OtticaFisiopatologica

Similar documents
STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation

Relationship between the GDx VCC and Stratus OCT in Primary Open Angle Glaucoma

Structural examina.on: Imaging

C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma

Parafoveal Scanning Laser Polarimetry for Early Glaucoma Detection

S Morishita, T Tanabe, S Yu, M Hangai, T Ojima, H Aikawa, N Yoshimura. Clinical science

Sensitivity and specificity of new GDx parameters Colen TP, Tang NEML, Mulder PGH and Lemij HG Submitted for publication CHAPTER 7

The only measure of RNFL Integrity: GDxPRO

Advances in OCT Murray Fingeret, OD

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

The only measure of RNFL Integrity : GDxPRO

Relationship between GDx VCC and Stratus OCT in juvenile glaucoma

Scanning Laser Polarimetry and Optical Coherence Tomography for Detection of Retinal Nerve Fiber Layer Defects

Diagnostic Accuracy of Scanning Laser Polarimetry with Enhanced versus Variable Corneal Compensation

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

THE BASIC PATHOLOGIC CHANGE IN GLAUCOMA IS

Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation

Evaluation of retinal nerve fiber layer thickness parameters in myopic population using scanning laser polarimetry (GDxVCC)

The Role of the RNFL in the Diagnosis of Glaucoma

CLINICAL SCIENCES. optic neuropathy characterized

Position of retinal blood vessels correlates with retinal nerve fibre layer thickness profiles as measured with GDx VCC and ECC

CLINICAL SCIENCES. Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Robert N. Weinreb, MD

Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.

Scanning laser polarimetry (SLP) provides real-time, objective

Detection of Progressive Retinal Nerve Fiber Layer Loss in Glaucoma Using Scanning Laser Polarimetry with Variable Corneal Compensation

Ganglion cell complex scan in the early prediction of glaucoma

Correlating Structure With Function in End-Stage Glaucoma

Il contributo dell'angio-oct: valutazione integrata della componente nervosa e vascolare della malattia glaucomatosa

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

Eye Movements, Strabismus, Amblyopia, and Neuro-Ophthalmology

MEDICAL POLICY. Proprietary Information of Excellus Health Plan, Inc. A nonprofit independent licensee of the BlueCross BlueShield Association

Diagnostic Accuracy of OCT with a Normative Database to Detect Diffuse Retinal Nerve Fiber Layer Atrophy: Diffuse Atrophy Imaging Study METHODS

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

Clinical decision making based on data from GDx: One year observations

The Relationship between Standard Automated Perimetry and GDx VCC Measurements METHODS

Study of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma

Reliability analyses of the GDx nerve-fiber analyzer

Retinal Nerve Fiber Layer Measurement Variability with Spectral Domain Optical Coherence Tomography

International Journal of Scientific & Engineering Research, Volume 4, Issue 12, December ISSN

Relationship Between Structure

MEDICAL POLICY. Proprietary Information of YourCare Healthcare

To assess the glaucoma diagnostic ability of Fourier Domain Optical Coherence Tomography

Clinical Use of OCT in Assessing Glaucoma Progression

Scanning laser polarimetry (SLP) incorporates a confocal

The thickness of the retinal nerve fiber layer (RNFL) is an

RETINAL NERVE FIBER LAYER

Assessment of retinal ganglion cell loss is critical for the

Retinal nerve fiber layer measured by Heidelberg retina tomograph and nerve fiber analyzer

Advances in the Structural Evaluation of Glaucoma with Optical Coherence Tomography

Corporate Medical Policy

Seiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods

Eye (2005), 1 9 & 2005 Nature Publishing Group All rights reserved X/05 $

OCT in the Diagnosis and Follow-up of Glaucoma

Discrimination between normal and glaucomatous eyes with visual field and scanning laser polarimetry measurements

Ability of Scanning Laser Polarimetry (GDx) to Discriminate among Early Glaucomatous, Ocular Hypertensive and Normal Eyes in the Korean Population

Key words: Glaucoma, Imaging, Ophthalmoscopy, Optic neuropathy, Topography

Peripapillary Retinal Thickness. Maps in the Evaluation of Glaucoma Patients: A Novel Concept.

