Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty

Similar documents
Polyethylene wear of mobile-bearing unicompartmental knee replacement at 20 years

Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year

Assessment of radiolucent lines around the Oxford unicompartmental knee replacement

Pre-operative clinical and radiological

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing

Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty Kort, N. P.; van Raay, J. J. A. M.; Thomassen, B. J. W.

With over 40 years clinical experience, the Oxford Partial Knee is the most widely used, 1 clinically proven 2 partial knee system in the world.

The effect of leg alignment on the outcome of unicompartmental knee replacement

Oxford. Partial Knee

Activity Level and Wear in Total Knee Arthroplasty

Mid-Term Results of Oxford Medial Unicompartmental Knee Arthroplasty

The Knee. The Twin Peg Oxford partial knee replacement: The first 100 cases. Stephen H. White a,, Sharon Roberts a, Peter W.

Conversion of unicompartmental knee arthroplasty to total knee arthroplasty : The challenges and need for augments

Evolution. Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee. Key Aspects

TOTAL KNEE ARTHROPLASTY (TKA)

Examination of Porous-Coated Patellar Components and Analysis of the Reasons for Their Retrieval

BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS IN TOTAL KNEE REPLACEMENTS

Does a minimally invasive approach affect positioning of components in unicompartmental knee arthroplasty? Early results with survivorship analysis

Case Report Meniscal Bearing Dislocation of Unicompartmental Knee Arthroplasty with Faint Symptom

Management of Periprosthetic Fracture in Unicompartmental Knee Arthroplasty Patients: A Case Series

Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacement

Estimating Total Knee Arthroplasty Joint Loads from Kinematics

Frontal Plane Kinematics After Mobile- Bearing Total Knee Arthroplasty

The young patient and the medial unicompartmental knee replacement

SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY

Gold standard of a TKA. Conflicting goals? POLYETHYLENE WEAR THE SOLUTION: MOBILE BEARING KNEES. MOBILE BEARING A totally new approach (1977)

Unicompartmental or total knee replacement

A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients

Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system

Revision surgery for failed unicompartmental knee replacement : Technical aspects and clinical outcome

The Survivorship and Clinical Results of Minimally Invasive Unicompartmental Knee Arthroplasty at 10-Year Follow-up

The influence of degeneration of the lateral patellofemoral joint on outcome of medial unicompartmental knee replacement

Implant Overhang after Unicompartmental Knee Arthroplasty: Oxford Prosthesis versus Miller-Galante II Prosthesis

Minimally invasive unicompartmental knee arthroplasty in treatment of osteonecrosis versus osteoarthritis : a matched-pair comparison

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou

The Oxford phase III unicompartmental knee replacement in patients less than 60 years of age Kort, Nanne P.; van Raay, Jos J. A. M.; van Horn, Jim J.

ATTUNE KNEE SYSTEM: SOFCAM CONTACT

Early failure of total hip replacements implanted at distant hospitals to reduce waiting lists

MARATHON Cross-Linked Polyethylene

Three-Dimensional Analysis of Alignment Error in Using Femoral Intramedullary Guides in Unicompartmental Knee Arthroplasty

Poor mid-term results of total hip arthroplasty with use of a Hylamer liner

We studied the migration of 58 cemented Hinek

Simplifying the Most Clinically Proven 1 Partial Knee in the World. Oxford Partial Knee with Microplasty Instrumentation

Rotaglide+ TM. Total Knee System Product overview

39 year old, 260 lb. park ranger. TKA in situ: 4 Years. First reported Metal-backed, non-modular PCA knee. 16% incidence. Modular metalbacked

Complications of Medial Unicompartmental Knee Arthroplasty

Design of a Novel Total Knee Prosthesis Using TRIZ

Stability without compromise. Epsilon Durasul Constrained Insert

Unicompartmental Knee Replacement

Bilateral Total Knee Replacements using Two Different Implant Designs - Preliminary Report

CLINICAL AND OPERATIVE APPROACH FOR TOTAL KNEE REPLACEMENT DR.VINMAIE ORTHOPAEDICS PG 2 ND YEAR

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

EMPOWERING LIFE THROUGH NATURAL MOTION

Fixed or Mobile bearing in Unicompartmental Knee Arthroplasty

UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD

Radiological Decision Aid to determine suitability for medial unicompartmental knee arthroplasty

HIGH FLEXION IN CONTEMPORARY TOTAL KNEE DESIGN: A PRECURSOR OF UHMWPE DAMAGE? A FINITE ELEMENT STUDY

Oxford Phase 3 unicompartmental knee arthroplasty: medium-term results of a minimally invasive surgical procedure

Developing techniques for the dimensional assessment of true clinical wear in retrieved total joint replacements.

