Instructions for Use. Engineered for Life

Similar documents
Fig 1. How to use the In-Check M. Clinically Effective Flow Rate L/Min

Advanced Inhaler Technique. Learning Outcomes. Disclosure 1.1. Belgian Chocolate, French Champagne and Inhaled Medication: Too Good To Waste?

Pocket Guide to Inhaler Technique A Step-By-Step Guide for Healthcare Professionals

COPD Device Workshop. Summary. Role of inhaler device in COPD. Why use inhaler device in COPD?

Appendix E: Device Technique

Appendix M: Device Technique

Patient. Device Clinician. Safety & efficacy

Inhaler technique reminder cards

Smart asthma therapy. Patient information Spacer inhaling aid for metered-dose aerosol inhalers

2008 IPAC-RS Conference Doing the Right Thing Science, Quality and Patient Focus

Guide to Inhaled Treatment Choices

Guide to Inhaled Treatment Choices

Respiratory Care 2. Clinical Skills School of Medicine 2015/16

Beclometasone dipropionate (BDP) Prophylactic management of mild, moderate or severe asthma in adults

I. Subject: Medication Delivery by Metered Dose Inhaler (MDI)

MDI Bonanza. Dwayne Griffin, DO

Pulmonary deposition of inhaled drugs

How can I benefit most from my COPD medications?

What you need to know about inhalers and how to use them Henry Chrystyn PhD, FRPharmS and David Price MA, MRCGP, DRCOG

NHS Northern, Eastern and Western Devon Clinical Commissioning Group NHS South Devon and Torbay Clinical Commissioning Group

How to Use Inhaled Medications for Asthma and COPD

Your Inhaler Devices & You

How to use your QVAR RediHaler (beclomethasone dipropionate)

Using an Inhaler and Nebulizer

Can all patients with COPD use the correct inhalation flow with all inhalers and does training help?

University of Groningen. Technology in practice Lexmond, Anne

Health Professional Manual

The Novolizer s : overcoming inherent problems of dry powder inhalers

Aerosol Delivery Devices

Breezhaler. Open to see clear capsule. How do I use my Breezhaler? Care of my Breezhaler

Inhalation Therapy. Inhalation Therapy

An update on inhalation devices

Inhaler Standards and Competency Document

GMMMG Asthma Formulary Inhaler Options August 2017

Dry Powder Inhaler. Developing an Efficient. 3M Conix DPI. White Paper / Spring Proven Solutions that Enable Your Success

Asthma. If an Ambulance is required - call immediately - do not delay. H & A Training PL RTO No:90871

Delay Between Actuation and Shaking of a Hydrofluoroalkane Fluticasone Pressurized Metered-Dose Inhaler

RDD Europe 2009 Workshop

Inhaled therapy in elderly COPD patients; time for re-evaluation?

Metered Dose Inhaler (MDI)

Information for Patients. Inhaler devices for routine treatment of chronic asthma in older children (aged 5-15 years)

A multitude of devices

Inhaler Devices. Ask the patient/carer to demonstrate the technique and correct accordingly at every opportunity.

MOTHER TERESA CATHOLIC COLLEGE ASTHMA POLICY Year Drafted: 2017 Review: 2019

BEDFORDSHIRE AND LUTON JOINT PRESCRIBING COMMITTEE

Assessing the role of breathing simulators in OIP testing

The problem with critical and non-critical inhaler errors

Instructions for Use ALVESCO [ael- ves-koʊ] (ciclesonide) Inhalation Aerosol

Concurrent Use Of Metered Dose Inhalers Without Spacer And Dry Powder Inhalers By Asthmatic Children Adversely Affect Proper Inhalation Technique

Q. What are metered-dose inhalers? A. These are devices that dispense medicines directly into the lungs, in the form of a mist or aerosol in a

NEBULIZERS, METERED DOSE INHALERS, AND DRY POWDER INHALERS

ADDITIONAL TECHNOLOGIES FOR PRESSURIZED METERED DOSE INHALERS. Steve Newman Scientific Consultant Nottingham, UK

Inhalation devices, proper technique and cleaning

Patient Guide. This information is for patients prescribed Sereflo TM inhaler

Appropriate use of a dry powder inhaler based on inhalation flow pattern

Patient Information ARNUITY ELLIPTA (ar-new-i-te e-lip-ta) (fluticasone furoate inhalation powder) for oral inhalation use What is ARNUITY ELLIPTA?