Although measurements of the optic disc and retinal nerve

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

MATERIALS AND METHODS

Available online at Pelagia Research Library. Advances in Applied Science Research, 2013, 4(6):

The Measure of Confidence

doi: /

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Cirrus TM HD-OCT. Details define your decisions

Patterns of Subsequent Progression of Localized Retinal Nerve Fiber Layer Defects on Red-free Fundus Photographs in Normal-tension Glaucoma

Fourier Analysis of Scanning Laser Polarimetry Measurements with Variable Corneal Compensation in Glaucoma

Relationship between Scanning Laser Polarimetry with Enhanced Corneal Compensation and with Variable Corneal Compensation

A Comparative Analysis of Ganglion Cell Complex Parameters in Nigerian Negroes with Glaucoma and Macular Disease

EXPERIMENTAL AND THERAPEUTIC MEDICINE 6: , 2013

A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements

Linking structure and function in glaucoma

CLINICAL SCIENCES. Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography

Mark Dunbar: Disclosure

NERVE FIBER LAYER THICKNESS IN NORMALS AND GLAUCOMA PATIENTS

Cirrus TM HD-OCT. Details defi ne your decisions

Optical coherence tomography (OCT) is a noninvasive,

* Şükrü Bayraktar, MD, Zerrin Bayraktar, MD, and Ömer Faruk Yilmaz, MD

Investigation of the relationship between central corneal thickness and retinal nerve fiber layer thickness in ocular hypertension

NIH Public Access Author Manuscript Arch Ophthalmol. Author manuscript; available in PMC 2013 October 01.

Macular Thickness Assessment in Patients with Glaucoma

Evaluation of Retinal nerve fiber layer thickness, mean deviation and visual field

In some patients with glaucoma, standard (achromatic) automated

Assessment of Retinal Nerve Fiber Layer Changes by Cirrus High-definition Optical Coherence Tomography in Myopia

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

Evolving glaucoma management True diagnostic integration for the preservation of vision

Ganglion cell analysis by optical coherence tomography (OCT) Jonathan A. Micieli, MD Valérie Biousse, MD

Glaucoma Evaluation. OCT Pearls for Glaucoma. OCT: Retinal Nerve Fiber Layer. Financial Disclosures. OCT: Macula. Case Example

Ophthalmology. Proofs of ophthal and PTS# 4157 ===== Dear Author:

Reproducibility of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Optical Coherence Tomography

A comparison of HRT II and GDx imaging for glaucoma detection in a primary care eye clinic setting

LARGE DISCS WITH LARGE CUPS A DIAGNOSTIC CHALLENGE IN AFRICAN PATIENTS. Darshana Soma

Ophthalmology Department, Lozano Blesa University Hospital, c/ San Juan Bosco 15, Zaragoza, Spain 2

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

Analysis of the Origin of Atypical Scanning Laser Polarimetry Patterns by Polarization-Sensitive Optical Coherence Tomography

Glaucoma Diagnosis & Tracking with Optical Coherence Tomography

Rates of Abnormal Retinal Nerve Fiber Layer and Ganglion Cell Layer OCT Scans in Healthy Myopic Eyes: Cirrus Versus RTVue

OPTOMETRY RESEARCH PAPER

Individual A-Scan Signal Normalization Between Two Spectral Domain Optical Coherence Tomography Devices

Transcription:

