Top Vent Study: Optimizing Urine Collection System Flow to Improve Patient Outcomes

Similar documents
Exacta EXTERNAL DRAINAGE AND MONITORING SYSTEM

gentle catheter clip USER GUIDE optimum medical support optimummedical independence with confidence

Exacta EXTERNAL DRAINAGE AND MONITORING SYSTEM

Continuous Bladder Irrigation

catheter strap USER GUIDE optimummedical support independence with confidence

sleeve leg bag holder

THE UROLOGY GROUP

How to Change a. Foley catheter. Patient Education Rehabilitation Nursing. Step-by-step instructions for the caregiver

Suprapubic and Mitrofanoff Catheter Care

CATHETERS: INSERTION, TIPS, AND TYPES - DALHOUSIE UNIVERSITY

Neurogenic Bladder: What You Should Know. A Guide for People with Spinal Cord Injury

Catheter Care How to Care for a Urinary Catheter

Managing your suprapubic catheter

What is a catheter? What do I need to learn about catheter care?

Loss of Bladder Control

Silver makes it better. Silicone makes it best. COMPLICATIONS RELIABILITY & FUNCTION COATINGS PRODUCT INFORMATION

Urinary Catheter or Urinary Tract Infection Critical Element Pathway

Going Home with a Urinary Catheter and an All in One Day/Night Drainage Bag

Guide for Use. Apogee Plus Touch Free Intermittent Catheter System

Becker external drainage and monitoring system

Caring for your indwelling urinary catheter

Caring for Your Urinary (Foley ) Catheter

Solutions for Urological Care

Grey Bruce Health Network EVIDENCE-BASED CARE PROGRAM PATIENT EDUCATION BOOKLET TURP (TRANS URETHRAL RESECTION OF THE PROSTATE) PATHWAY

3. Urinary Catheters. Indications. Methods of Bladder Catheterization. Hashim Hashim

Observed underpressure in the urine drainage bag tube, when using ecinput

Urological Care. External Male Catheters. Gizmo Male External Catheter. Freedom Clear Advantage Catheter. Freedom Cath Catheter

Caring for a Nephrostomy and what is Ureteric Stenting

Solutions Urological Care

NHS GREATER GLASGOW & CLYDE CONTROL OF INFECTION COMMITTEE STANDARD OPERATING PROCEDURE (SOP) INSERTION & MAINTENANCE OF INDWELLING

How to Care for a Foley Catheter After Surgery

Achieving Independence. A Guide to Self-Catheterization with the Bard Touchless Plus Intermittent Catheter System

LESSON ASSIGNMENT. Urinary System Diseases/Disorders. After completing this lesson, you should be able to:

MP A Prospective Evaluation of the Catheter Science M3 Mini Catheter for Patients with Prostatic Obstruction. Gaines W. Hammond Jr.

A word about incontinence

Evidence Summary: The inflow Urinary Prosthesis FDA De Novo Approval DEN130044

Indwelling Urinary Catheters And Drainage systems

CARING FOR YOUR CATHETER AT HOME

Discussions about having a Supra pubic catheter

BARD LATEX FOLEY CATHETERS. Together, advancing the world of health. Utilization. Insertion. Maintenance. Duration

CATHETERIZATION TRAINER ON A STAND

Instruction Guide to Sterile Intermittent Catheterization For Parents of Girls Using the Cure Catheter Closed System

Loss of Bladder Control

Your catheter. Information for patients and carers. NHS Grampian Continence Service

What you should know about your diagnosis of incontinence

Parts identification:

O3_A2_A_Scientific Evidence

Device and Activator. Table of Contents INFORMATION FOR PATIENTS AND INSTRUCTIONS FOR USE

Instruction Guide to Sterile Self-Intermittent Catheterization For Men Using the Cure Catheter Closed System

Benign Prostatic Hyperplasia Case Study 2. Medical Student Case-Based Learning

TRUSTED, QUALITY PRODUCTS TO ADDRESS YOUR UROLOGICAL NEEDS. Extended Care Urology Products

Kelly procedure. How does the urinary system work? What is a Kelly procedure and why does my child need one?

Achieving Independence

Guide for Use. Apogee Plus Touch Free Intermittent Catheter System

GASTRO-INTESTINAL (ENTERAL)

TURP - TransUrethral Resection of the Prostate

Talk about Clean Intermittent Catheterisation (CIC)

Sterile Intermittent Catheterization for Women

Indwelling urinary catheter

Urodynamic Studies. (Testing the bladder)

Instruction Guide to Clean Self-Intermittent Catheterization For Women Using the Extra Long Cure Medical Pocket Catheter

The Urinary System. 1. Define important words in this chapter. 2. Explain the structure and function of the urinary system

Intermittent self-catheterisation (ISC) Information for patients Spinal Injuries

Chapter 18. Assisting With Urinary Elimination. Elsevier items and derived items 2014, 2010 by Mosby, an imprint of Elsevier Inc. All rights reserved.

