Diagnosis of Vertebral Artery Ostial Stenosis on Contrast-Enhanced MR Angiography: Usefulness of a Thin-Slab MIP Technique

Similar documents
Magnetic Resonance Angiography

Seonmun Kim, Sungwon Lee, Hyun Seok Choi, So-Lyung Jung, Kook-Jin Ahn, Bum-soo Kim

Contrast material enhanced threedimensional

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA

MR Advance Techniques. Vascular Imaging. Class II

Anatomic Evaluation of the Circle of Willis: MR Angiography versus Intraarterial Digital Subtraction Angiography

Endovascular treatment of intracranial aneurysms with detachable

Department of Radiology University of California San Diego. MR Angiography. Techniques & Applications. John R. Hesselink, M.D.

1Pulse sequences for non CE MRA

Neuroradiology MR Protocols

Overestimation of carotid artery stenosis with magnetic resonance angiography compared with digital subtraction angiography

Original Research Article. Hale Aydin 1 *, Agildere A. Muhtesem 2

Time-of-Flight MR Angiography of Carotid Artery Stenosis: Does a Flow Void Represent Severe Stenosis?

3D time-of-flight (3D TOF) MR angiography (MRA)

Stroke is a common and serious disorder, with an annual incidence

Non-Invasive Follow-up Evaluation of Post-Embolized AVM with Time-Resolved MRA: A Case Report

Surface Appearance of the Vertebrobasilar Artery Revealed on Basiparallel Anatomic Scanning (BPAS) MR Imaging: Its Role for Brain MR Examination

There are many methods to quantify carotid stenosis. 1 With

Postoperative Assessment of Extracranial Intracranial Bypass by Time- Resolved 3D Contrast-Enhanced MR Angiography Using Parallel Imaging

Cerebral MR Venography: Normal Anatomy and Potential Diagnostic Pitfalls

Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms

Yu-Chun Lin, RT; Shu-Hang Ng, MD; Jian-Chuan Chen, MS; Alex Mun-Ching Wong, MD; Yau-Yau Wai, MD

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

Current high-speed, multidetector CTA techniques allow

Evaluation of Intracranial Vasculatures in Healthy Subjects with Arterial-Spin-Labeling-Based 4D-MR Angiography at 3T

Renal artery stenosis (RAS) evaluation with Nonenhanced MR Angiography.

Methods. Yahya Paksoy, Bülent Oğuz Genç, and Emine Genç. AJNR Am J Neuroradiol 24: , August 2003

Evaluation of Carotid Vessels and Vertebral Artery in Stroke Patients with Color Doppler Ultrasound and MR Angiography

Craniocervical artery dissection (CCAD) is the most common

Two cases of spontaneous middle cerebral arterial dissection causing ischemic stroke

Time-Of-Flight MRA. Faculty Disclosures Vincent B. Ho, M.D. Presentation Objectives. MRA Techniques. Pros and Cons of MRA

Research Article Carotid Artery Stenosis: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography at 3T

Arteriosclerotic changes at the extracranial carotid bifurcation

Contrast-Enhanced Magnetic Resonance Angiography of Carotid Arteries. Utility in Routine Clinical Practice

Original Research. Tadateru Sumi, DDS, 1 Misa Sumi, DDS, PhD, 1 Marc Van Cauteren, PhD, 2 Yasuo Kimura, DDS, PhD, 1 and Takashi Nakamura, DDS, PhD 1 *

Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

doi: /brain/awp026 Brain 2009: 132;

Field Strength. Regional Perfusion Imaging (RPI) matches cerebral arteries to flow territories

Accuracy of Contrast-Enhanced MR Angiography in Predicting Angiographic Stenosis of the Internal Carotid Artery: Linear Regression Analysis

ROLE OF CONTRAST ENHANCED MR ANGIOGRAPHY IN AORTIC COARCTATION

Localization and Treatment of Unruptured Paraclinoid Aneurysms: A Proton Density MRI-based Study

Detectability of unruptured intracranial aneurysms on thinslice non-contrast-enhanced CT

Magnetic Resonance Imaging. Basics of MRI in practice. Generation of MR signal. Generation of MR signal. Spin echo imaging. Generation of MR signal

RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE

Carotid Imaging. Dr Andrew Farrall. Consultant Neuroradiologist

Carotid MR angiography with traditional bolus timing: clinical observations and Fourier-based modelling of contrast kinetics

Modified Oblique Sagittal Magnetic Resonance Imaging of Rotator Cuff Tears: Comparison with Standard Oblique Sagittal Images

Speed, Comfort and Quality with NeuroDrive

The Use and Pitfalls of Intracranial Vessel Wall Imaging: How We Do It 1

NIH Public Access Author Manuscript J Vasc Interv Radiol. Author manuscript; available in PMC 2012 July 1.