Anno quindicesimo dicembre 2010 How to assess the retinal nerve fiber layer thickness Antonio Ferreras Miguel Servet University Hospital, Zaragoza. Aragón Health Sciences Institute University of Zaragoza (Spain) Relazione presentata al 2 nd Siena Glaucoma Summer School 225 Primary open-angle glaucoma is a progressive multifactorial optic neuropathy characterized by an acquired loss of ganglion cells and their axons in the retina. 1,2 Damage to the retinal nerve fiber layer (RNFL) is usually followed by changes in the optic nerve head shape and specific visual field defects. The recognition of defects in the RNFL is key for early glaucoma diagnosis. 3,4 In glaucoma patients, the RNFL can be evaluated by red-free fundus photographs, scanning laser polarimetry (SLP), and optical coherence tomography (OCT). Monochromatic fundus photographs A series of red-free digital fundus photographs of each eye should be acquired for RNFL evaluation. One photograph must be centered on the optic disc and another two on each arcuate zone. The pattern of the fiber bundles can be detected as bright striations in the retinal reflex. In normal eyes, the RNFL is usually best visible in the inferior temporal part of the fundus, followed by the superior temporal region, the nasal superior region and the nasal inferior region. 5 Different patterns can be observed in the assessment of RNFL by monochromatic fundus photographs (Fig. 1): 1) Slit-like RNFL defects are darker focal areas with reduced or lost visibility of the normal striation pattern; these are smaller than a first order branch vein, and do not extend to the disc margin. This pattern can be found in healthy eyes. 2) Wedge defects are darker focal areas with reduced or lost visibility of the normal striation pattern; these are wider than a first order branch vein, originating at the disk border and arching from the disc to the periphery. This is a typical glaucomatous pattern. 3) Diffuse loss is a diffuse and generalized rarefaction of the normal striation pattern, which seems to blur into a uniform, dull, granular, white-gray area. The retinal vessels are normally embedded in the RNFL. In eyes with diffuse RNFL loss, the retinal vessels are covered only by the inner limiting membrane, resulting in better visibility and a sharper image of the large retinal vessels. This is also a finding of glaucomatous eyes, and requires an accurate inspection to be detected. Red-free fundus photographs have been used for decades to qualitatively assess the RNFL status. The highly subjective nature of this method and the requirement for experienced evaluators, however, limit its general applicability. 6 In recent years, different instruments have been introduced to quantitatively measure peripapillary RNFL thickness. New imaging devices that allow for quantitative analysis of RNFL thickness, such as SLP and OCT, provide a breakthrough for establishing a glaucoma diagnosis, and in some cases, for early

Anno quindicesimo dicembre 2010 fig. 1 226 fig. 1 Retinal nerve fiber layer redfree fundus photographs. (a): bright striations in the retinal reflex following an arcuate course around the fovea, in a normal individual. (b): slitllike RNFL defects can be seen in normal individuals. (c): Wedge defect in a glaucoma patient. (d): diffuse loss in a patient with advanced glaucoma. glaucoma detection even before perimetric changes have been established. 7,8 Scanning laser polarimetry SLP is an imaging technology designed to provide objective assessment of the RNFL with potential use for diagnosis and follow-up of patients with glaucoma. It is based on the principle that polarized light doublepassing through the RNFL is split into two orthogonally polarized, phase shifted components. SLP measures the phase shift (retardation) of light that has passed the birefringent fibers of the RNFL. The amount of linear retardation of light at each corresponding retinal location is proportional to the RNFL thickness. 9-11 Nevertheless, there are other birrefringent structures in the anterior pole (cornea and lens), which must be compensated. To neutralize the confounding influence of anterior pole birrefringent tissues on RNFL thickness, the polarimeter has an integrated variable corneal compensator (VCC), which determines and neutralizes eye-specific corneal polarization axis and magnitude using the concept of the macula as an intraocular polarimeter. 12-14 The last version of SLP (GDx Pro, Carl Zeiss Meditec, Dublin, CA) includes the enhanced corneal compensation (ECC) software, which improves compensation in atypical patterns of peripapillary birrefringent structure. 15,16 To obtain reproducible measurements, scans must be of acceptable quality (well focused and centered with a quality report 7). The GDx provides RNFL parameters based on a calculation circle, which is automatically placed around the optic disc. The calculation circle defines the area where data are acquired for the temporal-superior-nasal-inferiortemporal (TSNIT) parameters: TSNIT average, superior average, inferior average, TSNIT standard deviation, and inter-eye symmetry. The TSNIT parameters are color-coded according to a normative database indicating deviation from normality. Moreover, the GDx printout shows a learning classifier, the nerve fiber indicator (NFI), which is not a color-coded parameter. The NFI is calculated from a neural network analysis, trained to optimally discriminate between healthy and glaucomatous eyes. It analyses the RNFL profile and provides a single number representing the integrity of the entire RNFL. A higher number is more likely to be related to abnormality, but is not definitive (range from 1 to 100). It has been suggested the 95th percentile as the best cut-off point for glaucoma diagnosis (NFI value = 30). The GDx printout reports quality

