Neuro Quiz 25 - Monitoring

Similar documents
Neuro Quiz 29 Transcranial Doppler Monitoring

Nothing to Disclose. Severe Pulmonary Hypertension

Anesthesia Monitoring. D. J. McMahon rev cewood

Chapter 25. General Anesthetics

Capnography. Capnography. Oxygenation. Pulmonary Physiology 4/15/2018. non invasive monitor for ventilation. Edward C. Adlesic, DMD.

June 2011 Bill Streett-Training Section Chief

Neurophysiology Lecture One : Neurophysiology and Evoked Potentials Lecture Two: Clinical Neuroanesthesia

Capnography Connections Guide

NEURO QUIZ 45 EHLERS DANLOS SYNDROME

Capnography: The Most Vital of Vital Signs. Tom Ahrens, PhD, RN, FAAN Research Scientist, Barnes-Jewish Hospital, St. Louis, MO May, 2017

Pharmacokinetics. Inhalational Agents. Uptake and Distribution

Capnography for Pediatric Procedural Sedation Learning Module Last revised: February 18, 2014

Severe Venous Air Embolism Related to Positioning in Posterior Cranial Fossa Surgery in Siriraj Hospital

Shobana Rajan, M.D. Associate staff Anesthesiologist, Cleveland Clinic, Cleveland, Ohio

Intraoperative neurophysiological monitoring for the anaesthetist

Frederic J., Gerges MD. Ghassan E. Kanazi MD., Sama, I. Jabbour-Khoury MD. Review article from Journal of clinical anesthesia 2006.

Chapter 38: Pulmonary Circulation, Pulmonary Edema, Pleural Fluid UNIT VII. Slides by Robert L. Hester, PhD

1. When a patient fails to ventilate or oxygenate adequately, the problem is caused by pathophysiological factors such as hyperventilation.

Anesthesiology in advanced radical surgery. Bruno Carrara Ospedali Riuniti di Bergamo

Decreased Amplitude and Increased Latency in OR Communication During Anterior/Posterior Spinal Fusion

Neuro anesthesia quiz

Capnography- A Review and Renewed Perspective of its Uses and Limitations

Handling Common Problems & Pitfalls During. Oxygen desaturation in patients receiving mechanical ventilation ACUTE SEVERE RESPIRATORY FAILURE

Inhalational Anesthesia. Munir Gharaibeh, MD, PhD, MHPE School of Medicine The University of Jordan February, 2018

Patient Management Code Blue in the CT Suite

Essentials of Anaesthetic Monitoring in Veterinary Practice

End tidal carbon dioxide (ETCO2) and peripheral pulse oximetry (SpO2) trends and right-to-left shunting in neonates undergoing

1- Prone position implications: Most spine cases are performed with the patient in the

Introduction and Overview of Acute Respiratory Failure

Non-Invasive Assessment of Respiratory Function. Chapter 11

Cardiovascular Effects of Anesthesia for Cesarean Delivery in the Cardiac Patient

HIGH DOSE STREPTOKINASE FOR THROMBOLYSIS IN THE IMMEDIATE POSTOPERATIVE PERIOD: A CASE REPORT

Capnography 101. James A Temple BA, NRP, CCP

Anaesthetic considerations for laparoscopic surgery in canines

3/30/12. Luke J. Gasowski BS, BSRT, NREMT-P, FP-C, CCP-C, RRT-NPS

How it Works. CO 2 is the smoke from the flames of metabolism 10/21/18. -Ray Fowler, MD. Metabolism creates ETC0 2 for excretion

Capnography (ILS/ALS)

Inhalation anesthesia. Somchai Wongpunkamol,MD Anes., CMU

3. Which of the following would be inconsistent with respiratory alkalosis? A. ph = 7.57 B. PaCO = 30 mm Hg C. ph = 7.63 D.

General anesthesia. No single drug capable of achieving these effects both safely and effectively.

