A New Classification of Zygomatic Fracture Featuring Zygomaticofrontal Suture: Injury Mechanism and a Guide to Treatment

Similar documents
Use of Intraoperative Computed Tomography for Revisional Procedures in Patients with Complex Maxillofacial Trauma

CLINICAL STUDY. Surgical Approaches and Fixation Patterns in Zygomatic Complex Fractures

ORIGINAL ARTICLE. Facial Fracture Classification According to Skeletal Support Mechanisms

ORIGINAL ARTICLE. A Novel Technique for Malar Eminence Evaluation Using 3-Dimensional Computed Tomography

Maxillary and Periorbital Fractures January 2004

Clinical Study Open Reduction of Subcondylar Fractures Using a New Retractor

Subciliary versus Subtarsal Approaches to Orbitozygomatic Fractures

ISOLATED ZYGOMATIC BONE FRACTURE; MANAGEMENT BY THREE POINT FIXATION

Prophylactic Midface Lift in Midfacial Trauma

Craniomaxillofacial Research

ZYGOMATIC (MALAR) FRACTURES

Downloaded from Medico Research Chronicles Assault injury to the face with an axe- A rare case report.

Maxillofacial Injuries Practical Tips

ORIGINAL ARTICLE. Kris S. Moe, MD; Sumana Jothi, MD; Ryan Stern, MD; Holger G. Gassner, MD

JPRAS Open 6 (2015) 5e10. Contents lists available at ScienceDirect. JPRAS Open. journal homepage:

TRADITIONAL methods of

Temporal miniplates in the frontozygomatic area an anatomical study

Quantitative Determination of

An increasing body of evidence during the last decade. Long-term sequelae after surgery for orbital floor fractures

BONE GRAFTING IN TREATMENT OF CLEFT LIP AND PALATE 337

MDJ Zygomatic complex fractures: a 5-year retrospective study Vol.:8 No.:3 2011

HEAD & NECK IMAGING. Iranian Journal of Radiology September; 10(3): Published Online 2013 August 30.

MANAGEMENT OF ZYGOMATICO-ORBITAL FRACTURES USING RIGID INTERNAL FIXATION WITH COSMETIC SURGICAL CONSIDERATIONS - CASE REPORT

RapidSorb Resorbable Tacks. Resorbable Fixation System.

Conventional radiograph verses CT for evaluation of sagittal fracture of mandibular condyle

(Jurnal Plastik Rekonstruksi 2017; 1:82-87)

The treatment of malocclusion after open reduction of maxillofacial fracture: a report of three cases

Imaging Orbit/Periorbital Injury

Posterolateral elbow dislocation with entrapment of the medial epicondyle in children: a case report Juan Rodríguez Martín* and Juan Pretell Mazzini

CT of Maxillofacial Injuries

Three Dimensional Titanium Mini Plates in Management of Mandibular Fractures

POST OPERATIVE OUTCOMES IN OPEN REDUCTION AND INTERNAL FIXATION OF ZYGOMATIC BONE FRACTURES: TWO POINT VERSUS THREE POINT FIXATION

Case report. Open Access. Abstract

The diagnostic value of Computed Tomography in evaluation of maxillofacial Trauma

AN ELEVEN YEAR FOLLOW-UP CASE OF FACIAL HEMIATROPHY TREATED BY COMBINED APPROACHES OF CRANIOFACIAL AND

Screw hole-positioning guide and plate-positioning guide: A novel method to assist mandibular reconstruction

AcUMEDr. LoCKING CLAVICLE PLATE SYSTEM

EVALUATION OF MODIFIED EXTRAORAL TECHNIQUE IN ZYGOMATIC ARCH EXAMINATION

Technique Guide. Titanium Wire with Barb and Needle. Surgical Technique Guide for Canthal Tendon Prodecures.

Case Report Reverse Segond Fracture Associated with Anteromedial Tibial Rim and Tibial Attachment of Anterior Cruciate Ligament Avulsion Fractures

Titanium Wire with Barb and Needle. Surgical Technique Guide for Canthal Tendon Procedures.

Reduction of Closed Frontal Sinus Fractures through Suprabrow Approach

Fibular Bone Graft for Nasal Septal Reconstruction: A Case Report

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

ORIGINAL ARTICLE Correlation between projection of the ear, the inferior crus, and the antihelical body: analysis based on computed tomography

Fracture frontal bone and its management

Diagnosis of Midface Fractures with CT: What the Surgeon Needs to Know 1

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

Surgical treatment of mandibular condyle fracture with bicortical screws: case report

The Birmingham Hook Plate Treatment Of Irreduceable Displaced Mallet Avulsion Fractures: A Technical Note

MEDPOR. Oculoplastic surgery

Two Hundred Ninety-Four Consecutive Facial Fractures in an Urban Trauma Center: Lessons Learned

I. Introduction CASE REPORT

Assessment of Relapse Following Intraoral Vertical Ramus Osteotomy Mandibular Setback and Short-term Immobilization

The Retrospective Study of Closed Reduction of Nasal Bone Fracture

Carpal rows injuries!