Advanced Catheterisation Trainer User Guide

Using a leg bag. drainage tube. leg bag. spout

Designed to offer choices that empower life. Relative Recovery of Staphylococcus aureus. Intermittent Catheter 3. Intermittent Catheter 2

The inflow. Active Urologic Practice. Clinical Background and Urology Practice Overview

limbsandthings.com Advanced Catheterisation Trainer User Guide For more skills training products visit Limbs & Things Ltd.

A Patients Guide to Caring for a Nephrostom y Tube at Home

Shropshire s Continence Advisory Service INDWELLING URINARY CATHETERS

Loss of Bladder Control

Preventing CLABSI & CAUTI Preventive Measures for Central Line Associated Bloodstream Infection & Catheter Associated UTI

FreshRN Podcast Season 4, Episode 6. All Things Urinary Catheters

Clean Intermittent Self-Catheterisation (CISC)

Managing your bladder with a Supra-pubic catheter at home

Designed for fast* and convenient cathing. * No additional waiting time once the catheter has been wetted

Procedure Specific Information Sheet Open Radical Prostatectomy

Types of Intermittent Catheters and Access to Urological Supplies

Indwelling Urinary Catheter Template for Care Plan Development Problem No: be a last resort when all suprapubic catheter in CAUTI

CATHETER PASSPORT. Looking after your Urinary Catheter. The Catheter Passport should be given to all patients with a urinary catheter.

Prostate surgery. What is the prostate? What is a TURP? Why is a TURP operation necessary? Deciding to have a TURP operation.

Slide 1. Slide 2. Slide 3. Bladder Management and Preventing CAUTI. Bladder management CAUTI prevention standards

AMSure UROLOGICAL CARE

THE BULKING AGENT WITH LONG-LASTING EFFECT!

limbsandthings.com Advanced Female Catheterisation Trainer User Guide For more skills training products visit Limbs & Things Ltd.

Suprapubic catheter insertion in the radiology department. Information for patients Urology

Bladder Management. Why is a Bladder Program so Important?

Indwelling urinary catheters for managing your bladder. Information for patients Northern General Hospital

Getting Ready. My Child Is Having A VCUG

Loss of Bladder Control

My urinary catheter passport

Guide for Use. Advance Plus Touch Free Intermittent Catheter System

EVOLVE LASER PROSTATECTOMY

CYSTOSCOPY & TRANSURETHRAL RESECTION OF THE PROSTATE

NHS Urinary Catheter Passport

Nephrostomy Tube Urology Patient information Leaflet

Ileal Conduit Diversion Surgery

Nephrostomy. Radiology Department. Patient information leaflet

Transcription:

Top Vent Study: Optimizing Urine Collection System Flow to Improve Patient Outcomes Stephen Tully, R&D Project Engineer, Tyco Healthcare Group LP, Kendall Division, Mansfield, MA

