Available online at ScienceDirect. Physics Procedia 70 (2015 )

Similar documents
ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

HIGH FREQUENCY QUANTITATIVE ULTRASOUND IMAGING OF SOLID TUMORS IN MICE

Descriptions of NDT Projects Fall 2004 October 31, 2004

Linear Ultrasonic Wave Propagation in Biological Tissues

TG-128: Quality Assurance for Prostate Brachytherapy Ultrasound

Flaw Assessment Using Shear wave Phased array Ultrasonic Transducer

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Techniques and Evaluation From a Cross- Platform Imaging Comparison of Quantitative Ultrasound Parameters in an In Vivo Rodent Fibroadenoma Model

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

A new method of sonograph lateral resolution measurement using PSF analysis of received signal

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS

On the feasibility of speckle reduction in echocardiography using strain compounding

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS

Physical Principles of Ultrasound

Ultrasonic Testing Level I:

INSPECTION THROUGH AN OVERLAY REPAIR WITH A SMART FLEXIBLE ARRAY PROBE.

8/15/2011. Quantitative Ultrasound Imaging: A Historical Perspective. Motivation. Motivation & Applications. Motivation & Applications

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions.

ScienceDirect. On the ultrasonic atomization of liquids

The latest developments - Automated Breast Volume Scanning. Dr. med. M. Golatta

CHARACTERIZATION OF ANNULAR ARRAY TRANSDUCER

Bone Densitometry at the Point of Care

Pulse-Echo Ultrasound Imaging. Resolution in Ultrasound Imaging. Doppler Ultrasound. Resolution vs Penetration. Medical Imaging (EL582/BE620/GA4426)

Research on a Transmit-Receive Method of Ultrasonic Array for Planar Defects

Diagnostic TRUS Elastography of the Prostate

Ultrasound Physics & Doppler

Obesity and Liver Disease:Evaluation of Fatty Infiltration of the Liver. Using Ultrasonic Attenuation

Skin Characterization with High-Frequency Ultrasound

Basic Ultrasound Physics Board Review Questions

Controlled Cryogenic Ablation Using Ultrasonic Sensing

Underwater Acoustic Measurements in Megahertz Frequency Range.

Introduction. The goal of TRUS QA is to ensure your system can do all of this accurately.

Ultrasound. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Oct 17th, 2016

Medical Review Approaches to the Diagnosis of Liver Fibrosis

1 Fundamentals. Basic Definitions and Physics Principles. Fundamentals

Augmentation of the In Vivo Elastic Properties Measurement System to include Bulk Properties

Application of ultrasonic phased array in acoustic logging

Dr Emma Chung. Safety first - Physical principles for excellent imaging

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis and Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRAINING PHANTOMS

Chapter 6. Hester Gietema Cornelia Schaefer-Prokop Willem Mali Gerard Groenewegen Mathias Prokop. Accepted for publication in Radiology

Ultrasonography of the Neck as an Adjunct to FNA. Nicole Massoll M.D.

Quantitative Ultrasound Comparison of MAT and 4T1 Mammary Tumors in Mice and Rats Across Multiple Imaging Systems

Dispersion Compensating Fibers with Improved Splicing Performance

DIGITAL IMAGE PROCESSING IN ULTRASOUND IMAGES

ADVANCED PHASED ARRAY TECHNOLOGIES

Current Ultrasound Quality Control Recommendations and Techniques

Monitoring of Tissue Ablation Using Time Series of Ultrasound RF Data

TTU Phased Array: Quality and Productivity

The Evolution and Benefits of Phased Array Technology for the Every Day Inspector

Semi-automatic Thyroid Area Measurement Based on Ultrasound Image

STUDY OF PHASED ARRAY TECHNIQUES FOR CONCRETE INSPECTION

ACR MRI Accreditation Program. ACR MRI Accreditation Program Update. Educational Objectives. ACR accreditation. History. New Modular Program

Ultrasonic Testing of Rails Using Phased Array

DOW-RAD, DOW DIAGNOSTIC COMPLEX, DUHS TRAINING PROGRAM HANDBOOK 2013

Basic Physics of Ultrasound and Knobology

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

Feng Xiujuan National Institute of Metrology (NIM),China

Virtually-tracked US-guided Radiofrequency Ablation(RFA) of Benign Thyroid Nodules: Preliminary Results

Imaging Decisions Start Here SM

Can Color Doppler Sonography Aid in the Prediction of Malignancy of Thyroid Nodules?

