Scholars Research Library

Similar documents
Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

Sci Pharm

A stability indicating RP-HPLC method for simultaneous estimation of darunavir and cobicistat in bulk and tablet dosage form

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

ANALYTICAL TECHNIQUES FOR THE QUALITY OF ANTI- AIDS DRUGS

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

Stability indicating RP-HPLC method development and validation of Etizolam and Propranolol hydrochloride in pharmaceutical dosage form

Development and validation of related substances method for Varenicline and its impurities

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

Pelagia Research Library

International Journal of Pharma and Bio Sciences

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF LACOSAMIDE IN BULK AND ITS PHARMACEUTICAL FORMULATION

A simple validated RP-HPLC method for quantification of sumatriptan succinate in bulk and pharmaceutical dosage form

Scholars Research Library. Der Pharmacia Lettre, 2016, 8 (6): (

Available online at Scholars Research Library

DEVELOPMENT AND VALIDATION OF NEW HPLC METHOD FOR THE ESTIMATION OF PALIPERIDONE IN PHARMACEUTICAL DOSAGE FORMS

Method Development And Validation Of Losartan Potassium And Hydrochlorothiazide In Comined Dosage Form By RP-HPLC

Available online at Scholars Research Library

Pelagia Research Library

Volume 2 (6), 2014, Page CODEN (USA)-IJPRUR, e-issn: International Journal of Pharma Research and Health Sciences

Mohammed and Rudwan, IJPSR, 2016; Vol. 7(6): E-ISSN: ; P-ISSN:

Scholars Research Library

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

Scholars Research Library

Research Article DEVOLOPMENT OF RP-HPLC METHOD AND IT S VALIDATION FOR SIMULTANEOUS ESTIMATION OF SITAGLIPTIN AND METFORMIN

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET

J Pharm Sci Bioscientific Res (4): ISSN NO

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

Hyderabad, India. Department of Pharmaceutical Chemistry, Glocal University, Saharanpur, India.

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BACLOFEN IN BULK AND PHARMACEUTICAL DOSAGE FORMS

Estimation of zolmitriptan by a new RP-HPLC method

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2

Isocratic Reversed Phase Liquid Chromatographic Method Validation for the Determination of Cilostazol in Pure and Formulations

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

Scholars Research Library

Scholars Research Library. Der Pharmacia Lettre, 2015, 7 (5):44-49 (

METHOD DEVELOPMENT AND VALIDATION OF STABILITY INDICATING METHOD FOR ANALYSIS OF LOSARTAN POTASSIUM IN BULK DRUG AND DOSAGE FORM FORMULATION

International Journal of Farmacia

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

Abstract. G. D. Patil 1, P. G. Yeole 1, Manisha Puranik 1 and S. J. Wadher 1 *

VALIDATED RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF DEXAMETHASONE AND GRANISETRON IN COMBINED DOSAGE FORMS

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Pankti M. Shah et al, Asian Journal of Pharmaceutical Technology & Innovation, 04 (17); 2016; 07-16

Dhull Rohit, Kumar Sanjay, Jalwal Pawan Department of Chemistry, OPJS Churu, Rajasthan, India

NOVEL RP-HPLC METHOD. B.Lakshmi et a. concentration range KEY INTRODUCTION. Diltiazem is used to. . It works by of contractionn of the. (dilate).

World Journal of Pharmaceutical Research

Comparison of conventional HPLC with UPLC method for determination of albuterol sulfate and it s impurities in pharmaceutical formulation

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF FEBUXOSTAT IN BULK AND TABLET DOSAGE FORM

A Validated Stability Indicating RP-HPLC Method for Simultaneous Estimation of Valsartan and Clinidipine Combined Tablet dosage forms

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS

Journal of Chemical and Pharmaceutical Research, 2013, 5(1): Research Article

Estimation of Emtricitabine in Tablet Dosage Form by RP-HPLC

ISSN: ; CODEN ECJHAO E-Journal of Chemistry 2011, 8(3),

ISSN (Print)

HPTLC Determination of Atomoxetine Hydrochloride from its Bulk Drug and Pharmaceutical Preparations

