Aortic aneurysms and trans-apical endovascular repair in high risk heart transplant recipient, one year follow up

Similar documents
Ascending Aorta: Is The Endovascular Approach Realistic?

Ascending Aorta: The Endovascular Approach

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

Aortic stents, types, selection, tricks in deployment.

Acute dissections of the descending thoracic aorta (Debakey

Antegrade Thoracic Stent Grafting during Repair of Acute Debakey I Dissection: Promotes Distal Aortic Remodeling and Reduces Late Open Re-operation

Arch Repair with the Bolton Medical RelayBranch Thoracic Stent-graft system: Multicenter experience

Title. Different arch branched devices are available, is morphology the. main criteria of choice? Ciro Ferrer, MD

Development of a Branched LSA Endograft & Ascending Aorta Endograft

Percutaneous Approaches to Aortic Disease in 2018

Intravascular Ultrasound in the Treatment of Complex Aortic Pathologies. Naixin Kang, M.D. Vascular Surgery Fellow April 26 th, 2018

Management of Acute Aortic Syndromes. M. Grabenwoger, MD Dept. of Cardiovascular Surgery Hospital Hietzing, Vienna, Austria

Redo treatment and open conversion after TEVAR

Endovascular repair of ascending aorta pseudoaneurysm

SELECTIVE ANTEGRADE TECHNIQUE OF CHOICE

Lulu Liu, Chaoyi Qin, Jianglong Hou, Da Zhu, Bengui Zhang, Hao Ma, Yingqiang Guo

Endovascular Repair of Aortic Arch/Thoracic Aneurysms: Bolton RelayBranch Device

Nellix Endovascular System: Clinical Outcomes and Device Overview

Transcatheter Aortic Valve Implantation as a Bailout Procedure for Acute Aortic Valve Regurgitation During Endovascular Arch Repair

Type II arch hybrid debranching procedure

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Talent Abdominal Stent Graft

Abdominal and thoracic aneurysm repair

Ascending Aorta: Is The Endovascular Approach Realistic?

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke

Total Endovascular Repair Type A Dissection. Eric Herget Interventional Radiology

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

CUSTOM-MADE SCALLOPED THORACIC ENDOGRAFTS IN DIFFERENT HOSTILE AORTIC ANATOMIES

Annual Clinical Update

Access More Patients. Customize Each Seal.

Experience of endovascular procedures on abdominal and thoracic aorta in CA region

The Petticoat Technique Managing Type B Dissection with both Early and Long Term Considerations

Left subclavian artery (LSA) coverage during

The Current Status Of Endovascular Repair Of Ascending Aorta And Aortic Arch

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Jean M Panneton, MD Professor of Surgery Program Director Vascular Surgery Chief EVMS. Arch Pathology: The Endovascular Era is here

Endovascular therapy for Ischemic versus Nonischemic complicated acute type B aortic dissection (catbad).

How to achieve a successful proximal sealing in TEVAR? Pr L Canaud

Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices?

Tips and Tricks to Deliver a Stengraft to the Ascending Aorta

Introducing the GORE TAG Conformable Thoracic Stent Graft with ACTIVE CONTROL System

Optimal repair of acute aortic dissection

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

3 : 37. Kirit Patel, USA CLASSIFICATION DIAGNOSIS

I-Hui Wu, M.D. Ph.D. Clinical Assistant Professor Cardiovascular Surgical Department National Taiwan University Hospital

Current State of Thoracic Branch Devices and Ongoing Clinical Trials

Aortic Arch Treatment Open versus Endo Evidence versus Zeitgeist. M. Grabenwoger Dept. of Cardiovascular Surgery Hospital Hietzing Vienna, Austria

An Overview of Post-EVAR Endoleaks: Imaging Findings and Management. Ravi Shergill BSc Sean A. Kennedy MD Mark O. Baerlocher MD FRCPC

Aortic Arch pathology options: Open,Hybrid, fenestration, Chimney or branched stent-graft?

AORTIC DISSECTIONS Current Management. TOMAS D. MARTIN, MD, LAT Professor, TCV Surgery Director UF Health Aortic Disease Center University of Florida

Hybrid procedure to treat aortic arch aneurysm combined with aortic arch coarctation and left internal carotid artery aneurysm (Case Report)

Acute Type B dissection. Closure of the infra diaphragmatic tear: how and when?

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

Modification in aortic arch replacement surgery

Development of Stent Graft. Kato et al. Development of an expandable intra-aortic prothesis for experimental aortic dissection.