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques

Compact Gamma Camera for Detection of Prostate Cancer

Introduction to Biomedical Imaging

CONTENTS. Test Number cpd Tanya Reynolds (Nat. Dip. Diag. Rad., B. Tech. Diag. Rad., B. Tech. Ultrasound)

PROPOSTA DI UN NUOVO ALGORIMO PER LA DIAGNOSI ECOGRAFICA DELLE MALATTIE CRONICHE DEL FEGATO

Derivation of Sonograph Quality Parameters by the Use of Point Spread Function Analysis

ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING

A quality control program for MR-guided focused ultrasound ablation therapy

Laly Jose, Sara Ammu Chacko, Simi.

Table 1: Samples used in experimental program. Block ID/thickness [ mm ]

Certificate in Clinician Performed Ultrasound (CCPU) Syllabus. Vascular Access (venous (peripheral and central) and arterial)

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound

ULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS

w. D. Jolly, F. A. Bruton, and C. Fedor

Ultrasound in Medicine

API. Defined Procedure. for. Ultrasonic Thickness Measurement API-UT-21

Evaluation of thyroid nodules: prediction and selection of malignant nodules for FNA (cytology)

Ultrasound: Past and Present. Lecturer: Dr. John M Hudson, PhD

Sensors & Transducers 2015 by IFSA Publishing, S. L.

Improved ultrasound-based navigation for robotic drilling at the lateral skull base

764 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 23, NO. 6, JUNE 2004

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

Routine Quality Assurance Cookbook

of Thyroid Lesions Comet Tail Crystals

Inspection of Polyethylene Fusions and Electrofusions

Contrast-enhanced ultrasound of solitary thyroid nodules - qualitative and quantitative evaluation: initial results

Study of validity of ultrasonographic diagnosis in relation to Fine Needle Aspiration Cytology (FNAC) diagnosis

Ultrasound Guided HIFU Ablation (USgFUS)

Phased Array Ultrasonics and Eddy Current Examination for Graphite Components

Available online at ScienceDirect. Physics Procedia 87 (2016 ) 35 41

Thyroid Pathology: It starts and ends with the gross. Causes of Thyrophobia. Agenda. Diagnostic ambiguity. Treatment/prognosis disconnect

Improved Inspection of Composite Wind Turbine Blades with Accessible Advanced Ultrasonic Phased Array Technology

Ultrasound Measurements and Non-destructive Testing Educational Laboratory

Invasive Coronary Imaging Modalities for Vulnerable Plaque Detection

Ultrasonic Phased Array for the Circumferential Welds Safety Inspection of Urea Reactor

Preamble (disclaimer)

Roaa M.Hussein Professor, Department of Physics, College of Science, Ramadi, Iraq. Abstract:

iu22 Liver Shear Wave ElastPQ

Transcription:

Available online at www.sciencedirect.com ScienceDirect Physics Procedia 70 (2015 ) 1139 1143 2015 International Congress on Ultrasonics, 2015 ICU Metz Attenuation Coefficient Estimation of the Healthy Human Thyroid In Vivo J. Rouyer a*, T. Cueva a, A. Portal b, T. Yamamoto b and R. Lavarello a a Laboratorio de Imágenes Medicas, Pontificia Univ. Católica del Perú, Av. Universitaria 1801 - San Miguel, Lima 32, Lima, Perú b Dep. de Radiología, Clínica Centenario Peruano Japonesa, Av. Paso de Los Andes 675 - Pueblo Libre, Lima 32, Lima, Perú Previous studies have demonstrated that attenuation coefficients can be useful towards characterizing thyroid tissues. In this work, ultrasonic attenuation coefficients were estimated from healthy human thyroids in vivo using a clinical scanner. The selected subjects were five young, healthy volunteers (age: 26 6 years old, gender: three females, two males) with no reported history of thyroid diseases, no palpable thyroid nodules, no smoking habits, and body mass index less than 30 kg/m 2. Echographic examinations were conducted by a trained sonographer using a SonixTouch system (Ultrasonix Medical Corporation, Richmond, BC) equipped with an L14-5 linear transducer array (nominal center frequency of 10 MHz, transducer footprint of 3.8 cm). Radiofrequency data corresponding to the collected echographic images in both transverse and longitudinal views were digitized at a sampling rate of 40 MHz and processed with Matlab codes (MathWorks, Natick, MA) to estimate attenuation coefficients using the spectral log difference method. The estimation was performed using an analysis bandwidth spanning from 4.0 to 9.0 MHz. The average value of the estimated ultrasonic attenuation coefficients was equal to 1.34 ± 0.15 db/(cm.mhz). The standard deviation of the estimated average attenuation coefficient across different volunteers suggests a non-negligible inter-subject variability in the ultrasonic attenuation coefficient of the human thyroid. 2015 2015 The The Authors. Authors. Published Published by Elsevier by Elsevier B.V. B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Peer-review under responsibility of the Scientific Committee of 2015 ICU Metz. Peer-review under responsibility of the Scientific Committee of ICU 2015 Keywords: Attenuation coefficient; thyroid; quantitative estimation; in vivo 1. Introduction The thyroid gland is a readily accessible for ultrasound inspection thanks to an easily identifiable location (i.e., below the Adam s apple surrounding the trachea) at a shallow depth (i.e., from 1 to 3 cm). The thyroid cancer is the * E-mail address: jrouyer@pucp.pe 1875-3892 2015 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Peer-review under responsibility of the Scientific Committee of ICU 2015 doi:10.1016/j.phpro.2015.08.244