Scholars Research Library

SIMULTANEOUS QUANTIFICATION OF TELMISARTAN AND METOPROLOL SUCCINATE IN TABLETS BY LIQUID CHROMATOGRAPHY

Validated RP-HPLC Method for the Estimation of Esomeprazole Enteric Coated Tablets

Method Development and Validation for the Estimation of Saroglitazar in Bulk and Pharmaceutical Dosage Form by RP-HPLC

36 J App Pharm Vol. 6; Issue 1: 36-42; January, 2014 Rao et al., 2014

Development and validation of RP-HPLC method for simultaneous estimation of gliclazide and metformin in pure and tablet dosage form

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

Analytical Method Development and Validation for the Estimation of Guaifenesin and Dextromethorphan by RP-HPLC

Research Article Simultaneous Estimation of DL-Methionine and Pyridoxine Hydrochloride in Tablet Dosage Form by RP-HPLC

CHAPTER-6 IDENTIFICATION, AND CHARACTERISATION OF DEGRADATION IMPURITY IN VALSARTAN TABLETS

Int. J. Pharm. Sci. Rev. Res., 30(1), January February 2015; Article No. 32, Pages:

International Journal of Drug Research and Technology

Volume 6, Issue 1, January February 2011; Article-021

Pelagia Research Library

Method Development and Validation for Simultaneous Estimation of Atorvastatin and Ezetimibe in Pharmaceutical Dosage Form by HPLC

METHOD DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR DETERMINATION OF NEW ANTIDIABETIC AGENT LINAGLIPTIN IN BULK AND IN PHARMACEUTICAL FORMULATION

Rao and Gowrisankar: Stability-indicating RP-HPLC Method for Pseudoephedrine, Ambroxol and Desloratadine

International Journal of Medicine and Pharmaceutical Research. International Journal of Medicine and Pharmaceutical Research

Development of RP-HPLC Method for Estimation of Valsartan and Hydrochlorothiazide in Tablets

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS

Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

AMERICAN JOURNAL OF BIOLOGICAL AND PHARMACEUTICAL RESEARCH

ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR DETERMINATION OF ROSUVASTATIN CALCIUM IN BULK AND PHARMACEUTICAL DOSAGE FORM

CHAPTER 2 SIMULTANEOUS DETRMINATION OF ANASTROZOLE AND TEMOZOLOMIDE TEMOZOLOMIDE CAPSULES 20 MG AND ANASTROZOLE TABLETS 1 MG

Airo International Research Journal ISSN : Volume : 7 October 2015

Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms

Corresponding Author:

MEDAK DIST. ANDHRA PRADESH STATE, INDIA. Research Article RECEIVED ON ACCEPTED ON

Ankit et al Journal of Drug Delivery & Therapeutics; 2013, 3(2), Available online at RESEARCH ARTICLE

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations

Pelagia Research Library. Spectrophotometric method for simultaneous estimation of Valsartan and Hydrochlorothiazide in combined tablet dosage form

ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF DILTIAZEM HYDROCHLORIDE IN BULK AND PHARMACEUTICAL DOSAGE FORM BY RP- HPLC

Available online Research Article

Journal of Chemical and Pharmaceutical Research

International Journal of Pharmacy and Pharmaceutical Sciences. Research Article

Available online at Scholars Research Library

Transcription:

Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2011: 3 (5) 160-167 (http://scholarsresearchlibrary.com/archive.html) ISSN 0974-248X USA CODEN: DPLEB4 Isocratic RP-HPLC method validation and verification of losartan potassium in pharmaceutical formulations with stress test stability for drug substance Mohammed Mustafa Ali Siddiqui a *, Syed Sultan Qasim b and Ehab Youssef Abueida c Organic Research Laboratory, Maulana Azad college, Dr. Rafiq Zakariya Campus Aurangabad, M.S India ABSTRACT This paper describes the validation of an isocratic HPLC method for the assay of Losartan Potassium Tablets and the evaluation of the stability of drug substance after stress test by Photodiode array detection. The HPLC separation was achieved on a liquid chromatogram is equipped with a 254 nm detector and a 4.6 25 mm column that contains 5 µm packing L 1 (Hypersil BDS C 18 4.6 250 mm, 5 µm column is suitable). A mixture of ammonium dihydrogen phosphate buffer ph 3.0 and acetonitrile (65:35) as a mobile phase, the flow rate is about 1.5 ml per minute. Chromatograph the Standard preparation, and record the peak response as directed under procedure: the tailing factor for the analyte peak is not more than 3.0 and the relative standard deviation of replicated injections is not more than 2%. Keywords: Losartan Potassium Tablets, Validation, RP-HPLC, Stability. INTRODUCTION Losartan potassium, a potassium salt of 2-Butyl-4-chloro-1-[[2 -(1H-tetrazol-5- yl) [1,1 biphenyl]-4-yl]methyl]-1h-imidazole-5-methanol (Figure No.1 ), represents the first of a new class of orally active non-peptide angiotensin II (Type AT1) receptor antagonists employed in the management of essential hypertension. [1,2] Figure No. 1: Chemical Structure of Losartan. 160

The individual determination of losartan has been carried out in tablets by capillary electrophoresis and super- critical fluid chromatography [3, 4], in bulk [5], by HPLC & LC- MS/MS [6-8] and UV-Spectrophotometric method [9], HPTLC [3,10] and with its active metabolite in biological fluid by HPLC. [11-14], HPLC method for determination of Losartan potassium in combination with other drugs [15-19]. MATERIALS AND METHODS Reagents and Chemicals HPLC grade anhydrous ammonium hydrogen orthophosphate, Orthophosphoric acid, Acetonitrile from Merck. Water was deionised and purified by a Milli- Q water purification system was used to prepare the mobile phase and sample and standard solutions. A reference standard of Losartan Potassium was procured from Hetero Pharma. Chromatographic equipment and conditions The development and validation of the assay is performed on Waters Alliance HPLC system with UV-VIS Detector which include following parts: Fluidics management system (Model: 2695) includes seal wash, degasser, sample heater/cooler and Column heater.uv-vis Detector (Model No: 2487)-Dual wavelength absorbance detector. Empower chromatography data system (Software). The analytical column 4.6 25 mm column that contains 5 µm packing L 1 (hypersil BDS C 18 4.6 250 mm, 5 µm column is suitable). The mobile phase consist of ammonium dihydrogen phosphate buffer ph 3.0 and acetonitrile (65:35) as a mobile phase. The flow rate was 1.5ml/min and detection was performed at 254 nm Procedure for determination of Losartan Potassium in Reference Standard Dissolve about 100 mg, accurately weighed, of Losartan potassium Working Standard in 100 ml of diluent, dilute 10 ml to 100 ml with the diluent.a chromatograms obtained from reference solution is presented in Fig 2. Procedure for determination of Losartan Potassium in Sample Solutions Intermediate Products: Weigh and powder 20 tablet, transfer a portion of powder equivalent to 50 mg Losartan potassium accurately weighed, into 50 ml volumetric flask, complete to volume with the diluent, shake for 30 minutes, centrifuge at 4000 rpm for 10 minutes, and dilute 5 ml to 50 ml with the diluent. Finished Product: Transfer 5 tablets into 250 ml volumetric flask, add 20 ml diluent and sonicate to disintegrate the tablets, complete to volume with diluent, shake for 30 minutes, centrifuge at 4000 rpm for 10 minutes, and dilute 5 ml to 50 ml with the diluent. A chromatograms obtained from reference solution is presented in Fig 3. Procedure for Injecting Reference and Standard Sample: Separately inject equal volumes (about 20µl) of the Standard preparation and the Assay preparation, Calculate the quantity, in mg, of C 22 H 22 ClKN 6 O in the portion of powder or tablets taken by the formula: (CL/D) (r u /r s ) Intermediate 5 (CL/D)(r u /r s ) Finished Product 161