MEDICATION GUIDE. ADVAIR [ad vair] HFA 45/21 (fluticasone propionate 45 mcg and salmeterol 21 mcg) Inhalation Aerosol

Understanding COPD Medications

Asthma Policy February 2014

Skills Checklist Manual

ASTHMA POLICY KYABRAM P-12 COLLEGE

Device Design Similarity

My Asthma Log. Tommy Traffic Light. NHS Number: Name:

CAPSULE-BASED DRY POWDER INHALERS, AN OPTIMAL SOLUTION FOR DIFFERENT INSPIRATIONAL RATES

AEROSOL THERAPY: THE PRACTICALITIES

NebuTech nebulizer from Salter. Striving to be #1 IN PATIENT SATISFACTION. To help you and your patients. easy. breathe

Niche News August 2017 August 2017

Beclazone CFC-Free Inhaler

Your Guide to MANAGING ASTHMA

Peak inspiratory flow through the Genuair â inhaler in patients with moderate or severe COPD

MEET THE DRIVING FORCE IN NEBULIZER THERAPY... Matched Nebulizer Compressor System

10/18/2012. Penn State University Children s Hospital JODIE STABINSKI CRNP MSN AE-C

Patient Education and Adherence to Aerosol Therapy

Asthma Policy Kindergarten Cluster Page 1 of 5

Seheult et al. SpringerPlus 2014, 3:496 a SpringerOpen Journal

Protocol for the use of emergency salbutamol inhalers in schools

...Porta-neb matched systems from Respironics (UK)

Asthma and pre-school wheeze management

INTRODUCTION. Asthma Drug Delivery - 1

Alvesco contains a medicine called ciclesonide, which belongs to a family of medicines called corticosteroids.

Respiratory Health. Asthma and COPD

COPD Program - Group session 1 Facilitator documents. May 2013

INHALERS for COPD INTRODUCTION. Types of inhalers. Inhaler technique. MDIs for COPD WET AEROSOLS. Dr Christopher Worsnop

L. Borgström*, E. Bondesson*, F. Morén**, E. Trofast*, S.P. Newman +

COPD RESOURCE PACK Section 5. Drug Treatment & Inhalers in Stable COPD

Care and Use of Nebulisers

Procedure/ Care Plan for Domiciliary Care Workers/ Support Workers - Assisting a Service User to use an Inhaler (Adult)

Development of a Dry Powder Multi-dose Inhaler using Computational Modeling

acapella vibratory PEP Therapy System Maximizing Therapy Effectiveness, Empowering Patient Compliance

Paediatric pulmonary drug delivery: considerations in asthma treatment

Latex Free. An affordable, easy to use, high density, small volume nebulizer with a breath enhanced design! Breath Enhanced High Density Jet Nebulizer

Darland High School Policy

PATIENT INFORMATION. ADVAIR DISKUS [AD vair DISK us] (fluticasone propionate and salmeterol inhalation powder) for oral inhalation

Small Volume Nebulizer Treatment (Hand-Held)

PACKAGE LEAFLET: INFORMATION FOR THE USER. Bricanyl Turbohaler 0.5 mg/dose terbutaline sulphate

Medescan Nebuliser Med - S600A Instructions Manual

The Victorian Schools Asthma Policy Revised January 2010

your breathing problems worsen quickly. you use your rescue inhaler, but it does not relieve your breathing problems.

ADASUVE (LOXAPINE) INHALATION POWDER. EDUCATION PROGRAM for HEALTHCARE PROFESSIONALS

Transcription:

