PMP. Original Article. Introduction. Hee Jung Kim, Sung Yong Park, Young Hee Park, Ah Ram Chang

Similar documents
An audit of radiation dose of 4D CT in a radiotherapy department

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction

The Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction

Pediatric chest HRCT using the idose 4 Hybrid Iterative Reconstruction Algorithm: Which idose level to choose?

A novel platform simulating irregular motion to enhance assessment of respiration-correlated radiation therapy procedures

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

Effects of iodinated contrast media on radiation therapy dosimetry for pathologies within the thorax

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times

Potential systematic uncertainties in IGRT when FBCT reference images are used for pancreatic tumors

The Physics of Oesophageal Cancer Radiotherapy

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

From phase-based to displacement-based gating: a software tool to facilitate respiration-gated radiation treatment

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

RTTs role in lung SABR

Motion gating and tracking techniques: overview and recent developments

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Relation of external surface to internal tumor motion studied with cine CT

PII: S (02)00136-X

Image Guided Stereotactic Radiotherapy of the Lung

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

8/2/2012. Transitioning from 3D IMRT to 4D IMRT and the Role of Image Guidance. Part II: Thoracic. Peter Balter, Ph.D.

Ashley Pyfferoen, MS, CMD. Gundersen Health Systems La Crosse, WI

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 6, 2016

biij Initial experience in treating lung cancer with helical tomotherapy

For a legacy that lives large: Think Big. Philips CT Big Bore. Computed tomography

Impact of Contouring Variability on Dose- Volume Metrics used in Treatment Plan Optimization of Prostate IMRT

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

Image Registration for Radiation Therapy Applications: Part 2: In-room Volumetric Imaging

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

PMP. Gamma Evaluation with Portal Dosimetry for Volumetric Modulated Arc Therapy and Intensity-Modulated Radiation Therapy.

Protocol of Radiotherapy for Small Cell Lung Cancer

Clinical Implications of High Definition Multileaf Collimator (HDMLC) Dosimetric Leaf Gap (DLG) Variations

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 6, 2015

Impact of temporal probability in 4D dose calculation for lung tumors

Does the IMRT technique allow improvement of treatment plans (e.g. lung sparing) for lung cancer patients with small lung volume: a planning study

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

Credentialing for the Use of IGRT in Clinical Trials

SBRT of Lung & Liver lesions using Novalis IGRT System. Patrick Silgen, M.S., DABR Park Nicollet Methodist Hospital

Feasibility of improving cone-beam CT number consistency using a scatter correction algorithm.

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

An Accuracy Analysis of Tumor Tracking Algorithm According to Types of Respiration

PMP. Quantitative Evaluation of Patient Positioning Error Using CBCT 3D Gamma Density Analysis in Radiotherapy. Original Article.

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Application of asi-kvcbct for Volume Assessment and Dose Estimation: An Offline Adaptive Study for Prostate Radiotherapy

Ask EuroSafe Imaging. Tips & Tricks. Paediatric Imaging Working Group. Shielding in pediatric CT

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

Min Hur, Eun-Hee Kim, In-Kyung Song, Ji-Hyun Lee, Hee-Soo Kim, and Jin Tae Kim INTRODUCTION. Clinical Research

Comparison of CT images with average intensity projection, free breathing, and mid-ventilation for dose calculation in lung cancer

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

On the use of 4DCT derived composite CT images in treatment planning of SBRT for lung tumors

To Shield or Not to Shield? Lincoln L. Berland, M.D.

