A Guide to Safe Handling of Hazardous Materials

Similar documents
CHEMICAL GLOVE RESISTANCE GUIDE

JACKSON SAFETY*/KLEENGUARD* Gloves. G80 - G10 Gloves

EXTRA STRENGTH DISPOSABLE GLOVES

Glove Selection Guide

Chemical Compatibility Guide for: Ammex Gloves

Acids. Chemical GS HT UT UR XP HD

Cleaning gloves for all purposes. Personal protection the professional way

Vasco OP Free Sterile Surgical and Protective Gloves

Compatibility Nonwoven Oil And Universal Sorbents

B. Braun Melsungen AG confirms that Vasco Guard long gloves comply with the following standards and directives: EN , ISO , ASTM D6319

Approved IP Products, #844 Addenda I, Approved IP Products List

Vasco OP Sensitive Sterile Surgical and Protective Gloves

MedlineExamGloves. The best choice for quality protection

Vasco Nitril light Non sterile Examination and Protective Gloves

Everything you touch...we touch.

WAXIE Shield Disposable Gloves

Everything you touch...we touch.

Chemical Resistance Guide

1. Physical Resistance 2. Chemical Resistance 3. Application

Tank Armor SERIES 390. Chemical Resistance. 1, 1, 1-Trichloroethane (Trichloroethane) FC, OC. Aluminum Sulfate (49%) IS, TS, SC, FC,

Conwy & Denbighshire NHS Trust. Ymddiriedolaeth GIG Siroedd Conwy a Dinbych Conwy & Denbighshire NHS Trust

This chart is intended

Tabla de resistencia de agentes químicos

Zurn Chemical Resistance Information Flo-Thru Drainage Systems

High Performance Surface Protection. Polymersilicate Coating System. AKS Coatings GmbH

VersaFlex VT-40 Chemical Resistance Chart

SUPPORT PACK. Nitra-Touch

Flexible Reinforced Hoses from soft PVC

Bloodborne Pathogens Key Topic for 2015 Gloves The First Line of Defense

Vasco OP Underglove Sterile Surgical and Protective Gloves

Chemical Effect on Concrete Concrete Treated with Penetron. Acetic Acid to 30% Disintegrates Slowly S/E. Acetone Liquid loss by penetration N/E

Cleaning and Disinfection of Environmental Surfaces

Vasco Nitril long sterile Sterile Examination and Protective Gloves

Box X-Small Small Medium Large X-Large. Ÿ Suits Ÿ Protex Ÿ Medilex Ÿ Ansell Ÿ Surgiglove.

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

RAW Handel und Beratungs GmbH Grünstrasse 5 Phone Fax

Emergency eyewash and showers

Glove Use Considerations

ADVANCING TOWARDS A SAFER O.R.

ABSORBENTS THE EMPTEEZY GUIDE TO

GLOVE ALLERGIES AND HAND HEALTH

Vasco Nitril Soft blue Non sterile Examination and Protective Gloves

Best N-DEX Free 7705PF and 7705PFT Gloves

Glove Selection Guide

Cable Ties-Material Selection Ordering Guide

Inversiones Pamcrok, C.A located in Caracas, Capital of the Bolivarian Republic of Venezuela is a company dedicated to the Marketing and production

Vasco Nitril blue Non sterile Examination and Protective Gloves

Active Ingredient in Disinfectants & antiseptics (others)

Top Dog Product Chemical Resistance Guide (A Sampling)

Chemical Resistance of P.V.C. Matting Products

The four levels of protein structure are: primary structure, secondary structure, tertiary structure, and quaternary structure.

fication Material Interceptorr Fabric layers and 8 barrier film blue, orange and Grey. Test Results ASTM D3776 Basis Weight 325gsm >2500 Class 2

Policy Title: Clinical Asepsis Policy Policy Number :19. Effective Date: 6/10/2013 Review Date: 6/10/2016

Skin Exposure Assessment

FIXATION OF TISSUES MODULE 5.1 INTRODUCTION OBJECTIVES 5.2 AIMS OF FIXATION 5.3 PRINCIPLE OF FIXATION. Notes

Contents. 01 Welded Syringe Filter Economy Syringe Filter Sterile Syringe Filter Membrane Filter 21

Hygiene and pathogens. A pathogen is a disease-causing organism and includes agents such as: bacteria viruses fungi parasites.

1 L Disposable Plastic Bottle. 500 ML Disposable Plastic Bottle. 1 L Disposable Plastic Bag. Bottle. Bottle. Bottle. 1 L Bag. Swab or Tube.