Locking Radial Head Plates

DOWNLOAD OR READ : RIGID FIXATION FOR MAXILLOFACIAL SURGERY PDF EBOOK EPUB MOBI

Naso-Orbital Complex Reconstruction with Titanium Mesh and Canthopexy

ROTATIONAL PILON FRACTURES

Case Report Intra-Articular Entrapment of the Medial Epicondyle following a Traumatic Fracture Dislocation of the Elbow in an Adult

The eyebrow is so aesthetically important that. Reconstructive

Original Research THE USE OF REFORMATTED CONE BEAM CT IMAGES IN ASSESSING MID-FACE TRAUMA, WITH A FOCUS ON THE ORBITAL FLOOR FRACTURES

FOLLOWING INTRODUCTION OF

Use of internal callus distraction in the treatment of congenital brachymetatarsia

Zimmer Small Fragment Universal Locking System. Surgical Technique

Assessment of endoscopic role in management of facial fractures

Competence of the Deltoid Ligament in Bimalleolar Ankle Fractures After Medial Malleolar Fixation *

Case Report A Case Report of Isolated Cuboid Nutcracker Fracture

ORIGINAL ARTICLE. most commonly result. involving the paranasal sinuses, the overlying facial skin, or both. Such defects may result in substantial

Maxillo-facial and Oral Surgery Department, Withington Hospital, Manchester

Case Report An Undescribed Monteggia Type 3 Equivalent Lesion: Lateral Dislocation of Radial Head with Both-Bone Forearm Fracture

Bony hump reduction is an integral part of classic

Case Report Bilateral Distal Femoral Nailing in a Rare Symmetrical Periprosthetic Knee Fracture

Pediatric Craniofacial Injuries: Concept of Treatment

Comparative Evaluation of Single Point Fixation at Zygomatic Buttress and Fronto Zygomatic Rim in Zygomatic Complex Fractures -A Prospective Study

Multidetector computed tomographic evaluation of maxillofacial trauma

SOFT TISSUE SUPPORT IS AN

Clinical Study Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures

Marcin Czerwinski, MD, PhD, FRCS(C), FACS Reference List Abstract

Imaging of Cervical Spine Trauma Tudor H Hughes, M.D.

Surgical Anatomy Relevant to the Transpalpebral Subperiosteal Elevation of the Midface

Use of Modified Retro-mandibular subparotid approach for treatment of Condylar fracture: a Technical note

Chapter 23: Maxillofacial Trauma. Robert B. Stanley, Jr.

Case Report Arthroscopic Bony Bankart Repair Using Double-Threaded Headless Screw: A Case Report

Provision of Rotational Stability: Prevention of Collapse: Closed Fracture Reduction: Minimally Invasive Surgery with no Exposure of the Fracture:

SynPOR HD Facial Shape System. For the augmentation or reconstruction of the craniomaxillofacial skeleton.

Case Report Medial Radial Head Dislocation Associated with a Proximal Olecranon Fracture: A Bado Type V?

Titanium Wire With Barb and Needle

Department of Surgery, Prapokkla Hospital, Chantaburi 22000, Thailand. ABSTRACT

Computer modeling and intraoperative navigation in maxillofacial surgery

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

THE USE OF TEMPORARY ANCHORAGE DEVICES FOR MOLAR INTRUSION & TREATMENT OF ANTERIOR OPEN BITE By Eduardo Nicolaievsky D.D.S.

MEDIAL EPICONDYLE FRACTURES

Jaw locking after maxillofacial trauma

Institute of Reconstructive Surgery, Sofia, Bulgaria

A novel method of treating isolated unicondylar fracture of the head of the proximal phalanx: A case report

Plastic Surgeon, Middlesbrough General Hospital, Stockton Children's Hospital, Newcastle Regional Hospital Board

Isolated Comminuted Fracture of the Trapezium: A Case Report and Review of the Literature

Transcription:

IBIMA Publishing Plastic Surgery: An International Journal http://www.ibimapublishing.com/journals/psij/psij.html Vol. 2013 (2013), Article ID 383486, 6 pages DOI: 10.5171/2013.383486 Research Article A New Classification of Zygomatic Fracture Featuring Zygomaticofrontal Suture: Injury Mechanism and a Guide to Treatment Hisao Ogata, Yoshiaki Sakamoto and Kazuo Kishi Department of Plastic and Reconstructive Surgery, Keio University School of Medicine, Shinjuku-ward, Tokyo, Japan Received 21 November 2012; Accepted 10 December 2012; Published 26 January 2013 Academic Editor: Zubing Li Abstract The researchers establish a new classification system for zygomatic fractures based on computed tomography and mechanism of injury, which could be used to inform treatment options. Patients treated for isolated zygomatic fracture at the Keio University Hospital between 2004 and 2011 were recruited for this study. The cases were classified into 4 types based on the fracture pattern of the zygomaticofrontal suture and inferior orbital rim. In total, 113 patients aged 16 to 82 years (mean age (SD) = 39.8 (17.0) years), including 74 men and 39 women, were analyzed. Overall, 54 patients had shear fractures and 59 patients had greenstick type fractures. In both shear and greenstick fractures, the ratio of medial type fractures was significantly higher than that of lateral type fractures (p < 0.001). Furthermore, the number of shear type fractures in those <20 years old was lower than that in other age groups (p < 0.05). In conclusion, this classification is an epoch-making classification based on the mechanism of facial injury, and may be used to inform treatment options to achieve optimal biomechanical stability. Keywords: Zygomatic fracture, zygomaticofrontal suture, computed tomography. Introduction Historically, the energy of impact leading to these injuries was not taken into consideration,; the diagnosis and evaluation of malar fractures was considered by radiographic films sufficiently. And traditionally, Knight and North (1961), Larsen and Thomsen (1978), Kristensen and Tveterås (1986) and Zingg et al. (1992) classified the zygomatic fractures based on examination of plain radiographic films or intraoperative findings. However, regardless of the group of the classifications, Rohrich et al. (1992) and Convington et al. (1994) mentioned that 3-point fixation with steel wire is performed in almost all cases of zygomatic fractures. Recently, plate fixation has increased in popularity for the treatment of zygomatic Copyright 2013 Hisao Ogata, Yoshiaki Sakamoto and Kazuo Kishi. This is an open access article distributed under the Creative Commons Attribution License unported 3.0, which permits unrestricted use, distribution, and reproduction in any medium, provided that original work is properly cited. Contact author: Hisao Ogata E-mail: prsogata@sc.itc.keio.ac.jp

Plastic Surgery: An International Journal 2 fractures. Rohrich and Watumull (1995) and Zachariades et al. (1998) mentioned that fixation with mini or micro plates provides better rigidity and stability than wiring of fragments. Furthermore, advances in radiological techniques have led to the increased use of high-resolution computed tomography (CT) and 3- dimentional (3D) CT, which can be used to diagnose even a tiny fracture or slight gap. Furthermore, improved safety procedures had led to a reduction in the number of accidents leading to these severe deformities. However, patients demand esthetic improvement, even when they have only a slight gap, and an increasing number of cases of zygomatic fracture are being repaired surgically. The researchers consider the previous classification system should be improved. In this study, the researchers describe a new means of classifying zygomatic fractures based on 3D-CT and the type of trauma inflicted, which could be used to inform surgical strategy. Materials and Methods Patients treated for isolated zygomatic fractures at the Keio Univeristy Hospital between 2004 and 2011 were recruited for this study. Any patient who did not undergo a preoperative CT scan with 0.625 mm was excluded from this study. Patients with only zygomatic arch fracture or multiple complex fractures were also excluded. This study was approved by the Institutional Review Board of Keio University School of Medicine, and the medical protocol and ethical guidelines followed the tenets of the Declaration of Helsinki. The zygoma is supported by the following 4 regions: the zygomaticofrontal suture (ZF), inferior orbital rim (IO), zygomaticomaxillary buttress and zygomaticotemporal suture. When the zygoma undergoes an impact, the location of the resulting fracture depends on which of these supporting regions collapse. The collapse of these regions is dependent on the direction of the impact, but in general, the most structurally impaired of these regions will collapse first. The most stabile region of the zygoma is the ZF. In fact, the ZF comprises thickened cortical bone, and is triangular in shape. Collapse of the ZF requires a strong external force. Therefore, the researchers analyzed and classified the external forces based on the deviation of the zygoma featuring ZF. The researchers focused on the classification of the ZF and IO based on preoperative 3D-CT. The ZF was divided into 2 types: shear type which indicates the presence of a gap or deviation of the ZF, whereas the greenstick type indicates the absence of a gap or deviation of the ZF. Analysis of the IO is performed according to whether the zygoma is rotated on the maxilla, or below the maxilla, and is classified as lateral type and medial type, respectively (Figure 1).

