Abstract.

Similar documents
BestSound Technology. Compendium

Fitting Decisions and their Impact on Hearing Aid User Benefit. Mallory Maine, AuD Audiologist, GN ReSound

Insio: A new standard in custom instruments

Sonic Spotlight. SmartCompress. Advancing compression technology into the future

How to use AutoFit (IMC2) How to use AutoFit (IMC2)

Environmentally Aware Feature-Packed DSP Hearing Aid Amplifier ACOUSTIC SCENE ANALYSIS AUDIOLOGY BACKGROUND

Evidence base for hearing aid features:

Audiology Today MarApr2011

Adaptive Feedback Cancellation for the RHYTHM R3920 from ON Semiconductor

ReSound NoiseTracker II

AND9020/D. Adaptive Feedback Cancellation 3 from ON Semiconductor APPLICATION NOTE INTRODUCTION

C H A N N E L S A N D B A N D S A C T I V E N O I S E C O N T R O L 2

Sonic Spotlight. Binaural Coordination: Making the Connection

Clinical Tips for Matching Real-Ear Prescriptive Targets

Putting the focus on conversations

TOPICS IN AMPLIFICATION

HearIntelligence by HANSATON. Intelligent hearing means natural hearing.

How to select the optimum BTE fitting option

IMPROVING THE PATIENT EXPERIENCE IN NOISE: FAST-ACTING SINGLE-MICROPHONE NOISE REDUCTION

Quick Guide Binaural REM

DSL v5 in Connexx 7 Mikael Menard, Ph.D., Philippe Lantin Sivantos, 2015.

Can you hear me now? Amanda Wolfe, Au.D. Examining speech intelligibility differences between bilateral and unilateral telephone listening conditions

RECD-Measurements with Connexx 6.3 and Unity 2

Hearing Aids and Assistive Listening Devices

Hearing Solutions Catalog Winter Supplement January 2009

About Varibel. Varibel strives to improve the quality of life for everyone who comes in touch with our products.

Top 10 ideer til en god høreapparat tilpasning. Astrid Haastrup, Audiologist GN ReSound

Topics in Amplification DYNAMIC NOISE MANAGEMENT TM A WINNING TEAM

Annoyance and Hearing Aids Donald J. Schum, Ph.D. Vice President of Audiology & Professional Relations for Oticon, Inc

Verifying the Lyric Audibility Advantage

Clinical fitting guide

Audiogram+: The ReSound Proprietary Fitting Algorithm

AccuQuest Spotlight: Successful Fittings with Oasis. Fitting Range

For hearing aid noise reduction, babble is not just babble

WITH INTEGRATED SIGNAL PROCESSING

binax fit: How it s simulated in Connexx, how to verify it, and how to match-to-target the easy way

Differences in added stable gain between manufacturers, audiometric configurations, earmold styles, and frequency bands

Binaural Processing for Understanding Speech in Background Noise

An assessment of the validity of a subjective hearing aid verification procedure

IMPROVE YOUR NEXT HEARING AID EXPERIENCE WITH HEARING TRACKER. Abram Bailey, AuD Hearing Tracker, Inc President

Digital. hearing instruments have burst on the

Testing Digital Hearing Aids

Optimising Outcomes for Speech Mapping

Radius: Congratulations on your journey to improved hearing.

Manufacturers NAL-NL2 Fittings Fail Real-ear Verification

Turn up the volume on life. The powerful choice for your super power users

2/16/2012. Fitting Current Amplification Technology on Infants and Children. Preselection Issues & Procedures

OCCLUSION REDUCTION SYSTEM FOR HEARING AIDS WITH AN IMPROVED TRANSDUCER AND AN ASSOCIATED ALGORITHM

Sonic Spotlight. The Acoustic Flexibility of Sonic BTEs and minibtes: A Size, Sound and Set-up for Every Patient

The first choice for design and function.

Solutions for better hearing. audifon innovative, creative, inspired

Candidacy and Verification of Oticon Speech Rescue TM technology

INTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.

how we hear. Better understanding of hearing loss The diagram above illustrates the steps involved.

Make the world louder!

Initial-Fit Algorithm vs. Probe- Microphone Verification: Comparing Self-Perceived Benefit

Satisfaction Survey. Oticon Intiga gets it right with first-time users

How to use mycontrol App 2.0. Rebecca Herbig, AuD

The Inium custom programme

The Use of a High Frequency Emphasis Microphone for Musicians Published on Monday, 09 February :50

resoundpro.com PARTENRSHIPS Aventa 3 User Guide GUIDE FOR PROFESSIONALS

Chapter 7 CONCLUSION AND RECOMMENDATIONS

Proceedings of Meetings on Acoustics

WIDEXPRESS THE WIDEX FITTING RATIONALE FOR EVOKE MARCH 2018 ISSUE NO. 38

Industry Emphasis. Hearing Aids. Basic Design and Function. Hearing Aid Types. Hearing Aid Types. Hearing Aid Types.