MATERIAL SAFETY. St. Paul, Minnesota or (651) (24 hours)


4 : Abrasion resistance 1 : Cut resistance 0: Tear resistance 3 : Puncture resistance Data available upon request AQL 0.65 or EN Performance level 3

Wastewater Treatment: Reducing Salts Generated During Treatment to Promote Water Re-Use. By: David Calnan Cherokee Chemical Inc, (CCI)

TPV - TAROPRENE CHEMICAL RESISTANCE

SELECTING THE RIGHT HAND PROTECTION WHEN WORKING WITH CHEMOTHERAPY DRUGS

KEY RESIN #510LV EPOXY BINDER

Vasco Surgical Powder-free Sterile Surgical and Protective Gloves

Principles and Practices of Asepsis

The Essential KRUUSE Veterinary Glove Handbook 3 rd Edition

YOUR PERSONAL PROTECTION

EUDRAGIT E 100, EUDRAGIT E PO and

CORROSION INHIBITORS CATALOGUE

A HIGHER DEGREE OF CONFIDENCE

Guidelines for the Control of a Suspected or Confirmed Outbreak of Viral Gastroenteritis (Norovirus) in an Assisted Living Facility or Nursing Home

FOR A HIGHER DEGREE OF CONFIDENCE

ANOPORE MEMBRANE FILTERS - TECHNICAL SPECIFICATIONS

GLOVES. Getting a grip on infection control. a complete guide for every exposure level

DuPont Tyvek 500 Xpert, TYCHF5SWHXB/TYCHF5SWHXB

יחידת הבטיחות. Potential Peroxide-Forming Solvents*

GPS* Safety Summary for Sodium Hydroxide

The Mungo Foundation. Personal Protective Equipment Policy & Procedure

SAFETY DATA SHEET Clinell Spill Wipes According to Regulation (EU) No 453/2010

Defoaming Surfactants

EUDRAGIT L 100 and EUDRAGIT S 100

Occupational Hazard In Dentistry. By Dr.Lamya Al-aazwi

Chemical Handling Guide. Do your gloves pass the acid test?

Petrolatum. Stage 4, Revision 1. Petrolatum is a purified semi solid mixture of hydrocarbons obtained from petroleum.

SUBJECT: Management of Human Body Fluids/Waste (Bloodborne Pathogens)

Vinyl Lightly Powdered General Purpose Gloves

Pre Operative Care Pre-Surgical Planning

3. PRELIMINARY PHYTOCHEMICAL SCREENING

THERMALLY OXIDIZED SOYA BEAN OIL

AIMS Plastic Fittings

To standardize wound care and prevent infection in compromised patients who have a Berlin Heart Ventricular Assist Device (VAD).

OCCUPATIONAL DERMATITIS

REVISION MATERIAL SAFETY DATA SHEET

DuPont Tyvek Labo, Model CHF7

ACUSOL 820 Rheology Modifier/Stabilizer

Bloodborne Pathogens in the Workplace

Transcription:

A Guide to Safe Handling of Hazardous Materials

Chemical Resistance Guide Methodology Permeation Permeation is a process by which a chemical can pass through a protective film without going through pinholes, pores or other visible openings. Individual molecules of the chemical enter the film, and squirm through by passing between the molecules of the glove compound or film. In many cases the permeated material may appear unchanged to the human eye. Chemical permeation can best be described by comparing it to what happens to the air in a balloon after several hours. Although there are no holes or defects, and the balloon is tightly sealed, the air gradually passes through DEGRADATION Degradation is a reduction in one or more physical properties of a glove material due to contact with a chemical. Certain glove materials may become hard, stiff, or brittle, or they may grow softer, weaker, and swell to several times their original size. If a chemical has a significant impact on the physical properties of a glove material, its permeation resistance is quickly impaired. For this reason, glove/chemical combinations rated Poor or Not Recommended in degradation testing were not tested for permeation resistance. Please note, however, that permeation and degradation do not always correlate. (permeates) its walls and escapes. This simple example uses gas permeation, but the principle is the same with liquids or chemicals. Latex Nitrile Neoprene POLYISOPRENE General Purpose

