Shan-yu Qin 1, You Zhou 2 *, Ping Li 3, Hai-xing Jiang 1 * Abstract. Introduction

Similar documents
Suspicious Cytologic Diagnostic Category in Endoscopic Ultrasound-Guided FNA of the Pancreas: Follow-Up and Outcomes

Use and Abuse of Onsite Adequacy for EUS-FNA of the Pancreas

Rapid On-Site Evaluation for Endoscopic Ultrasound- Guided Fine-Needle Biopsy of the Pancreas Decreases the Incidence of Repeat Biopsy Procedures

ROSE in EUS guided FNA of Pancreatic Lesions

Abstract. Introduction. Salah Abobaker Ali

Currently, endoscopic ultrasound-guided fineneedle

Title: EUS-GUIDED FNA: HOW DO I INCREASE THE YIELD? Session No.: 7

Endoscopic ultrasonography (EUS) provides high-resolution

SPECIMEN PREPARATION AND ADEQUACY OF THE MATERIAL

Prospective randomized comparison of a 22G core needle using standard versus capillary suction for EUS-guided sampling of solid pancreatic masses

Original Article. Key words: Cytology, fine-needle aspiration (FNA), pancreatic cancer

Esophageal seeding after endoscopic ultrasound-guided fine-needle aspiration of a mediastinal tumor

Original Article ABSTRACT

P. Thomas Cherian, Prasoon Mohan, Abdel Douiri, Philippe Taniere, Rahul K. Hejmadi & Brinder S. Mahon

EUS-Guided Fine Needle Aspiration with and without Trucut Biopsy of Pancreatic Masses

CASE REPORT. Abstract. Introduction. Case Report

40th European Congress of Cytology Liverpool, UK, 2-5 th October 2016

The Use of Pancreatoscopy in the Diagnosis of Intraductal Papillary Mucinous Tumor Lesions of the Pancreas

Prospective evaluation of EUS-guided fine needle biopsy in pancreatic mass lesions

Impact of endoscopic ultrasound-guided fine needle biopsy for diagnosis of pancreatic masses

MATERIALS AND METHODS INTRODUCTION

Rapid on-site Evaluation of Ultrasound-Guided Fine Needle Aspiration of Hepatic Masses

Diagnostic performance of endoscopic ultrasound-guided fine-needle aspiration in pancreatic lesions

25-gauge histology needle versus 22-gauge cytology needle in endoscopic ultrasonography-guided sampling of pancreatic lesions and lymphadenopathy

Research Article The Utility of Repeat Endoscopic Ultrasound-Guided Fine Needle Aspiration for Suspected Pancreatic Cancer

CASE REPORT. Masakuni Fujii 1*, Masao Yoshioka 1, Takefumi Niguma 2, Hiroaki Saito 1,ToruKojima 2, Soichiro Nose 3 and Junji Shiode 1

ACG Clinical Guideline: Diagnosis and Management of Pancreatic Cysts

Fine-Needle Aspiration Biopsy of Solid Pancreatic Masses: Comparison of CT and Endoscopic Sonography Guidance

Endoscopic ultrasonography in suspected pancreatic malignancy and indecisive CT

Evaluation of AGA and Fukuoka Guidelines for EUS and surgical resection of incidental pancreatic cysts

Histologic diagnosis of pancreatic masses using 25-gauge endoscopic ultrasound needles with and without a core trap: a multicenter randomized trial

The role of endoscopy in the diagnosis and treatment of cystic pancreatic neoplasms

The Risk Factors for Acute Pancreatitis after Endoscopic Ultrasound Guided Biopsy

Outline 11/2/2017. Pancreatic EUS-FNA general aspects. Cytomorphologic features of solid neoplasms/lesions of the pancreas

ORIGINAL ARTICLE. Abdul Haseeb, Linda Jo Taylor, Douglas G. Adler. University of Utah School of Medicine, Salt Lake City, Utah, USA.

needles: a multicenter, prospective, randomized, con Revised_manuscript_for_resubmit-clean_version( Instructions for use

Repeat Thyroid Nodule Fine-Needle Aspiration in Patients With Initial Benign Cytologic Results

Types of IPMN. Pancreas Cysts: An Incidental Finding or Harbinger of Malignancy. Cysts: Early Neoplasia. Mucinous Cystic Lesions. EUS-guided FNA EUS

NEWSLETTER ENDOSONOGRAPHY NEWS LETTER WHY BLOCK THE CELL BLOCK? Immediate Gratification. June Dear Readers:

Endoscopic ultrasound (EUS) has assumed an important role

Cytology for the Endocrinologist. Nicole Massoll M.D

Editorial Process: Submission:11/02/2017 Acceptance:05/19/2018

ORIGINAL ARTICLE. Key Words: effusion; body fluid; cytology; CellprepPlusVR ; ThinPrepVR

The Cytology of Pancreatic Foamy Gland Adenocarcinoma

Performance of novel tissue harmonic echo imaging using endoscopic ultrasound for pancreatic diseases

Fellowship in Cytopathology Department of Pathology. All India Institute of Medical Sciences (AIIMS) Jodhpur, Rajasthan, India

An experimental study to assess the best maneuver when using a reverse side-bevel histology needle for EUS-guided fine-needle biopsy

CENTRE. Stanley Medical College Chennai India

Clinical Outcome for Atypia of Undetermined Significance in Thyroid Fine-Needle Aspirations Should Repeated FNA Be the Preferred Initial Approach?