fig. 2 fig. 2 Printout of the Cirrus optical coherence tomography (OCT, Carl Zeiss Meditec). The last version software for this OCT includes optic nerve head and retinal nerve fiber layer analysis in a single test. 227 indicators, fundus images, nerve fiber layer maps, RNFL parameters, deviation maps, and RNF profiles compared with the normative database. The GDx also includes a software to evaluate progression, called Guided Progression Analysis (GPA), which compares an observed change with its expected test-retest variability. This analysis considers the two first examinations as baseline and then compares with it the follow-up tests. GPA uses the Image Progression Map to determine narrow focal defects, the TSNIT progression graph to find broader focal defects, and the Summary Parameter Chart to detect diffuse defects. Optical coherence tomography The first OCT imaging studies of the human retina were reported in 1993. 17,18 Since then, this technique has been rapidly adopted into clinical practice and is now one of the main diagnostic methods in ophthalmology. The OCT employs the principles of low-coherence interferometry. It is analogous to ultrasound B-mode imaging, but it uses light instead of sound to acquire high-resolution images. The performance of OCT has been constantly improved since its introduction and the latest generation, spectral-domain OCT, provides three-dimensional images having higher axial resolution compared to the previous OCT version, time-domain OCT (400 A-scan per second). Increased scanning speed (more than 20,000 A-scan/s) allows spectral-domain OCT to obtain a three dimensional cube of data, and advances in light source technology have enhanced axial resolution significantly. The cube of data enables a far more extensive assessment of the peripapillary area including TSNIT RNFL profiles, en face RNFL images (fundus image) and optic nerve head assessment (Figure 2). OCT is the only non-invasive method that enables physicians to obtain in vivo high-resolution crosssectional images of the retina. The fastest commercially available spectral-domain OCTs are Cirrus OCT (Carl Zeiss Meditec; 27,000 A-scan per second) and Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany; 40,000 A-scan per second). Both devices provide true RNFL thickness (in microns) at 6 or 12