Which Planning CT Should be Used for Lung SBRT? Ping Xia, Ph.D. Head of Medical Physics in Radiation Oncology Cleveland Clinic

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

Comparison of ITV Delineation using Intensity Projections Methods for Eclipse and iplan Treatment Planning System : A Phantom Study

Methods of Counting Ribs on Chest CT: The Modified Sternomanubrial Approach 1

Tolerance levels of CT number to electron density table for photon beam in radiotherapy treatment planning system

Lung SBRT in a patient with poor pulmonary function

Role of Belly Board Device in the Age of Intensity Modulated Radiotherapy for Pelvic Irradiation

VMAT plans for treatment prostate cancer: Dosimetric verifications and comparison with 3D-CRT and IMRT

Corporate Medical Policy

Defining Target Volumes and Organs at Risk: a common language

Quantification of interplay and gradient effects for lung stereotactic ablative radiotherapy (SABR) treatments

Assessment of the Margin Simulations of Random and Systematic Errors in Radiotherapy

Comparison of IMRT and VMAT Plan for Advanced Stage Non-Small Cell Lung Cancer Treatment

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Organ Dose Reconstruction for Wilms Tumor Patients Treated with Radiation Therapy

Aytul OZGEN 1, *, Mutlu HAYRAN 2 and Fatih KAHRAMAN 3 INTRODUCTION

Ritu Raj Upreti, S. Dayananda, R. L. Bhalawat*, Girish N. Bedre*, D. D. Deshpande

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Ranking radiotherapy treatment plans: physical or biological objectives?

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

An anthropomorphic head phantom with a BANG polymer gel insert for dosimetric evaluation of IMRT treatment delivery

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

Implementation of advanced RT Techniques

I. Equipments for external beam radiotherapy

Effects of Interfractional Anatomical Changes on Water-Equivalent Pathlength in Charged-Particle Radiotherapy of Lung Cancer

Future upcoming technologies and what audit needs to address

Real-time tumor tracking during VMAT radiotherapy treatments based on 2D/3D registration using CBCT projections

Address for Correspondence: Department of Medical Physics, Khwaja Yunus Ali University, Enayetpur, Sirajgonj ,

Application of Implanted Markers in Proton Therapy. Course Outline. McLaren Proton Therapy Center Karmanos Cancer Institute McLaren - Flint

The impact of CT scan energy on range calculation in proton therapy planning

Advances in external beam radiotherapy

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

Sanja Ognjenovic A PROJECT. submitted to. Oregon State University. University Honors College

Volumetric Modulated Arc Therapy in a Large Body Habitus Patient with Left Breast Cancer: A Dosimetric Study

Flattening Filter Free beam

Measurement of Respiratory and Cardiac Motion Using a Multi Antenna Continuous Wave Radar Operating in the Near Field

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

CT NUMBER ACCURACY ANALYSIS FOR RADIOTHERAPY TREATMENT PLANNING IMAGING

Corporate Medical Policy

Corporate Medical Policy

Radiobiological Impact of Planning Techniques for Prostate Cancer in Terms of Tumor Control Probability and Normal Tissue Complication Probability

Research Article An IMRT/VMAT Technique for Nonsmall Cell Lung Cancer

Transcription:

Original Article PMP Progress in Medical Physics 28(1), March 217 https://doi.org/1.14316/pmp.217.28.1.27 pissn 258-4445, eissn 258-4453 Dosimetric Effects of Low Dose 4D CT Using a Commercial Iterative Reconstruction on Dose Calculation in Radiation Treatment Planning: A Phantom Study Hee Jung Kim, Sung Yong Park, Young Hee Park, Ah Ram Chang Department of Radiation Oncology, Soonchunhyang University Hospital, Seoul, Korea Received 24 March 217 Revised 28 March 217 Accepted 28 March 217 Corresponding author Ah Ram Chang (changaram@schmc.ac.kr) Tel: 82-2-79-9412 Fax: 82-2-79-992 We investigated the effect of a commercial iterative reconstruction technique (idose, Philips) on the image quality and the dose calculation for the treatment plan. Using the electron density phantom, the 3D CT images with five different protocols (5, 1, 2, 35 and 4 mas) were obtained. Additionally, the acquired data was reconstructed using the idose with level 5. A lung phantom was used to acquire the 4D CT with the default protocol as a reference and the low dose (one third of the default protocol) 4D CT using the idose for the spine and lung plans. When applying the idose at the same mas, the mean value was changed up to 85. Although the 1 SD was increased with reducing the CT dose, it was decreased up to 4 due to the use of idose. When using the low dose 4D CT with idose, the dose change relative to the reference was less than.5% for the target and OARs in the spine plan. It was also less than 1.1% in the lung plan. Therefore, our results suggests that this dose reduction technique is applicable to the 4D CT image acquisition for the radiation treatment planning. Keywords: Low dose 4D CT, Iterative reconstruction, Treatment planning, CT dose reduction Introduction In recent years, many studies considering the respiratory motion during radiation treatment has been published. 1-3) Since the normal breathing can cause the motion artifact when scanning the simulation CT and patients are hard to maintain a stable breath-hold, the most effective method is to generate the CT volume images for the entire respiratory cycle of free-breathing. The most common method is referred to as 4-dimensional CT (4D CT) that is correlated to the respiratory signal acquiring by the external surrogate such as Varian Real-time Position Management TM (RPM) system (Varian Medical Systems Inc, Palo Alto, CA, USA) or Philips Bellows belt system (Philips Medical Systems, Cleveland, OH, USA). The 4D CT is based on a very slow scanning and retrospectively the acquired data is binned for each phase. Due to this acquisition process of 4D CT, the use of higher CT imaging dose or CT dose is necessary than the conventional CT. 4-7) To adhere to ALARA (as low as reasonably achievable) principle in CT imaging, several novel reconstruction algorithms have been introduced in order to reduce the dose from CT scanning and to improve the image quality. 8-1) As one of them, Philips provides a 4th gene ration iterative reconstruction algorithm, idose (Philips Medical Systems, Cleveland, OH, USA). 11-13) Although the image contrast increment by using the retrospective reconstruction algorithm is beneficial for a diagnostic CT, the verification Copyright 217 Korean Society of Medical Physics CC This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/4.) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

28 Hee Jung Kim, et al:low Dose 4D CT for Radiation Treatment Planning of the changes is required to use for the dose calculation in treatment planning using the correlation table of to material density. The 4D CT has been commonly used for the radiation treatment planning. Thus, the purpose of this study is to quantify the image quality change due to the low dose 4D CT scanning with the commercial iterative reconstruction algorithm using a phantom. The effect on the dose distribution was also evaluated. Materials and Methods The CIRS electron density phantom (Computerized Imaging Reference Systems, Inc., Norfolk, VA, USA) with various density materials (e.g., lung.2 g/cc, lung.5 g/ cc, adipose.96 g/cc, breast.99 g/cc, muscle 1.6 g/cc, liver 1.7 g/cc, bone 1.16 g/cc, and bone core 1.53 g/cc) and the CIRS Xsight lung tracking phantom were used. All CT images for this study was acquired by Philips Brilliance Big Bore CT scanner (Philips Medical Systems, Cleveland, OH, USA). The scanner default protocol provided by a manufacturer is the use of 12 kvp and 35 mas. To compare the values depending on the CT imaging dose, five different protocols (5 mas, 1 mas, 2 mas, 35 mas and 4 mas) was applied in order to acquire the CT images of the electron density phantom. After that, the idose with level 5 was applied to the acquired data. To perform the treatment planning for lung and spine target, the CT images of the lung phantom were acquired using the default 4D CT scan protocol (6 mas) without applying idose and the low dose protocol (2 mas) with applying idose with level 5. The idose algorithm was applied retrospectively after CT scanning. For the spine and lung planning, the Pinnacle v9.6 treatment planning system (Philips Healthcare, Fitchburg, WI, USA) and the 6 MV photon beam were used. The 2-dimensional (2D) parallel-opposite anterior-posterior (AP-PA) plan and the volumetric modulated arc therapy (VMAT) plan were performed for the spine target. The 3-dimensional conformal radiotherapy (3D-CRT) plan and VMAT plan were also performed for the lung target. The prescription dose was 3 Gy in 1 fractions for the spine plans and 6 Gy in 3 fractions for the lung plans. The maximum, minimum, mean and 1 standard deviation (1 SD) of were evaluated and the changes on the CT images after applying idose were calculated. To delineate the region of interests inside the various density materials and to calculate that s, the MIM software (MIM Software Inc., Cleveland, OH, USA) was used. Results Overall, as the tube current-time product (mas) increased, the maximum was increased and the minimum was decreased. As shown in Fig. 1, the mean was changed due to the CT dose reduction and the use of idose. The amount of the change had a range from -21 to 87. When using the same current (mas), the mean change had a range from -2 to 85. The had no change ( ) in the muscle 1.6 g/cc, but it had a maximum change (85 ) in the bone core 1.53 g/cc. In the lowest density material (lung.2 g/cc), it showed 19 change on average. Fig. 2 shows that as the CT dose decreases, the 1 SD increased by up to 2 but it significantly decreased by 1 8 6 4 2 2 4 12 kv 5 mas 12 kv 5 mas idose 12 kv 1 mas Mean change () Adipose.96 g/cc Breast.99 g/cc 12 kv 1 mas idose 12 kv 2 mas 12 kv 2 mas idose Liver 1.7 g/cc Lung.2 g/cc Lung.5 g/cc Muscle 1.6 g/cc Fig. 1. Mean change in depending on the CT scan parameter for different density materials relative to the default scan parameter. 12 kv 4 mas 12 kv 4 mas idose Default (12 kv 35 mas)