Rapid on-site evaluation of endoscopic-ultrasound-guided. fine-needle aspiration diagnosis of pancreatic masses.

Feasibility of endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) and biopsy (FNB) with a new slim linear echoendoscope

Prognostic influence of endoscopic ultrasound-guided fine needle aspiration in IPMN-derived invasive adenocarcinoma

A randomized controlled cross-over trial and cost analysis comparing endoscopic ultrasound fine needle aspiration and fine needle biopsy *

Cellular Dyscohesion in Fine-Needle Aspiration of Breast Carcinoma Prognostic Indicator for Axillary Lymph Node Metastases?

Pancreatico-biliary cytology: a practical approach to diagnosis. Corina Cotoi

A Comparison Of Fine-Needle Aspiration Versus Non- Aspiration Cytology Of Thyroid Nodules

IMPACT OF LOSS OF BILLING FOR MULTIPLE UNITS OF ON CYTOLOGY PRACTICE

An Approach to Pancreatic Cysts. Introduction

The role of the cytologist in breast cancer screening

Original article. Introduction!

HANDOUT. Bile Duct Brushing Cytology: A Morphologic and Molecular Approach

Case report Solid pseudopapillary tumor: a rare neoplasm of the pancreas

CAP Laboratory Improvement Programs

Differentiation of Tumors with Specific Red Cell Adherence (SRCA) test

Safety and utility of endoscopic ultrasound-guided fine-needle aspiration of focal splenic lesions: a retrospective analysis

Endoscopic Ultrasonography Clinical Impact. Giancarlo Caletti. Gastroenterologia Università di Bologna. Caletti

An audit of liquid-based cervical cytology screening samples (ThinPrep and SurePath) reported as glandular neoplasia

Can LBC Completely Replace Conventional Pap Smear in Developing Countries

DOI: /reed /2017 Link: PubMed (Epub ahead of print)

Comparison of Ultrasound-Guided Core Needle Biopsy and Endoscopic Ultrasound-Guided Fine-Needle Aspiration for Solid Pancreatic Lesions

Case 1. Case 1: EUS Report 5/1/2017. Interesting Cases of Pancreatic Masses

Cytology Specimen Management, Triage and Standardized Reporting of Fine Needle Aspiration Biopsies of the Pancreas

Tomonari, Akiko; Katanuma, Akio; Ma Author(s)

EUS Elastography: Advances in Diagnostic EUS of the Pancreas

Chronic pancreatitis mimicking intraductal papillary mucinous neoplasm of the pancreas; Report of tow cases

ACCURACY OF IMMUNOHISTOCHEMISTRY IN EVALUATION

Biliary cytolgy and pancreatic endoscopic ultrasound-guided FNA. Leena Krogerus Helsinki, FINLAND

Dr. Issraa Ali Hussein

Providence Medford Medical Center Pathology Department

Prospective Assessment of the Performance of a New Fine Needle Biopsy Device for EUS-Guided Sampling of Solid Lesions

Study of Fine Needle Aspiration Cytology of Breast Lump: Correlation of Cytologically Malignant Cases with Their Histological Findings

Clinical Study Bedside Endoscopic Ultrasound in Critically Ill patients

A Study of Thyroid Swellings and Correlation between FNAC and Histopathology Results

EUS FNA NEUROENDOCRINE TUMORS. A. Ginès Endocopy Unit Hospital Cínic. Barcelona (Spain)

Immunohistochemistry on Fluid Specimens: Technical Considerations

CURRICULUM VITAE

A Single-Center Experience of Endoscopic Ultrasonography for Enlarged Pancreas on Computed Tomography

Fine Needle Aspiration Cytology of Gastric Glomus Tumor

EUS guided liver biopsy

Atypical Pancreatic Endoscopic Ultrasound-Guided Fine Needle Aspiration Cytology: A Study of Interobserver Agreement

Pancreatic Cystic Neoplasms: Guidelines and beyond

High-frequency miniprobe endoscopic ultrasonography for evaluation of indeterminate esophageal strictures

Cytology of gastrointestinal (GI) samples has a high

Endoscopic Ultrasonography Assessment for Ampullary and Bile Duct Malignancy

Patient History. A 58 year old man presents with a 16 mm cyst in the pancreatic tail. The cyst is unilocular with a thick wall and no mural nodule.

