by INTRA-LOCK The REAL Mini Implant IMMEDIATE LOAD STABILIZE DENTURES SIMPLIFIED PROCEDURE PROVISIONAL PROSTHETICS DIRECT PLACEMENT
ENGINEERED EVOLUTION. Intra-Lock has elevated the engineering and delivery system of the Mini Dental Implant. Self-Limiting Depth Design (Patent Pending) Polished Collar Profiled for Strength and Stability Optimum Thread Pitch and Surface Finish Mini Drive-Lock Surgical Placement System Ease of Delivery and Insertion DIRECT DELIVERY PACKAGE INSTRUMENTATION FOR LINEAR PATH OF INSERTION MDL Implants were designed to take advantage of the Drive-Lock System which ensures Contra Angle delivery and placement is fluid, economic in motion and predictable. It allows the MDL implant to be removed from its sterile vial, transferred directly to the surgical site and to initiate the self- tapping action. A Drive-Lock Adapter mates with a surgical ratchet wrench for final seating. This ratchet adapter can be used by hand and also mates with an optional Round Hand Driver to provide greater initial torque and enhanced tactile sensation. All Drive-Lock instruments are designed to promote a linear path of insertion. Maximum Self-Threading Capabilities SHARP APICAL GUIDING POINT OPTIMUM THREAD PITCH PROFILED FOR STABILITY ENGINEERED FOR STRENGTH MDL s sharp apical guiding point initiates the self-tapping process, even in the densest bone. Unlike conventional sized implants, mini implants rely on the viscoelastic nature of bone tissue. They function very much like orthopedic fixation screws. Mini implant surgical protocol does not require an osteotomy site, just a pilot hole through the cortical bone. Therefore, the implant must be able to penetrate the cortical plate, cut its way through the alveolar bone with maximum ease and efficiency, forcibly wedging itself into place. Its thread pitch and wedge profile permits intimate contact between the bone and implant surface ensuring initial stability and encouraging immediate load success. MDL s profile is also configured to provide maximum strength where the highest forces are generated. Sharp Apical Guiding Point Soft Tissue and Prosthetic Interface POLISHED COLLAR ACHIEVES OPTIMUM IMPLANT DEPTH MDL Implants are designed with a polished collar in order to optimize the soft tissue response to the implant surface. All Drive-Lock instrumentation seats over the O-Ball abutment precisely mating with the top of the collar. This ensures that depth of implant placement is accurately attained when the shoulder of the collar is flush with (the height of) the surrounding gingiva. MDL s are provided with O-Rings encased in Metal Housings ready to be processed in a denture. A special abutment that cements over the O-Ball assembly has been designed for temporary fixed bridges. This abutment functions as an impression coping and can be laboratory machined for parallelism.
MDL Implant Denture Stabilization Light, repeated, intermediate, vertical introduction of the 1.2mm externally irrigated Pilot Drill breaches the gingival tissue and periosteum. Drilling depth is approximately one-third the length of the implant with care taken to breach the cortical plate. MDL s are removed from their sterile vial and transferred directly to the surgical site via a Drive-Lock Contra- Angle Attachment that snaps over the O-ball assembly. The use of an electric motor with a torque limiting feature set to 35Ncm is recommended. MDL s sharp apical gliding point initiates the selftapping action; threading and expanding the bone at the same time. In preparation for the final seating, The handpiece will stall when the torque limiting value of 35Ncm is reached.
Drive-Lock Adapter mates with a Surgical Ratchet Wrench for the final seating phase. This Ratchet Adapter can be used by hand and also mates with an optional Round Hand Driver to provide greater initial torque and enhanced tactile sensation. MDL s are provided with O-Rings encased in Metal Housings. Small incremental turns, with a pause between each turn to take advantage of the viscoelastic nature of the bone accomplishes final seating. The correct depth of an MDL implant is achieved when the wrench adapter is flush with the surrounding gingival tissue. They snap over the O-Ball assembly ready to be processed in a denture. A special abutment that cements over the O-Ball assembly has been designed for temporary fixed bridges
MDL Temporary Abutment Protocol 1 Surgical Placement 2 Impression Copings 3 Impression 4 MDL Analogs 5 MDL Abutment Preparation 6 Temporary Fixed Bridges 1. Surgical Placement - MDL Implants are surgically placed in position. 2. Impression Copings - MDL Abutments slide over O-Balls and serve as impression copings. 3. Impression - MDL Abutments are picked up in an impression tray. 4. MDL Analogs - Analogs are placed into the MDL Abutments in the impression. 5. MDL Abutment Preparation - A laboratory milling machine prepares the abutments to achieve parallelism. 6. Temporary Fixed Bridges -The Abutments are cemented over the MDL Implants with resin cement. A metal reinforced bridge (for rigidity) is then cemented on the abutments with temporary cement.
IMPLANTS DRILL MDI Mini Drive-Lock implants, 2.0mm Diameter Length 10mm 13mm 15mm 18mm Ref No. MDL10 MDL13 MDL15 MDL18 Mini Drive-Lock Pilot Twist Drill 1.2mm diameter...mdlpd INSTRUMENTS FOR INSERTION OF IMPLANTS MDLMW MDLCAD MDLRD Mini Drive-Lock Contra Angle Driver Standard Contra Angle...MDLCAD Mini Drive-Lock Ratchet Driver Use as an MDL Hand Driver or with a Surgical Ratchet Wrench...MDLRD Mini Drive-Lock Manual Wrench Connects to Mini Drive-Lock Ratchet Driver...MDLMW SR SURGICAL BOX Surgical Ratchet Wrench With square connection, 4x4mm, autoclavable...sr Mini Drive-Lock Surgical Box Accommodates all MDL surgical instruments for MDL Implant delivery and placement...mdlsk PROSTHETIC COMPONENTS MDLMH Mini Drive-Lock Laboratory Analog Replicates the MDL Implant and abutment...mdlla Mini Drive-Lock Metal Housings with O-Rings O-Rings encapsulated in metal housings for ease of placement and replacement...mdlmh MDLLA MDLOR MDL O-Ring Replacements Quantity of 10...MDLOR MDLSA Mini Drive-Lock Cementable Abutment Cements over O-Ball assembly for temporary fixed bridges...mdlsa Intra-Lock International, Inc. 1200 North Federal Highway, Suite 200 Boca Raton, Florida 33432 www.intra-lock.com info@intra-lock.com CE 0499 Copyright 2003, Intra-Lock System International S4EN-09-01