Top Vent Study: Optimizing Urine Collection System Flow to Improve Patient Outcomes Clinical problem: Current urine collection systems frequently cause sustained positive and negative pressure events on patient s bladders under normal operating conditions. These pressure events create two main consequences in the clinical setting: 1) patient discomfort and 2) lack of urine flow which would require caregiver intervention. Occur When Potentially Lead To Nurse Intervention Required Stephen Tully, R&D Project Engineer, Tyco Healthcare Group LP, Kendall Division, Mansfield, MA Positive Pressure Back Pressure Events Urine needs to travel uphill i.e. when tubes are hung below the inlet on the bag in a U-shape. Bladder distention Bladder fullness / Urge to void Meatal leakage Manually lifting the drain tube to empty urine in drain tube. Negative Pressure Suction Events Tubes are manually emptied. At the transition from high to low flow. Flow is restricted Patient pain Bladder lesions Bladder spasm Manipulating the system to enable flow. Recent bladder cystoscope photographs show edema and vascular trauma after only a 20 minute catheterization. This trauma is most likely due to suction events. and typical collection system positioning. This system was utilized to compare the performance of non-vented and DOVER vented collection systems for the following events: Back pressure Pressure differential Suction Test Results: Back Pressure: System pressure was measured at a position to simulate bladder pressure with clinically relevant flow rates. The drain tubes were placed in a typical uphill-flow condition. Airlock, resulting from uphill urine flow, causes back pressure on the patient s bladder, restricting urine flow. Without top vents, these sustained back pressure events last until the full tubes are manually emptied into the bag or meter. Current non-top vented systems created sustained back pressure events between 26-34cm of water pressure. The new DOVER top vented urine meters and drain bags measured no sustained positive back pressure events. Test Results: Pressure Differential At the conclusion of the back pressure test, the drain tubes were manually emptied to achieve system flow. The system pressure was recorded in order to compare the pressure drop for top vented vs. non-top vented systems. In a traditional non-top vented system, this pressure change creates a sustained pressure event within the bladder. Pre-Catheterization Post-Catheterization Photographs provided by Dr. Joseph Grocela at Massachusetts General Hospital Solution: DOVER Top Vent Technology: (Top Vent) In-vitro tests demonstrate that DOVER top vents effectively prevent bladder pressure events. They do this by allowing air into the system to prevent suction events and by allowing air to escape the system to prevent back pressure events. The new DOVER top vent filter has an inner membrane that allows air to pass through it in either direction without wetting-out during use. It also acts as a bacterial and viral barrier with greater than 99.99% efficiency. Test System: To better understand bladder pressure events, the Kendall Urology R&D group interviewed caregivers, observed drainage systems in use at various hospitals, and designed an in-vitro system in consultation with fluid dynamics experts. This system simulates patient use and accurately measures pressures near the patient using clinically relevant flow rates Non-top vented systems measured average pressure drops of 68cm of water. The new DOVER top vented systems measured a pressure drop of 23cm of water or a 66% reduction. Test Results: Suction: For this bench test, a balloon was placed over a Foley catheter tip to simulate a bladder, and the time to empty 60cc of water from the drain tube was measured with a stopwatch. Non-top vented systems took an average of 17.1 seconds to empty all of the fluid. The new DOVER top vented systems took an average of only 4.2 seconds (a 75% reduction in caregiver intervention time). While the drain tubes were emptying, a suction event was observed pulling the balloon into the eyehole (left photo). This event releases as soon as the tubing is fully cleared (right photo). Top vents were also shown to prevent suction (Suction Event) events in the bladder which are caused by flow restrictions. Conclusions: In-vitro bench testing in this paper shows that the new DOVER Urine Collection systems with top vents prevent any sustained back pressure or suction events in order to maximize urine flow and improve patient comfort. Clinical trials are warranted to confirm these in-vitro results. It also shows a significant decrease in nursing intervention to correct these pressures. 2

INTRODUCTION: All urine collection systems are designed to be gravity dependent. There are many challenges in the clinical environment that can compromise the system flow. These include bed limitations, drain bag and tube positioning, flow obstructions etc. Until now, very little has been published regarding the pressures involved during typical urine collection system use. The Kendall R&D Urology group interviewed caregivers and observed collection systems in use at various hospitals. Here is a summary of the findings. Positive Pressure Events Back Pressure : The team observed that the most common way of hanging collection systems was to let the drain tube hang down on the side of the bed below the drain bag or urine meter so that urine has to flow uphill. Nurses regularly need to lift up the drain tube in order to empty the pooled urine into the bag or meter in this configuration. This is sometimes done in order to relieve patient discomfort and bladder fullness complaints which are most likely created by these sustained back pressure events. Explanation: With current non - top vented systems, urine flows from the catheter down through the drain tube and pools at the lowest point in the drain tube. Once urine fills the tube at the low point, the air between the catheter and urine pool is trapped. The bag vents are not effective because the pooled urine is in the way. This airlock situation creates a sustained positive pressure on the patient s bladder while the bladder empties until the pooled urine is manually emptied into the drain bag. Negative Pressure Events Suction : Urine collection systems are often susceptible to urine back-up near the entry point into the bag or meter. This situation was observed first-hand in hospitals. When this occurs, nurses typically have to either shake the drain tube or drop the bag or meter to the floor in order to get urine flow into the bag or meter. Why This Bench Test Was Developed: This bench test was developed in order to understand the effects of positive and negative pressure events near the patient s bladder in limiting urine flow through collection systems during realistic-use conditions. With this bench test, both urine flow rates and drain tube configurations can be varied in order to measure the corresponding pressures in the system. Through bench testing and observing collection systems in-use, the Kendall Urology R&D group has been able to understand and consistently simulate which conditions cause these pressure events and develop a new top vented urine collection system. How Top Vents Work: Top vents (see Photo #1 below) are designed to equalize collection system pressures in order to prevent pressure events from affecting the patient s bladder. They do this by allowing air into the system to prevent siphon events and allowing air to escape the system to prevent back pressure events. These top vent filters have a plastic inner membrane that will not wet-out during use. This membrane also acts as a bacterial and viral barrier with greater than 99.99% efficiency. (Top Vent) Photo #1 This white paper describes the In-vitro bench test and provides test results in order to show the benefits of new DOVER top vented urine collection systems. Explanation: With current non-top vented systems, this urine back-up is caused by flow restrictions which can prevent urine from freely entering the bag or meter. This includes any restriction in diameter along the urine flow path. When this occurs, a meniscus or air bubble forms, which is difficult to break. Bench testing has shown that this situation causes a suction event until it is broken up. Suction events have also been shown to occur at the transition point between high to low urine flow i.e. at initial void or when drain tubes are manually emptied. 3