W. (2016) : - 98 (8) ISSN X,

Observations on retrieved articular surfaces of total knee prostheses. Department of Orthopaedics, Leiden University Medical Center, The Netherlands

why bicompartmental? A REVOLUTIONARY ALTERNATIVE TO TOTAL KNEE REPLACEMENTS

Triathlon Tritanium Knee System

Medial unicompartmental knee replacement in the under-50s

The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006

Instrumentation Options

A NEW APPROACH TO BEARING SURFACES FOR TOTAL HIP ARTHROPLASTY

Original Article. Introduction. Materials and Methods

The Role of Partial Knee Arthroplasty for Medial OA of the Knee: It s Time has come, Again 34 th Annual Verne T. Inman Lecture.

CLASSIFICATION OF MOBILE BEARING KNEE DESIGN: MOBILITY AND CONSTRAINT

Unicondylar Knee Vs Total Knee Replacement: Is Less Better In the Middle Aged Athlete

BIOTRIBOLOGICAL AND MECHANICAL ANALYSIS OF TOTAL HIP ARTHROPLASTIY FAILURE: How to break the code

1. White SH, Nazarian NA, McEwen Smith AM, Balfour TW. Periampullary adenoma causing pancreatitis. Br Med J 1981; 283:527.

ATTUNE Knee System: Stability in Total Knee Replacement

Does the self-centering mechanism of bipolar hip endoprosthesis really work in vivo?

Bicruciate-Retaining or Medial Pivot Total Knee Prosthesis Pritchett 225 Fig. 3. The MP total knee prosthesis. Fig. 1. An anteroposterior radiograph o

Total hip replacement with a zirconium oxide ceramic femoral head

Mid-Term Results of Oxford Medial Unicompartmental Knee Arthroplasty in Young Asian Patients Less than 60 Years of Age: A Minimum 5-Year Follow-up

National Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement

Simplifying the Most Clinically Proven Partial Knee in the World. Oxford Partial Knee with Microplasty Instrumentation

Advantages of Mobile-bearing Total Knee Arthroplasty

Zimmer Longevity Highly Cross-linked Polyethylene. Clinical Value Dossier - APAC

EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE.

Range of Motion of Standard and High-Flexion Posterior Stabilized Total Knee Prostheses A PROSPECTIVE, RANDOMIZED STUDY

(c) B. Ravi, IIT Bombay 1

Gender Solutions Patello-Femoral Joint System

Kinematic vs. mechanical alignment: What is the difference?

Pseudo tumor a cystic or solid mass (MRI or ultrasound) 1% of MOM pts develop pseudo tumors by 5 years 17 pts, all female, Pandit et al (JBJS, 2008)

Stefan Rahm MD University Hospital Balgrist

Functional Outcome of Uni-Knee Arthroplasty in Asians with six-year Follow-up

The UniSpacer : correcting varus malalignment in medial gonarthrosis

Clinical Results of Lateral Unicompartmental Knee Arthroplasty: Minimum 2-Year Follow-up

We carried out weight-bearing video radiological

A Kinematic Assessment of Knee Prosthesis from Fluoroscopy Images

Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data

)301( COPYRIGHT 2018 BY THE ARCHIVES OF BONE AND JOINT SURGERY

For Commercial products, please refer to the following policy: Preauthorization via Web-Based Tool for Procedures

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

Transcription:

Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty A. J. Price, A. Short, C. Kellett, D. Beard, H. Gill, H. Pandit, C. A. F. Dodd, D. W. Murray From the Nuffield Orthopaedic Centre, Oxford, England Polyethylene particulate wear debris continues to be implicated in the aetiology of aseptic loosening following knee arthroplasty. The Oxford unicompartmental knee arthroplasty employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. This study measures the in vivo ten-year linear wear of the device, using a roentgenstereophotogrammetric technique. In this in vivo study, seven medial Oxford unicompartmental prostheses, which had been implanted ten years previously were studied. Stereo pairs of radiographs were acquired for each patient and the films were analysed using a roentgen stereophotogrammetric analysis calibration and a computer-aided design model silhouette-fitting technique. Penetration of the femoral component into the original volume of the bearing was our estimate of linear wear. In addition, eight control patients were examined less than three weeks postinsertion of an Oxford prosthesis, where no wear would be expected. The control group showed no measured wear and suggested a system accuracy of 0.1 mm. At ten years, the mean linear wear rate was 0.02 mm/year. The results from this in vivo study confirm that the device has low ten-year linear wear in clinical practice. This may offer the device a survival advantage in the long term. " A. J. Price, DPhil, FRCS(Orth), Clinical Lecturer & Honorary Consultant Orthopaedic Surgeon " A. Short, DPhil, Research Engineer " C. Kellett, FRCS, Specialist Registrar " D. Beard, DPhil, University Research Lecturer " H. Gill, DPhil, University Research Lecturer " H. Pandit, FRCS(Orth), Research Fellow " C. A. F. Dodd, FRCS, Consultant Orthopaedic Surgeon " D. W. Murray, MD, FRCS(Orth), Professor Orthopaedic Surgery Nuffield Orthopaedic Centre, Windmill Road, Headington, Oxford OX3 7LD, UK. Correspondence should be sent to Mr A. J. Price; e-mail: andrew.price@ndos.ox.ac.uk 2005 British Editorial Society of Bone and Joint Surgery doi:10.1302/0301-620x.87b11. 16325 $2.00 J Bone Joint Surg [Br] 2005;87-B:1493-7. Received 24 January 2005; Accepted after revision 14 June 2005 Polyethylene wear remains a major factor in the failure of knee replacements. 1 In the shorter term, catastrophic failure can result in early revision. 2 In the medium- to long-term wear particles are implicated in the pathogenesis of osteolysis and the production of aseptic loosening. 3 Theoretically reducing contact stress at the bearing surface can decrease wear. 4 The use of a fully congruent mobile bearing increases contact area, decreases contact stress and therefore reduces the potential for formation of wear particles. 5 The Oxford unicompartmental knee arthroplasty (UKA; Biomet, Swindon, UK) employs a meniscal bearing and was designed in an attempt to reduce wear. 6 In vitro measurement of polyethylene wear using laboratory simulators and retrieval studies have suggested that the device can produce low wear rates, when functioning normally. 7,8 However, these findings have not been confirmed in vivo. This study combines roentgenstereophotogrammetric analysis (RSA) and computer-aided design models to produce a system for calculating in vivo polyethylene wear as previously applied to assess a total knee replacement. 9,10 Our aim was to measure linear wear occurring in meniscal-bearing unicompartmental knee replacements at a minimum follow-up of ten years. Patients and Methods Measuring wear. A stereo pair of radiographs was simultaneously taken of each knee studied. The technique required the subject to stand on both legs, with the study knee placed within a calibration frame, which is a rigid, triangular open-ended structure. The three planes of the frame contained tantalum marker balls (0.8 mm in diameter) in accurately-known positions relative to a coordinate system embedded in the calibration frame. The marker balls gave rise to image points on the stereo radiographs. The relationship between the three-dimensional coordinate system of the frame and the twodimensional coordinate system of each radiograph was then determined. The process of calculating this relationship is called calibration. Once both images were calibrated, the threedimensional coordinates of any object visible in both images could be calculated with a high degree of accuracy. The images were then processed to detect the silhouettes of the metal components of the VOL. 87-B, No. 11, NOVEMBER 2005 1493

