The ABL800 FLEX Setting the standard

Similar documents
USING THE ACCESS AMH ASSAY IN YOUR LABORATORY

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link. Fully-Automated HbA 1c Testing

5 BEST PRACTICES To Patient Safety. A Practical Guide to Blood Glucose Testing

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link System. Fully-Automated HbA 1c Testing

TOPICS IN AMPLIFICATION

Bio-Rad Laboratories. Hemoglobin Testing. VARIANT II Hemoglobin Testing System For HbA 1c

Applicable To Employees of Gundersen Boscobel Area Hospital Laboratory and Gundersen Palmer Lutheran Hospital and Clinics Laboratory.

for therapeutic drug monitoring

C RITICAL C ARE 2. Angelo Manzoni, Susanna Zanardi, Pietro Zonca Jay Johnson. Glucose biosensor for whole blood analysis

White Paper, Evaluation of WaveSense JAZZ Blood Glucose Monitoring System Analytical Performance to EN ISO 15197:2015 Standard

Navigate Complex Interventions at Every Turn

NobelProcera Implant Bar Overdenture complete range of fixed and removable solutions.

Choosing Mindray SpO2

C RITICAL C ARE. Davide Colombo Kevin Flanagan Kevin Fallon. The IL Glucose Biosensor: Interfering Substance Studies.

HemoCue Hb METHOD AND SAMPLE COLLECTION

Bio-Rad Laboratories. Cardiac Assessment Controls. Value Assigned for Clinical Laboratory and Point of Care Test Systems

Creatinine Test Code: CRE

Acute renal failure Definition and detection

Third Party Controls for Your Dade Behring Systems

Chemical compatibility of the Pall QPoint TM Docking Station - Tap Assembly with common surface disinfectants

Diagnostic reagent for quantitative in vitro determination of Urea / Blood Urea Nitrogen in serum, plasma and urine by colorimetry.

Standardization of. S.M.Boutorabi DCLS,PhD

VARIAN ONCOLOGY. RapidArc. One revolution is all it takes.

Patient: 55 y female (ambulatory)

Applicable To Employees of Gundersen Boscobel Area Hospital laboratory and Gundersen Palmer Lutheran Hospital and Clinic Laboratories.

ab Hemoglobin Assay Kit (Colorimetric)

Stax Disposable Depth Filters

RENAL FUNCTION ASSESSMENT ASSESSMENT OF GLOMERULAR FUNCTION ASSESSMENT OF TUBULAR FUNCTION

Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on. CUBE analyser (CA0100)

Cell Culture Monitoring with the Vi-CELL MetaFLEX

C56-A Hemolysis, Icterus, and Lipemia/Turbidity Indices as Indicators of Interference in Clinical Laboratory Analysis; Approved Guideline

Determination of hemoglobin is one of the most commonly

GLUH PRINCIPLE REF B ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

Cardiac Assessment Controls

CLINITEK Novus Automated Urine Chemistry Analyzer

Results you can trust

Internal Calibration System of Thermo Scientific Varioskan Flash with Improved Sensitivity, Accuracy and Dynamic Range

Cystatin C (serum, plasma, urine)

Comparison of Three Whole Blood Creatinine Methods for Estimation of Glomerular Filtration Rate Before Radiographic Contrast Administration

PRODUCT INFORMATION. New Reagents for Dako CoverStainer. Choose the H&E staining intensity you want.

Creatinine (serum, plasma)

POWERFUL PERSPECTIVES

The analytical phase

Endo Fascial Closure System

The first and only fully-automated, multiplexed solution for Measles, Mumps, Rubella and Varicella-zoster virus antibody testing

Protect Your Mass Spec

ImmunoCAP Systems. Optimized for allergy testing - Precision - Accuracy - Consistency

How can I meet all of my arterial blood collection needs?