1140 J. Rouyer et al. / Physics Procedia 70 ( 2015 ) 1139 1143 most rapidly increasing cancer with a rate of 6% in a period ranging from 2006 to 2010 in the United States of America (American Cancer Society 2014). Ultrasonic B-mode imaging is widely used as a medical tool for assessing the malignancy of thyroid nodules but currently no ultrasonic marker allows the reliable distinction between benign and malignant nodules for all nodules (Frates et al. 2006). As a result, fine-needle aspiration remains the gold standard for thyroid cancer assessment (Amrikachi et al. 2001). Therefore, there is a need to develop non-invasive tools that aid in the identification of malignant tissues in this gland. Quantitative ultrasound (QUS) parameters have demonstrated potentially useful diagnostic capabilities for thyroid cancer in studies involving small animal models (Lavarello et al. 2013a; Montero et al. 2014; Zenteno et al. 2013; Lavarello et al. 2013b). The estimation of attenuation coefficient slopes allowed differentiating between benign and malignant tissues. Derived parameters from the backscatter coefficient estimates (i.e., effective scatter diameter and effective acoustic concentration) also exhibited interesting differentiation capabilities which were correlated with histological slices. However, the backscatter coefficient estimation requires knowledge of the attenuation coefficient in order to perform frequency-dependent attenuation compensation (Oelze and O Brien 2002). Therefore, the attenuation coefficient slope is a key parameter in order to perform accurate quantitative tissue characterization. As a first step towards determining the usefulness of spectral-based quantitative ultrasound for thyroid cancer diagnosis, this study deals with the estimation of the attenuation coefficient slope in healthy human thyroids in vivo. Radio-frequency data from five young volunteers were acquired by a trained radiologist using a clinical scanner equipped with a 10 MHz linear array. The spectral log difference method was used for obtaining several estimates of the attenuation coefficient slope. Both intra- and inter-subject variability were calculated and the results were compared to the few studies on attenuation estimation in the thyroid available in the literature. 2. Materials and Methods 2.1. Attenuation estimation technique The spectral log difference technique was employed for the estimation of the attenuation coefficient slope. This technique gives accurate attenuation estimates in regions of interest (ROIs) with homogeneous scatter sizes (Labyed and Bigelow 2011). The estimation is based on a spectral comparison between proximal ( ) and distal ( ) subregions within the ROI. A reference phantom is employed to correct for the diffraction effects and the apparatus transfer function. If the selected region is homogeneous with respect to the scattering sources, then the difference of the logarithm of the spectral ratio in the proximal and distal sub-regions is proportional to the unknown attenuation coefficient, i.e., (1) where and are the average power spectra corresponding to the tissue and the reference phantom, respectively, is the frequency, and are the depth of the proximal and distal sub-rois, is a numerical constant, and is the attenuation function of the reference phantom. The attenuation function of the thyroid was considered linear with frequency within the analysis frequency range of this study, and defined as with the attenuation coefficient slope of the thyroid. The estimates of the attenuation coefficient slope ( ) were obtained using least absolute deviation regression. 2.2. Data acquisition and estimation procedure The experimental protocol was approved by the Ethics Committee of the Pontificia Universidad Católica del Perú. Briefly, the selected subjects were five young, healthy volunteers (age: 26 +/- 6 years old, gender: three females, two males) with no reported personal or family history of thyroid diseases, no palpable thyroid nodules, no