Where C is the concentration, in mg per ml, of Losartan potassium in the Standard preparation, calculated on anhydrous basis, L is the labelled quantity, in mg, of Losartan potassium in each tablet, D is the concentration, in mg per ml, of losartan potassium in Assay preparation based on the labelled quantity per tablet and the extent of dilution. r u and r s are the responses of Losartan potassium obtained from the Assay preparation and the Standard preparation, respectively Fig 2: Chromatogram of Losartan potassium Reference standard. Fig 3: Chromatogram of Losartan potassium in Zargo Tablet Method validation The Method was validated for Specificity, precision (repeatability and intermediate precision), accuracy. RESULTS AND DICUSSION System Suitability solution Having optimised the efficiency of a chromatographic separation the quality of chromatography was monitored by applying the following system suitability tests: capacity factor, tailing factor and theoretical plates. The system suitability method acceptance criteria set in each validation run were: capacity factor >2.0, tailing factor 2.0 and theoretical plates <2000. In all cases the 162

relative standard deviation (R.S.D) for the analyte peak area for two consecutive injections was <2.0 %. A chromatograms obtained from reference substance solution is presented in Fig 4 Figure No.4: Resolution solution of Losartan Potassium and Releated C Figure No. 5: Chromatograms of Placebo Preparation Specificity The excipients in the Tablets contained the following in active ingredients: Microcrystalline cellulose (180 micro meter), Lactose DC, Pregelatinized maize starch, Magnesium stearate, Hydroxypropyl methyl cellulose type 2910 (methocel E5), Polyethylene Glycol 400, Titanium dioxide as excipients Chromatograms of Placebo Tablets solution showed no interference with the main Peak. Chromatograms showed indicated that no excipients or impurities interfered with Losartan Potassium peak. (Refer Figure No. 5 for placebo and Figure No. 3 Sample ). Range of linearity: The linearity of the method was evaluated by a calibration curve in the range of (5.08-15.24mg/ml) which include (5.08, 7.62, 10.16, 12.70, 15.24 mg/ml) of the day (n=5). A calibration curve was constructed by plotting the absorbance versus final concentration of Losartan Potassium, which showed a linear response showing the linear dynamic range over the concentration range 0.5-15µg/ml. 163

Precision (Repeatability and Intermediate Precision) Result of Precision was carried out for a series of six samples for strength of Losartan Potassium Tablets 50 mg, preparation is done by transferring Losartan Potassium standard with placebo preparation described above, on three consecutive days, the repeatability, Mean, CV and recovery were calculated (Table No : 1) Analyst 1 2 Table 1 Results of Precision for Zargo tablet Conc. Response % Recovery mg/100ml Peak area ( 10-6 ) 5% 1 10.52 2.320 102.2 2 10.18 2.255 102.6 3 10.96 2.351 99.4 4 10.60 2.341 102.3 5 9.72 2.113 100.7 6 10.22 2.234 101.3 Sample No. CV ( 2%) CL ( 5.0%) 1.20 101.4 ± 1.3 1 10.02 2.200 100.5 2 10.18 2.250 101.2 3 10.10 2.210 100.2 4 10.10 2.230 101.6 0.55 100.8 ± 0.6 5 10.14 2.238 101.0 6 10.06 2.204 100.3 Overall CV 0.95 Table 2 Results of Accuracy Analyst Conc. mg/100ml Response Peak area ( 10-6 ) % Recovery % Bias ( 5%) Analyst 1 5.74 1.270 101.0 +1.0 10.52 2.306 101.5 +1.5 14.80 3.200 98.9-1.1 Analyst 2 4.94 1.103 102.1 +2.1 10.06 2.206 100.4 +0.4 15.02 3.288 100.2 +0.2 Analyst 3 5.08 1.110 100.2 +0.2 10.22 2.220 99.5-0.5 14.94 3.276 100.5 +0.5 Accuracy: Separately transfer either 25, 50 or 75 mg Losartan potassium, accurately weighed, and 150 mg of placebo preparation into a 50 ml volumetric flask, complete to volume with the diluent, shake for 30 minutes, centrifuge at 4000 rpm for 10 minutes, and dilute 5 ml to 50 ml with the diluent to 75% to 125 % the result showed good recoveries ranging from 98.9% to 101.5. The mean recovery data obtained for each level as well as for all levels combined (Table No: 2) were within the limit. RESULTS AND DISCUSSION The Table below showed the characteristics used during the work with their limits and values obtained. (Table No. 3) Characteristics, their limits and values obtained. Stress test for Stability Accelerated degradation studies were performed to provide an indication of the stability of the drug and specificity of the method. Losartan Potassium reference standard was stressed under conditions that cause degradation included the following Placebo Degradation Preparation, 164