MR angiography. Extracranial MR angiography. Andrew G Clifton. Department of Neuroradiology, Atkinson Morley's Hospital, London, UK

High-Spatial-Resolution 3D Balanced Turbo Field-Echo Technique for MR Angiography of the Renal Arteries: Initial Experience 1

Tips and Tricks of State of the art MRA

S pontaneous dissection of the internal

MR imaging at 3.0 tesla of glossopharyngeal neuralgia by neurovascular compression

Role of multislice CT in assessment of carotid stenosis. Mohammad Sobhi Hassan, Mohsen Gomaa hassan. Departement of radiology, Ainshams University.

The ejournal of the European Society of Minimally Invasive Neurological Therapy

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Subclavian steal syndrome: an underdiagnosed disease

Role of the Radiologist

Subtraction Helical CT Angiography of Intra- and Extracranial Vessels: Technical Considerations and Preliminary Experience

stenosis, and is effective in screening of significant stenosis of both extracranial and intracranial arterial stenosis.

c o m p l e t e agenesis of Acom agenesis of A 1 asymmetric A 1 (no agenesis)

Intracranial MR Angiography: Its Role in the Integrated Approach to Brain Infarction

Blunt Carotid Injury- CT Angiography is Adequate For Screening. Kelly Knudson, M.D. UCHSC April 3, 2006

A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla

Carotid Artery Stenosis: Optimization of CT Angiography with a Combination of Shaded Surface Display and Source Images

Raja Muthupillai, PhD. Department of Diagnostic and Interventional Radiology St. Luke s Episcopal Hospital. Research Support: Philips Healthcare

High-Sensitivity Coil Array for Head and Neck Imaging: Technical Note

ORIGINAL CONTRIBUTION

Department of Radiology, Division of MRI, University of Michigan, 1500 E. Medical Center Drive, Ann Arbor, MI , USA

The ejournal of the European Society of Minimally Invasive Neurological Therapy

Extracranial Carotid Arteries: Evaluation with Black Blood MR Angiography

How does the degree of carotid stenosis avect the accuracy and interobserver variability of magnetic resonance angiography?

Methods of Counting Ribs on Chest CT: The Modified Sternomanubrial Approach 1

Multisection CT Angiography Compared with Catheter Angiography in Diagnosing Vertebral Artery Dissection

NEUROVASCULAR ANATOMY

Contrast-enhanced magnetic resonance angiography in carotid artery disease: does automated image registration improve image quality?

Non-Contrast MRA. How and When 1996! Why Non-Contrast MRA? Angiography: What are our goals? Inflow Techniques Differences in excitation hx

B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with 64-MD-CT Angiography

Variations of the cerebellar arteries at CT angiography

MR Angiography in the evaluation of Lower Extremity Arterial Disease

3D high-resolution MR imaging can provide reliable information

Melissa M Ong 1*, Katharina Hausotter 1, Lothar R Pilz 2, Stefan O Schoenberg 1 and Henrik J Michaely 1

The study of local hemodynamics within anatomically complex

The introduction of multisection CT (MSCT) has led to a

perform carotid endarterectomy on the basis Magnetic resonance angiography is a new G R Young, P R D Humphrey, M D M Shaw, T E Nixon, E T S Smith

Plaque Shift vs. Carina Shift Prevalence and Implication

Advanced Vascular Imaging: Pulsatile Tinnitus. Disclosures. Pulsatile Tinnitus: Differential Diagnosis. Pulsatile Tinnitus

MR Imaging of Atherosclerotic Plaques

Ischemic stroke is the most common cause of disability in

Basilar Artery Plaque and Pontine Infarction Location and Vascular Geometry

Procedia - Social and Behavioral Sciences 159 ( 2014 ) WCPCG 2014

Dynamic 3D MR Angiography of Intra- and Extracranial Vascular Malformations at 3T: A Technical Note

ABSTRACT INTRODUCTION

MR Imaging with the CCSVI or Haacke protocol

Pre-and Post Procedure Non-Invasive Evaluation of the Patient with Carotid Disease

Comparative study of carotiddoppler with contrast enhanced MRA in patients with stroke

Three-Dimensional Rotational Angiography of Neurovascular Lesions in Pediatric Patients

Transcription:

Diagnosis of Vertebral Artery Ostial Stenosis on Contrast-Enhanced MR Angiography: Usefulness of a Thin-Slab MIP Technique Sun Mi Kim 1, Deok Hee Lee 2 Jin Woo Choi 3, Byung Se Choi 4, Hyun Sin In 5 It is a well-known clinical fact that contrast-enhanced magnetic resonance angiography exaggerates vertebral arterial ostial stenosis and sometimes shows pseudostenosis. Considering the clinical significance of a lesion in the posterior circulation ischemia, the importance of an accurate imaging diagnosis of ostial stenosis should not be underestimated. We were able to differentiate pseudostenosis of the ostium from true stenosis using thin-slab maximum-intensity-projection(mip) images which are thought to be helpful for minimizing standard full thickness MIP images. Index words : Vertebral artery ostial stenosis Contrast-enhanced MRA Thin-slab MIP technique Introduction Contrast-enhanced magnetic resonance angiography (CE-MRA) is a highly sensitive technique used to detect cervical artery stenosis; it has become part of the routine imaging for detecting brain stroke as well as atherosclerotic diseases (1-4). This technique produces arterial images with high-spatial resolution and which are free from the flow-related artifacts of time-of-flight (TOF) MRA. However, owing to the technical limitations of the currently available CE-MRA technique, there are numerous disadvantages including an image acquisition timing issue, its relatively low spatial resolution, overestimation of the degree of stenosis, etc. It has been suggested that the relatively low spatial resolution and inherent limitations of the maximum-intensity-projection (MIP) technique are responsible for the overestimation of a certain stenosis in CE-MRA. Pseudostenosis of the vertebral artery (VA) JKSMRM 15:77-81(2011) 1 Department of Radiology, Kyung Hee University Hospital-Gangdong, School of Medicine, Kyung Hee University, Seoul, Korea 2 Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea 3 Department of Radiology, Konkuk University Hospital, Konkuk University School of Medicine, Seoul, Korea 4 Department of Radiology, Seoul National University Bundang Hospital, Korea 5 Department of Radiology, Busan Paik Hospital, Inje University College of Medicine, Busan, Korea Received; October 28, 2010, revised; April 13, 2011, accepted; April 14, 2011 Corresponding author : Deok Hee Lee, M.D., Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 86 Asanbyeongwon-gil, Songpa-gu, Seoul 138-736, Korea. Tel. 82-2-3010-5944 Fax. 82-2-476-0090 E-mail: dhlee@amc.seoul.kr - 77-

Sun Mi Kim et al ostium is also one of the common problems encountered when using this technique which may exaggerate preexisting focal stenosis of the ostium or show a false stenosis of an otherwise intact vessel (3, 5). It has been reported that lesion overestimation is seen in 15% of cases (3). Although the mechanism of the pseudostenosis is not well understood, it is said that turbulent flow in the particular anatomic region causes intravoxel signal dephasing which results in decreased signal intensity. Because of the difference in the signal intensity of the ostial region from that of the other segments of the VA, this particular region appear stenotic on 3-dimensional (3D), full-thickness MIP images (MIP artifact). Recent improvement of the image quality has decreased this problem, however, it is still a frequently seen phenomenon with the current imaging techniques. As we found that thin-slab (slab thickness of 1~2 mm) MIP was very helpful for minimizing the MIP artifact, we began to apply this simple method for every lesion noted on routine MIP images. The purpose of this short technical report is to present our method of applying the thin-slab MIP technique, as it is very helpful for minimizing pseudostenosis of the VA os. Technique MR imaging was performed on a 3.0-T MR system (Gyroscan Intera Achieva, Philips Medical System, The Netherlands) equipped with a neurovascular head and neck coil. High-spatial-resolution 3D CE-MRA was obtained in the coronal plane using a fast-field, gradient-echo sequence together with the contrastenhanced timing robust angiography (CENTRA) k- space acquisition technique which is a modified centric k-space ordering technique. The sequence was performed with 200 coronal partitions, each with a 0.45-mm slice thickness, 5/2 msec [TR/TE], 3 NEX, 30 flip angle, 320-mm 3 field of view according to a 512 512 image matrix, factor 3 sensitivity encoding (SENSE), and an imaging time of 69 seconds. Reconstruction was performed without zero filling. The spatial resolution was 0.63 0.63 0.90 mm 3. Breathholding was not used. The contrast material (Dotarem [0.5 mmol/ml], Laboratoire Guerbet, Aulnay-su-Bois, France) was infused by a 22-gauge venous angiocatheter via the antecubital fossa by using a Medrad Spectris Solaris MR Injection System (USA). 0.2 milliliters/ kg of contrast material was injected at a a b c Fig. 1. (a) Oblique digital subtraction angiography image. (b) Oblique gadolinium-enhanced sagittal thick (40-mm) MR angiography. (c) Thin-slab MIP (slab thickness of 1 mm) image. Digital subtraction andgiography and MR angiography show concordant results of severe ostial stenosis (arrow) of the left VA. The thin-slab MIP image shows no signal in the left VA os. This case represents true VA ostial stenosis. - 78-