Progress in Medical Physics Vol. 28, No. 1, March 217 29 up to 4 due to the use of idose (p-value <.1). Two 4D CT images of the lung phantom were acquired using the default scan parameter (6 mas) without idose and the low dose scan parameter (2 mas) with idose 25 2 15 1 5 5 1 12 kv 5 mas 12 kv 5 mas idose 1 Standard deviation change () Adipose.96 g/cc Breast.99 g/cc 12 kv 1 mas 12 kv 1 mas idose 12 kv 2 mas 12 kv 2 mas idose Liver 1.7 g/cc Lung.2 g/cc Lung.5 g/cc Muscle 1.6 g/cc Fig. 2. 1 Standard deviation change in depending on the CT scan parameter for different density materials relative to the default scan parameter. 12 kv 4 mas 12 kv 4 mas idose Default (12 kv 35 mas) (Fig. 3). The dose-volume histograms (DVHs) are shown in Fig. 4, 5, 6 and 7. Table 1 shows the dose-volumetric parameters from DVHs for PTV and OARs. For the spine 2D and VMAT plan, the maximum dose differences relative to the prescription dose were less than.5%. For the lung 3D conformal and VMAT plan, they were less than 1.1%. Discussion The CT radiation dose depends on the tube current (ma) and slice scan time and it is proportioned to the tube current-time product (mas). In the result of this study, the 1 SD referred to as the image noise was increased with decreasing the CT dose. However, the use of a commercial iterative reconstruction algorithm, idose, changed the values. From decreasing the 1 SD, the image noise was improved. This result is similar as the literatures. 11-14) Although the was increased in the high density material like bone, the dose change in the plans for the spine target was less than.5%. For the lung plans considering the low density around the target (known as a heterogeneity), the change due to the idose was less than 1.1%. The above results demonstrate that by using the idose the clinically acceptable quality 4D CT images could be obtained even if the CT dose is reduced to one third. Future studies using the patient 4D CT images would be helpful to investigate the optimal tube current-time product that might be changed depending on the CT scanning area of the body. Fig. 3. 4D CT images of the lung phantom acquired using the default scan parameter (6 mas) without idose (left) and the low dose scan parameter (2 mas) with idose (right).