Maternal and Fetal Physiology

Anesthesia Final Exam

Resuscitation Science Update. Jennifer K. Lee, MD Johns Hopkins University Department of Anesthesia Division of Pediatric Anesthesia

November 2012 Critical Care Case of the Month: I Just Can t Do It Captain! I Can t Get the Sats Up!

NEUROMONITORING AND ANESTHESIA CONSIDERATIONS. Martha Richter, MSN, CRNA

Arterial Blood Gases. Dr Mark Young Mater Health Services

EMS System for Metropolitan Oklahoma City and Tulsa 2017 Medical Control Board Treatment Protocols

ISPUB.COM. Review Of Currently Used Inhalation Anesthetics: Part II. O Wenker SIDE EFFECTS OF INHALED ANESTHETICS CARDIOVASCULAR SYSTEM

This quiz is being published on behalf of the Education Committee of the SNACC.

Capnography: The Most Vital Sign

M5 BOARD REVIEW. Q s. Q s. Q s. Q s. Q s. Equations. Be Brilliant Today. Respiratory ( ) Alveolar Gas Equation. Dead Space (Bohr Equation)

CEREBRAL PHYSIOLOGY CEREBRAL PHYSIOLOGY REGULATION OF CBF REGULATION OF CBF REGULATION OF CBF. Cerebral Blood Flow (CBF)

Anesthesia of robotic thoracic surgery

Foundation in Critical Care Nursing. Airway / Respiratory / Workbook

On behalf of the education Committee of the SNACC

ECT Workshop. Rahul Bajekal Consultant Anaesthetist Newcastle upon Tyne 23 November 2017

Pulmonary Hypertension Perioperative Management

HST-151 Clinical Pharmacology in the Operating Room

بسم هللا الرحمن الرحيم

Omar Sami. Mustafa Khader. Yanal Shafaqouj

General Anesthesia. Mohamed A. Yaseen

Pneumoperitoneum. Laparoscopic instrumentation Access into the abdomen

Information Often Given to the Nurse at the Time of Admission to the Postanesthesia Care Unit

Major Aortic Reconstruction; Cerebral protection and Monitoring

Study Of Effects Of Varying Durations Of Pre-Oxygenation. J Khandrani, A Modak, B Pachpande, G Walsinge, A Ghosh

Title: Mayday! Acute Loss of Signals with Sky Rocketing Elevation of Liver Enzymes Celiac Artery in Danger During Spine Distraction

Case Presentation: Anesthetic Management For POEM Procedure in a Patient with Severe Pulmonary Hypertension CHUCK STRAUBHAAR BSN, SRNA

Don t let your patients turn blue! Isn t it about time you used etco 2?

How to maintain optimal perfusion during Cardiopulmonary By-pass. Herdono Poernomo, MD

Hypoxemia post Liver-Transplantation for Hepatopulmonary Syndrome

Effect of anaesthetic use of nitrous oxide on carbon dioxide elimination in laparoscopic surgery

Pharmacology: Inhalation Anesthetics

ANESTHESIA EXAM (four week rotation)

Pulmonary Problems of the Neonate. Jon Palmer, VMD, DACVIM Chief, Neonatal Intensive Care Service New Bolton Center, University of Pennsylvania, USA

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018

Guidelines Administrative Practice X Clinical Practice Professional Practice

OXYGENATION AND ACID- BASE EVALUATION. Chapter 1

Respiratory Physiology Part II. Bio 219 Napa Valley College Dr. Adam Ross

Dr Brigitta Brandner UCLH

Oxygenation. Chapter 45. Re'eda Almashagba 1

Subspecialty Rotation: Anesthesia

Pathophysiology: Left To Right Shunts

Neurophysiology Lecture One : Neurophysiology and Evoked Potentials Lecture Two: Clinical Neuroanesthesia

BASIC CONCEPT ON PEDIATRIC NEUROANESTHESIA INASNACC

a. Describe the physiological consequences of intermittent positive pressure ventilation and positive end-expiratory pressure.