Protective effect of angulated aorta for saving coronary artery during endovascular repair for ascending aortic pseudoaneurysm

Combined Endovascular and Surgical Repair of Thoracoabdominal Aortic Pathology: Hybrid TEVAR

Endovascular Ascending Repair: Is This the Next Frontier?

Percutaneous Transapical Access for Thoracic Endovascular Repair

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

Open fenestration for complicated acute aortic B dissection

Patient Information Booklet

The catheter-based treatment of valvular disease and aortic

Cite this article as:

Technique and Tips for Complicated AAA Cases with Stent Graft

Ancillary Components with Z-Trak Introduction System

EVAR replaced standard repair in most cases. Why?

LOWERING THE PROFILE RAISING THE BAR

State of Art Hybrid Approach

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

TriVascular Ovation Prime Abdominal Stent Graft System

Considerations for a Durable Repair

Endo-Bentall: Fact or Fiction?

Description. Section: Surgery Effective Date: April 15, Subsection: Surgery Original Policy Date: December 6, 2012 Subject:

Frozen elephant trunk for DeBakey type 1 dissection: the Cleveland Clinic technique

Use of carotid subclavian arterial bypass and thoracic endovascular aortic repair to minimize cerebral ischemia in total aortic arch reconstruction

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

DIFFICULT ACCESS REMAINS A CONTRAINDICATION FOR EVAR APOSTOLOS K. TASSIOPOULOS, MD, FACS PROFESSOR AND CHIEF DIVISION OF VASCULAR SURGERY

Descending aorta replacement through median sternotomy

Aggressive Resection/Reconstruction of the Aortic Arch in Type A Dissection

My personal experience with INCRAFT in standard and challenging cases

Thoracic aortic trauma A.T.O.ABDOOL-CARRIM ACADEMIC HEAD VASCULAR SURGERY DEPARTMENT OF SURGERY UNIVERSITY OF WITWATERSRAND

Minimally Invasive Aortic Arch Surgery:

Dissection of descending aorta treated by stent-graft implantation in a patient with Marfan syndrome

Indications for use. Contraindications within the United States

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

COMPLICATIONS OF TEVAR

Thoracoabdominal Aorta: Advances and Novel Therapies

Emerging Roles for Distal Aortic Interventions in Type A Dissection Surgery

Successful percutaneous treatment of late-onset femoral pseudoaneurysm after transcatheter, aortic valve implantation procedure

Hybrid Repair of a Complex Thoracoabdominal Aortic Aneurysm

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice

Combined Open and Endovascular Repair for Aortic Arch Pathology

Endovascular treatment of aortic arch using Relay branched stent grafts

DISCLOSURES ISOLATED DTA LESION? TYPE B DISSECTIONS TREATMENT OPTIONS

Periprosthetic leak and rupture after endovascular repair of abdominal aortic aneurysm: The significance of device design for long-term results

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA

Transcription:

Case Report Aortic aneurysms and trans-apical endovascular repair in high risk heart transplant recipient, one year follow up Khalil Ahmad 1, Kim Terp 1, Gratien Andersen 2, Vibeke Hjortdal 1 1 Department of Cardiothoracic and Vascular Surgery, Institute of Clinical Medicine, 2 Department of Radiology, Aarhus University Hospital, Aarhus, Denmark Correspondence to: Khalil Ahmad, MD. Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Palle Juul Jensens Boulevard 99, DK-8200 Aarhus N, Denmark. Email: khahma@rm.dk. Abstract: Aortic aneurysms cause major morbidities and mortalities. Operative intervention in ascending aneurysms and dissections is the treatment of choice although there is the risk of major complications because of technical difficulties, late diagnoses, affected hemodynamic and organ mal perfusion. Improved survival of heart transplant (HTx) recipients, acceptance of older donors with co morbidities and advances in HTx give rise to new pathological challenges in the cardiovascular field. Only a few articles have been reported about cardiac and aorta surgery in HTx recipients. Endovascular treatment for aortic pathology in zone 0 is an emerging treatment option. We report the first trans-apical endovascular ascending aorta repair (EVAR) in a 26-year-old HTx recipient, with the history of mediastinitis and lack of femoral access. She had an uneventful operative and post-operative EVAR course. Keywords: Aneurysm; endovascular; aorta; endovascular ascending aorta repair (EVAR) Submitted May 13, 2015. Accepted for publication Sep 06, 2015. doi: 10.3978/j.issn.2072-1439.2015.11.12 View this article at: http://dx.doi.org/10.3978/j.issn.2072-1439.2015.11.12 Introduction Endovascular repair has become the golden treatment option for high risk patients with thoracic and abdominal aneurysms specially in re-do procedures. The ascending aorta and aortic arch pose specific challenges to endovascular approaches because of the origin of supraaortic trunks, hemodynamic forces, respiratory motion, angulations of the inner aortic curvature and proximity to the coronary arteries and aortic valve (1). The anatomical complexities of ascending aorta and windsock phenomenon make endovascular ascending aorta repair (EVAR) challenging and may cause stent graft specific complications as distal migration, endoleak, stent fracture, kinking, aneurysm rupture or procedure related complications such as stroke, paraplegia, cardiovascular events, respiratory failure, renal failure, intestinal ischemia, and reoperations. Case presentation A 26-year-old woman with no previous co-morbidity or risk factors developed uncontrollable idiopathic ventricular fibrillations on the forth post-partum day. Cardiopulmonary support (CPS) was instituted for a week. Two days after being weaned from CPS, she suffered from new events of Life-threatening ventricular tachycardia and fibrillations. Mechanical circulation was reinstituted. She developed gastrointestinal bleeding which was controlled by coiling of colon arteries. While being on CPS for three more weeks, the patient underwent heart transplantation. Post operative period was complicated by mediastinitis, sternum infection, groin wound infection, sepsis, renal failure, pneumonia and respiratory insufficiency. She was treated by multiple surgical interventions for mediastinitis, groin infection, and sudden femoral artery bleeding. She recovered and was discharged from the hospital after four months. Fifteen months later, control CT scan revealed a 46 mm 23 mm succulent aorta aneurysm close to the right pulmonary artery and superior vena cava (SVC) (Figures 1,2) (2). SVC was stented because of the development of SVC syndrome. The rapid enlargement of aneurysm to 46 mm during three months indicated intervention. Due to her

E556 Ahmad et al. Aortic aneurysms and trans-apical endovascular repair A C B Figure 1 (A) CT scan reveals progressive succulent aneurysm and stented superior vena cava; (B) CT scan shows coronary artery in relation to ascending aneurysm; (C) the arrow shows ascending aneurysm compressing the right pulmonary artery and superior vena cava. Femoral arteries are lacking. Video 1. A 46 mm 23 mm succulent aorta aneurysm on the suture line 15 months after heart transplantation and its relations to the coronary arteries Ostia Khalil Ahmad*, Kim Terp, Gratien Andersen, et al. Department of Cardiothoracic and Vascular Surgery, Institute of Clinical Medicine, Aarhus University Hospital, Aarhus, Denmark Figure 2 A 46 mm 23 mm succulent aorta aneurysm on the suture line 15 months after heart transplantation and its relations to the coronary arteries Ostia (2). Available online: http://www.asvide.com/articles/715 comorbidities and previous complications, open repair approach was considered high risk. We used a custom made investigational ascending aortic stent graft identical in specification to Zenith Ascend Endovascular Graft (ZAEG) to find a safe solution for the treatment of the ascending aortic aneurysm (Figures 3,4) (3). We performed detailed imaging analysis, including 3-D CT scan, obtained aortic branch vessel diameter measurements at multiple landmarks and took length measurements from the highest coronary artery ostia to the origin of brachiocephalic artery along the 3 paths such as the greater curvature, the central line of flow and the lesser curvature. Transfemoral and common carotid artery approaches were not possible. The procedure was performed in a Hybrid operating room under endotracheal anaesthesia and transesophageal echocardiography. The cardiac perfusion team was on stand-by. Axillary/ subclavian approach would be used to go on CPS if necessary. Diagnostic aortography of the ascending aorta was performed through the right brachial artery to demonstrate the sinuses and ostia of the coronary and innominate arteries. The patient was systemically heparinised. A small left anterior thoracotomy, followed by pericardiotomy was performed to expose the left ventricular apex. Pursestring sutures were placed on the

