Delta Force. Bracket System. Putting you in the driver s seat for ultimate control

Similar documents
The Rondeau System. Brackets, Bands, Buccal Tubes and Archwires. Orthodontic supplies recommended by Dr. Brock Rondeau

Victory Series Active Self-Ligating Brackets. Reliable. and. Effective

Introducing the Clarity SL Self-Ligating Appliance System

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

Plus Combines Traditional Twin Bracket Treatment With Self-Ligation Convenience

MAESTRO Low-Profile Bracket System. Discover the precision, comfort, and control of the MIM-Manufactured Maestro Bracket

Aesthetic Brackets and Accessories

Victory Series Buccal Tubes Designed for Comfort and Performance. Advanced, Precise. Solutions. for Molars

Bracket Systems. A good bracket is the foundation of a good treatment plan... Go ahead, choose the best. Metal Bracket.

GREAT LAKES BRACKETS. Treat with Quality. Treat with Confidence.

TOL

Bands Buccal Tubes Lingual Attachments. When only the best will do.

Quality. Elegance. Innovation.

Thermal Nitanium. Archwires. Reduced Friction. Accelerated Results.

THE MBT VERSATILE+ APPLIANCE SYSTEM

TransForce 2. Arch Developer Appliances Clinical Cases. New Horizons In Orthodontics

Archwire Insertion and Disengagement Instruments Technique Guide

ARCHWIRE. An extensive selection of high quality wire types and arch forms WIRE PRODUCTS. Wires. TruFlex Nickel Titanium Archwire. TruFlex.

System Orthodontic Treatment Program By Dr. Richard McLaughlin, Dr. John Bennett and Dr. Hugo Trevisi

Archwires & Accessories

SE NiTi Heat Activated NiTi Ultra T Heat Activated NiTi Stainless Steel Beta Titanium. Ultra T Archwires

BRACKET CHOICES SYSTEM CHOICES. Empower 2 reconvertible molar tubes provide versatility without compromise.

Table of Contents Section 7 Table of Contents

wiirre e a a n n d d w wiirre e ffo orrms ms

Clarity. Form meets function: Discover the science behind a versatile self-ligating bracket system. Aesthetic Orthodontic Solutions

Bands and Attachments

The Ultimate in Crystal Clear Aesthetics

Table of Contents Section 6 Table of Contents

H4 Speaker s Bureau. Dr. John Pobanz

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required

Simply Great Wire! Great prices.

Ormco ORTHODONTIC PRODUCTS CATALOG A WORLD OF BEAUTIFUL SMILES

3D CONTROL HAS ARRIVED

essentialstm cutting your consumable costs brackets tubes wires springs instruments T:

Orthodontic Product Catalog

rocky mountain orthodontics functionaleducation

ORTHODONTIC PRODUCTS CATALOG

Advantages. Fantastic. systems. Together with Unitek Lateral Development Archwires, this system puts you in control to

We Give Back. Reduce Emergency Visits! ATTACHMENTS. No More Poking Archwires! Crimpable Mini Stops. Tooth Tone Crimpable Mini Stops

MemRx Orthodontic Appliances

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

6. Timing for orthodontic force

TUBES, LINGUAL ATTACHMENTS AND BANDS. tportho.com cosmeticbraces.com. POD_TPOC_04_Tubes_Linguals_Bands_2017, Rev. 1

Advantages. Fantastic. Treatment. Finishes. 3M Self-Ligating Appliances Lateral Development System. Unitek Lateral Development Archwires

SnapLink Re-Convertible Tube

The management of impacted

INTRAORAL / EXTRAORAL. tportho.com cosmeticbraces.com. POD_TPOC_06_Intraoral_Extraoral_2017, Rev. 1

THE RELIABLE AESTHETIC CHOICE

Bicuspid Cuspid Maxillary Brackets. Bicuspid Central Cuspid Lateral... 84

Clarity. Esthetic Orthodontic Solutions. 3M Clarity Ultra Self-Ligating Brackets Practice confidently. Smile beautifully.

Open Coil (Compression) Springs

Forsus Class II Correctors as an Effective and Efficient Form of Anchorage in Extraction Cases

Table of Contents Section 1 Table of Contents

Lab Forms and Communications Precise Indirect Bonding Systems.