One intelligent solution

MagPro by MagVenture. Versatility in Magnetic Stimulation

THe Time is NOw CHRONOS 9 AUDIO EFFICIENCY TM

Original Article Interfering effect of bilirubin on the determination of alkaline phosphatase

Dako IT S ABOUT TIME. Interpretation Guide. Agilent Pathology Solutions. ALK, ROS1 and RET IQFISH probes (Dako Omnis) MET IQFISH probe (Dako Omnis)

For In Vitro Diagnostic Use

One intelligent solution

In-Use Evaluation Report

HbA1c3 PRINCIPLE REF B ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

SYSTEM ELIGIBILITY BATTERY LONGEVITY

ILyte TM Automated electrolyte analyzers

FreeStyle Lite A Blood Glucose Meter That Requires No Coding

NobelProcera Implant Bar Overdenture EXPERIENCE THE NEW WORLD OF CAD/CAM DENTISTRY

WESTERN EUROPE PREVALENCE AND INCIDENCE OF PERIPHERAL ARTERY DISEASE AND CRITICAL LIMB ISCHEMIA 2017

Introducing the TrueBeam STx system with Novalis Radiosurgery.

Topics in Amplification DYNAMIC NOISE MANAGEMENT TM A WINNING TEAM

Gentian Canine CRP Immunoassay Application Note for Abbott Architect * c4000

Cardiac Assessment Controls A critical element of reliable cardiac testing

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY AND INSTRUMENT COMBINATION TEMPLATE

G. Snodgrass, K. Ackles, A. Blanco and A. Versaggi Ortho Clinical Diagnostics, Rochester, NY 14626

I. Subject: Ionized Calcium (Ca++) Analysis Whole Blood

ab Lipid Extraction Kit (Chloroform-Free)

NobelDesign 1.3 Installation guide

RENAL BIOMARKERS: TECHNOLOGIES AND GLOBAL MARKETS

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems.

IDEXX Catalyst One Chemistry Analyzer for In-house Measurement of Total Thyroxine (TT 4 ) Concentration in Serum from Dogs and Cats

TGX and TGX Stain-Free FastCast Acrylamide Kits

Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D

SENSATION and CS300 Smaller meets faster. IABP System

i-stat CHEM8 + Cartridge Quick Reference Guide

FT-Raman Surface Mapping of Remineralized Artificial Dental Caries

The first convertible endotracheal tube

ab Creatinine Assay Kit (Colorimetric)

BEFLEX CUSTOMER SURVEY 2016

ICT (Na +, K +, Cl ) Sample Diluent

HbA1c PRINCIPLE REF ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

Infinity MCable -Masimo SET

New global report highlights silent epidemic of kidney disease and neglect of treatment and prevention in all countries

TRUE Meter Guide. Accurate and precise results for managing your diabetes effectively and affordably. because it fits your lifestyle!

Department of Clinical Pathology, Faculty of Medicine Padjadjaran University-Dr. Hasan Sadikin General Hospital 2

Nonin Medical OEM Pulse Oximetry Solutions. Superior Performance for Challenging Patient Conditions

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Radiotherapy and Radiosurgery

Immediate Pathology Results Now Available for all Remote Northern Territorians

ab Mammalian Cell Lysis Buffer 5X

BLOOD GLUCOSE METERS ACCURACY REQUIREMENTS

508 the number of suicide deaths in deaths per 100,000 people was the suicide rate in Suicide deaths in 2013 by gender

LOGIQ E9 with XDclear

MagPro by MagVenture. Versatility in Magnetic Stimulation

ab Glucose Uptake Assay Kit (colorimetric) 1

D7.1 Report summarising results of survey of EU countries to identify volumes and trends in relation to the import and export of stem cells

D7.1 Report summarising results of survey of EU countries to identify volumes and trends in relation to the import and export of stem cells

Transcription:

The ABL800 FLEX Setting the standard SIMPLY DEDICATED

Setting the standard for fast and reliable measurements A look behind Radiometer s superior sensor technology Since the introduction, Radiometer s ABL Series has set the standard for fast and reliable measurements of blood gas and related parameters. The ABL800 FLEX is a prime example of this proud tradition. Today, the ABL800 FLEX is found wherever fast, accurate STAT measurements are needed; e.g. central labs, ICUs, NICUs, blood gas labs, operating and emergency rooms. A superior sensor technology has contributed to the succes of the ABL800 FLEX and in this brochure, you will find out more about what makes our sensors so unique. The first step in achieving an accurate result starts with the quality of the sample. The ABL800 FLEX has set the bar for fast and reliable testing by ensuring safe sampling, technology that accurately matches the right patient information with the right sample, and automatic mixing of samples to avoid preanalytical errors. When measuring oximetry and metabolites such as glucose, lactate, bilirubin and creatinine, the effect of interfering substances has proven to be a source of difficulty for many STAT analyzers. Not so for the ABL800 FLEX. Thanks to its superior and proven sensor technology, the ABL800 FLEX handles these parameters with dependable precision, providing you with a complete and accurate picture of patient status. In this brochure, we go behind the ABL800 FLEX sensor technology and explain how it works and how it can change your everyday work. This is, however, just the first step in ensuring that you get the best possible result in order to provide fast diagnosis and treatment. The second step is accurate measurements offered by unique sensor technology as explained in the following pages. Safe sampling Accurate data capture Mixing of samples

High stability for true STAT readiness Glucose and lactate Creatinine Radiometer s ABL800 FLEX offers glucose and lactate measurements with no interference from commonly seen substances. Unique stability and long lifetime of the sensors ensure maximum uptime and low operational costs. Interference suppression ensures reliable results Errors due to varying hematocrit and oxidizable compounds such as acetaminophen are a common problem with many glucose and lactate analyzers. In the ABL800 FLEX these common substances have been demonstrated not to interfere, even in up to several times the toxic concentration recommended by the National Committee for Clinical Laboratory Standards (NCCLS) [1]. For example, acetylsalicylic acid has been tested in a concentration of 3 mmol/l (54.0 mg/dl), which is approximately three times the toxic level. Interference testing for glucose and lactate mmol/l mg/dl H 2 O 2 2H+O 2 +2e - Lactate oxidation Platinum anode Inner membrane results in H 2 O 2 Enzyme layer Outer membrane Blood sample The concentration of creatinine provides information on kidney function and muscle mass. There is a poor track record for creatinine in other measurement systems [2], and a fluctuation in results due to interference is one of the main problems for creatinine measurements. Interference suppression ensures reliable results Radiometer s experience with interference suppression has been transferred to the creatinine measuring system. Through its choice of sensor technology, Radiometer have been able to suppress interference from a significant number of substances that cause problems on other measuring systems. Interference (µmol/l) Acetoacetate 10 mmol/l < 8 Acetaminophen (paracetamol) 1.7 mmol/l < 8 Creatine 200 µmol/l < 8 Cyclosporin 12 µmol/l < 8 Dopamine 5.9 µmol/l < 8 The ABL800 FLEX reports GFR according to the method laid down in the Modification of Diet in Renal Disease (MDRD) Study recommended by the National Kidney Disease Education Program (NKDEP). GFR reporting feature on the ABL800 FLEX is pending. Standardization of creatinine measurement An accurate result is a prerequisite of precise and comparable GFR measurements. Acetylsalicylic acid 3 54.0 Dopamine 1 15.3 Salicylic acid 4 55.2 Acetaminophen (Tylenol, paracetamol) 2 30.2 Bilirubin, unconjugated 0.34 20.0 Blood cells Interfering substance Glucose/lactate H 2 O 2 The inner and outer membrane layers of the glucose/lactate sensors prevent blood cells and various interfering compounds from reaching the electrode. Hydroxyurea 100 µmol/l < 8 Source: Reference Manual In total, 62 different endogenous and exogenous substances were identified and subjected to an interference test protocol on creatinine. None of them showed detectable signs of interference. Radiometer creatinine measurements follow the standardization recommended by NKDEP. The purpose of NKDEP is to reduce the morbidity and mortality caused by kidney disease and its complications. It has defined boundaries for combinations of systematic bias and imprecision in serum creatinine measurements. Bilirubin, conjugated 0.46 40.0 Ascorbic acid 2 35.2 Some of the substances that have been shown to have an intereference of less than 0.1 mmol/l (1.80 mg/dl) on glucose measurements and 0.1 mmol/l (0.90 mg/dl) on lactate measurements. Glomerular Filtration Rate (GFR) GFR is recognised to have great importance in the early detection and management of chronic kidney disease. The GFR indicates how effectively the kidneys clear out the substrates from the body. Besides creatinine, the GFR algorithm is based on age, gender and race. 1 NCCLS: Interference testing in clinical chemistry; Proposed guideline. NCCLS publication EP/-P. Villanova Pa. 2 Myers GL, Miller WG, Coresh J et al. Recommendations for improving serum creatinine measurement: a report from the National Kidney Disease Education Program. Clin Chem 2006; 52: 5-18.