How to Use Connexx 8.3 Hearing Profile

Music. listening with hearing aids

How to use mycontrol App 2.0. Rebecca Herbig, AuD

White Paper: micon Directivity and Directional Speech Enhancement

Best Practice Protocols

Psychoacoustical Models WS 2016/17

Nature has given us two ears designed to work together

Enjoy the sound of life. Intuis 2. The Intuis 2 family. A complete range for a full sound experience.

Technical Topics. Where did my gain go? Thin Tube Open Fit BTE Verification. History of Thin Tubes: Summary of presentation by C. Staples and S.

Custom instruments. Insio primax User Guide. Hearing Systems

personalization meets innov ation

Muse Wireless CROS System

Your Guide to Hearing

You regular readers of Page Ten

Effects of speaker's and listener's environments on speech intelligibili annoyance. Author(s)Kubo, Rieko; Morikawa, Daisuke; Akag

Validation Studies. How well does this work??? Speech perception (e.g., Erber & Witt 1977) Early Development... History of the DSL Method

NHS HDL(2004) 24 abcdefghijklm

Hearing Aid Education Seminar. Jill Mendez, AuD Tejas Hearing Aid Center

Enjoy the sound of life. Sirion 2. The Sirion 2 family. Discreet hearing in every situation.

Dr. Alexander Goldin Founder & CEO, Alango Technologies, Ltd. Global Device Summit 27 June 2018 / MWC Shanghai

Acoustic feedback occurs in all hearing

Course Syllabus. Office: J210 Phone: Cell: Office hours: by appointment

Group Delay or Processing Delay

Conversations on Verification Part I. Hearing Aid Fitting Errors in Oregon Ron Leavitt, Nikki Clark & Camille Jenkins

Simpler. There are enough mid-market hearing aids. So why make another one? you might ask...

Predicting Directional Hearing Aid Benefit for Individual Listeners

GET THE STORY IN DETAIL CARISTA HEARING SYSTEMS.

UvA-DARE (Digital Academic Repository) Perceptual evaluation of noise reduction in hearing aids Brons, I. Link to publication

Building Practice Success Through Speechmap Real Ear Measurements. Chris Stokes-Rees

Issues faced by people with a Sensorineural Hearing Loss

Using digital hearing aids to visualize real-life effects of signal processing

Oticon Agil. Connectivity Matters - A Whitepaper. Agil Improves ConnectLine Sound Quality

Audiologic management of adult hearing impairment

It takes two. Why it s a good idea to wear a hearing aid in both ears.

New CTA PSAP Quality Standard (Starting with Some Interesting Questions)

Transcription:

Combining Phase Cancellation, Frequency Shifting and Acoustic Fingerprint for Improved Feedback Suppression Josef Chalupper, Thomas A. Powers, Andre Steinbuss www.siemens.com Abstract Acoustic feedback is one of the most negative aspects associated with hearing instruments. In many cases, the annoyance, frustrations and embarrassment caused by feedback may even outweigh an individual s otherwise perceived benefit of amplification. Acoustic feedback also can indirectly reduce patient benefit with amplification. They may choose to use less-than-optimal gain to avoid the likelihood of feedback, only use the hearing aids for situations known to be feedback free, or in extreme cases, simply stop using the hearing instruments. Acoustic feedback even contributes to the hearing aid effect, as potential users of amplification view acoustic feedback as part of the negative stigma (Cox and Alexander, 2000). Minimizing feedback through effective feedback reduction algorithms also allows for more flexibility in selecting hearing aid style, as the tightness of the fitting is less critical. With a sophisticated automatic feedback reduction system, the occlusion effect can be eliminated and sound quality can be improved in cases where it otherwise would not have been possible. For this reason, effective feedback solutions have been the driving factor in the success of today s open-canal technology. When all these factors are combined, it is easy to understand why many experts consider automatic-adaptive feedback reduction the most beneficial development in hearing aid technology over the past decade. To review, acoustic feedback occurs when amplified sound from the receiver leaks out of the ear canal (e.g. around the earmold, through a vent, etc), is picked up by the microphone, and in turn amplified again. The route which the amplified signal travels back to the microphone is called the feedback path. The goal, therefore, is to break this feedback path. In this paper, we ll introduce a new method to control feedback, the Siemens FeedbackStopper, a feature that is now included in all Siemens BestSound technology.