Instructions for Use Engineered for Life

Instructions for Use Consult Instructions for Use. This product complies with the essential requirements of the medical devices directive (93/42/EEC). Compliance has been verified by UK notified body per 0120 (SGS Yarsley). Introduction The In-Check DIAL is an inhalation airflow meter that can help educate and assess patients who use inhaler devices. Inhaler devices are designed to deliver medication to the respiratory tract, and the speed of inhalation through them (the inspiratory flow) can have a significant effect on the quantity of drug delivered and the clinical efficacy of the product. The In-Check DIAL is designed to simulate the internal resistance of several common inhaler devices, and measure inspiratory flow. These measurements enable the healthcare professional to encourage patients to modify their inspiratory technique (by inhaling with more, or less effort), in order to achieve a flow rate consistent with clinical efficacy. The green bars show the clinically effective flow ranges for each of these inhaler devices. These bars do not imply any comparison between devices. Patients that cannot achieve the suggested inspiratory flow for their inhaler may not gain maximum benefit from their prescribed medication, and healthcare professionals may wish to take this factor into account when selecting with the patient, the device that is the most suitable. Inspiratory Flow and Clinically Effective Flow Range The inspiratory flow through an inhaler is one of the factors that will influence the clinical effect of the drug delivery from that device. The most effective delivery occurs when the patient achieves a flow within the clinically effective flow range. Flow rates outside this range, may result in a diminished deposition and clinical efficacy. Inhaler devices Drug delivery from the various types of inhaler devices is produced by different methods. Inhaler devices are designed to deliver drug particles of a certain size to the small airways during inhalation. Particles of this size (generally agreed to be approximately between 1 and 5 microns) are known as the respirable fraction. The particles are either in aerosol (in a suspension or a solution) or dry powder form. Pressurised Metered Dose Inhalers (pmdis) With most pmdis, the aerosol is delivered under pressure at high speed (often over 90 kilometres per hour). The inhalation should be timed with actuation of the device and should be slow and steady. Inhaling too fast may cause a greater proportion of the aerosol to impact at the back of the throat and be subsequently swallowed, thus reducing the beneficial clinical effect and increasing the potential for local and systemic side effects. 1

With the majority of pmdis, manual depression of the drug canister actuates the drug delivery. However, with breath-actuated metered dose inhalers (e.g. Autohaler ), the aerosol is released by mechanical actuation, triggered by the patient breathing in through the device at any flow rate above a minimum level. At inspiratory flows below this, the patient will not receive any of the medication, because a dose will not be released. pmdis with Holding Chamber/Spacer It is recognised that the optimum inhalation technique for using a pmdi with a holding chamber/spacer is a slow inhalation (30 to 60 l/min). As the resistances of the values of most chamber/spacer devices are low, the In-Check DIAL can be set to conventional pmdi to provide an approximate resistance for inspiratory flow measurements to be made. Dry Powder Inhalers (DPIs) Drug delivery from DPIs is triggered by inhaling through the device. A metered quantity of powder is drawn into the airflow, and follows a specific pathway within the inhaler, through internal features that create a resistance that is designed to break up the medication into particles of a respirable size. As the internal design of each DPI is different, and the formulation of medication is not identical, the resistance the patient encounters when inhaling is different from device to device. The effort required for the patient to achieve a given inspiratory flow will increase as the internal resistance of the device increases. For the same patient effort, the higher the resistance the lower the resulting inspiratory flow. As the great majority of asthma medication is delivered via inhalers, correct inhaler technique is an important factor in the management of this disease. Patients require their medication for both short-term relief and long-term prevention, and the delivery of these drugs to the lungs is affected by inspiratory flow. Assessing inspiratory flow is an important aspect of device education and review. Determining whether or not a patient can obtain the appropriate inspiratory flow rate for a device can be an important factor in improving inhaled treatment. In-Check DIAL The In-Check DIAL is a low-range inspiratory flow meter (15 to 120 l/min) that has a selectable resistance, calibrated to enable the measurement of airflow as if the patient was using the following inhalers:- Multi-dose powder inhaler (Accuhaler / Diskus ) The dial has one more position - one where the orifice is entirely closed. The Conventional pmdi position can be used to approximate the resistance when a conventional pmdi is attached to a holding chamber or spacer device. Should new types of inhaler become available, then In-Check DIAL can be adapted to measure the new inspiratory flow, by placing a resistance adaptor (as used in the In-Check Inhaler Assessment Kit) in the mouthpiece, and selecting Conventional pmdi on the dial. 2 Turbulent flow powder inhaler (old style) (Turbohaler / Turbuhaler ) Turbulent flow powder inhaler (new style) (Turbohaler / Turbuhaler ) Conventional pressurised metered dose aerosol (Conventional pmdi) Auto release pmdi inhaler (Autohaler ) Auto release pmdi inhaler (Easi- Breathe )