MATERIALS AND METHODS Test System Description: This In-vitro bench test was designed for the Kendall Urology R&D group by a fluid dynamics consulting company in order to evaluate different urine collection system designs. It accurately measures both positive and negative system pressures near the catheter, using highly sensitive pressure transducers, during realistic flow conditions. Below is a picture of the test setup (see photo #2). Back Pressure Test: Photo #2 Photo #3 Suction Test #1A Pressure Differential: At the end of the above back pressure test, in the final 30 seconds without flow, system pressures were measured in order to simulate the caregiver manually emptying the drain tube fluid into the collection bag or meter. This was done in order to measure the pressure difference between the back pressure event caused by forcing urine flow uphill and the suction event that is created when caregivers empty the fluid contents into the bag or meter. System pressure was measured on a pressure transducer at a position to simulate bladder pressure with the following flow rate program, designed to simulate a clinically relevant initial void from a full bladder with the drain tubes placed in a U- shaped uphill-flow condition (see photo #3, top right): BACK PRESSURE TEST PROGRAM TIME (sec) 15 250 30 100 120 5 Table #1 FLOW RATE (ml/min) 30 0 HEAD HEIGHT: 12" from catheter level to hanger level Three different premium drain bag and urine meter types were tested (n=5 each): Tyco Healthcare / Kendall codes 6308 bag & 7000 meter (without top vents). C.R. Bard codes 154102 bag & 153304 meter (without top vents). New DOVER codes PP bag & P4P meter (with top vents). 4 Suction Test #1B Drain Tube Clearing: This In-vitro test relates to the suction test #1A above, but instead of measuring pressure differential, this test measures the time it takes to empty 60cc of fluid from the drain tube in typical closed systems. Ten new DOVER drain bag codes with and without top vents were tested to the procedure below. Test Procedure: The drain tube was filled with 60cc of distilled water. A balloon was securely fastened to an 18F catheter to simulate the bladder (see photo #4 on page 5). The tube was lifted, and the time to fully empty all of the fluid into the drain bag was recorded with a stopwatch. The balloon was also observed for suction events while the tubes were clearing. Suction Test #2 Flow Restriction: For this test, a technique was developed to cause suction events every time on all non-top vented collection systems. That way, the top vent effectiveness could be evaluated when suction events occur. These suction events were artificially created by placing a restriction into the drain tube near the bag inlet chamber. This restriction causes a meniscus or air bubble to form which restricts flow and causes suction events.

RESULTS BACK PRESSURE TEST RESULTS: Below are the graphical results from this test. Five samples were tested for each urine collection system type and averaged for this graph (see graph #1 below). Photo #4 System pressure was measured on a calibrated pressure transducer at a position to simulate bladder pressure with the following flow rate program to simulate worst case suction event conditions. A two-hump fixture was designed to simulate patient movement on the drain tube. The duration of hold and movement was designed to push large boluses of fluid into the flow restriction to create siphon events. Two different drain bag and urine meter types were tested with this artificial flow restriction: New DOVER codes (PA & P4A) without top vents. New DOVER codes (PP & P4P) with top vents. SUCTION TEST PROGRAM TIME (sec) Table #2 FLOW RATE (ml/min) 60 250 30 150 120 5 20 0 DURATION OF HOLD (sec) PROFILE 0 to 90 Degrees DURATION OF MOVEMENT (sec) 25 5 25 5 10 10 5 5 25 10 20 5 HEAD HEIGHT: 12" from catheter level to hanger level Graph #1 Using this bench test, it was discovered that uphill flow to the bag or meter caused back pressure events on the patient s bladder every time without top vents. The two non-top vented urine meters with longer drain tubes had the higher sustained back pressure events (32-34 centimeters of water pressure) compared to the two nontop vented drain bags (26-28 centimeters of water pressure). This makes sense because urine had to flow farther uphill with the longer drain tubes. Both new drain bag and urine meter versions with top vents produced no positive back pressure events stayed near the zero pressure line on the x-axis. SUCTION TEST RESULTS: TEST 1A Pressure Differential Test As the tubes were lifted, the results show a drop from positive back pressure to negative suction events. For both the current Kendall and Bard systems without top vents, the average pressure drop measured 68cm of water pressure when emptying the drain tube fluid. For the new DOVER systems with top vents, the average pressure drop measured only 23cm of water pressure. This represents a 66% reduction in pressure differential in this clinically relevant situation (see graph #2 below). 5