3 Hee Jung Kim, et al:low Dose 4D CT for Radiation Treatment Planning 1 Spine (2D) 1 Spine (VMAT) 8 6 4 (idose) (idose) (idose) 8 6 4 (idose) (idose) (idose) 2 2 5 1 15 2 25 3 35 5 1 15 2 25 3 35 Fig. 4. DVH comparison between the dose calculations on the CT images reconstructed with and without using idose for the Spine 2D parallel-opposite (AP-PA) and VMAT plan. 1 Lung (3D) 1 Lung (VMAT) 8 6 4 (idose) (idose) (idose) 8 6 4 (idose) (idose) (idose) 2 2 5 1 15 2 25 3 35 4 45 5 55 6 65 7 5 1 15 2 25 3 35 4 45 5 55 6 65 7 Fig. 5. DVH comparison between the dose calculations on the CT images reconstructed with and without using idose for the Lung 3D conformal and VMAT plan. Although the idose has a level from 1 to 7, the level 5 of the idose was used in this study. As the idose level increases, the strength of noise decreases independent of the CT dose. However, the noise is increased associated with a dose reduction. The net change in noise is determined from a combination of the dose reduction and the idose level. For that reason, in this study, the one third dose reduction and idose level of 5 was selected by using the relevant multiplication factor table for the estimation of the net change in noise. Since the image quality related to the noise strength depends on the idose level, a detailed investigation for the different idose level would be necessary if the dose is reduced differently comparing to this study (one third of the default protocol). In this study, a single CT-to-density table was used for dose calculation on both images with and without idose. For example, like pediatric patients, some cases should use the low energy X-ray. In fact, since the attenuation coefficient is dependent on the X-ray energy and the material density, the is significantly changed as shown in Fig. 6. The effect of the use of idose could be different depending on the X-ray energy. In this study, as a simple test, the 9 kvp CT was compared to the default protocol 12 kvp CT. Fig. 6 shows that the mean and 1 SD change in due to the use of idose were increased with decreasing the energy from 12 kvp to 9 kvp. Compared to the default protocol, the was changed up to 347 depending on the kvp and mas. It was also changed up to 19 due to

Progress in Medical Physics Vol. 28, No. 1, March 217 31 Mean () 1 Standard deviation change () 1,5 Adipose.96 g/cc Breast.99 g/cc Liver 1.7 g/cc Lung.2 g/cc Lung.5 g/cc Muscle 1.6 g/cc 6 Adipose.96 g/cc Breast.99 g/cc Liver 1.7 g/cc Lung.2 g/cc Lung.5 g/cc Muscle 1.6 g/cc 1, 5 4 5 3 2 1 5 1, 1 9 kv 5 mas 9 kv 5 mas idose 9 kv 1 mas 9 kv 1 mas idose 9 kv 2 mas 9 kv 2 mas idose 9 kv 4 mas 9 kv 4 mas idose 12 kv 5 mas 12 kv 5 mas idose 12 kv 1 mas 12 kv 1 mas idose 12 kv 2 mas 12 kv 2 mas idose 12 kv 4 mas 12 kv 4 mas idose Default (12 kv 35 mas) 9 kv 5 mas 9 kv 5 mas idose 9 kv 1 mas 9 kv 1 mas idose 9 kv 2 mas 9 kv 2 mas idose 9 kv 4 mas 9 kv 4 mas idose 12 kv 5 mas 12 kv 5 mas idose 12 kv 1 mas 12 kv 1 mas idose 12 kv 2 mas 12 kv 2 mas idose 12 kv 4 mas 12 kv 4 mas idose Default (12 kv 35 mas) Fig. 6. Mean and 1 standard deviation changes in when using the x-ray energy of 9 kvp. Table 1. Dose-volumetric parameters of target (PTV) and normal tissues (left and right lung, spinal cord) for spine and lung plan. Spine Lung 2D (AP-PA) VMAT 3D CRT VMAT Default idose Default idose Default idose Default idose PTV D95% (Gy) 3.1 3. 29.9 29.8 6.3 6. 6.2 59.6 D5% (Gy) 31. 3.9 32.1 32. 64.4 64.2 65.1 64.5 Minimum (Gy) 29.9 29.8 24.2 24.2 58.2 57.6 58.3 57.7 Maximum (Gy) 31.3 31.2 32.9 32.8 64.7 64.5 65.7 65.1 Mean (Gy) 3.5 3.4 31.3 31.2 62.6 62.3 63.2 62.6 V2Gy (%).... 1.6 1.6 9.3 9.2 Mean (Gy).3.3.9.9 6.5 6.5 6. 6. V2Gy (%)........ Mean (Gy).3.3.9.9.9.9 1.3 1.3 V13.5Gy (%) 27.8 27.8 8.8 8.8.2.2.. Maximum (Gy) 31.6 31.5 28.6 28.5 13.7 13.7 9.5 9.5 the use of idose. Thus, when a single CT-to-density table is applied to the dose calculation for the different energy CT scan, the calculated dose can be inaccurate more than the result of this study. After applying the CT-to-density table depending on the X-ray energy, the optimal tube currenttime product when using the idose should be determined.