1494 A. J. PRICE, A. SHORT, C. KELLETT, D. BEARD, H. GILL, H. PANDIT, C. A. F. DODD, D. W. MURRAY Table I. Details of the control group Case Gender* Side (yrs) Age at surgery Time since surgery (days) 1 F R 68.2 7 2 M R 64.4 6 3 F L 66.3 6 4 F R 61.3 14 5 M L 57.1 6 6 F L 75.9 14 7 F L 79.2 7 8 F L 59.2 21 Mean (SD) 66.5 (7.8) 10.1 (5.6) * F, female; M, male all patients had unilateral procedures with phase 3 prostheses; R, right; L, left implant. These were separated into the femoral and tibial component silhouettes. For each component, a virtual silhouette could be generated using the photogrammetric relationship determined by calibration and the appropriate computer-aided design (CAD) model of the component. The model was considered to be placed within a virtual representation of the calibration frame, the projected image giving rise to the virtual silhouettes on each radiograph. The position of the CAD model was systematically adjusted to minimise the mismatch between the actual and virtual silhouettes. This allowed accurate calculation of the threedimensional location of each component. Validation of this method has been described previously. 10 The Oxford UKA has a flat tibial component and a spherical femoral component. Determination of the threedimensional positions of each allows the smallest perpendicular distance between the articulating surfaces of these components to be calculated. This represents the minimum of the bearing, which separates the two metal components. Minor differences in extra-articular bearing shape do not affect the method. By comparing the RSAcalculated bearing with the known of the bearing at time of insertion, the linear wear can be estimated. Estimating bearing at insertion. The nominal size of each bearing studied was known, but manufacturing tolerance introduces some variation to this value. To assess the degree of variation the minimum of 20 unused bearings was measured with a dial gauge. The mean difference in measured to nominal was + 0.05 mm (SD 0.07). Therefore, for all other calculations the of the polyethylene bearing before implantation was taken to be the nominal + 0.05 mm. Control group. As a control, eight patients who were undergoing a medial Oxford UKA were recruited and each had RSA radiographs taken after their operation. The implants were all phase 3 Oxford UKA. This prosthesis is manufactured using a CAD model, which had been made available for the experiment by the manufacturer. Using the system described above, the linear penetration of the femoral component into the bearing was measured, within three weeks of insertion, when it could be assumed no wear had occurred. The measured of polyethylene was compared with the of the bearing at insertion. The details of these patients are given in Table I. Study group. Patients were recruited from a series of medial Oxford UKAs performed by John Goodfellow, one of the designers of the prosthesis. 4,11 An accurate database of the 144 knees in 114 patients was available. All patients had undergone a medial Oxford UKA for anteromedial osteoarthritis, with a functioning anterior cruciate ligament and correctable varus deformity of the knee at the time of surgery. The recruitment of suitable patients from this database involved the following criteria: 1) the patients had to be alive, 2) have received the phase 2 prosthesis to enable the use of a single CAD model, 3) be living in the Oxfordshire region, and therefore not precluded by distance from reattending and 4) have received their prosthesis approximately ten years earlier. From the original 114 patients, seven were identified of whom five (seven knees) agreed to take part in the study. All patients completed an Oxford Knee Score questionnaire 12 and their knees were evaluated using the American Knee Society (knee and function) score. 13 The demographic and clinical details of the patients are given in Table II. All bearings assessed were made using the same manufacturing process and tolerance. There were minor differences in the extra-articular shape of the phase 2 and 3 Table II. Details of the study group Case Gender* Side unilateral Bilateral/ Phase Age at surgery (yrs) Time since surgery (yrs) OKS (0 to 48) AKS score (knee) (0 to 100) AKS score (function) (0 to 100) 1 F R Unilateral 2 57.3 10.0 45 100 100 2 F R Bilateral 2 58.6 10.2 45 98 100 3 F L Bilateral 2 58.6 10.2 45 98 100 4 F R Unilateral 2 39.9 11.0 40 90 90 5 F L Unilateral 2 65.7 11.2 39 85 90 6 F R Bilateral 2 67.4 13.3 42 90 90 7 F L Bilateral 2 67.4 13.3 42 90 90 Mean (SD) 59.3 (9.61) 11.3 (1.44) 42.6 (2.5) 93.0 (5.6) 94.3 (5.3) * F, female R, right; L, left OKS, Oxford Knee Score 12 AKS, American Knee Society 13 THE JOURNAL OF BONE AND JOINT SURGERY