3 Plastic Surgery: An International Journal Figure 1. The Type of the Malar Fracture Based on ZF and IO. (a, b) Greenstick-Medial Type. (c, d) Greenstick-Lateral Type. (e, f) Shear-Medial Type.

Plastic Surgery: An International Journal 4 (g, h) Shear-Lateral Type. Results In total, the researchers performed 176 operations for facial fracture. After applying the exclusion criteria, this study population included 113 patients aged 16 to 82 years (mean (SD) age = 39.8 (17.0) years), including 74 men and 39 women. The total numbers of patients in each group and age range are shown in Table 1. Overall, 54 patients had shear type and 59 patients had greenstick type ZF. In the shear type and greenstick type groups, the incidence of medial type was significantly greater than that of lateral type (p < 0.001). The researchers classified patient ages as follows: <20, 30 40, and >50. The ratio of shear type was 0.36, 0.56 and 0.54, respectively (p < 0.05). Table 1. Classification of Each Groups and Generations Shear Greenstick Medial Lateral Medial Lateral Total Under Teens 1 0 4 0 5 Twenties 12 2 14 8 36 Thirties 10 2 8 3 23 Forties 6 2 5 3 16 Fifties 5 1 8 1 15 Sixties 5 1 4 1 11 Over Seventies 6 1 0 0 7 Total 45 9 43 16 113 Discussion The most widely used approach for classifying fractures is the Knight and North classification system. Knight and North (1961) classified fractures into 6 groups and 4 subdivisions based on plain radiographic films. The system allows for easy evaluation and is clinically useful, but cannot be used to evaluate bone displacement in 3-dimensions. This is particularly a problem for isolated zygomatic fractures since it is thought that the displacement of zygomatic bone might be a consequence of axial rotation around a vertical.

5 Plastic Surgery: An International Journal More recently, Zingg et al. (1992) have used CT scans to aid classification, which allow for detailed 3D evaluation. However, this increases the number of groups and subdivisions to be classified, making clinical use more complicated. Therefore, the researchers sought to establish a simple, usable classification system for different types of zygomatic fractures based on the findings of 3D-CT scans. Today, high-resolution CT can be performed easily and quickly with low exposure times. 3D-CT can be reconstructed easily from the data. However, there are few reports that have used 3D-CT to classify zygomatic fractures. Previously, Manson et al. (1990) classified zygomatic fractures into fractures caused by low-energy, medium-energy and highenergy injuries. Low-energy fractures were found to result in minimal or no displacement, and had a continuous ZF. Medium or high-energy injuries resulted in fractures of all buttresses, including the ZF. In such case, the researchers used the condition of the ZF to inform this paper s classification system and report that greenstick or shear type fractures are based on the energy of injury. Rohrich and Watumull (1995) and Rinehart et al. (1989) reported that rigid miniplate fixation provides consistently better zygomatic and global symmetry than interosseous wires, and deforming forces of this magnitude require at least 2 miniplates. Therefore, many surgeons use 3 areas of internal fixation to provide rigidity and satisfactory zygomatic contour and eminence. However, dissection of the periosteum for plate fixation impairs the blood supply to the zygoma. This in turn leads to long-term complications such as bone absorption or infection. Given these complications, Nagasao et al. (2007) mentioned that the provision of adequate stability with minimal handling is preferable. Dal Santo et al. (1992), Ellis and Kittindumkerng (1996), Manson et al. (1990), Nagasao et al. (2009) and Tarabichi (1994) mentioned that the potential risk of postoperative setbacks increases when the ZF is sheared regardless of medial or lateral rotation, and proper fixation of the miniplate is particularly important in these instances. Medial and lateral rotation is based on the direction of energy associated with the injury. However, when the ZF is not sheared, but only made greenstick, medial rotation carries a higher risk of postoperative setback than the lateral. Therefore, insertion of a plate at the ZM or IO is required. If stability is a concern, a transzygomatic Kirschner wire (K-wire) can be added. Treatment of lateral rotation simply requires rotation with or without transzygomatic Kirschner wire. Based on the findings of 3D-CT, energy of injury and treatment method, the researchers classified zygomatic fractures into 3 types. First, they classified the ZF status into either shear or greenstick types. The shear type is a high-energy injury, regardless of medial or lateral rotation at the IO, and requires at least 2-point fixation involving the ZF. For the greenstick type, further analysis is performed at the IO and this type is further divided into medial and lateral types (Figure 2). The greenstickmedial type has a risk of postoperative setback, so 1 plate at ZM or IO is required. And the greenstick-lateral type is usually performed only reduction without plating.