IMPORTANT As with any inhalation device, it is important to check for loose foreign objects before the device is used. The transparent material used in the construction of the In-Check DIAL enables the user to make a visual check before inhalation. Patients should be prevented from exhaling through the device prior to use. To reset the In-Check DIAL Hold the instrument vertically with the mouthpiece uppermost, so that the rounded end of the meter can be tapped against the other hand or a horizontal surface, such as a table. A hard tap will dislodge the magnetic resetting weight, which will return the red cursor to a start position. When this has happened, the meter must turn through 180 degrees to return the magnetic weight to its resting position. Do Not try to reset the In-Check as if it were a mercury thermometer this action causes serious damage to the piston and pointer How to use the In-Check DIAL 1. Reset the In-Check DIAL 2. Align the scale with the desired inhaler device an audible click should be heard. 3. Attach a clean mouthpiece (small mouthpieces can be used with thesupplied adaptor). Disposable one-way inspiratory mouthpieces are preferred. 4. Ask the patient to exhale fully. 5. Seal lips around the mouthpiece. According to the inhaler chosen, instruct the patient to inhale in the manner recommended by the manufacturer. There is a reminder of inhalation technique beside each inhaler icon on the laminated card. 6. Record the inspiratory flow from the position of the red cursor against the scale. Reset, and repeat two more times, ensuring correct technique each time. 7. Compare values achieved with target flows for that device. To operate an inhaler device correctly, the patient should be able to achieve a flow rate within the clinically effective range. 8. If after repeated training the patient is not able to achieve these values, then the healthcare professional may wish to assess the patient s ability to use an alternative type of inhaler. Performance Accuracy Accuracy +/- 10% or 10 l/min (whichever is the greater) and repeatability of +/- 5 l/min. Cleaning your In-Check DIAL Where local infection control guidelines exist, these should be respected. Immerse In-Check DIAL in warm (but not hot) mild detergent solution for 2-3 minutes (maximum 5 minutes). Agitate the meter to ensure thorough cleaning. Rinse in warm water and shake to remove any excess water. It is important to rinse thoroughly to prevent salt spots appearing on the inside of the body and the spindle. To shake excess water from the In-Check, hold only at the end furthest away from the DIAL selector. Allow to dry thoroughly before using again. The expected life of the In-Check DIAL, in normal use, is two years. To maintain hygene the In-Check DIAL should be used with disposable inspiratory one-way mouthpieces. If use of this product is governed by local infection control guidance, that guidance should be respected in the absence of local guidance. 3

Interpreting information from the In-Check DIAL In-Check DIAL was modified in September 2010, in response to customer feedback, to provide information about inspiratory flow rates that are associated with clinical efficacy. The new scale is shown above. The information provided is for guidance only. It does not imply that any particular product will be clinically effective. There are other aspects than inspiratory flow that contribute towards clinical efficacy. The information is based on published clinical studies. In some cases studies may have been performed on a particular formulation in a specific device and may be suggestive that other formulations will behave similarly. The DPIs have been represented in a single block from 30-90 L/Min because the clinical studies support this (see details on laminated card). Laboratory studies also demonstrate that DPIs have a degree of flow-dependence, meaning that improved delivery is achieved at higher flow rates. This does not always equate toimproved clinical efficacy. A pale arrow represents the intention that flow rates of a higher level may be beneficial for DPIs. The pmdis have been represented in a single block from 30-60 L/Min because the clinical studies support this (see details on laminated card). The pale arrow is pointed in the opposite direction for pmdis, indicating that a slower rather than higher flow rate is beneficial in this type of inhaler. The products are individually represented on the laminated card. 4