Comparison of Thyroid Fine-Needle Aspiration and Core Needle Biopsy

Presentation material is for education purposes only. All rights reserved URMC Radiology Page 1 of 98

DOI: /jemds/2014/1921 ORIGINAL ARTICLE

The comparative diagnostic accuracy of conventional and liquid-based cytology in a colposcopic setting

Transcription:

Diagnostic Efficacy of Cell Block Immunohistochemistry, Smear Cytology, and Liquid-Based Cytology in Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Lesions: A Single-Institution Experience Shan-yu Qin 1, You Zhou 2 *, Ping Li 3, Hai-xing Jiang 1 * 1 Department of Gastroenterology, the First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, PR China, 2 Minerva Foundation Institute for Medical Research, Helsinki, Finland, 3 Department of Pathology, the First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, PR China Abstract Background: The diagnostic efficiency of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) cytology varies widely depending on the treatment method of the specimens. The present study aimed to evaluate the diagnostic efficacy of cell block (CB) immunohistochemistry, smear cytology (SC), and liquid-based cytology (LBC) in patients with pancreatic lesions without consulting an on-site cytopathologist. Methods: This study prospectively enrolled 72 patients with pancreatic lesions. The EUS-FNA specimens were examined by SC, LBC, and CB immunohistochemistry. The diagnostic efficacy of the 3 methods was then compared. Patients final diagnosis was confirmed by surgical resection specimens, diagnostic imaging, and clinical follow-up. Results: Our results included 60 malignant and 12 benign pancreatic lesions. The diagnostic sensitivity (90%), negative predictive value (66.7%), and accuracy (91.7%) of CB immunohistochemistry were significantly higher than those of SC (70.0%, 30.0%, and 75.0%, respectively) and LBC (73.3%, 31.6%, and 77.8%, respectively) (all P,0.05). The combination of CB and SC, or CB and LBC, did not significantly increase the efficacy compared to CB immunohistochemistry alone. Conclusion: Our findings suggest that in the absence of an on-site cytopathologist, CB immunohistochemistry on EUS-FNA specimens offers a higher diagnostic efficacy in patients with pancreatic lesions than does SC and LBC. Citation: Qin S-y, Zhou Y, Li P, Jiang H-x (2014) Diagnostic Efficacy of Cell Block Immunohistochemistry, Smear Cytology, and Liquid-Based Cytology in Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Lesions: A Single-Institution Experience. PLoS ONE 9(9): e108762. doi:10.1371/journal.pone. 0108762 Editor: Robert L. Schmidt, University of Utah School of Medicine, United States of America Received June 21, 2014; Accepted September 3, 2014; Published September 26, 2014 Copyright: ß 2014 Qin et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Data Availability: The authors confirm that, for approved reasons, some access restrictions apply to the data underlying the findings. Data are available from the Department of Gastroenterology, the First Affiliated Hospital of Guangxi Medical University, China. Due to the ethical rule of Institutional Ethics Review Board of Guangxi Medical University, China, data could not be publicly available. However, data could be obtained from Shan-Yu Qin (Email: qsy0511@163.com, Tel: + 86-0771-5356725, the First Affiliated Hospital of Guangxi Medical University) after signing the ethical agreement. Funding: This study was supported by research funding from the Science and Technology Project of Guangxi Higher Education (LX2014076). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Competing Interests: The authors have declared that no competing interests exist. * Email: you.zhou@helsinki.fi (YZ); gxjianghx@163.com (HXJ) Introduction Endoscopic ultrasound-guided fine-needle aspiration (EUS- FNA) cytology is widely used in the histological diagnosis of abdominal tumors, especially pancreatic lesions [1,2]. Its diagnostic efficacy varies largely depending on a number of factors, including sample treatment, lesion characteristics, and cytopathologists expertise. Smear cytology (SC), liquid-based cytology (LBC), and cell block (CB) preparation are commonly used techniques for the analysis of specimens collected from EUS-FNA. SC, a traditional and standard method for cytological diagnosis, must be performed by an experienced cytopathologist in order to ensure the results accuracy [3,4]. On the other hand, LBC, a thinlayer slide preparation technology, was developed to overcome the drawbacks of SC such as cell crowding and blood contamination [5]. CB provides more pathological information, when combined with histological examination such as hematoxylin and eosin (H&E) staining and immunostaining of serial sections compared with each method alone. Several studies have reported that CB improves diagnostic efficacy, and the implementation of immunocytochemistry is remarkably useful for the discovery of nonmorphological markers [6,7]. However, very few studies have evaluated and summarized the performance of these 3 methods in the examination of EUS-FNA samples. In the present prospective study, we assessed and compared the diagnostic efficacy of SC, LBC, and CB immunohistochemistry in specimens collected by EUS-FNA from patients with pancreatic lesions. PLOS ONE www.plosone.org 1 September 2014 Volume 9 Issue 9 e108762