General Anesthesia. My goal in general anesthesia is to stop all of these in the picture above (motor reflexes, pain and autonomic reflexes).

a central pulse located at the apex of the heart Apical pulse Apical-radial pulse a complete absence of respirations Apnea

SHOBANA RAJAN, M.D, STAFF ANESTHESIOLOGIST CLEVELAND CLINIC, OHIO QUIZ TEAM ; SUNEETA GOLLAPUDY, VERGHESE CHERIAN, ANGELE MARIE THEARD.

Pathophysiology: Left To Right Shunts

They aren t the same thing. Daniel Dunham

Quiz 39. This quiz is being published on behalf of the Education Committee of the SNACC. Start. Hepatic disease and neuroanesthesia

Guidelines for the Anesthetic Management of Spine Fusions and SSEP Monitoring. Vinit Wellis, M.D.

Index. Note: Page numbers of article titles are in boldface type.

Topics to be Covered. Cardiac Measurements. Distribution of Blood Volume. Distribution of Pulmonary Ventilation & Blood Flow

poor compliance and houses important structures such as the brainstem and

3. D Objective: Chapter 4, Objective 4 Page: 79 Rationale: A carbon dioxide level below 35 mmhg indicates hyperventilation.

Nitric Resource Manual

Blood Brain Barrier (BBB)

Perioperative management of a patient with left ventricular failure

Alessandro Della Puppa

Transcription:

Neuro Quiz 25 - Monitoring This quiz is being published on behalf of the Education Committee of the SNACC Verghese Cherian, MD, FFARCSI Penn State Hershey Medical Center, Hershey, PA Quiz Team Shobana Rajan, M.D Suneeta Gollapudy, M.D Angele Marie Theard, M.D START

1. Which of the following monitor is NOT used to measure Oxygen A. Paramagnetic analyzer B. Galvanic cell analyzer C. Polarographic sensor D. Infrared gas analyzer E. Clark electrode Next Question

1. A. Paramagnetic analyzer Oxygen, because of its unpaired electron in the outer orbit, is paramagnetic or attracted towards a magnetic field This is the most common principle used to measure oxygen in the inspired and expired gases in the anesthesia machine Nitric oxide is also paramagnetic, while most other anesthetic gases are weakly attracted into a magnetic field. Nitrogen is diamagnetic or repelled from a magnetic field

1. B. Galvanic cell analyzer The Galvanic, Hersch or the Fuel cell are similar to the polarographic sensor, but the electrodes are chosen to provide their own current The cathode is often gold or silver, and the anode is usually lead, with potassium hydroxide as the electrolyte solution 2Pb + 6OH - =2PbO 2 H - + 2H 2 O + e - The flow of electrons is proportional to the concentration of oxygen present

1. C. Polarographic sensor The Polarographic (Clark) Oxygen electrode can measure partial pressure of oxygen in blood or a gas sample The Teflon membrane allows the oxygen tension in the blood to equilibrate with the electrolyte solution

1. D. Infrared gas analyzer Molecules with two or more dissimilar atoms absorb infrared (IR) radiation and different molecules have distinct IR absorption spectra This technique is used to measure CO 2 and anesthetic gases Oxygen, nitrogen, helium, xenon, and argon do not absorb IR radiation and cannot be measured by this technique Back to Question Next Question

1. E. Clark electrode The Clark electrode is the same as Polarographic sensor It can measure partial pressure of oxygen in blood or a gas sample The Teflon membrane allows the oxygen tension in the blood to equilibrate with the electrolyte solution

2. After induction of a 2y old for craniofacial advancement, a 22G was inserted into the left radial artery for pressure monitoring and the transducer was fixed at the foot end of the table and zeroed. During surgery, the table was placed in reverse Trendelenburg with the transducer 10cm below the heart level of the child. Which of the following is TRUE? A. Recorded pressure will be 10mmHg higher than true pressure B. Recorded pressure will be 10mmHg lower than true pressure C. Recorded pressure will be 7.5mmHg higher than true pressure D. Recorded pressure will be same as the true pressure E. The transducer has to be re-zeroed 10cm transducer Next Question