1 Attempts to Reduce Feedback Feedback suppression is, and has always been, an important topic for the hearing instrument industry. Generally, two methods have been used to counteract feedback: gain reduction (notch filters), and phase cancellation. Gain reduction and notch filters, the approach used in most technology until 2004, reduce gain in the frequency region where feedback occurs. While this approach can be successful in eliminating feedback, unfortunately, it also reduces gain for target signals like speech, resulting in reduced speech intelligibility. Phase cancellation systems, on the other hand, are capable of suppressing feedback without degrading the audibility of speech, and therefore, this type of feedback reduction is the industry standard. While most currently available feedback management systems are able to account for individual ear and fitting differences, and counteract the static feedback path, the challenge lies in rapidly changing feedback paths. Even for the same person, no matter how well an earmold or in-the-ear hearing instrument fits in the canal, as the user goes about in his daily life, the feedback path changes when he talks or chews, when he leans his head back against the couch, or when he hugs a loved one. Changes in the feedback path, such as those just mentioned, occur very quickly. In order to eliminate feedback in these situations before it becomes disturbing to the user, it is essential that the feedback canceller acts within milliseconds. A potential downside, however, is that fast acting feedback cancellation systems often mistake tonal stimuli in the environment such as music for feedback, and thereby create artifacts and distortions in such acoustic situations. In summary then, a good feedback cancellation must fulfill three requirements: 1. Effective feedback suppression without affecting target signals like speech 2. Fast adaption to changing environments 3. Robustness against artifacts To review, phase cancellation systems are very effective for reducing feedback, but several different design features must be taken into account. For this reason, we have seen a constant advancement of phase cancellation systems over the past several years: 2004: First fully adaptive phase cancellation algorithm without the need of initialization. 2006: Adaptive feedback cancellation with adaptation speed control that provided a faster feedback cancellation with fewer artifacts. 1

2 2008: The 3rd generation algorithm uses Acoustic Fingerprint Technology to mark the outgoing signal. This marking helps to improve the accuracy of feedback detection so the cancellation can be conducted faster; fewer artifacts and more feedback stability. 2010: The 4 th generation of phase cancellation systems was introduced, called FeedbackStopper. FeedbackStopper: How It Works Siemens FeedbackStopper is an adaptive phase cancellation system combined with Acoustic Fingerprint Technology and transient frequency shift. The adaptive phase cancellation filter effectively cancels feedback by continuously estimating the feedback path and generating a corresponding outof-phase signal. Thus, feedback is suppressed without reducing gain for external signals like speech, music and environmental sounds. An extremely fast adaptation to changing feedback paths is achieved by using transient frequency shifting. Briefly shifting the frequency by 25 Hz breaks the feedback loop and therefore helps to suppress feedback. But even more importantly, the frequency shift helps to avoid artifacts. This is because the adaptive filter is more likely to generate artifacts if external signals are similar to the feedback signal. By shifting the frequency of the feedback signal, it becomes less similar to the external signal so that the adaptive filter can react extremely quickly without generating artifacts. This small frequency shift may be perceived by some listeners as a slight roughness in sound quality, however, the brief roughness is much less audible or annoying than the whistling of feedback. Absolute freedom from artifacts only can be achieved if the adaptation is stopped and if the frequency shifting is switched off. To maximize listening comfort, therefore, FeedbackStopper completely halts adaptation and frequency shifting whenever there is no feedback risk. To distinguish between feedback situations and non-feedback situations, FeedbackStopper employs the Siemens patented Acoustic Fingerprint Technology (AFT). Similar technologies are used in audio coding and referred to as digital watermarking. With AFT, the amplified signal that leaves the hearing instrument receiver is slightly phase modulated and this tag or fingerprint is used to identify signals that have already been amplified by the hearing aid (i.e. potential feedback). It has been demonstrated in psychoacoustic experiments that this phase modulation tag is inaudible to the human ear (Zwicker, 2010). It can, however, be identified by a technical modulation detector and used as a critical piece of information which tells the FeedbackStopper when to activate frequency shift and adaptation. 2