Journal of Thoracic Disease, Vol 7, No 11 November 2015 E557 Deployment sequence A B C Proximal fixation DSR 1 2 3 4 Distal fixation 5 6 7 Fixation of DRS Figure 3 (A) Zenith Ascend Endovascular Graft (ZAEG), designed by Cook Medical Europe, Bjaeverskov, Denmark, consists of a one piece cylindrical graft constructed of woven polyester fabric sewn to self expanding nitinol stents with braided polyester and monofilament polypropylene suture; (B) ZAEG is preloaded onto the Z-Trak Plus Introduction System, which has a soft and flexible tip to decrease ventricular, aortic valve and aortic vessel trauma; (C) proximal and Distal fixation allows for repositioning of the device and the 3 diameter reducing suture (DRS) fixation for deployment accuracy improves deployment accuracy, decreases wind socking and increases stability during deployment. Video 2. Demonstrates patent stent in superior vena cava and ascending aorta, patent coronary and innominate arteries with out sign of endoleak, displacement or aneurysm Khalil Ahmad*, Kim Terp, Gratien Andersen, et al. Department of Cardiothoracic and Vascular Surgery, Institute of Clinical Medicine, Aarhus University Hospital, Aarhus, Denmark Figure 4 Demonstrates patent stent in superior vena cava and ascending aorta, patent coronary and innominate arteries with out sign of endoleak, displacement or aneurysm (3). Available online: http://www.asvide.com/articles/716 apex. The left ventricular apex was punctured between the 2 horizontal 4-0 prolene pursestring sutures by using a 14 gauge needle and the guide wire (cook medical) was advanced to the left ventricle under catheter protection through the ascending aorta and into the aortic arch under echocardiographic and fluoroscopic guidance. Rapid ventricular pacing was performed to minimize pulsatility and distal migration of the endografts during deployment. We deployed two overlapping custom made endovascular stents over the guide wire, (measuring 36±2 and 38±1 mm in diameter, respectively; and each 67±2 mm in length as determined by preoperative CT and angiography under direct fluoroscopic and echocardiography guidance). Post-deployment angiography through the right brachial artery ruled endoleak out, demonstrated a widely patent stent graft, patent coronary and innominate arteries. The apical sutures were secured to achieve haemostasis and finally the minithoracotomy incision was closed. The procedure was uneventful. The patient was extubated in the operating room and was discharged from hospital on the second post-operative day. Control CT scan and echocardiography at 3-, 9-, and 12 months revealed patent stent graft (Figures 5,6). Discussion Conventional treatment for ascending aortic aneurysm or dissection is open repair requiring sternotomy, cardiopulmonary bypass, deep hypothermic circulatory arrest, and selective cerebral perfusion (4) but some patients bear high risks for this major open intervention due to their comorbidities, anatomical challenges, old age, frail condition or multiple previous interventions. They may benefit from a less invasive alternative called endovascular aortic repair (5). Although there has been great innovations in operative techniques, procedural strategies and intensive care management during the last decades, the mortality rate still remains high (6). The 30-day mortality rate is estimated about 5% to 25% in high volume centres (7) Major complications including stroke, renal failure, prolonged ventilation requirement and reoperations occur in 5-10% of patients after elective conventional repair (7). Vascular disease is a problem in heart transplant (HTx)

E558 Ahmad et al. Aortic aneurysms and trans-apical endovascular repair Figure 5 Posterior view: 3-D CT scan reveals stents placed in SVC and ascending aorta. There is no sign of endoleakage. Figure 6 3-D CT scan nine months after endovascular ascending aorta repair (EVAR) without any displacement or aneurysm. candidates and recipients. The prevalence is 6% prior to HTx and 12% post-transplant (5). Prevalence of post HTx abdominal aortic aneurysms is 2-10% with a rupture rate during follow up of 11-38% and a mean aneurismal expansion rate of 0.78±0.41 cm/yr (8). Endovascular repair has been widely adopted for treatment of descending aortic pathologies whereas its role in treating aortic arch and ascending aortic pathologies remains undefined and limited (9). The size, shape, hemodynamic forces, and proximity to other vital structures make ascending aorta zone 0 to EVAR. Currently available stent grafts are designed for the descending and abdominal aorta. They do not fully address the unique features of ascending aortic anatomy (10). The ascending aorta is typically broader in diameter than the descending aorta and because it is a curved structure, there is a significant difference in length along the greater and lesser curves. The anatomic feasibility of endovascular repair of type A aortic dissections has been previously assessed (11,12) The inclusion criteria consist of a proximal sealing zone 20 mm, true lumen diameter 38 mm and total aortic diameter 46 mm, absence of coronary artery bypass grafts from the ascending and no grade 3 or 4 regurgitation (11,12) EVAR is an emerging treatment option. However, patients with aorta-coronary bypass, aortic valve insufficiency, lack of proper sealing zone, and those with connective tissue disorders are not candidates for this type of treatment (1). ZAEG, designed by Cook Medical Europe, Bjaeverskov, Denmark, consists of a one piece cylindrical graft constructed of woven polyester fabric sewn to self-expanding nitinol stents with braided polyester and monofilament polypropylene suture. The stent graft is available in diameters ranging from 28 to 46 mm with a total covered length of 65 mm and total stent length of 83 mm including the bare stents (1) ZAEG is preloaded onto the Z-Trak Plus Introduction System, which has a soft and flexible tip to decrease ventricular, aortic valve and aortic vessel trauma. The anatomical criteria include a minimum 10-mm sealing zone distal to the coronary arteries ostia and proximal to the origin of the innominate artery. The aortic diameter should not be less than 24 mm and greater than 40 mm in size. The long-term performance of endovascular grafts has not yet been established. The patients should be regularly followed-up to assess their health and the performance of their endovascular graft. Vallabhajosyula et al. reported a transapical approach to seal the leak in two cases of aortic pseudo aneurysm with no 30 days mortality and no coronary artery or stent graft related complications.