Oximetry - unique technology eliminates maintenance and ensures accuracy The oximeter used in ABL800 FLEX instruments is widely regarded as the gold standard for STAT analyzers. The oximeter s 128-wavelength spectrophotometer automatically corrects interferences that can impair the accuracy of oximetry parameters. The result is clearly indicated by measurement precision, sample after sample. Full oximetry at 128 wavelengths Radiometer s 128-wavelength spectrophotometer measures a full range of oximetry parameters, including total bilirubin on whole blood. 128 wavelengths ensure that all the details of the measured spectrum are revealed, providing a highly precise spectral blueprint. The advantage of having this vital information is that the ABL800 FLEX is able to detect and subsequently suppress interferences from commonly seen substances. Bilirubin, conjugated Bilirubin, unconjugated 40 mg/dl 20 mg/dl Intralipid 0.4-0.8 % SulfHb 10 % Evans Blue Cardio Green 5 mg/dl 5 mg/dl The above table lists some of the substances that have been shown to cause interference of less than 0.5 g/dl on cthb and less than 1 % interference on hemoglobin derivatives and so 2 measurements in the ABL800 FLEX. Quantitative bilirubin measurements Quantitative bilirubin measurements on whole blood was first introduced by Radiometer. Together with its fetal hemoglobin measurement and small sample size the ABL800 is an ideal choice for neonatal ICUs. No drift ensures high measuring quality The ABL800 FLEX oximeter is equipped with a neon lamp which generates constant spectral lines. The function of the spectral lines is to serve as references to ensure that there is no drift in the 128 wavelengths used in the spectrophotometer. The neon lamp controls that any deviations are automatically detected and corrected, ensuring a constantly high measuring quality. Absorption Interference detected and corrected Model spectrum Measured spectrum Wavelength The 128 wavelenghts provide a precise spectral blueprint. By comparison of the model spectrum with the measured spectrum, any interference is detected and subsequently suppressed. High accuracy and precision The net result of the oximeter s design is measurement accuracy and precision. For example, the ABL800 FLEX is able to measure cthb with a repeatability of less than 0.15 g/dl on cthb levels between 7.0 g/dl and 25.0 g/dl. Eliminated influence of non-hemolyzed blood The Radiometer oximeter hemolyzes blood samples with ultrasound waves inside the measuring cuvette itself. With the blood being hemolyzed inside the measuring cuvette, the blood sample does not have to be moved after hemolyzation. This eliminates the possibility of the measured sample being mixed with nonhemolyzed blood, and thereby ensures maximal accuracy (Fig. 1). Avoid clots Oximeter clots are a frequent and serious problem. The ABL800 FLEX reduces the risk of clots in two ways: 1. The analyzer s sample aspiration port is only 0.1 mm in diameter, preventing most clots from even entering the measuring path. 2. The oximeter is equipped with intra-cuvette hemolyzation. The measuring cuvette destroys potential clots ultrasonically during the hemolyzation process. Fewer bubbles The design of the ABL800 FLEX oximeter prevents the formation of air bubbles by carrying out the intra-cuvette ultrasound hemolyzation under over-pressure. An over-pressure of one atmosphere is maintained not only during the hemolyzing process but until the measurement has been completed. Such maintenance improves the precision of the measurement (Fig. 3). Prevent deposits After each measurement, the oximeter ultrasonically cleans the cuvette s glass walls, knocking loose deposits before they build up. This eliminates the need to replace the glass a costly and time-consuming procedure with other analyzers and keeps the oximeter completely maintenance-free (Fig. 4). Before hemolyzation During hemolyzation FIG. 1 Before hemolyzation During hemolyzation FIG. 2 1 atm. over-pressure Radiometer hemolyzer FIG. 3 Before cleaning Deposits Automatic detection and correction for interfering substances The spectra of the common interferences are stored in the ABL800 FLEX software. The analyzer compares the model spectrum with the measured spectrum. Any deviations caused by interferences (such as lipids, HbF, SMb, ph, Cardio Green, Evans Blue, betacarotene, Patent Blue V, methylene blue, HiCN) are detected and suppresed, ensuring high accurancy. Ultrasonic cleaning FIG. 4