Materials and Methods Patients and procedures This study was prospectively conducted at the First Affiliated Hospital of Guangxi Medical University from January 2011 to January 2014. The nature and potential risks of the study were explained to all subjects before their written informed consent was obtained. Patients with coagulopathy according to medical history or laboratory coagulation tests were excluded. Consecutive patients with pancreatic lesions who underwent EUS-FNA performed by an experienced endoscopist (S.Y. Qin, who had 8 years experience with EUS-FNA) were included. Patients medical records were reviewed, and clinical information was extracted. The study was approved by the Institutional Ethics Review Board of Guangxi Medical University and conducted in accordance with the Declaration of Helsinki. EUS-FNA procedures A linear array echoendoscope (Olympus Ltd., Tokyo, Japan) was used for EUS, and 22-gauge aspiration needles (Wilson-Cook Medical, Inc., Winston-Salem, NC, USA) were used for FNA. A transduodenal approach was employed for lesions in the head of the pancreas, whereas a transgastric approach was used for those in the pancreatic body or tail. Fine-needle tissue specimens were obtained under endoscopic ultrasound guidance. The needle was inserted into the lesion to its entire length to avoid contaminants of gastric or duodenal mucosa before aspirating. After the needle was retracted into the catheter, the entire catheter was withdrawn. Predesignated passes were followed for each sample type: specimens from the first pass were used for SC, and those from the second and third passes were used for LBC and CB, respectively. On the basis of our preliminary results, the amount of sample procured from a single pass was usually enough for each method. However, that was not the case in 3 patients, who were subsequently excluded from the final analysis. In total, samples from 72 patients were examined by each technique. Aspirated materials were spread onto the center of a glass slide and fixed by skillful cytotechnicians. Slides were then delivered to the laboratory as soon as the procedure was completed. Specimen preparation For SC, 2 smears were prepared for each aspirate. One was airdried for modified Diff-Quick staining, and the other was fixed in ethanol for Papanicolaou staining. For LBC, aspirates were directly expelled into a single vial containing a liquid-based fixation medium for ThinPrep (Cytyc Corporation, Boxborough, MA, USA) processing. All staining procedures were performed after slides were delivered to the laboratory. The sodium alginate CB method was used to prepare CBs for H&E and periodic acid Schiff Alcian blue staining. Aspirate was obtained via a separate pass in each patient and fixed in 10% buffered neutral formalin. Thin sections (4 mm) were cut from paraffin-embedded cell blocks on the following day and stained with H&E. After specimens were incubated in 10 mmol/l citrate buffer (ph 6.0) at 120uC for 10 min, p53 was detected with a monoclonal antibody (ZSGB- BIO, Beijing, China; 1:100) after incubation for 20 min, whereas Ki67 detection with a monoclonal antibody (Maxim, Fuzhou, China; 1:100) was performed for 30 minutes at room temperature. The slides were stained in an automated immunostainer using a Dako Cytomation EnVision-HRP Detection Kit (Dako, Glostrup, Denmark). In the present study, H&E staining and immunostaining were performed for all specimens used for the CB method. Table 1. Results of SC, LBC, and CB tests in benign and malignant pancreatic lesions. Final diagnosis n SC LBC CB + ± 2 + ± 2 + ± 2 + 60 42 0 18 44 0 16 54 6 0 2 12 0 0 12 0 0 12 0 0 12 SC: smear cytology; LBC: liquid-based cytology; CB: cell block histology; +: malignant; 6: indeterminate; 2: benign. doi:10.1371/journal.pone.0108762.t001 PLOS ONE www.plosone.org 2 September 2014 Volume 9 Issue 9 e108762