Plastic Surgery: An International Journal 6 Figure 2. The Study s Classification Protocol and Guideline for Treatment In this study, the researchers did not consider other postoperative setbacks other than bone displacement. In clinical practice, it is necessary to consider every possible factor, such as postoperative setback, gender, age, duration between injury and operation, extent of scar associated with soft tissue and blood supply available during the dissection of the periosteum. However, the researchers believe that in the majority of cases treated according to the present classification system, there can be achieved sufficient stability for the fractured zygoma to be maintained at the correct position following repositioning. Conclusions The researchers classification system based on 3D-CT featuring ZF is a great improvement to the current classification system based on the mechanism of facial injury. The system may be used to inform clinicians about the ideal fixation strategy conducive to biomechanical stability. This classification system is a very useful and easy tool for the classification of zygomatic fractures and may serve to improve surgical outcomes in patients. References Covington, D. S., Wainwright, D. J., Teichgraeber, J. F. & Parks, D. H. (1994). Changing Patterns in the Epidemiology and Treatment of Zygoma Fractures: 10- Year Review, J Trauma, 37 (2) 243-248. Dal Santo, F., Ellis, E. & Throckmorton, G. S. (1992). The Effects of Zygomatic Complex Fracture on Masseteric Force, J Oral Maxillofac Surg, 50 (8) 791-799. Ellis, E. & Kittidumkerng, W. (1996). Analysis of Treatment for Isolated Zygomaticomaxillary Complex Fractures, J Oral Maxillofac Surg, 54 (4) 386-400. Knight, J. S. & North, J. F. (1961). The Classification of Malar Fracture: An Analysis of Displacement as a Guide to Treatment, Br J Plast Surg, 13 325-339. Kristensen, S. & Tveterås, K. (1986). Zygomatic Fractures: Classification and Complications, Clin Otolaryngol Allied Sci, 11 (3)123-129. Larsen, O. D. & Thomsen, M. (1978). Zygomatic Fracture: A Simplified Classification for Practical Use, Scand J Plast Reconstr Surg, 12 (1) 55-58. Manson, P. N., Markowitz, B., Mirvis, S., Dunham, M. & Yaremchuk, M. (1990). Toward CT-Based Facial Fracture Treatment, Plast Reconstr Surg, 85 (2) 202-212. Nagasao, M., Nagasao, T., Imanishi, Y., Tomita, T., Tamaki, T. & Ogawa, K. (2009). Experimental Evaluation of Relapse-Risks in Operated Zygoma Fractures, Auris Nasus Larynx, 36 (2) 168-175. Nagasao, T., Tamada, I., Miyamoto, J., Ogata, H., Kaneko, T., Nagasao, M. & Nakajima, T.

7 Plastic Surgery: An International Journal (2007). Effectiveness of Additional Transmalar Kirschner Wire Fixation for a Zygoma Fracture, Plast Reconstr Surg 119 (3) 1010-1019. Rinehart, G. C., Marsh, J. L., Hemmer, K. M. & Bresina, S. (1989). Internal Fixation of Malar Fractures: An Experimental Biophysical Study, Plast Reconstr Surg, 84 (1) 21-25. Rohrich, R. J., Hollier, L. H. & Watumull, D. (1992). Optimizing the Management of Orbitozygomatic Fractures, Clin Plast Surg, 19 (1) 149-165. Rohrich, R. J. & Watumull, D. (1995). Comparison of Rigid Plate Versus Wire Fixation in the Management of Zygoma Fractures: A Long-Term Follow-Up Clinical Study, Plast Reconstr Surg, 96 (3) 570-575. Rowe, N. L. & Killey, H. C. (1968). 'Fractures of the Facial Skeleton, 2nd ed.,' E&S. Livingstone, Edinburgh and London Tarabichi, M. (1994). Transsinus Reduction and One-Point Fixation of Malar Fractures, Arch Otolarngol Head Neck Surg, 120 (6) 620-625. Zachariades, N., Mezitis, M. & Anagnostopoulos, D. (1998). Changing Trends in the Treatment of Zygomaticomaxillary Complex Fractures: A 12-Year Evaluation of Methods Used, J Oral Maxillofac Surg, 56 (10)1152-1156. Zingg, M., Laedrach, K., Chen, J., Chowdhury, K., Vuillemin, T., Sutter, F. & Raveh, J. (1992). Classification and Treatment of Zygomatic Fractures: A Review of 1,025 Cases, J Oral Maxillofac Surg, 50 (8) 778-790.