A Collection of High Quality Orthodontic Instruments

LINGUAL STRAIGHTWIRE BRACKET SYSTEM Designed with Drs. Kyoto Takemoto and Giuseppe Scuzzo

GAME CHANGER. Beats The Market Leader With 10 Essential Enhancements. Introducing the All-New Carriere SLX Bracket System. fast gentle natural

Space Closure Biomechanics Applied Using The MBT System Technique

Great Smiles Begin With

Brackets

With judicious treatment planning, the clinical

LINGUAL STRAIGHTWIRE BRACKET SYSTEM Designed with Drs. Kyoto Takemoto and Giuseppe Scuzzo

The Tip-Edge appliance and

ORTHODONTIC. October CREATIVE GALAXY METAL MINI BRACKETS LOW PROFILE LOW NICKEL CREATIVE VENUS LASER WELDED MINI BRACKETS LOW PROFILE LOW NICKEL

American Orthodontics (800) NiTi, superelastic NiTi, thermal NiTi x.022,.017 x.025,.018 x.025,.019 x.025

Adenta USA adentausa.com (888) BREEZE SL Empower 2 Passive SL. Interactive selfligating

PRE-FINISHER APPLIANCE AND BONDABLE LINGUAL RETAINERS. tportho.com cosmeticbraces.com. POD_TPOC_09_PreFinisher_Retainers_2015, Rev.

Intra- and extraoral.

From Plan B to Plan A : Using Forsus Class II Correctors as a Regular Mode of Treatment

CLASS II CORRECTION SIMPLIFIED

Bracket Cutter Orthodontic Pliers Wire Cutter Ligature Instrument Bonding Instrument Orthodontic Articulator Measuring Device Torch Locking Tweezers

Low-Force Mechanics Nonextraction. Estimated treatment time months (Actual 15 mos 1 week). Low-force mechanics.

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282

GAC Archwire Collection

Wire is the key player in the movement of teeth, so choosing the right wire is critical for successful treatment. ODP offers a full range of wire

A smile can conquer the world. Introducing the Quick bracket range.

Treatment of Class II, Division 2 Malocclusion in Adults: Biomechanical Considerations FLAVIO URIBE, DDS, MDS RAVINDRA NANDA, BDS, MDS, PHD

Gentle-Jumper- Non-compliance Class II corrector

Honing Damon System Mechanics for the Ultimate in Efficiency and Excellence Jeff Kozlowski, DDS East Lyme, CT

Class I. Clear Fixed Appliance vs. Aligner Treatment for Arch Development. Clinician: Dr. Stuart Frost, Phoenix, AZ Patient: A.M.

Passive friction active control

The Difference is More than Cosmetic

Clarity ADVANCED Ceramic Brackets. Advanced Ceramics. Enhanced Beauty.

INDEX. Zeusan Exporting Ltd 2/14. Product page

ortho case report Sagittal First international magazine of orthodontics By Dr. Luis Carrière Special Reprint

BOCL-01: Bonding Materials Checklist

Supplies. Online. Reliability at a great value. Dentaurum. shop.dentaurum.com

Table of Contents Section 12 Table of Contents

S.H. Age: 15 Years 3 Months Diagnosis: Class I Nonextraction Severe crowding, very flat profile. Background:

Crowding and protrusion treated by unusual extractions

The 20/20 Molar Tube. Ronald M. Roncone, D.D.S., M.S.

Keeping all these knowledge in mind I will show you 3 cases treated with the Forsus appliance.

The Science Behind The System Clinical Abstracts, Volume 2

Experience with Contemporary Tip-Edge plus Technique A Case Report.