J. Rouyer et al. / Physics Procedia 70 ( 2015 ) 1139 1143 1141 smoking habits, and body mass index less than 30 kg/m 2. Echographic examinations were conducted by a trained sonographer using a SonixTouch system (Ultrasonix Medical Corporation, Richmond, BC) equipped with an L14-5 linear transducer array (nominal center frequency of 10 MHz, transducer footprint of 3.8 cm). Rf-data corresponding to the collected echographic images were digitized at a sampling rate of 40 MHz. Several frames of the thyroid images were acquired in the longitudinal view (i.e. along the trachea) as this orientation enables to inspect a larger part of the gland. The attenuation coefficient slope estimates were obtained using an analysis frequency band ranging from 4 to 9 MHz. The reference phantom consisted in an agar-based matrix with embedded glass beads uniformly arranged with a diameter ranged between 90 and 106 microns and a scatter density of 3.5 scatterers per mm 3. The attenuation coefficient slope and speed of sound in the reference phantom were was 0.68 db/(cm.mhz) and 1540 m/s, respectively. The reference phantom acquisitions were performed using the exact same system settings used for scanning the thyroids. The attenuation coefficient slope estimates were calculated in a rectangular domain. Particular attention was paid to select thyroid tissues with apparent speckle homogeneity. The lateral ROI size was chosen equal to 0.56 cm (i.e., about 20 wavelengths at the center frequency of the analysis band) which corresponded to 48 rf-lines in the image. The ROIs had a 50% overlap ratio in the lateral direction. The axial ROI dimension was set as a variable parameter which depended on the size and morphology of each studied thyroid gland. The axial sub-rois (i.e., proximal and distal) had a fixed dimension equal to 0.35 cm (i.e., about 14 wavelengths at the center frequency of the analysis band) in order for the expression in (1) to be valid (i.e., 0.5, see (Oelze and O Brien 2002)). Four different frames for each one of the five volunteers were used in the estimation process. Fig. 1. B-mode image of the right thyroid lobe of volunteer #1 (longitudinal view). The white square depicts the usable domain of thyroid tissue. This domain was segmented into several ROIs along the lateral direction. 3. Results and Discussion A sample longitudinal B-mode image of a thyroid is shown in Fig. 1. The employed analysis region is depicted by a white square, which was segmented in to several ROIs as indicated in the previous section. Figure 2(a) shows the typical averaged power spectra ( ) of the proximal and distal sub-rois in the case of the thyroid tissue and the reference phantom. Within the selected bandwidth, the frequency content of the distal rf-signals are lower

1142 J. Rouyer et al. / Physics Procedia 70 ( 2015 ) 1139 1143 than the proximal sub-roi and clearly shows the loss of the high frequency content with increasing depth. The left term of (1), which corresponds to the spectral log difference compensated by the attenuation of the reference phantom, is plotted in Fig. 2(b). The coherent component of the backscattered spectra introduces an oscillatory noise in this function. The use of an L1-linear regression was selected in order to reduce the effects of outliers in the attenuation slope estimation process. Table 1. The average estimates ( ) and the standard deviation of the estimates ( ) for all five volunteers in this study. Some relevant parameters employed for the estimation of the attenuation coefficient slopes, including the average number of ROIs per frame (ROI/frame), the total number of ROIs (ROI total), and the average distance between the center of the proximal and distal sub-rois ( ), are also listed. Volunteer # ROI/frame ROI total [cm] [db/(cm.mhz)] [db/(cm.mhz)] 1 6 29 1.18 1.23 0.17 2 8.25 33 0.46 1.40 0.39 3 9.5 46 0.49 1.19 0.34 4 5 20 0.77 1.57 0.46 5 5 20 1.31 1.33 0.11 The estimates of the attenuation coefficient slope of the thyroids are presented in Table 1. This table also includes some relevant parameters which were used in the estimation process. The total number of attenuation coefficient slope estimates per volunteer depended on the size of the usable thyroid area in each image. Overall, the average attenuation coefficient slope considering all five volunteers was 1.34 0.15 db/(cm.mhz). To our knowledge, there is one study in the literature dealing with the attenuation estimation in human thyroids in vivo (Fujii et al. 2003). In this study, the attenuation coefficient slope for normal thyroids was estimated to be 1.50 0.26 db/(cm.mhz). The estimates of attenuation coefficient slope presented in the current study are in close agreement with the values in (Fujii et al. 2003), which were obtained using a modified version of the spectral shift central frequency method (Fujii et al. 2002), and using a wide age range (10 to 76 years old). Therefore, these results suggest attenuation coefficient slope estimation from thyroids in vivo can be reliably performed using spectral-based methods with pulse-echo data. (a) (b) Fig. 2. Example of the calculation for one typical ROI. (a) The averaged power spectra of the thyroid tissue in thick red lines and the reference phantom in thin black lines. Proximal and distal sub-rois curves are plotted in plain and dashed line, respectively. (b) The left term of (1) is plotted with the corresponding L1-linear regression, respectively in plain blue line and in dashed black line.