Degradation Products Preparations, Drug Substances Degradation Preparations which involved (Decomposition in solid state and Photolysis in solid state) Table 3 Characteristics Limit Value obtained -%Bias 5% Max. 2.1% Precision: -Coefficient of Variance (CV) 2% 0.95% -Confidence limit (CL) (95%) 5% 1.28% Specificity: -% Interference 2% - -Resolution (R) 5 + Min. 5.8 for impurities -%Recovery 10% (Drop) 12.1% to 25.2% drop Linearity and Range: -Range ±50% of the target conc. 5.08-15.24 mg/100ml -Correlation coefficient (r) 0.98 0.9999 -CV for RF st 3% 0.5% Robustness: -Solution stability (%D) 3% 2.2% -Tailing Factor (T) 3 Max. 1.8 -Recovery 97%-103% 101.1% - 103.8% -CV 3% Max. 1.4% Stress test and its Evaluation: Stability of the Analytical Solutions (Robustness): Standard Preparations: Prepare 3 solutions of one analyst as directed and keep at ambient conditions for 24 hours. Synthetic Preparation: Keep 3 solutions of the precision test of one analyst at ambient conditions for 24 hours RESULTS AND CALCULATION Calculate the % recovery for each analyte in Standard preparations and Synthetic preparations before and after storage, use freshly prepared Standard preparation having target concentration for calculations of the % recovery Determine whether the solutions can be used within 24 hours without the results being affected or for a less period of time. Results of Stability of Solutions (Table No. 4) and Results of Placebo and Placebo Degradation Preparation Specificity Test (Table no. 5) Placebo and Drug Substances Degradation Placebo Degradation No degradation products of Losartan Potassium reference substance was observed after refluxing for 48 hours at 65ºC, both wet and dry at 90 C for 6 hours. Decomposition in Solid State: Expose a quantity of drug substance on a hot plate to achieve decomposition. 165

Table 4 Results of Stability of Solutions Sample Standard Synthetic Conc. (mg/100ml) Response Peak area ( 10-6 ) Found Conc. (mg/100ml) % D ( 3.0%) 11.34 2.468 2.470 11.34 11.27-0.6 9.80 2.099 2.100 9.80 9.58-2.2 10.12 2.215 2.246 10.12 10.25 1.3 10.52 2.320 2.330 10.75 10.64-1.0 10.18 2.255 2.280 10.45 10.41-0.4 10.96 2.351 2.380 10.89 10.86-0.3 Thermal Decomposition in Solutions: Losartan working standard, accurately weighed, in a Petri dish add 5 ml of either 0.5M hydrochloric acid, 0.5M sodium hydroxide or 5% hydrogen peroxide, and incubate at 65 o C for 1hours Temperature Stress Decomposition in Solid State: Expose a quantity of drug substance on a hot plate to achieve decomposition, Acid Stress No degradation products of Losartan Potassium reference substance was observed after refluxing for 12 hours at 65ºC. Base Stress. No degradation products of Losartan Potassium reference substance was observed after refluxing for 12 hours at 65ºC. Peroxide stress No degradation of Losartan Potassium was observed for reference substance stressed in 5 % H- 2O 2. Table No. 5: Results of Placebo and Placebo Degradation Preparation Specificity Test & Table No.6: Results of Specificity Test for Drug Substances Degradation Preparations (Stability Indicating) Table No. 5: Results of Placebo and Placebo Degradation Preparation Specificity Test: Sample/Storage Concentration Response % Interference (mg/100 ml) (peak area) ( 2%) Placebo/25 o C - 0.0 0.0 Placebo/90 o C/ dry 6 hours - 0.0 0.0 Placebo/90 o C/wet/6 hours - 0.0 0.0 Table 6: Results of Specificity Test for Drug Substances Degradation Preparations (Stability Indicating) Degradation Condition/ Time Conc. % Drop % Recovery (mg/100ml) ( 10%) Melting/60 minutes 10.16 82.0-18.0 1 M HCl/ 12 hours/ 65 o C 10.46 74.8-25.2 1 M NaOH/ 12 hours/ 65 o C 10.48 102.0-5% H 2 O 2 / 12 hours/ 65 o C 9.97 87.9-12.1 166