ORTHODONTIC BANDING AND CEMENTATION. Materials

Ortho Specialties. UniCoat Aesthetic Archwires MidTherm. Grabber. Enhance Ceramic. S.E.T. Super Elastic Torqued Anterior Pretorqued Archwires

(12) Patent Application Publication (10) Pub. No.: US 2005/ A1

Arch Development: Clear Fixed Appliance vs. Aligner Treatment

Special Offers ContacEZ IPR Strip System. ipremium Plus Low Profile Buccal Tubes FREE. easy ways to order! 2 FREE

Transcription:

Delta Force Bracket System Putting you in the driver s seat for ultimate control

Variable Force Orthodontics The Delta Force Bracket System incorporates an advanced design that allows you to control the friction between the archwire, bracket and ligatures. The advanced technology and variations in ligature placement provide full control over the sliding mechanics offering the ability to easily increase or decrease friction for better treatment planning and results. Delta Force Brackets have unique features to achieve variable force ligation throughout the treatment stages. Early in treatment: Light force can be attained for excellent sliding mechanics and low friction. Intermediate stage of treatment: Medium force can be utilized for anchorage and stabilization, as well as initial torquing forces. Final treatment stage: Maximum force can be attained to provide precise finishing and detailing of the occlusion. A combined single/twin bracket, the Delta Force Bracket has a unitary body featuring a gingival ball hook, mesialdistal ligature post as well as three occlusal tie wings, allowing greater inter bracket width. This configuration provides maximum archwire deflection for quick and easy ligation to irregular teeth. Plus, the triangular design gives the low friction advantages of a narrow bracket with the rotational control of a twin bracket. Variable ligation makes it possible to use a full rectangular wire earlier in treatment for torque control. Enjoy the technical benefits of ligature placement and reduced archwire changes, while providing your patients more satisfaction. Plus, the low profile design offers increased patient comfort and better oral hygiene. figure a Minimum Force Start your treatment with passive ligation for minimum force. Rapid leveling and aligning can be attained as the ligation is configured to prevent the ligature from directly contacting the archwire. The free sliding mechanics created result in low friction and more patient comfort during this early phase of treatment (figure a minimum force). figure d Maximum Force You may finish your treatment with maximum force by locking the archwire in for full expression of the straight arch bracket. Tie the ligature to lock the archwire in the tip, torque and rotational control (figure d maximum force). figure b Medium Force In the next stage, medium force is achieved through limited contact of the ligature and the archwire. This configuration uses a standard ligation, full tip, torque and rotational control through lightly seating a rectangular archwire (figure b medium force). figure e Maximum + Force If needed, for full expression of the straight arch bracket system, you can apply maximum + force, by placing an inverted V elastic ligation (figure e maximum + force). Optional Step Rotation Control and Force If necessary, extra rotation can be created by ligating behind one tie wing on one side. Please note, rotation will occur towards the non-ligated wing (figure c rotation ligation). figure c

Delta Force Bracket Features Smooth Radiused Ball Hook To facilitate elastic placement Extended Mesial-Distal Posts To support ligature ties Centered Scribe Line For accurate bracket placement Single Gingival Ligature Post Maximizes archwire expression Micro Etched Grip-LOK Mesh Base Provides maximum retention Beveled Slot Enables easier archwire insertion Triple Occlusal Tie Wing For maximum rotational control Center Post For low friction mechanics The Delta Force Bracket System allows you ultimate control: Incisor torque Upper incisor brackets provide additional lingual root torque, while lower incisor brackets provide labial root torque. These adjustments assist in providing a full smile at the end of treatment One-piece metal injection molded bracket eliminates the bracket and pad separation Low profile for increased patient comfort and better oral hygiene Micro etched Grip-LOK Base improves bond strength, thereby reducing bond failures Nickel-Lite Material for nickel sensitive patients Delta Force Bracket Grip-LOK Base