32 Hee Jung Kim, et al:low Dose 4D CT for Radiation Treatment Planning Conclusion In this study, the change and the dosimetric change on the 4D CT due to the use of the commercial iterative reconstruction algorithm (idose) were analyzed. Although, in general, the 4D CT needs the radiation exposure much more than 3D CT, the idose could reduce the imaging dose less than the conventional 3D CT dose with the default protocol, preserving the image quality. The effect of change due to the use of the idose for the low dose 4D CT on the dose calculation was clinically acceptable. Conflicts of Interest The authors have nothing to disclose. Availability of Data and Materials All relevant data are within the paper and its supporting information files. References 1. Balter JM, Ten Haken RK, Lawrence TS, Lam KL, and Robertson JM. Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. Int J Radiat Oncol Biol Phys. 1996;36:167-174. 2. Keall PJ, Starkschall G, Shukla H, Forster KM, Ortiz V, Stevens CW, et al. Acquiring 4D thoracic CT scans using a multislice helical method. Phys Med Biol. 24;49:253-267. 3. Ohara K, Okumura T, Akisada M, Inada T, Mori T, Yokota H, et al. Irradiation synchronized with respiration gate. Int J Radiat Oncol Biol Phys. 1989;17:853-857. 4. Hubbard P, Callahan J, Cramb J, Budd R, and Kron T. Audit of radiation dose delivered in time-resolved fourdimensional computed tomography in a radiotherapy department. J Med Imaging Radiat Oncol. 215;59:346-352. 5. Low DA, Nystrom M, Kalinin E, Parikh P, Dempsey JF, Bradley JD, et al. A method for the reconstruction of fourdimensional synchronized CT scans acquired during free breathing. Med Phys. 23;3:1254-1263. 6. Matsuzaki Y, Fujii K, Kumagai M, Tsuruoka I, and Mori S. Effective and organ doses using helical 4DCT for thoracic and abdominal therapies. J Radiat Res. 213;54:962-97. 7. Mori S, Ko S, Ishii T, and Nishizawa K. Effective doses in four-dimensional computed tomography for lung radiotherapy planning. Med Dosim. 29;34:87-9. 8. Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, and Pavlicek W. Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol. 29;193:764-771. 9. Kim Y, Kim YK, Lee BE, Lee SJ, Ryu YJ, Lee JH, et al. Ultralow-dose CT of the thorax using iterative reconstruction: evaluation of image quality and radiation dose reduction. American Journal of Roentgenology. 215;24:1197-122. 1. Raman SP, Johnson PT, Deshmukh S, Mahesh M, Grant KL, and Fishman EK. CT dose reduction applications: available tools on the latest generation of CT scanners. Journal of the American College of Radiology. 213;1:37-41. 11. Arapakis I, Efstathopoulos E, Tsitsia V, Kordolaimi S, Economopoulos N, Argentos S, et al. Using idose4 iterative reconstruction algorithm in adults' chest abdomen pelvis CT examinations: effect on image quality in relation to patient radiation exposure. The British journal of radiology. 214;87:213613. 12. Mehta D, Thompson R, Morton T, Dhanantwari A, and Shefer E. Iterative model reconstruction: simultaneously lowered computed tomography radiation dose and improved image quality. Med Phys Int J. 213;2:147-155. 13. Olsson M-L, and Norrgren K. An investigation of the iterative reconstruction method idose4 on a Philips CT Brilliance 64 using a Catphan 6 phantom. SPIE Medical Imaging. 212. 831348. 14. Li H, Lee D, Low D, Gay H, Michalski J, and Mutic S. SU- E-J-167: Iterative Reconstruction Techniques for Radiation Therapy CT Simulations: A Phantom Study. Medical Physics. 213;4:189-189.