2. A. Recorded pressure will be 10mmHg higher than true pressure Since, the transducer is located 10 cm below the level of the patient s heart, there is a 10 cm H 2 O fluid column from the level Phlebostatic axis of the patient s heart to the transducer 10cm This will cause the pressure transducer reading from the transducer system to read approximately 7.5 mmhg higher (NOT 10mmHg) than the true arterial pressure

2. B. Recorded pressure will be 10mmHg lower than true pressure Since, the transducer is located 10 cm below the level of the patient s heart, there is a 10 cm H 2 O fluid column from the level of the patient s heart to the transducer This will cause the pressure reading from the transducer system to read approximately 7.5 mmhg higher (NOT 10mmHg & lower ) than the true arterial pressure 10cm Phlebostatic axis transducer

2. C. Recorded pressure will be 7.5mmHg higher than true pressure Since, the transducer is located 10 cm below the level of the patient s heart, there is a 10 cm H 2 O fluid column from the level of the patient s heart to the transducer This will cause the pressure reading from the transducer system to read approximately 7.5 mmhg higher than the true arterial pressure Back to Question 10cm Phlebostatic axis transducer Next Question

2. D. Recorded pressure will be same as the true pressure Since, the transducer is located 10 cm below the level of the patient s heart, there is a 10 cm H 2 O fluid column from the level of the patient s heart to the transducer This will cause the pressure reading from the transducer system to read approximately 7.5 mmhg higher (NOT same) than the true arterial pressure 10cm Phlebostatic axis transducer

2. E. The transducer has to be re-zeroed The transducer is zeroed to the atmospheric pressure and since it was just done, there is no need to re-zero it However, to get the correct pressure reading, the transducer can be raised to the Phlebostatic axis. 10cm Phlebostatic axis transducer In a sitting position if the transducer is placed at the level of the tragus to measure the pressure at the level of the circle of Willis, the measured pressure will be 15 mmhg lower (~20cm higher) than the actual pressure

3. Which of the following monitors is the LEAST sensitive to detect Venous Air Embolism A. Trans-Esophageal Echocardiography B. Doppler sensor C. Capnography D. Pulmonary artery pressure E. ECG changes Next Question

3. A. Trans-Esophageal Echocardiography Trans-Esophageal Echocardiography (TEE) is the most sensitive monitor to detect venous air embolism (VAE) It can also identify right to left shunting of air in the presence of a patent foramen ovale However, its safety with prolonged use, especially with neck flexion is not well established

3. B. Doppler sensor Although, the standard of care to detect VAE is a precordial Doppler probe, placed over left or right parasternal, between 2nd and 3rd ribs, it is less sensitive than the TEE An audible, continuous mill-wheel murmur is indicative of VAE It can detect VAE before any physical signs are evident

3. C. Capnography Although, ET CO 2 monitoring is part of standard of care, it is not the most sensitive to detect VAE, nor is it specific Presence of VAE causes regional blockade of pulmonary circulation leading to an increase in alveolar deadspace resulting in decrease in ETCO 2 and an increased arterial-et CO 2 gradient A sudden rise in ET Nitrogen is also a sign of air embolism, but is usually short-lasting but can differentiate between air and thrombo- embolism

3. D. Pulmonary Artery Pressure A rise in pulmonary artery pressure will occur with significant venous air embolism and its sensitivity matches changes in ETCO 2 These are the earliest, apparent physiological changes

3. E. ECG changes Significant VAE is manifest as RV strain pattern and ST depression on the ECG and they manifest along with hemodynamic instability VAE can occur during posterior fossa surgery (sitting position), cervical laminectomy, craniosynostosis procedure, cesarean section during uterine exteriorization Back to Question Next Question

4. During an intracranial surgery, in response to a sudden hemorrhage, the anesthesiologist increased the FIO 2 from 0.4 to 0.7. It was noted that the ETCO 2 dropped from 38 to 29 mmhg, while the PaCO 2 on the arterial blood was 40 mmhg. The likely cause for this increased PaCO 2 -ETCO 2 gradient could be any of the following, EXCEPT: 1. Venous Air Embolism 2. Hypotension 3. Low cardiac output 4. Increased FIO 2 5. Hyperventilation Next Question