J. Rouyer et al. / Physics Procedia 70 ( 2015 ) 1139 1143 1143 The mean values for each volunteers are spread between 1.19 and 1.57 db/(cm.mhz), which suggests a nonnegligible inter-subject variability. This variability may be partially due to limitations of the estimation algorithm, but may also be due to variations in the actual attenuation coefficients across subjects even though the volunteers were in a narrow age range. The employed technique was able to estimate the attenuation coefficient slope with a relatively low intra-subject variation (between 8 % and 30 %), which suggests that the attenuation coefficient can be reliably estimated in a clinical context. Acknowledgment This work was supported by CONCYTEC grant 8-2013-FONDECYT. References American Cancer Society, 2014. Cancer Facts & Figures. M. Amrikachi., I. Ramzy, S. Rubenfeld, and T. M. Wheeler, 2001. Accuracy of Fine-Needle Aspiration of Thyroid. Archives of pathology & laboratory medicine 125(4):484 88. M. C. Frates, et al., 2006. Management of Thyroid Nodules Detected at US: Society of Radiologists in Ultrasound Consensus Conference Statement. Ultrasound Quarterly 22(4):231 38. Y. Fujii et al. 2002. A New Method for Attenuation Coefficient Measurement in the Liver. Journal of Ultrasound in Medecine 21:783 88. Y, Fujii N. Taniguchi, N. Itoh, and K. Omoto, 2003. Attenuation Coefficient Measurement in the Thyroid. Journal of Ultrasound in Medicine 22(10):1067 73. Y. Labyed and T. Bigelow, 2011. A Theoretical Comparison of Attenuation Measurement Techniques from Backscattered Ultrasound Echoes. The Journal of the Acoustical Society of America 129(4):2316 24. R. Lavarello, W. B. Ridgway, S. Sarwate and M. L. Oelze, 2013. Imaging of Follicular Variant Papillary Thyroid Carcinoma in a Rodent Model Using Spectral-Based Quantitative Ultrasound Techniques., IEEE 10th International Symposium on Biomedical Imaging (ISBI), 732 35. R. Lavarello, W. B. Ridgway, S. Sarwate, and M. L. Oelze, 2013. Characterization of Thyroid Cancer in Mouse Models Using High-Frequency Quantitative Ultrasound Techniques. Ultrasound in Medicine & Biology 39(12):2333 41. M. L. Montero, O. Zenteno, B. Castaneda, M. L. Oelze, and R. Lavarello, 2014. Evaluation of Classification Strategies Using Quantitative Ultrasound Markers and a Thyroid Cancer Rodent Model. IEEE International Ultrasonics Symposium (IUS), 1916 19. M. L. Oelze and. W. D. O Brien, 2002. Frequency-Dependent Attenuation-Compensation Functions for Ultrasonic Signals Backscattered from Random Media. The Journal of the Acoustical Society of America 111(5):2308. O. Zenteno, W. B. Ridgway, S. Sarwate, M. L. Oelze, and R. Lavarello, 2013. Ultrasonic Attenuation Imaging in a Rodent Thyroid Cancer Model. IEEE International Ultrasonics Symposium (IUS) 88 91.