Table 2. Results of SC, LBC, and CB tests in pancreatic lesions of various types. Lesion types Final diagnosis SC LBC CB Adenocarcinoma 54 41 42 48 SPTP 2 0 0 2 PETs 4 1 2 4 Pancreatic Tuberculosis 10 10 10 10 Chronic pancreatitis 2 2 2 2 Total 72 54 56 66 SC: smear cytology; LBC: liquid-based cytology; CB: cell block histology; PETs: pancreatic neuroendocrine tumors; SPTP: solid pseudopapillary tumor of the pancreas. doi:10.1371/journal.pone.0108762.t002 Definitions An experienced cytopathologist blinded to the diagnostic method used for each specimen assessed the slides. Patients final diagnosis was decided according to diagnostic imaging findings throughout the follow-up period and cytohistological analysis after surgical resections. The mean follow-up time was 12 months (range, 3 16 months). Cytological results from all methods were reported as follows: (1) definite malignancy, (2) suspicion of malignancy, (3) benign cytology, (4) inadequate for diagnosis. Patients were stratified to the malignancy group when their results were either (1) definite malignancy or (2) suspicion of malignancy [8]. Statistical analysis Categorical data were analyzed by the chi-square test and Fisher s exact test as appropriate. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and accuracy were calculated in a 262 contingency table. A P value of,0.05 was considered statistically significant. Data were analyzed using the SPSS version 18.0 for Windows (SPSS, Inc., Chicago, IL, USA). Results Patient characteristics The present study included 72 patients (58 men and 14 women). The mean age of all patients was 54.6 years (range, 24 70 years). The lesion sizes ranged from 0.860.9 cm to 9.669.8 cm. Fifty lesions were located in the head of the pancreas, whereas 22 were in either the body or tail of the pancreas. Three needle passes were made in each lesion on average. Fifty-one patients were diagnosed by cytohistological analysis of the surgical resected samples, whereas diagnoses were based on imaging and serology test results during the follow-up period in the remaining 21 patients. Sixty patients were diagnosed with a malignant tumor, including 54 pancreatic adenocarcinomas, 4 pancreatic neuroendocrine tumors (PET), and 2 solid pseudopapillary tumors of pancreas (SPTP). Benign pancreatic lesions were determined in 12 patients, including 2 cases of pancreatic tuberculosis and 10 cases of chronic pancreatitis. Diagnostic rates in pancreatic lesions CB successfully detected 54 cases of malignant pancreatic lesions, which was higher than the detection rate of SC and LBC. However, all 3 methods were able to correctly determine 12 cases of benign lesions (Table 1). When the lesions were categorized into various types, CB immunohistochemistry successfully detected 48 of 54 pancreatic adenocarcinomas, which was slightly higher than the detection rates of SC and LBC. Moreover, while CB accurately determined all the positive cases of SPTP and PET, SC and LBC failed to detect SPTP and performed inadequately on PET, detecting only 2 of 4 cases. However, SC and LBC were able to detect 3 pancreatic adenocarcinoma cases, which were not detectable by CB. The detection rates of pancreatic tuberculosis and chronic pancreatitis were similar among these 3 methods (Table 2). Diagnostic efficacy in pancreatic lesions The sensitivity (90%), NPV (66.7%) and accuracy (91.7%) of CB immunohistochemistry were significantly higher than those of SC (70.0%, 31.6%, and 75.0%, respectively) and LBC (73.3%, 30.0%, and 77.8%, respectively) (P,0.05). The specificity and PPV were comparable among the 3 methods (Table 3). Diagnostic efficacy of different method combinations Furthermore, we compared the diagnostic efficacy of CB performed in combination with SC or CB with LBC to CB alone. However, no significant differences in sensitivity or accuracy were observed between the method combinations and CB alone (Table 4). Table 3. Diagnostic efficacy of SC, LBC, and CB methods in pancreatic lesions. SC LBC CB Sensitivity, % (n) 70.0% (56.8% 81.2%) 73.3% (60.3% 83.9%) 90.0% (79.5% 96.2%)* Specificity, % (n) 100% (73.5% 100%) 100% (73.5% 100%) 100% (73.5% 100%) PPV, % (n) 100% (91.6% 100%) 100% (92% 100%) 100% (93.4% 100%) NPV, % (n) 30.0% (22.7% 59.4%) 31.6% (24.5% 62.8%) 66.7% (41.0% 86.7%)* SC: smear cytology; LBC: liquid-based cytology; CB: cell block histology; PPV: positive predictive value; NPV: negative predictive value. *P,0.05 CB compared to SC and LBC. doi:10.1371/journal.pone.0108762.t003 PLOS ONE www.plosone.org 3 September 2014 Volume 9 Issue 9 e108762