4. A. Venous Air Embolism An (arterial-et)pco 2 is an index of alveolar dead space (normal value - 2-5 mm Hg) Common cause for intra-operative rise in alveolar dead space are reduced pulmonary blood flow Pulmonary embolism (air, thrombus) Hypotension Low cardiac output

4. B. Hypotension An (arterial-et)pco 2 is an index of alveolar dead space (normal value - 2-5 mm Hg) Common cause for intra-operative rise in alveolar dead space are reduced pulmonary blood flow Pulmonary embolism (air, thrombus) Hypotension Low cardiac output

4. C. Low cardiac output An (arterial-et)pco 2 is an index of alveolar dead space (normal value - 2-5 mm Hg) Common cause for intra-operative rise in alveolar dead space are reduced pulmonary blood flow Pulmonary embolism (air, thrombus) Hypotension Low cardiac output

4. D. Increased FIO 2 An (arterial-et)pco2 is an index of alveolar dead space (normal value - 2-5 mm Hg) High FIO 2 preferentially vasodilates well perfused alveoli, resulting in the redistribution of blood flow away from poorly perfused alveoli causing increased alveolar dead space BJA 2011; 107: 631

4. E. Hyperventilation Hyperventilation can reduce ETCO 2 but will also reduce the arterial PCO 2, thus maintaining the arterial- ET CO 2 gradient In the given scenario, an increased (a-et) CO 2 can result from any of the other options Back to Question Next Question

5. Which of the following statements regarding intra-op evoked potential (EP) monitoring is TRUE? A. Equipotent doses of Inhalational and intravenous anesthetics suppress EP equally B. Brainstem Auditory EP (BAEP) are very sensitive to inhalational anesthetics C. If motor evoked potentials are planned, muscle relaxants should not be used for intubation D. Opioids and benzodiazepine have negligible effects on EP recordings E. If intraoperative motor EP is planned, up to 50% nitrous oxide is acceptable

5. A. Equipotent doses of Inhalational and intravenous anesthetics suppress EP equally Inhalational anesthetic agents have more depressant effects on EP compared to IV agents and addition of nitrous oxide makes it worse MEP are exquisitely sensitive to inhalational agents and are best avoided or should be <0.5MAC, if it is used

5. B. Brainstem Auditory EP (BAEP) are very sensitive to inhalational anesthetics While short latency brainstem and spinal EP are resistant to the effects of anesthetic longlatency, cortical EP are sensitive to anesthetic agents BAEP are not sensitive to anesthetics and can be monitored under anesthesia

5. C. If motor evoked potentials are planned, muscle relaxants should not be used for intubation Although, monitoring of MEP precludes the use of muscle relaxants, its use for endotracheal intubation is not contraindicated if its effect wears off before the surgery and monitoring begins MEP are exquisitely sensitive to inhalational agents and are best avoided or should be <0.5MAC, if it is used TIVA is the preferred technique for MEP

5. D. Opioids and benzodiazepine have negligible effects on EP recordings Opioids and benzodiazepines have negligible effects on EP monitoring TIVA Dexmedetomidine (0.2-0.5mcg/kg/h) Remifentanil (0.05-0.3mcg/kg/m) Propofol (25-150mcg/kg/m) Ketamine and Etomidate does not affect EP monitoring Back to Question References

5. E. If intraoperative motor EP is planned, up to 50% nitrous oxide is acceptable Inhalational agents have more depressant effects on EP compare to IV agents and addition of nitrous oxide makes it worse

References Langton JA, Hutton A. Respiratory gas analysis. CEACCP 2009; 9: 19-23 Miller, RD et al. Miller s Anesthesia, 7th ed, Churchill Livingstone: Chapter 63 Yamauchi, et al. Dependence of the gradient between arterial and end-tidal PCO2 on the fraction of inspired oxygen. BJA 2011; 107 : 631 Back to Question 1 2 3 4 5