Diagnosis of Vertebral Artery Ostial Stenosis on Contrast-Enhanced MR Angiography rate of 2 ml/sec. Each bolus was immediately followed by a 20-mL saline flush. For the routine MRA image display, the images were post-processed on a ViewForum workstation (Philips Medical System, The Netherlands). Post-processing sub-volumes were generated using the MR postprocessing console to create 15, maximum-intensityprojection (MIP) images at 12 increments each on both the horizontal and vertical axes. MRA source images were temporarily stored in a mini-pacs system (TeraRecon, San Mateo, CA). When any arterial lesion was seen on the routine projections, a radiologist generated reformatted images using the source images archived on the mini-pacs system. We used a PC-based, 3D image processing software (Aquarius NET 1.8.2.6 ; TeraRecon, San Mateo, CA). When there was any stenosis at the VA os, we re-evaluated the degree of stenosis using thin-slab MIP images (slab thickness of 1~2 mm) with variable direction and which followed the course-of VA from the os to the proximal VA. A radiologist performed a qualitative analysis comparing the images of the VA ostial stenosis with MR angiogram and digital subtraction angiography (DSA). With this interactive review of the stenosis, we could ascertain whether the stenosis was true or false as can be seen in Figures 1 and 2. Discussion In the posterior circulation, evaluation of clinically relevant stenosis remains difficult with MR angiography, primarily because of the small diameter of the vertebral arteries and the frequent anatomic variations with variable direction. Randoux et al. reported that MR angiography was a useful method to rule out ostial stenosis of the craniocervical vessels except vertebral artery. They observed that 15% of VA os stenosis was misclassified due to overestimation of the stenosis and that the positive predictive values of MRA for VA os stenosis greater than 50% was 58% (3). We thought that the possible reason for the MIP artifact in that specific region was regional low signal intensity of the VA os which was probably caused by the intravoxel dephasing phenomenon (4, 6). The cause of intravoxel dephasing is not yet well understood. This phenomenon is due to the spin dephasing when the voxel size is comparable to the residual lumen at level of stenosis (7). In addition to, previous studies were explained that turbulent flow in the axilla area of a a b c Fig. 2. (a) The findings on oblique gadolinium-enhanced MR angiography shows a loss of signal in the right VA os, which is considered to represent severe stenosis. (b) Thin-slab MIP (slab thickness of 1 mm) image shows a mild signal defect (arrowhead) in the right VA os and intact luminal patency of the right VA os. (c) Oblique DSA image shows no significant VA stenosis. Using the thin-slab MIP image, we were able to differentiate the pseudostenosis from true stenosis of the right VA os. - 79-