Anno quindicesimo dicembre 2010 228 sectors around the optic disc and an average RNFL thickness. All these thicknesses are color-coded according to a normative database. Cirrus OCT also includes the GPA software, which uses multiple algorithms to detect progression. The GPA printout shows from 3 to 8 RNFL thickness maps chronologically from left to right. The two first examinations are considered as baseline exam. Then, the follow-up scans (3 rd through last) are compared to baseline exam and areas of statistically significant change are highlighted in yellow or red (focal change). Furthermore, the GPA evaluates RNFL thickness graphs to identify global thinning in the RNFL by calculating a trend over time (diffuse change). Spectral-domain OCT provides many potential advantages for glaucoma diagnosis and follow-up. Axial resolution of commercially available units is currently close to 5 μm, and research systems are approaching 2 to 3 μm, which could lead to the detection of subtle changes in the RNFL and the optic disc and result in a better ability to detect disease progression. Moreover, the higher scan acquisition speed reduces artifacts and might help to obtain more accurate measurements, which also contributes to reduced measurement variability. Imaging technologies have some limitations. Quality of scans and the location of scan circle affects accuracy of the measurements, 19,20 these instruments yield worse diagnostic ability in small and large optic discs, 21,22 and there is not general agreement regarding the optimum criteria for glaucoma diagnosis and follow-up. Nowadays, there is no a single imaging instrument that outperforms the others in differentiating patients with glaucoma from healthy individuals. Bibliografia 1) American Academy of Ophthalmology Glaucoma Panel. Preferred Practice Pattern. Primary open-angle glaucoma. San Francisco, CA, American Academy of Ophthalmology 3, 2005 2) Quigley HA. Neuronal death in glaucoma. Prog Retin Eye Res 18: 39-57, 1999 3) Quigley HA, Miller NR, George T. Clinical evaluation of nerve fiber layer atrophy as an indicator of glaucomatous optic nerve damage. Arch Ophthalmol 98: 1564-1571, 1980 4) Sommer A, Katz J, Quigley HA, et al. Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. Arch Ophthalmol 109: 77-83, 1991 5) Jonas JB, Dichtl A. Evaluation of the retinal nerve fiber layer. Survey of Ophthalmology 40: 369-378, 1996 6) Sommer A, Quigley HA, Robin AL, et al. Evaluation of nerve fiber layer assessment. Arch Ophthalmol 102: 1766-1771, 1984 7) Medeiros FA, Zangwill LM, Bowd C, et al. Comparison of scanning laser polarimetry using variable corneal compensation and retinal nerve fiber layer photography for detection of glaucoma. Arch Ophthalmol 122: 698-704, 2004 8) Zangwill LM, Bowd C, Berry CC et al. Discriminating between normal and glaucomatous eyes using the Heidelberg Retina Tomograph. GDx Nerve Fiber Analyzer, and Optical Coherence Tomograph. Arch Ophthalmol 119: 985-993, 2001 9) Weinreb RN, Dreher AW, Coleman A, Quigley HA, Shaw B, Reiter K. Histopathologic validation of Fourierellipsometry measurements of retinal nerve fiber layer thickness. Arch Ophthalmol 108: 557-560, 1990 10) Morgan JE, Waldock A, Jeffery G, Cowey A. Retinal nerve fiber layer polarimetry: histological and clinical comparison. Br J Ophthalmol 82: 684-690, 1998 11) Reus NJ, Lemij HG. Diagnostic accuracy of the GDx VCC for glaucoma. Ophthalmology 111: 1860-1865, 2004 12) Zhou Q, Weinreb RN. Individualized compensation of anterior segment

birefringence during scanning laser polarimetry. Invest Ophthalmol Vis Sci 43: 2221-2228, 2002 13) Greenfield DS, Knighton RW, Feuer W, Schiffman J, Zangwill L, Weinreb RN. Correction for corneal polarization axis improves the discriminating power of scanning laser polarimetry. Ophthalmology 108: 1065-1069, 2002 14) Reus NJ, Colen TP, Lemij HG. Visualization of localized retinal nerve fiber layer defects with the GDX with individualized and with fixed compensation of anterior segment birefringence. Ophthalmology 110: 1512-1516, 2003 15) Reus NJ, Zhou Q, Lemij HG. Enhanced imaging algorithm for scanning laser polarimetry with variable corneal compensation. Invest Ophthalmol Vis Sci 47: 3870-3877, 2006 16) Medeiros FA, Bowd C, Zangwill LM, Patel C, Weinreb RN. Detection of glaucoma using scanning laser polarimetry with enhanced corneal compensation. Invest Ophthalmol Vis Sci 48: 3146-3153, 2007 17) Swanson EA, Izatt JA, Hee MR, et al. Invivo retinal imaging by optical coherence tomography. Optics Letters 18: 1864-1866, 1993 18) Fercher AF, Hitzenberger CK, Drexler W, Kamp G, Sattmann H. In-vivo optical coherence tomography. American Journal of Ophthalmology 116: 113-115, 1993 19) Cheung CY, Leung CK, Lin D, Pang CP, Lam DS. Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography. Ophthalmology 115: 1347-1351, 2008 20) Gabriele ML, Ishikawa H, Wollstein G, et al. Optical coherence tomography scan circle location and mean retinal nerve fiber layer measurement variability. Invest Ophthalmol Vis Sci 49: 2315-2321, 2008 21) Medeiros FA, Zangwill LM, Bowd C, Sample PA, Weinreb RN. Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma. Invest Ophthalmol Vis Sci 47: 1008-1015, 2006 22) Rao HL, Leite MT, Weinreb RN, et al. Effect of disease severity and optic disc size on diagnostic accuracy of RTVue spectral domain Optical Coherence Tomograph in glaucoma. Invest Ophthalmol Vis Sci. In Press. 229