Bibliography for In-Check (Please note that references for Clinical Efficacy of different inhaler systems are provided on the laminated card.) Banno M, Ibata H, Niimi T, Sato S, Matsushita R. The Usefulness of Inspiratory Flow Rate during Inhalation Corticosteroid Therapy in Asthma. Respiration 2009;78:387-392. Janssens W, Vanden Brande P, Hardeman E, et al. Inspiratory flow rates at different levels of resistance in elderly COPD patients. Eur Respir J. 2008;31:78 83. Zhang QL, Zheng JP, Pan WH, He H, Chen GL, An JY, Yuan LF, Luo DF. Peak inspiratory flow generated through different analogue dry powder inhalers in Shenzhen healthy preschool children. Zhonghua Er Ke Za Zhi. 2008 Feb;46(2): 98-103. Raid A.M. R.A.M. Al-Showair, Walid Y. W.Y. Tarsin, Khaled H. K.H. Assi, Stanley B. S.B. Pearson, Henry Chrystyn. Can all patients with COPD use the correct inhalation flow with all inhalers and does training help? Respiratory Medicine - November 2007 Vol. 101, Issue 11, Pages 2395-2401. Walid Y. Tarsin, Stanley B. Pearson, Khaled H. Assi, Henry Chrystyn. Emitted dose estimates from Seretide(R) Diskus(R) and Symbicort(R) Turbuhaler(R) following inhalation by severe asthmatics. International Journal of Pharmaceutics, Volume 316, Issues 1-2, 19 June 2006, Pages 131-137. K.N. Desager, J. Geldhof, R. Claes, W. De Backer. Measurement of Inspiratory Flow Through Three Different Dry Powder Inhalation Devices Using In-CheckTM in Children with Asthma. Pediatric Asthma, Allergy & Immunology. March 2006, Vol. 19, No. 1: 6-13. Tiddens HA, Geller DE, Challoner P, Speirs RJ, Kesser KC, Overbeek SE, Humble D, Shrewsbury SB, Standaert TA. Effect of dry powder inhaler resistance on the inspiratory flow rates and volumes of cystic fibrosis patients of six years and older. J Aerosol Med. 2006 Winter;19(4):456-65. Andrea S. Melani; Letizia S. Bracci; Marcello Rossi. Reduced Peak Inspiratory Effort through the Diskus and the Turbuhaler due to Mishandling is Common in Clinical Practice. Clin Drug Invest. 2005;25(8):543-549. Amirav I, Newhouse MT, Mansour Y. Measurement of peak inspiratory flow with In-Check DIAL device to simulate low-resistance (Diskus) and high-resistance (Turbohaler) dry powder inhalers in children with asthma. Pediatr Pulmonol. 2005 May;39(5):447-51. Y. Adachi, Y.S. Adachi, T. Itazawa, J. Yamamoto, G. Murakami, T. Miyawaki. Measurement of peak inspiratory flow rates with an In-CheckTM meter to identify preschool children s ability to use dry powder inhalers; Diskus and Turbuhaler. The Journal of Allergy and Clinical Immunology - February 2004 (Vol. 113, Issue 2,

In-Check Dial (Info scale, 6 T & S, UK) Ref. 3109979 In-Check Dial Instruction Booklet (6 T & S, UK) Ref. 1902806 In-Check Inhaler Assessment Kit Ref. 3109760 In-Check Peak Inspiratory Flow Meter (Oral) Ref. 3109750 Disposable one-way mouthpieces (Inspiratory, 5 x 20) Ref. 3122061 Disposable one-way mouthpieces (Inspiratory, bulk, 200) Ref. 3122063 Disposable Cardboard Mouthpieces (Adult, 5 x 20) Ref. 3125030 Disposable Cardboard Mouthpieces (Adult, 500) Ref. 3122003 Disposable Cardboard Mouthpieces (Child, 500) Ref. 3123030 Universal Plastic Mouthpieces (Sterilisable, 15 s) Ref. 3103095 Adult to Paediatric Mouthpiece Adaptor Ref. 3105027 NOTE Please contact manufacturers for additional information. Accuhaler and Diskus are trademarks of the GlaxoSmithKline group of companies. Turbuhaler and Turbohaler are trademarks of AstraZeneca. Autohaler is a trademark of 3M. Easi-Breathe is the registered trade mark of Norton Healthcare Ltd. Clement Clarke International Limited Edinburgh Way Harlow Essex CM20 2TT UK Tele: +44 (0)1279 414969 Fax: +44 (0)1279 456300 email: resp@clement-clarke.com www.clement-clarke.com Copyright 2010 Clement Clarke International Ltd. Issue 3 5/13 Part no. 1902806