CONCLUSION The Proposed method for the assay of Losartan Potassium Tablets is very simple and rapid. The method was validated for specificity, linearity, precision, accuracy and robustness. Although the method could effectively separate the drugs from its degradation products, further studies should be performed in order to use it to evaluate the stability of pharmaceutical formulation Acknowledgement The authors wish to thank Mr. Salim Sawant and Mohd. Waheed of Neobiocon for their valuable contribution during the work. REFERENCES [1] Smith, R.D., et al Rev. Pharmacol. Toxicol., 1992, 32, 135. [2] Chiu, A.T., et al J. Pharmacol. Exp. Ther., 1990, 252, 71 [3] McCarthy KE, Wang Q, Tsai EW, Gilbert RE, Ip DP, Brooks MA. J Pharm Biomed Anal. 1998;17:671 7. [4] Williams RC, Alasandro MS, Fasone VL, Boucher RJ, Edwards JF. J Pharm Biomed Anal. 1996;14:1539 46. [5] Prabhakar AH, Giridhar R. J Pharm Biomed Anal. 2002;27:861 6. [6] Ansari M, Kazemipour M, Khosravi F, Baradaran M. Chem Pharm Bull. 2004;52:1166 70. [7] Jalalizadeh H, Souri E, Farsam H, Ansari M.A, Iranian J Pharmacol Ther. 2003; 2: 18 21 [8] Yeung PK, Jamieson A, Smith GJ, Fice D, Pollak PT. Int J Pharm. 2000; 204:17 22. [9] Lastra OC, Lemus IG, Sanchez HJ, Perez RF. J Pharm Biomed Anal. 2003; 33:175 80. [10] Panchal HJ, Suhagia BN. Acta Chromatogr. 2010; 22: 173 [11] Furtek CI, Lo MW. J Pharm Biomed Anal. 1997;15:1021 9. [12] Polinko M, Riffel K, Song H, Lo MW. J Pharm Biomed Anal. 2003;33:73 84. [13] Soldner A, Spahn-Langguth H, Mutschler E. J Pharm Biomed Anal. 1998;16:863 73. [14] Iwasa T, Takano T, Hara K, Kamei T. J Chromatogr B Biomed Sci Appl. 1999; 734:325 30. [15] Erk N. Pharm Biomed Anal. 2001; 24: 603 611. doi:10.1016/s0731-7085(00)00434-9 [16] Baig MM, Vaidya VV, Sane RT, Menon SN, Dalvi K. Chromatographia. 2006; 642: 293 [17] Arayne SM, Sultana N, Qureshi F, Siddiqui FA, Mirza AZ, Bahadur SS, Zuberi MH. Chromatographia. 2009; 70: 789 795. [18] Ozkan AS. J Liqu Chromatogr Relat Technol. 2001; 24: 2337 2346. [19] Jadhav V, Mande P, Kadam S. Int J Pharm Res Develop. 2009; 2: 961 963. [20] ICH, Q2 (R1). Validation of Analytical Procedure, Test and Methodology. International Conference on Harmonization, Geneva 2005. [21] ICH, Q2A.Validation of Analytical Procedures, Consensus Guidelines. ICH Harmonized Tripartite Guidelines 1994. [22] ICH, Q2B. Validation of Analytical Procedures: Methodology, Consensus Guidelines. ICH Harmonized Tripartite Guidelines 1996. 167