Journal of Thoracic Disease, Vol 7, No 11 November 2015 E559 Conclusions Endovascular repair of ascending aorta is technically possible and can be performed in selected high risk patients including HTx recipients. The ascending aortic endografts are inadequately designed and until improved technology is available only the patients at highest or prohibitive risks should undergo EVAR. Better results may be achieved with an improved design of ascending aorta specific devices and delivery systems. Acknowledgements The authors thank John Mogensen from Cook Medical Europe for providing the ascending-cmd and drawings; associate prof. Thomas D. Christensen for editing the article. Footnote Conflicts of Interest: The authors have no conflicts of interest to declare. References 1. Oderich GS, Pochettino A, Mendes BC, et al. Endovascular Repair of Saccular Ascending Aortic Aneurysm After Orthotopic Heart Transplantation Using an Investigational Zenith Ascend Stent-Graft. J Endovasc Ther 2015;22:650-4. 2. Ahmad K, Terp K, Andersen G, et al. A 46 mm 23 mm succulent aorta aneurysm on the suture line 15 months after heart transplantation and its relations to the coronary arteries Ostia. Asvide 2015;2:139. Available online: http:// www.asvide.com/articles/715 3. Ahmad K, Terp K, Andersen G, et al. Demonstrates patent stent in superior vena cava and ascending aorta, patent coronary and innominate arteries with out sign of endoleak, displacement or aneurysm. Asvide 2015;2:140. Available online: http://www.asvide.com/articles/716 4. Schoder M, Lammer J, Czerny M. Endovascular aortic arch repair: hopes and certainties. Eur J Vasc Endovasc Surg 2009;38:255-61. 5. Takayama H, Salerno CT, Aldea GS, et al. Characteristics of extracoronary vascular disease in heart transplant recipient. J Card Surg 2008;23:459-63. 6. Tanaka K, Chikazawa G, Sakaguchi T, et al. Hybrid treatment for type A acute aortic dissection with multiorgan malperfusion. Ann Thorac Surg 2014;98:1118-20. 7. Williams JB, Peterson ED, Zhao Y, et al. Contemporary results for proximal aortic replacement in North America. J Am Coll Cardiol 2012;60:1156-62. 8. Dasari T, Heroux A, Peyton M, et al. Abdominal aortic aneurysms (AAA) post heart transplantation: a systematic review of literature. Ann Transplant 2011;16:147-52. 9. Vallabhajosyula P, Gottret JP, Bavaria JE, et al. Endovascular repair of the ascending aorta in patients at high risk for open repair. J Thorac Cardiovasc Surg 2015;149:S144-50. 10. Roselli EE, Idrees J, Greenberg RK, et al. Endovascular stent grafting for ascending aorta repair in high-risk patients. J Thorac Cardiovasc Surg 2015;149:144-51. 11. Huang C, Zhou M, Liu Z, et al. Computed tomographybased study exploring the feasibility of endovascular treatment of type A aortic dissection in the Chinese population. J Endovasc Ther 2014;21:707-13. 12. Sobocinski J, O Brien N, Maurel B, et al. Endovascular approaches to acute aortic type A dissection: a CT-based feasibility study. Eur J Vasc Endovasc Surg 2011;42:442-7. Cite this article as: Ahmad K, Terp K, Andersen G, Hjortdal V. Aortic aneurysms and trans-apical endovascular repair in high risk heart transplant recipient, one year follow up. J Thorac Dis 2015;7(11):E555-E559. doi: 10.3978/j.issn.2072-1439.2015.11.12