3 Acoustic Fingerprint detected ❶ Frequency Shift f ❷ Fast Adaptation Acoustic Fingerprint NOT detected Figure 1: How the FeedbackStopper algorithm combines phase cancellation, frequency shifting and Acoustic Fingerprint Technology. Figure 1 illustrates how the new FeedbackStopper works. Once the acoustic fingerprint is detected (i.e. feedback is likely to occur) in a particular acoustic situation, FeedbackStopper briefly shifts the entire output of the amplifier by 25 Hz. This frequency shift breaks up the feedback loop and allows adapting the phase cancellation filter very quickly usually before feedback results in audible whistling. As soon as the adaptation is finished, feedback is suppressed and thus, the modulation tag is no longer detected in the incoming signal. Now, the FeedbackStopper switches off frequency shifting and completely freezes the adaptation in order to avoid artifacts. Table 1 summarizes how these three technologies are used as part of the overall feedback reduction strategy. Requirement Effective feedback suppression without affecting wanted signals like speech Feedback Stopper Solution Adaptive phase cancellation filter Fast adaption to changing environments Transient Frequency Shift Robustness against artifacts Acoustic Fingerprint Technology Table 1: Requirements and appropriate solutions for feedback suppression with the hearing instrument Clinical Research with FeedbackStopper To examine the effectiveness of this new technology, two clinical studies were conducted. In the first, the benefit of the frequency shifting technology was evaluated. In the second study, the Siemens FeedbackStopper technology was compared to the feedback suppression systems of other major manufacturers. 3

4 Study #1: Frequency shift technology In this research, the FeedbackStopper algorithm was tested in listening situations which replicated real world conditions (see Chalupper, 2010). Twelve hearing impaired subjects with moderately downward sloping hearing loss listened to babble noise presented at 50 db SPL while moving their heads, chewing, and talking. Added stable gain provided by FeedbackStopper with and without frequency shift was measured. To determine baseline, with the Feedback stopper in the off setting, the subjects were fitted to the NAL-NL1 prescriptive method, and then overall gain was increased until feedback was present. The results (see Figure 2) showed significant (p < 0.01) improvements of 7 db for the FeedbackStopper with frequency shifting activated (setting fast ) compared to a setting with the same phase cancellation setting but without frequency shifting. The med setting also employs frequency shifting, but with a slower adaptation speed of the phase canceller. On average, compared to the original NAL-NL1 fitting, added stable gain of 24.5 db was achieved with the FeedbackStopper in fast. This clearly equals or exceeds the needed margin for variations of the feedback path in real-world listening for the majority of hearing instrument wearers. Figure 2: Added stable gain provided by FeedbackStopper for slow, med, and fast settings. Overall values are based on comparison to maximum gain that could be obtained with the FeedbackStopper in the off setting. 4

5 Study #2: FeedbackStopper Compared To Other Leading Products There are many different reports available regarding the effectiveness of automatic feedback reduction algorithms. Unfortunately, different measurement procedures often are used, and therefore it is difficult to make direct manufacturer-to-manufacturer comparisons. For this reason, it is important that independent researchers conduct unbiased benchmark research, using identical measurement procedures to evaluate all products. Such a study recently was conducted at the auditory research laboratory of Vanderbilt University, Nashville TN (Ricketts, 2010). In the initial phase of the study, all of the six world-wide leading manufacturers were requested to provide samples of their premier hearing aid; the device that had the best feedback reduction system. Each of these six products was then tested for different settings, until the feedback reduction for a given product was optimized while still not generating artifacts that were audible to listeners with normal hearing. The products were fitted to individuals with totally open ear canal configuration, to create a feedback-prone fitting. The hearing aids were programmed to the NAL-NL1 prescriptive targets for a mild-moderate downward sloping hearing loss, verified via probe-microphone measurements. The experimenter monitored the real ear gain throughout the measurement. With the feedback reduction algorithm turned off, the gain was then raised across all frequencies until feedback occurred. The feedback algorithm was then turned on, and the gain was again raised until feedback occurred. The measured real ear gain was used to obtain two key measures: added stable gain (the additional gain obtained when the feedback algorithm was activated) and the most important finding degree of feedback-free real ear insertion gain (REIG). The preliminary data reported here reflect averages obtained on the first ten ears evaluated in this study. It is important to point out, that the research protocol required each participant to talk, walk around, place their hand near his ear, etc.; more or less the activities of a typical hearing aid user. The goal was to determine the maximum gain for real world wearing conditions. The test results, therefore, might not agree with published results obtained using the KEMAR in an anechoic chamber or human subjects under less realistic conditions (e.g. without placing the hand near the ear). The probe microphone measurements indicated that some models automatically reduce gain when approaching the feedback margin. The added stable gain (ASG) was calculated for the key frequencies of 2,000, 3,000 and 4,000 Hz. The results showed a large ASG difference among the six manufacturers. For example, Siemens and Brand A had the highest mean ASG (13 and 14.5 db, respectively) whereas Brand D and Brand E had a mean ASG of only 2.3 to 3 db. 5