www.bloodgas.org is a knowledge site with practical information on blood gas and critical care testing. Analysis Satisfaction Analyzers Technical Support Red System IT Systems Training QA Support Samplers and QC Sales companies: Country: Radiometer representative: Telephone: E-mail: Website: Australia: Radiometer Pacific Pty. Ltd. (+61) 3 9259 2222 sales@radiometer.com.au www.radiometer.com.au Canada: Radiometer Canada (+1) 877 414 0447 (toll free) info@radiometercanada.com www.radiometer.ca China: Radiometer China (+86) 21 6354 3387 pol@radiometer.com.cn www.radiometer.cn Denmark: Radiometer Danmark A/S (+45) 38 27 28 29 rdan@radiometer.dk www.radiometer.dk France: Radiometer S.A.S. (+33) 1 49 44 35 50 marketing@radiometer.fr www.radiometer.fr Germany: Radiometer GmbH (+49) 2154 818-0 info@radiometer.de www.radiometer.de Ireland: Radiometer Ireland Ltd. (+353) 1 888 3611 sales@radiometer.ie www.radiometer.ie Japan: Radiometer K.K. (+81) 3 5777 3500 salesdep@radiometer.co.jp www.radiometer.co.jp The Netherlands: Radiometer Nederland BV (+31) 79 361 4593 info@radiometer.nl www.radiometer.nl New Zealand: Radiometer New Zealand (+64) 9 574 1400 sales@radiometer.co.nz www.radiometer.co.nz Poland: Radiometer Sp.z.o.o. (+48) 22 518 02 40 info@radiometer.pl www.radiometer.pl Portugal: Radiometer Ibérica, S.A. (+351) 214 12 39 70 rapor@radiometer.es www.radiometer.pt Spain: Radiometer Ibérica, S.A. (+34) 91 655 99 50 resp@radiometer.es www.radiometer.es Switzerland: Radiometer GmbH (+41) 44 723 38 60 info@radiometer.ch www.radiometer.ch United Kingdom: Radiometer Ltd. (+44) 1293 517 599 sales@radiometer.co.uk www.radiometer.co.uk USA: Radiometer America, Inc. (+1) 800 736 0600 (toll free) info@radiometeramerica.com www.radiometeramerica.com Other countries: Radiometer International (+45) 38 27 38 27 rint@rint.dk www.radiometer.com Sales Division Data subject to change without notice. ABL, Radiometer and Red System are trademarks of Radiometer Medical ApS, Denmark. ABL is registered in the USA. Radiometer Medical ApS, DK-2700 Brønshøj, 2006. All rights reserved. 928-548. 200611B.