The Delta Force Bracket A Change for the Better figure 1 Archwire Deflection The reduced mesial-distal width of the gingival ligature post on the unitary body allows the archwire to be easily flexed into the bracket slot, especially in severe malocclusion cases (figure 1). Accurate In-Out Alignment Individual bracket thickness is designed into each Delta Force Bracket (labial-lingual) reducing the need for 1 st order (in/out) wire bends. figure 2 Torque in Base Torque is incorporated into each bracket to provide you with ultimate precision and control. The brackets are also anatomically contoured (mesial-distal/occlusal-gingival) for an accurate fit of each individual tooth. In addition, the design promotes level slot line-up (figure 2). Torque Control Torque in the mandibular bicuspid brackets and molar buccal tubes has been reduced to -12 degrees to reduce unwanted lingual dumping in the mandibular arch. figure 3 Rotational Control The occlusal tie wings of the Delta Force Brackets are designed to be as wide as the tie wings on the Elite Mini-Twin Brackets to maximize rotational control (figure 3). figure 4 Reference Points Each bracket has three reference points for fast and accurate placement. A center scribe line aligns with the long axis of the clinical crown. The archwire slot and occlusal base line up with the occlusal tooth surface (figure 4). figure 5 Power Hook Nickel Lite Cuspid Brackets with optional power hooks are available for increased efficiency in closing spaces and retracting anterior teeth (figure 5). figure 6 Aesthetics Line Delta Force Brackets are also available in ceramic providing patients with a fully translucent natural look. They are made from pure polycrystalline and crafted to resist breakage (figure 6).

Delta Force Brackets Nickel-Lite Brackets Ceramic Brackets maxillary Color- tooth Torque Angulation ITEM numbers Ceramic Item Numbers Code number.022 R.022 L color-code.022 R.022 L Centrals black U1 +22 +5 702-901 702-902 black 700-101 700-102 Laterals pink U2 +14 +10 702-905 702-906 pink 700-103 700-104 Cuspids green U3 +5 +11 702-909 702-910 green 700-105 700-106 Power green U3 +5 +11 702-909PH 702-910PH Hooks Bicuspids no color U4&5s -5 0 702-915 702-915 purple 700-107 700-107 dot MANDIBULAR.022 R.022 L.022 R.022 L Anteriors no color L1&2s -5 0 702-921 702-922 yellow 700-108 700-108 dot Cuspids blue L3-5 +5 702-925 702-926 blue 700-109 700-110 Power blue L3-5 +5 702-925PH 702-926PH Hooks Bicuspids no color L4&5s -12 0 702-929 702-929 red 700-111 700-111 dot * Upper bicuspids have no ID marking. Lower bicuspids have a recessed dot on the hook. Ancillary Products Rotation Wedge Specifically designed for use with the Delta Force Bracket System, the simple opening actually fits around the entire perimeter. The wedge portion provides the pressure to efficiently rotate the tooth Available in silver, catalog number 400-302 and clear, catalog number 400-303 (50 per pack) Maxi-Tie Ligatures Nitanium Closed Coil Springs Larger than the standard ligature gives extra space and flexibility with increased elasticity Use when ligating for maximum + force with inverted V elastic ligation for full expression of the straight arch bracket system Available in clear, catalog number 400-051 and silver, catalog number 400-052 10 ligatures per stick (10 sticks per pack) Manufactured from super-elastic nickel titanium alloy. Coil springs close spaces with consistent and predictable results. Exclusive perpendicular loop design is easy to engage and remove. Available in 200 grams and 300 grams of force, and length from 9mm to 18mm

The Delta Force Bracket System Recommended Archwire Sequence: Initial Diameter upper lower Dimpled Bio-Kinetix Thermally Activated Nitanium Archwire.014 100-852DM 100-853DM Intermediate Diameter upper lower Dimpled Bio-Kinetix Thermally Activated Nitanium Archwire.016 x.025 100-874DM 100-875DM Multi Force Nitanium Archwire.020 x.020 100-840 100-841 Finishing Diameter upper lower CNA Beta Pro Form Archwire.018 x.025 100-947 100-957 For Extra Torque (optional) Diameter upper lower CNA Beta III Pro Form Archwire.019 x.025 100-948 100-958 CNA Beta III Pro Form Archwire.021 x.025 100-949 100-959 For more information on our products, orthodontic laboratory services and educational offerings, please contact us: Customer Service: 888.851.0533 In the U.S.: 800.547.2000 Outside the U.S.: +1.760.448.8600 Canada: CERUM 800.661.9567 To fax an order: 800.888.7244 To fax an order outside the U.S.: +1.760.448.8607 To email an order: USASales@OrthoOrganizers.com 1822 Aston Avenue Carlsbad, CA 92008 USA www.orthoorganizers.com 2009 Ortho Organizers, Inc. All rights reserved. PN 999-168 Rev 02/09