6 Although ASG findings are commonly used, and can be informative, these results do not necessarily identify the best feedback system from a clinical standpoint. For example, if the hearing aid is very stable with the feedback algorithm off, there is less room for improvement with it on (the gain limits will be reached), and the ASG will be smaller as a result. A more informative measure, especially related to the practical fitting of open-canal hearing aids, is the amount of feedback-free real-ear gain that is available when the ear canal is open. Siemens Figure 3: Maximum feedback-free real-ear insertion gain for six different openfitted receiver-in-canal hearing instruments. Shown in Figure 3 are the mean REIG findings for the six manufacturers. These values represent the average maximum gain that could be obtained for an open fitting with the feedback algorithm activated. There were significant differences among manufactures, with the best overall results obtained with Siemens Pure 701. Observe that there was a difference of as much as 15-20 db between the Siemens product and some of the other products. This has a major impact on defining the fitting range. Observe that for the key frequency of 3000 Hz, the Siemens device has a 7 db advantage over Brand A, its nearest competitor. A gain advantage of this magnitude can extend the fitting range by 15-20 db. 6

7 Finetuning the FeedbackStopper in Connexx There are adjustments that can be made in the fitting software to alter the feedback suppression effects. FeedbackStopper has three settings: Slow setting: Fast feedback suppression without frequency shift. This setting is optimized for maximum sound quality and should be chosen for individuals who are less prone to feedback and more disturbed by the roughness in sound quality introduced by frequency shift. Medium setting: Fast feedback suppression which features a less sensitive frequency shift activation so that shifting occurs only when absolutely necessary. This is the default setting. Fast setting: Fast feedback suppression with a more sensitive frequency shift activation so that the shift occurs more often. This setting should be used for individuals more prone to feedback and not as bothered by occasional roughness in sound quality caused by frequency shift. Figure 4: Fine-tuning options for the FeedbackStopper Since open-canal fittings are the most challenging for feedback stability, the Open Optimizer featured in Pure and Life instruments further improves the effectiveness of FeedbackStopper. This is achieved by optimizing the parameterization of the signal processing on specific properties of the acoustic feedback path of open-canal fitting. By activating the Open Optimizer, the stable gain of Pure and Life open-canal fittings can be increased by about 4 db. Hence, for fittings with closed and open domes/tips and vents larger than 2.5mm, Open Optimizer should be activated in order to achieve maximum feedback stability. FeedbackStopper How to demonstrate The FeedbackStopper can be demonstrated with the hearing instrument either in the patient s ear, or on a model ear. To begin, set the FeedbackStopper to OFF with the hearing aid at use gain (or CONNEXX Fit), and slowly approach the hearing instrument with an open hand. 7

8 Note the distance between the hand and the hearing instrument when feedback first occurs. Next, set the FeedbackStopper to the Fast setting. Note how much closer the hand can be to the hearing instrument before feedback occurs, indicating that the FeedbackStopper can effectively eliminate feedback even in the most critical situations. If you use real-ear probemicrophone measures, the before and after settings can be recorded to provide visual display for patient counseling. Summary Acoustic feedback reduction that works automatically and adaptively is one of the most beneficial algorithms offered in modern hearing aids. An effective system can significantly impact on hearing aid use, benefit and satisfaction. The new transient frequency shifting technology has been shown to provide an additional 7 db of added stable gain, making maximum added stable gain as high as 25 db. As we reviewed, independent research compared the Siemens Feedback- Stopper to the premier product from five other manufacturers, and assessed the real-ear effectiveness of the feedback reduction algorithm when the hearing aids were used in real-world condition. The results showed large variability among the different products, with the Siemens Pure 701 showing superior performance. The effectiveness of the feedback algorithm greatly influence the hearing instruments fitting range, and can impact significantly on the audibility provided by the instrument. The use of an effective feedback suppression system, therefore, ultimately influences hearing aid benefit and satisfaction. References Chalupper J. Advances in automatic feedback suppression. Paper presented at the Annual Convention of the American Academy of Audiology, San Diego, CA (April 2010) Cox, R.M., and Alexander, G.C. Expectations about hearing aids and their relationship to fitting outcome. Journal of the American Academy of Audiology, 11: 368-382 (2000). Ricketts TA. Adults with mild and moderate hearing loss: Are they really hearing aid candidates? Paper presented at the International Hearing Aid Research Conference, Lake Tahoe, CA (August 2010) Zwicker, E., Fastl, H.: Psychoacoustics: Facts & Models. 2nd Edition, Springer, Berlin/Heidelberg (2007) 8