Table 4. Comparison of diagnostic efficacy among SC, LBC, and CB methods. CB SC+CB LBC+CB Sensitivity, % (n) 90.0% (79.5% 96.2%)* 91.7% (81.6% 97.2%) 93.3% (83.8% 98.2%) Specificity, % (n) 100% (73.5% 100%) 100% (73.5% 100%) 100% (73.5% 100%) PPV, % (n) 100% (93.4% 100%) 100% (93.5% 100%) 100% (93.6% 100%) NPV, % (n) 66.7% (41.0% 86.7%)* 70.6% (44% 89.7%) 75.0% (47.6% 92.7%) SC: smear cytology; LBC: liquid-based cytology; CB: cell block histology; PPV: positive predictive value; NPV: negative predictive value. doi:10.1371/journal.pone.0108762.t004 Complications No serious complications were observed in the present study. Discussion EUS-FNA has been increasingly used for cytological and/or histological assessment of pancreatic lesions as a safe and costefficient method [9,10,11]. In the present study, EUS-FNA was performed in patients with pancreatic lesions using 22-gauge aspiration needles. The specimens were analyzed by SC, LBC, and CB immunohistochemistry. Our findings demonstrated that CB immunohistochemistry provided more reliable and accurate results than SC and LBC did in the diagnosis of pancreatic lesions, suggesting that CB might be a superior method for examining pancreatic samples. SC is a well-established method for cytological diagnosis of tissue samples obtained by EUS-FNA. A number of studies have reported that the sensitivity, specificity, and accuracy of SC for the detection of solid pancreatic masses were 85 90%, 95 100%, and 85 95%, respectively [12,13,14,15]. Despite its decent performance, SC has several limitations. For example, ethanol fixation of cells may remove Papanicolaou staining. In addition, Giemsa and Diff-Quick staining may cause the cells to swell and degenerate. Moreover, specimens for SC are easily contaminated with materials from the gastrointestinal tract, which would undermine diagnostic accuracy. Furthermore, SC in many cases is inadequate owing to sampling error. Such an issue could be easily overcome by applying the rapid on-site cytology evaluation (ROSE) technique. Iglesias-Garcia et al [16] have found that the presence of an on-site cytopathologist significantly decreases the number of inadequate samples and improves diagnostic sensitivity and overall accuracy. However, in many developing countries, the presence of an on-site cytopathologist for each patient is indeed difficult owing to financial constraints. In the present study, although we did not employ an on-site cytopathologist, the diagnostic accuracy and reliability of SC for the detection of pancreatic lesions were similar to those previously reported [17,18]. We found that SC successfully detected all the benign pancreatic lesions in spite of the small sample size. Thus, future studies with a large number of subjects are warranted to confirm our findings. LBC has overcome the drawbacks of SC, such as cell crowding and blood contamination, by using a single layer of cells [19]. The technique is widely employed for the diagnosis of uterine cervical cancer, bile duct cancer, and gall-bladder cancer with high accuracy [20,21]. Some studies have compared the diagnostic performance between LBC and SC for a variety of diseases. However, their results were controversial. Son et al [22] found that LBC could reveal more cellularity with a cleaner background and better cytomorphologic features, and that the diagnostic sensitivity of LBC was remarkably higher than that of SC. In contrast, Sykes et al [23] reported similar sensitivity by LBC and SC for the detection of cervical intraepithelial neoplasia 2/3. To date, few studies have compared the diagnostic efficacy between LBC and SC performed on EUS-FNA specimens from patients with pancreatic lesions. LeBlanc et al [24] reported that LBC was inferior to SC for the detection of pancreatic malignancy in a study that employed an on-site cytopathologist during the EUS-FNA procedure. In addition, a prospective study found that LBC was less accurate than SC after EUS-FNA in patients with pancreatic malignancy [8]. We found that the diagnostic efficacy of LBC was relatively higher than that of SC. However, the difference was not statistically significant. The rates of successfully detecting malignant pancreatic lesions were similar between these 2 methods. Therefore, when cost and technical details are considered, it is hard to conclude that LBC is a better alternative to SC. CB has been recognized as a powerful technique for evaluating tissue architecture and determining its histological features. Moreover, immunostaining of serial sections is commonly used for a definitive cytohistological diagnosis [25,26]. Compared to SC and LBC, CB immunohistochemistry was much more reliable owing to the gold standard of histological staining regardless of Table 5. Comparison between CB and SC methods for pancreatic lesion diagnosis via endoscopic ultrasound-guided fine-needle aspiration. n CB n SC Sensitivity Specificity PPV NPV Sensitivity Specificity PPV NPV Noda et al 85 92.0% 100% 100% 88.9% 85 60% 62.5% 93.8% 60.6% Ardengh et al 178 85.2% 93.1% 98.4% 55.1% 178 61% 100% 100% 36% Haba et al 956 74.9% 78.6% 99.8% 38.2% 983 88.0% 95.2% 100% 54.5% Kopelman et al 85 73.0% 94.0% 96.0% 66.0% 99 63.0% 100% 100% 63.0% SC: smear cytology; CB: cell block histology; PPV: positive predictive value; NPV: negative predictive value. doi:10.1371/journal.pone.0108762.t005 PLOS ONE www.plosone.org 4 September 2014 Volume 9 Issue 9 e108762

