Trigger Clock generator Computer Ultrasonic transducer Signal generator Frequency counter

Ultrasonic power Hydrophone sensitivity Ultrasonic field parameters Summary of NMIJ ultrasonic measurement services Method Radiation force balance Calorimetry Calibration range 1 mw - 500 mw (15 MHz - 20 MHz) 1 mw - 15 W (0.5 MHz - 15 MHz) 15 W - 100W (1 MHz - 3 MHz) Expanded uncertainty (Level of confidence 95 %) 5 % - 12 % 9 % Reciprocity 100 khz - 1 MHz 10 % - 13 % Laser 0.5 MHz - 40 MHz interferometry 6.1 % - 17 % p R 7 % - 10 % Plane scan 0.5 MHz - 20 MHz I SPTA 14 % - 20 % I SATA 14 % - 21 %

Ultrasonic power Future works Expanding calibration range: 200 W Hydrophone sensitivity Expanding frequency range: 50 khz -100 MHz Technique for phase response calibration Ultrasonic field parameter Adding Effective radiating area, Beam nonuniformity ratio required for ultrasonic physiotherapy equipment