Sun Mi Kim et al small vessel may cause an intravoxel dephasing, especially at a broad bifurcation angle (8, 9). To reduce the intravoxel dephasing effect, we have to obtain the CE-MRA using a smaller voxel size, but does not yield in a stenosis grading improvement (7). Also, thick slab MIP image can lead to overestimate stenoses because of partial volume averaging effect (10). Because of the frequent exaggeration of stenosis in this area, we tend to underestimate the apparent stenosis of VA os in our daily clinical practice. However, considering the high incidence of the VA origin of atherosclerotic disease, as was observed in the New England Medical Center Posterior Circulation Registry (NEMC-PCR) (131 of 407, 32%) and the frequent association of posterior circulation infarction and significant stenosis of the VA os, we must give more attention to this lesion (11). For these reasons, VA os stenosis was overestimated on MIP images of CE- MRA. Therefore, we tend to underestimate the degree of VA os stenosis in our daily clinical practice. However, VA os stenosis (> 50%) is very common and is attributable to artery-to-artery emboli in the NEMC- PCR If we consider the tendency toward exaggeration on CE-MRA, we may neglect a significant source of incorrectly diagnosed VA os stenosis. However, performing digital subtraction angiography is not a good clinical option simply for confirmation of possible stenosis as this procedure can have distinct negative ramifications (12). Considering these problems, review of source images also required additional access to the special PACS image data serve system. But, a simple, PC-based review of a lesion using a thin-slab MIP technique is very helpful in order to both minimize possible exaggeration of the stenosis on images as well as the potential clinical underestimation of a possible, existing stenosis. CNR of vessels on MIP images decrease with increasing background signal intensity and reduce vessel size. Thin-slap MIP image can be effect, as it leads to minimize inclusion of background tissue into the slab (10). So, thin-slab MIP image will be beneficial to stenosis grading, so as to include as few voxels as possible in the slab. Also, it is possible to represent a vessel with different orientation. However, differentiation of VA ostial stenosis was not always possible because of the technical limitations of the technique in some patients. It is very difficult to determine the degree of stenosis if the signal-to-noise ratio is too low and this is not uncommon in those regions. Tracing the course of a very tortuous, proximal VA is sometimes quite difficult. Conclusion A PC-based, thin-slab MIP reconstruction technique is useful for differentiating true stenosis from pseudostenosis of the VA ostia. References 1.Kollias SS, Binkert CA, Ruesch S, Valavanis A. Contrastenhanced MR angiography of the supra-aortic vessels in 24 seconds: a feasibility study. Neuroradiology 1999;41:391-400 2.Phan T, Huston J, 3rd, Bernstein MA, Riederer SJ, Brown RD Jr. Contrast-enhanced magnetic resonance angiography of the cervical vessels: experience with 422 patients. Stroke 2001;32:2282-2286 3.Randoux B, Marro B, Koskas F, Chiras J, Dormont D, Marsault C. Proximal great vessels of aortic arch: comparison of three-dimensional gadolinium-enhanced MR angiography and digital subtraction angiography. Radiology 2003;229:697-702 4.Remonda L, Senn P, Barth A, Arnold M, Lovblad KO, Schroth G. Contrast-enhanced 3D MR angiography of the carotid artery: comparison with conventional digital subtraction angiography. AJNR Am J Neuroradiol 2002;23:213-219 5.Leclerc X, Martinat P, Godefroy O, et al. Contrast-enhanced three-dimensional fast imaging with steady-state precession (FISP) MR angiography of supraaortic vessels: preliminary results. AJNR Am J Neuroradiol 1998;19:1405-1413 6.Slosman F, Stolpen AH, Lexa FJ, et al. Extracranial atherosclerotic carotid artery disease: evaluation of nonbreath-hold three-dimensional gadolinium-enhanced MR angiography. AJR Am J Roentgenol 1998;170:489-495 7.Cosottini M, Calabrese R, Puglioli M, et al. Contrast-enhanced three-dimensional MR angiography of neck vessels: does dephasing effect alter diagnostic accuracy? Eur Radiol 2003;13:571-581 8.Chung TS, Lee YJ, Kang WS, et al. Clinical and experimental investigation of pseudoaneurysm in the anterior communicating artery area on 3-dimensional time-of-flight cerebral magnetic resonance angiography. J Comput Assist Tomogr 2004;28:414-421 9.Evans AJ, Richardson DB, Tien R, et al. Poststenotic signal loss in MR angiography: effects of echo time, flow compensation, and fractional echo. AJNR Am J Neuroradiol 1993;14:721-729 10.Neri E, Cosottini M, Caramella D. MR angiography of the body: technique and applications. Heidelberg: Springer, 2010:36-39 11.Caplan LR, Wityk RJ, Glass TA, et al. New England Medical - 80-

Diagnosis of Vertebral Artery Ostial Stenosis on Contrast-Enhanced MR Angiography Center Posterior Circulation registry. Ann Neurol 2004;56: 389-398 12.Hankey GJ, Warlow CP, Sellar RJ. Cerebral angiographic risk in mild cerebrovascular disease. Stroke 1990;21:209-222 대한자기공명의과학회지 15:77-81(2011) 조영증강 MR 혈관조영영상에서척추동맥기시부협착의진단 : Thin-Slab MIP technique 의유용성 1 강동경희대학교병원영상의학과 2 울산대학교서울아산병원영상의학과 3 건국대학교병원영상의학과 4 분당서울대학교병원영상의학과 5 인제대학교부산백병원영상의학과 김선미 1 이덕희 2 최진우 3 최병세 4 인현신 5 조영증강 MR 혈관조영영상에서척추동맥기시부의협착이과장되어보이며종종가성협착을보인다는것은잘알려져있다. 그러나뇌의후방순환의허혈, 경색의임상적중요성을고려하면, 척추동맥기시부협착의정확한진단은매우중요하다. 따라서저자들은 thin-slab maximum-intensity projection(mip) 영상을이용하여통상적인 full thickness MIP 영상에서보이는척추동맥기시부의진성협착과가성협착을구분하고자한다. 통신저자 : 이덕희, (138-736) 서울시송파구아산병원길 86, 울산대학교의과대학서울아산병원영상의학과 Tel. 82-2-3010-5944 Fax. 82-2-476-0090 E-mail: dhlee@amc.seoul.kr - 81-