lesion location or approaching routes [27,28]. A prospective study reported that the efficacy of CB immunohistochemistry was significantly higher than that of SC for the detection of malignancies and benign lesions [18]. Ardengh et al [29] found that CB immunohistochemistry provided a higher sensitivity and accuracy than SC did in detecting pancreatic tumors from EUS- FNA specimens of 611 patients. In addition, Sai et al [30] reported that the sensitivity, specificity, PPV, and NPV of CB were 92%, 100%, 100%, and 97%, respectively for discriminating benign and malignant branch-duct type neoplasms. Raddaoui et al [28] showed that CB had a 74% sensitivity, 100% specificity, 100% PPV, and 76.9% NPV for the detection of pancreatic lesions. In the present study, the sensitivity and specificity of CB immunohistochemistry were similar to those reported by Noda et al [18], whereas our sensitivity was higher than the values published by Ardengh et al [29], Haba et al [31], and Kopelman et al [27] (Table 5). Such differences might be the result of heterogeneous sample sizes and types, such as solid versus cystic pancreatic lesions. Moreover, we found that CB immunohistochemistry had a significantly higher efficacy than that of SC, which was in agreement with the findings by Noda et al [18], Ardengh et al [29], Haba et al [31], and Kopelman et al [27]. Additionally, CB was able to detect almost all malignant pancreatic lesions in this study, especially SPTP and PETs, which was significant to treatment guidance. Unlike the report by Noda et al [18], H&E staining and immunostaining were performed on all specimens used for the CB method in this study. We found that both staining procedures exerted similar diagnostic performance. Immunostaining did not show any significant contribution to the CB diagnosis over and above H&E histology. The combination of CB and SC or LBC did not significantly increase the diagnostic efficacy compared to CB alone, indicating the relatively accurate detection rate of CB compared with SC or LBC alone. In contrast, 2 cases of pancreatic adenocarcinoma were detected by LBC and 1 by SC while CB failed, suggesting that LBC and SC might be superior in some specific cases. References 1. Agarwal B, Krishna NB, Labundy JL, Safdar R, Akduman EI (2008) EUS and/ or EUS-guided FNA in patients with CT and/or magnetic resonance imaging findings of enlarged pancreatic head or dilated pancreatic duct with or without a dilated common bile duct. Gastrointest Endosc 68: 237 242; quiz 334, 335. 2. Volmar KE, Vollmer RT, Jowell PS, Nelson RC, Xie HB (2005) Pancreatic FNA in 1000 cases: a comparison of imaging modalities. Gastrointest Endosc 61: 854 861. 3. Klapman JB, Logrono R, Dye CE, Waxman I (2003) Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration. Am J Gastroenterol 98: 1289 1294. 4. Layfield LJ, Bentz JS, Gopez EV (2001) Immediate on-site interpretation of fineneedle aspiration smears: a cost and compensation analysis. Cancer 93: 319 322. 5. Linder J (1998) Recent advances in thin-layer cytology. Diagn Cytopathol 18: 24 32. 6. Mansy SS, Abbas MA, Yehia HA, Abdelrazik SM, Ghanem LY, et al. (2006) Value of the innovated technique agarose cell block in improving the sensitivity of urine cytology in cases of bladder carcinoma. Ultrastruct Pathol 30: 379 385. 7. Nathan NA, Narayan E, Smith MM, Horn MJ (2000) Cell block cytology. Improved preparation and its efficacy in diagnostic cytology. Am J Clin Pathol 114: 599 606. 8. Lee JK, Choi ER, Jang TH, Chung YH, Jang KT, et al. (2011) A prospective comparison of liquid-based cytology and traditional smear cytology in pancreatic endoscopic ultrasound-guided fine needle aspiration. Acta Cytol 55: 401 407. 9. Iwashita T, Nakai Y, Samarasena JB, Park do H, Zhang Z, et al. (2013) High single-pass diagnostic yield of a new 25-gauge core biopsy needle for EUSguided FNA biopsy in solid pancreatic lesions. Gastrointest Endosc 77: 909 915. 10. Lee JK, Lee KT, Choi ER, Jang TH, Jang KT, et al. (2013) A prospective, randomized trial comparing 25-gauge and 22-gauge needles for endoscopic ultrasound-guided fine needle aspiration of pancreatic masses. Scand J Gastroenterol 48: 752 757. 11. Woolf KM, Liang H, Sletten ZJ, Russell DK, Bonfiglio TA, et al. (2013) Falsenegative rate of endoscopic ultrasound-guided fine-needle aspiration for Furthermore, CB typically has a longer specimen turn-around time owing to complicated sample processing and immunostaining procedures. For CB, the case results would not be available until at least the following day because of overnight tissue processing. This major drawback of CB remarkably increases the cost compared to SC and LBC methods [32]. Furthermore, several issues are commonly observed with cell immunostaining, such as cell loss, disruption of cells and leakage of antigen, and high background staining owing to blood and necrotic materials. These limitations of CB should be considered cautiously prior to its implementation. Therefore, when selecting an appropriate diagnostic method, physicians should take not only its efficacy but also financial and logistic costs to accommodate each patient s situation into account. Our study has several limitations. First, pre-designated passes were conducted for each sample type, which might present a lack of standardization and cause sampling errors. In addition, selection bias might be inevitable and thus negatively affect the robustness of our results. Therefore, it should be interpreted with caution. Second, not all patients lesions were confirmed by histological examination of the resected specimens. Third, the sample size of the present study was relatively small. Finally, no on-site cytopathologist was employed for SC screening. Thus, the impact of ROSE on the performance of SC and CB was not evaluated. Larger sample size studies in combination with ROSE are warranted to assess the diagnostic accuracy and reliability of CB, SC, and LBC tests. In conclusion, our results suggest that CB immunohistochemistry after EUS-FNA might offer a higher diagnostic efficacy than SC without ROSE and LBC in patients with pancreatic lesions. Author Contributions Conceived and designed the experiments: SYQ HXJ. Performed the experiments: SYQ PL. Analyzed the data: YZ. Contributed reagents/ materials/analysis tools: PL. Contributed to the writing of the manuscript: SYQ YZ. pancreatic solid and cystic lesions with matched surgical resections as the gold standard: One Institution s Experience. Cancer Cytopathol. 12. Ardengh JC, Lopes CV, de Lima LF, de Oliveira JR, Venco F, et al. (2007) Diagnosis of pancreatic tumors by endoscopic ultrasound-guided fine-needle aspiration. World J Gastroenterol 13: 3112 3116. 13. Eloubeidi MA, Tamhane A, Jhala N, Chhieng D, Jhala D, et al. (2006) Agreement between rapid onsite and final cytologic interpretations of EUSguided FNA specimens: implications for the endosonographer and patient management. Am J Gastroenterol 101: 2841 2847. 14. Mitsuhashi T, Ghafari S, Chang CY, Gu M (2006) Endoscopic ultrasoundguided fine needle aspiration of the pancreas: cytomorphological evaluation with emphasis on adequacy assessment, diagnostic criteria and contamination from the gastrointestinal tract. Cytopathology 17: 34 41. 15. Varadarajulu S, Tamhane A, Eloubeidi MA (2005) Yield of EUS-guided FNA of pancreatic masses in the presence or the absence of chronic pancreatitis. Gastrointest Endosc 62: 728 736; quiz 751, 753. 16. Iglesias-Garcia J, Dominguez-Munoz JE, Abdulkader I, Larino-Noia J, Eugenyeva E, et al. (2011) Influence of on-site cytopathology evaluation on the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid pancreatic masses. Am J Gastroenterol 106: 1705 1710. 17. Collins BT, Murad FM, Wang JF, Bernadt CT (2013) Rapid on-site evaluation for endoscopic ultrasound-guided fine-needle biopsy of the pancreas decreases the incidence of repeat biopsy procedures. Cancer Cytopathol 121: 518 524. 18. Noda Y, Fujita N, Kobayashi G, Itoh K, Horaguchi J, et al. (2010) Diagnostic efficacy of the cell block method in comparison with smear cytology of tissue samples obtained by endoscopic ultrasound-guided fine-needle aspiration. J Gastroenterol 45: 868 875. 19. Hutchinson ML, Zahniser DJ, Sherman ME, Herrero R, Alfaro M, et al. (1999) Utility of liquid-based cytology for cervical carcinoma screening: results of a population-based study conducted in a region of Costa Rica with a high incidence of cervical carcinoma. Cancer 87: 48 55. 20. Bernstein SJ, Sanchez-Ramos L, Ndubisi B (2001) Liquid-based cervical cytologic smear study and conventional Papanicolaou smears: a metaanalysis PLOS ONE www.plosone.org 5 September 2014 Volume 9 Issue 9 e108762