Pressure Drop (cm H2O) Siphon Test #1: Average Bag & Meter Pressure Drop When Emptying Drain Tube in U-Shape 60 50 40 30 20 10 0 22.8 New Kendall Top Vented 57.5 57.8 Current Kendall Non Top Vented Current Bard Non Top Vented Without top vents, these suction events reach up to negative 18 cm of water and last until the restriction is broken by either water head height pressure above it or by manually shaking the system near the restriction to break it up. With top vents, the same systems do not allow any sustained suction events (stay near the zero line). They do this by allowing air into the system to eliminate the negative pressure (see graph #3 below). Graph #2 TEST 1B Drain Tube Clearing Test Along with the above pressure differential improvement, the time that it takes for the caregiver to clear the drain tube, and the suction event duration is also reduced for top vented systems. With top vents, it only takes an average of 4.2 seconds to empty 60cc of urine from closed collection system drain tubes. This represents a 75% reduction in the time it takes for caregivers to clear drain tubes with non-top vented systems. Graph #3 When these drain tubes are manually emptied by caregivers, a suction event can be seen sucking the balloon (simulated bladder) into the catheter eyehole for the entire duration until the tubing is cleared (see photos #5 & #6 for the suction and no suction event comparison). (Drain Eye) Photo #5 Photo #6 TEST #2 Top Vent vs. No Top Vent Test (Flow Restricted) This worst case urine flow bench testing showed that suction events could be intentionally created with an artificial flow restriction in all non - top vented systems, even those that wouldn t otherwise be readily susceptible to siphons. 6

DISCUSSION: This In-vitro bench test was able to accurately simulate the clinical environment and measure pressures near the patient. Any pressure on the bladder due to the collection system will prevent optimal urine flow and can potentially cause patient discomfort events in the form of bladder fullness, urge to void, bladder distension, bladder spasm etc. In-vitro test results demonstrate that top vents prevent any sustained back pressures from reaching the bladder, thus optimizing system urine flow and patient comfort and minimizing caregiver intervention. A previous In- vivo top vent bladder study 1 found that suction lesions formed due to sustained suction events on all 53 patient bladders with non-top vented systems while none formed on all 52 bladders with top vented systems. These lesions were shown to occur in less than 20 minutes and became progressively worse over time. To confirm these McDonald study results, the following bladder cystoscope photographs of non-top vented systems were recently taken at Massachusetts General Hospital (see photos 7 & 8 below). CONCLUSIONS: The Kendall Urology R&D group has developed a solution to improve flow in a urine collection system. In-vitro bench testing showed that the new DOVER Urine Collection systems with top vents significantly reduce any sustained back pressure or suction events. The DOVER top vent is a unique state-of-the-art device designed for the patient and caregiver alike to: Cancel out both positive and negative pressures exerted on the bladder. Maximize urine flow. Improve patient comfort. Significantly decrease the need for nursing intervention. REFERENCE: 1 McDonald, H.P., Jr., Macalalad, F.V., et al., Suction lesions of the bladder prevention by top-vented-line drainage system, Am. Urol.Assoc. 1972 These photos show bladder vascular changes after less than a half hour of catheterization during a surgical urethral sling procedure. These changes most likely occur due to suction events which form at the transition point from high to low urine flow through the collection system Photo #7 Photo #8 Pre-Catheterization Post-Catheterization Photographs provided by Dr. Joseph Grocela at Massachusetts General Hospital The pre-catheterization picture is a different color because the bladder is still filled with urine. The post-catheterization picture on is right is taken when with the bladder filled with sterile water. 7

Trademark of Tyco Healthcare Group LP or its affiliate. 15 Hampshire Street Mansfield, MA 02048 1-800-962-9888 508-261-8000 www.kendallhq.com For International locations please see www.tycohealthcare.com H-6018 10M Tyco 5/2007