TEN-YEAR IN VIVO WEAR MEASUREMENT OF A FULLY CONGRUENT MOBILE BEARING UNICOMPARTMENTAL KNEE ARTHROPLASTY 1495 Penetration 0.3 0.2 0.1 0-0.1-0.2-0.3 1 2 3 4 5 6 7 8 Mean Specimen number Fig. 1 The difference in measured from estimated at insertion for the control bearings. The mean value (95% confidence interval) is also displayed. Penetration 1.2 1.0 0.8 0.6 0.4 0.2 0.0-0.2 Controls Ten-year bearings -0.4-2 0 2 4 6 8 10 12 14 Time since insertion (yrs) Fig. 2 The measured penetration for each control and study bearing plotted against time. The gradient of the line plotted represents the mean wear rate. bearings used in this study, but importantly the intra-articular shape remained the same. The patients who agreed to enter the study had RSA radiographs taken and linear wear was calculated. For six knees, two sets of radiographs were taken, one in full extension and the other at 30 of flexion. One patient (one knee) declined the second set of radiographs. The full congruency of the articulation should not affect the measurement of bearing regardless of the degree of knee flexion. Therefore, comparison of the two measurements provided a test of reproducibility. Ethical approval for our radiographic study was given by the local ethics committee. Results The penetration measurements of the control bearings are displayed in Figure 1. The mean difference was 0.05 mm (95% confidence interval (CI) 0.01). The details of all linear wear measurements made for the study group are shown in Table III. From the six knees within the study group where two different pairs of radiographs had been taken, the mean difference between penetration measurements was 0.01 mm (95% CI 0.07). In one bearing, the mean penetration measurement was negative, but positive values were recorded for the others. Individual linear wear rates for each bearing have been calculated by dividing measured penetration by the time since insertion (years). The highest linear wear rate was 0.05 mm/year, but four bearings were wearing at approximately 0.02 mm/year. The mean penetration rate was 0.02 mm/year (95% CI 0.01). The results are summarised in Figure 2, which displays the linear wear measurements for each of the study and control bearings plotted against time. The error bars around the study bearings represent the error of the system (SD 0.01), estimated from the confidence interval around the control and repeated measurements. The mean linear wear rate of the study bearings is represented by the gradient of the line. Table III. Polyethylene penetration and calculated wear rates for study bearings. Where two pairs of radiographs were obtained the difference in penetration measurements is also displayed Case Years since surgery Nominal bearing size Nominal Adjusted Nominal + 0.05 Measured 0 flexion 30 flexion Measured difference (0 to 30 ) Penetration 0 flexion 30 flexion Penetration mean (0 + 30 )/2 Linear wear rate (mm/yr) 1 10.0 2 5.5 5.55 5.380 5.260 0.120 0.170 0.290 0.230 0.023 2 10.2 2 5.5 5.55 5.420 5.380 0.040 0.130 0.170 0.150 0.015 3 10.2 3 6.5 6.55 6.540 6.520 0.020 0.010 0.030 0.020 0.002 4 11.0 2 5.5 5.55 5.040 - - 0.510-0.510 0.046 5 11.2 3 6.5 6.55 6.520 6.660-0.140 0.030-0.110-0.040-0.004 6 13.3 0 3.5 3.55 3.140 3.150-0.010 0.410 0.400 0.405 0.030 7 13.3 2 5.5 5.55 5.080 5.050 0.030 0.470 0.500 0.485 0.036 Mean 0.010 0.251 0.021 95% CI* 0.068 0.164 0.013 * CI, confidence interval VOL. 87-B, No. 11, NOVEMBER 2005