of prospective studies comparing cytologic diagnosis and sample adequacy. Am J Obstet Gynecol 185: 308 317. 21. Meara RS, Jhala D, Eloubeidi MA, Eltoum I, Chhieng DC, et al. (2006) Endoscopic ultrasound-guided FNA biopsy of bile duct and gallbladder: analysis of 53 cases. Cytopathology 17: 42 49. 22. Son SM, Koo JH, Choi SY, Lee HC, Lee YM, et al. (2012) Evaluation of Urine Cytology in Urothelial Carcinoma Patients: A Comparison of CellprepPlus(R) Liquid-Based Cytology and Conventional Smear. Korean J Pathol 46: 68 74. 23. Sykes PH, Harker DY, Miller A, Whitehead M, Neal H, et al. (2008) A randomised comparison of SurePath liquid-based cytology and conventional smear cytology in a colposcopy clinic setting. BJOG 115: 1375 1381. 24. LeBlanc JK, Emerson RE, Dewitt J, Symms M, Cramer HM, et al. (2010) A prospective study comparing rapid assessment of smears and ThinPrep for endoscopic ultrasound-guided fine-needle aspirates. Endoscopy 42: 389 394. 25. Chhieng DC, Benson E, Eltoum I, Eloubeidi MA, Jhala N, et al. (2003) MUC1 and MUC2 expression in pancreatic ductal carcinoma obtained by fine-needle aspiration. Cancer 99: 365 371. 26. Hosoda W, Takagi T, Mizuno N, Shimizu Y, Sano T, et al. (2010) Diagnostic approach to pancreatic tumors with the specimens of endoscopic ultrasoundguided fine needle aspiration. Pathol Int 60: 358 364. 27. Kopelman Y, Marmor S, Ashkenazi I, Fireman Z (2011) Value of EUS-FNA cytological preparations compared with cell block sections in the diagnosis of pancreatic solid tumours. Cytopathology 22: 174 178. 28. Raddaoui E (2011) Clinical utility and diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration of pancreatic lesions: Saudi Arabian experience. Acta Cytol 55: 26 29. 29. Ardengh JC, Lopes CV, de Lima LF, Venco F, Santo GC, et al. (2008) Cell block technique and cytological smears for the differential diagnosis of pancreatic neoplasms after endosonography-guided fine-needle aspiration. Acta Gastroenterol Latinoam 38: 246 251. 30. Sai JK, Nobukawa B, Matsumura Y, Watanabe S (2013) Pancreatic duct lavage cytology with the cell block method for discriminating benign and malignant branch-duct type intraductal papillary mucinous neoplasms. Gastrointest Endosc 77: 726 735. 31. Haba S, Yamao K, Bhatia V, Mizuno N, Hara K, et al. (2013) Diagnostic ability and factors affecting accuracy of endoscopic ultrasound-guided fine needle aspiration for pancreatic solid lesions: Japanese large single center experience. J Gastroenterol 48: 973 981. 32. Liu K, Dodge R, Glasgow BJ, Layfield LJ (1998) Fine-needle aspiration: comparison of smear, cytospin, and cell block preparations in diagnostic and cost effectiveness. Diagn Cytopathol 19: 70 74. PLOS ONE www.plosone.org 6 September 2014 Volume 9 Issue 9 e108762