1496 A. J. PRICE, A. SHORT, C. KELLETT, D. BEARD, H. GILL, H. PANDIT, C. A. F. DODD, D. W. MURRAY Discussion A combination of RSA techniques and CAD technology provided the methodological basis for measuring wear. The reported control experiments describe a system error of approximately 0.10 mm. The repeated measurements from the study group confirm that the method was repeatable. The radiation exposure from a stereo pair of RSA radiographs represents a very small relative risk to the patient, with the total dose equivalent to approximately three weeks of background radiation. It is concluded that the in vivo method for measuring polyethylene penetration is accurate, reliable and presents minimal risk to patients. The value for penetration represents a combination of creep and linear wear. Delineating the relative contribution of the two processes is a limitation of this method and the measurements represent an overestimation of wear. However the majority of creep is believed to occur within three months of implantation. 14,15 Therefore at ten years post-operation the proportion of true wear to creep will increase, reducing the contribution of creep to the penetration value. The mean in vivo wear rate for the group of ten-year Oxford UKAs was 0.02 mm/year. This figure represents a low wear rate and is similar in magnitude to both the 0.01 mm/year measured with in vitro wear testing, and the value estimated from retrieved bearings with normal macroscopic wear patterns. 7,8 The patients within the study group had good clinical outcomes and the results provide evidence that low wear rates are maintained for up to ten years in patients in whom the device works well. A low wear rate in itself would not be expected to produce any functional outcome benefit for the patient in the shortterm, but should offer the prosthesis a survival advantage, enhancing its longevity. The range of wear rates was -0.004 to 0.046 mm/yr (Table III). The apparent increase in bearing suggested by the negative value probably reflects the error introduced in estimating the original bearing. The mean wear rate of 0.02 mm/year measured in the in vivo study compares favourably with the published results of polyethylene penetration for other forms of arthroplasty which use a metal-on-polyethylene bearing. The value is approximately ten times less than the penetration rates of 0.1 to 0.2 mm/year reported for total hip arthroplasty. 16-18 Despite many published retrieval studies there are few reports of the linear penetration rate in total knee arthroplasty. Plante-Bordeneuve and Freeman 19 reported a mean wear rate of 0.025 mm/year for a conforming total knee arthroplasty (TKA), with a large contact area. However, this device did not afford axial rotation. Contemporary, unconstrained TKAs have penetration rates of around 0.2 mm/year, reflecting their lower contact area. 9,20 Ashraf et al 21 reported a penetration rate of 0.15 mm/year for the St. Georg Sledge fixed-bearing UKA prosthesis. There are no other published penetration rates for fixed-bearing devices, but early catastrophic polyethylene wear has been a problem with many designs and it is safe to assume that linear penetration rates were high in these cases. 2,22,23 Despite high linear wear rates measured in some retrieved specimens, catastrophic wear was not a feature with the Oxford device. The use of in-air gamma-irradiated polyethylene may have been a factor in these findings, but low conformity and high contact stress may predispose fixedbearing devices to more aggressive wear patterns. The RSA system reported in this paper has a number of possible applications. It can be used as an outcome tool for monitoring the wear of established prostheses in the long term and provides a complimentary method to the other forms of assessing polyethylene wear. Additionally, it could be used for studying wear in new designs of prosthesis as they are introduced. The current RSA system can measure wear of approximately 0.1 mm. Wear rates in TKA are approximately 0.1 mm/year, therefore, the system could potentially be used to measure wear at two to three years post-implantation. The system could be employed to identify accelerated wear, which may predispose to early failure. The Oxford meniscal-bearing arthroplasty was designed to reduce wear, a factor that has adversely affected the results of fixed-bearing unicompartmental replacements. The results from this in vivo study confirm that low wear rates can be achieved and maintained in the long term. The author or one or more of the authors have received or will receive benefits for personal or professional use from a commercial party related directly or indirectly to the subject of this article. In addition, benefits have been or will be directed to a research fund, foundation, educational institution, or other nonprofit organisation with which one or more of the authors are associated. References 1. Goodman S, Lidgren L. Polyethylene wear in knee arthroplasty: a review. Acta Orthop Scand 1992;63:358-64. 2. Palmer SH, Morrison PJ, Ross AC. Early catastrophic tibial component wear after unicompartmental knee arthroplasty. Clin Orthop 1998;350:143-8. 3. Engh GA, Ammeen DJ. Periprosthetic osteolysis with total knee arthroplasty. Instr Course Lect 2001;50:391-8. 4. Goodfellow J, O Connor J. The mechanics of the knee and prosthesis design. J Bone Joint Surg [Br] 1978;60-B:358-69. 5. O Connor JJ, Goodfellow JW. Theory and practice of meniscal knee replacement: design against wear. Proc Inst Mech Eng [H] 1996;210:217-22. 6. Goodfellow J, O Connor JJ, Murray D. Principles of meniscal bearing arthroplasty for unicompartmental knee replacement. In: Cartier P, Epinette JA, Deschamps G, Hernnigou P, eds. Unicompartmental arthroplasty. First ed. Paris: Expansion Scientific Francaise, 1997. 7. Psychoyios V, Crawford RW, O Connor JJ, Murray DW. Wear of congruent meniscal bearings in unicompartmental knee arthroplasty: a retrieval study of 16 specimens. J Bone Joint Surg [Br] 1998;80-B:976-82. 8. Scott R, Schroeder D. Correlation of knee similar to in vivo use: evaluating the Oxford unicompartmental knee [abstract]. Trans Orthopaedic Research Society 2000: 434. 9. Kellett K, Short A, Price A, Gill H, Murray D. In vivo measurement of total knee replacement wear. The Knee 2004;11:183-7. 10. Short A, Gill H, Marks B, et al. A novel method for in vivo knee prosthesis wear measurement. J Biomech 2005;38:315-22. 11. Murray DW, Goodfellow JW, O Connor JJ. The Oxford medial unicompartmental arthroplasty: a ten-year survival study. J Bone Joint Surg [Br] 1998;80-B:983-9. 12. Dawson J, Fitzpatrick R, Murray D, Carr A. Questionnaire on the perceptions of patients about total knee replacement. J Bone Joint Surg [Br] 1998;80-B:63-9. 13. Insall JN, Ranawat CS, Aglietti P, Shine J. A comparison of four models of total knee-replacement prostheses. J Bone Joint Surg [Am] 1976;58-A:754-65. 14. Deng M, Latour RA, Ogale AA, Shalaby SW. Study of creep behavior of ultra-highmolecular-weight polyethylene systems. J Biomed Mater Res 1998;40:214-23. THE JOURNAL OF BONE AND JOINT SURGERY

TEN-YEAR IN VIVO WEAR MEASUREMENT OF A FULLY CONGRUENT MOBILE BEARING UNICOMPARTMENTAL KNEE ARTHROPLASTY 1497 15. Lee KY, Pienkowski D. Compressive creep characteristics of extruded ultra-highmolecular-weight polyethylene. J Biomed Mater Res 1998;39:261-5. 16. Kabo JM, Gebhard JS, Loren G, Amstutz HC. In vivo wear of polyethylene acetabular components. J Bone Joint Surg [Br] 1993;75-B:254-8. 17. Wroblewski BM. Direction and rate of socket wear in Charnley low-friction arthroplasty. J Bone Joint Surg [Br] 1985;67-B:757-61. 18. Schmalzried TP, Callaghan JJ. Wear in total hip and knee replacements. J Bone Joint Surg [Am] 1999;81-A:115-36. 19. Plante-Bordeneuve P, Freeman MA. Tibial high-density polyethylene wear in conforming tibiofemoral prostheses. J Bone Joint Surg [Br] 1993;75-B:630-6. 20. Hoshino A, Fukouka Y, Ishida A. Accurate in vivo measurement of polyethylene wear in total knee arthroplasty. J Arthroplasty 2002;17:490-6. 21. Ashraf T, Newman JH, Desai VV, Beard D, Nevelos JE. Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis. The Knee 2004;11:177-81. 22. Engh GA, Dwyer KA, Hanes CK. Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. J Bone Joint Surg [Br] 1992;74-B:9-17. 23. Lindstrand A, Stenstrom A, Lewold S. Multicenter study of unicompartmental knee revision: PCA, Marmor, and St Georg compared in 3,777 cases of arthrosis. Acta Orthop Scand 1992;63:256-9. VOL. 87-B, No. 11, NOVEMBER 2005