CHEMICAL RESISTANCE GUIDE Acetone Ammonium Hydroxide, Conc. Detergents Diguanide N, N Didecyl Dimethyl Ammonium Chloride Phenol, 90% Phenolic Disinfectant (Typical) Sodium Hypochlorite, (< 15%) (Bleach - Saturated Aqueous Solution) CHG, 4% (Chlorhexidine Gluconate) Iodine In (Betadine) Alcohol Solution Iodine In (Betadine) Antiseptic Solution Iodine In (Betadine) Surgical Scrub Povidone Iodine (PVPI) Triclosan (Irgasan DP 300) LATEX 1 nitrile 2 neoprene 3 POLYISOPRENE 4 Cleaning Agents - 'Quat' (Quaternary) Compounds Limited Not Recommended Limited Limited Good Preferred Good Good Limited Not Recommended Good Limited Fair Fair Good Fair Hand Sanitizers/Cleaners Limited L e v epreferred l o Fair f B alimited r r Preferred Good Good Good Fair Fair Fair Fair Ethyl Alcohol (Ethanol) Isopropyl Alcohol (Isopropanol) (Isopropanol, 70% - Rubbing Alcohol) Methanol (Alcohol Solvent) Alcohol(s) Limited Preferred Fair Limited Limited Good Good Limited Limited Preferred Good Limited Blood / Body Fluid Virus (Pass/Fail Rating to Virus Test F1671) Body/Blood Fluids/Test Virus Pass Pass Pass Pass Cold Sterilants - Instruments Cidex OPA (Ortho-Phthalaldehyde) Solution Glutaraldehyde, 2% - 25% Hydrogen Peroxide, 30% Peracetic Acid, 35% (Organic Peroxide Type E Liquid) Good Good Not Rated Good Limited Limited Preferred Limited A Pure methyl methacrylate (bone cement) rapidly degrades and permeates all types of disposable gloves. If hospital workers must handle cement ingredients that contain high concentrations of methyl methacrylate, Ansell recommends that double gloves are worn and that the outer gloves be replaced very promptly in case of accidental contact. When a bone cement is prepared for use, it is generally prepared in a container using a spatula to mix and avoiding contact with the gloved hand. When mixed the methyl methacrylate begins to polymerize rapidly, thereby increasing in molecular weight and losing the ability to permeate through gloves. When this polymerization has progressed far enough, orthopedic-grade latex gloves, or double gloved latex, neoprene or polyisoprene gloves can be used safely. The time to progressed far enough will vary with the temperature, the details of the cement formulation, and other factors. There is no practical way to test for this property. Operating room personnel should therefore be alert for possible skin symptoms. Any medical-grade utility glove may be used for clean-up afterwards. The methyl methacrylate in any unused bone cement will be fully converted to a safe, solid high polymer by then.

GENERAL PURPOSE GLOVES 5 Use Perry General Purpose Glove Use Perry General Purpose Glove. Minimize Contact Chloroform (Anesthetic) Ethyl Ether Methyl Methacrylate Bone Cement - (Mixed & Not Mixed) Methylene Blue Mineral Oil Plaster of Paris LATEX 1 NITRILE 2 NEOPRENE 3 POLYISOPRENE Other Common Hospital/OR Products Not Recommended Not Recommended Not Recommended Not Recommend Not Recommended Fair Limited Not Recommend See Below A See Below A See Below A See Below A Not Recommended Preferred Good Not Recommend Lab Products iuse Any e Of 3 r General Purpose P Styles r o t e c t i o n sol-vex Preferred Pass Acetic Acid (Glacial) Cationic Detergent Caustic Soda Citric Acid, 10% Dimethyl Sulfoxide (DMSO) Formaldehyde (Formalin) Formol, 10% Hydrochloric Acid, 10% Lactic Acid Mercury Methylated Spirits Nitric Acid, 10% Oleic Acid Phosphoric Acid, 35% Picric Acid (Water Solution) Potassium Hydroxide Sodium Chloride (Saline Solution) Sodium Hydroxide, 50% Limited Preferred Fair Limited Not Rated Preferred Not Rated Not Rated Limited Preferred Fair Limited Fair Preferred Fair Fair Perry General Purpose Glove Preferred Sodium Hypochlorite (Javex) Sodium Nitrate Solutions Sulfuric Acid, <30% Toluene Triethanolamine, 85% Urea Xylene Fair Fair Good Fair Not Recommended Limited Not Recommended Not Recommende Fair Good Good Fair Not Recommended Limited Not Recommended Not Recommende LATEX NITRILE NEOPRENE POLYISOPRENE 1 Surgical - Encore Family, No Powder, Neutralon, Micro-Touch, Perry Orthopaedic, Sensi-Touch, The Original Perry Style 42 Exam - Micro-Touch Plus, Micro-Touch NextStep, Micro-Touch E.P. Gloves, Micro-Touch Plus Sterile Singles, Micro-Touch Powder 2 Surgical - None Exam - Micro-Touch NitraFree TM, Micro-Touch Nitrile, Micro-Touch Smooth Nitrile, Micro-Touch Nitrile E.P., Micro-Touch NitraTex Sterile Pairs and Singles 3 Surgical - Derma Prene Ultra Exam - Micro-Touch Affinity 4 Surgical - Derma Prene IsoTouch, Derma Prene IsoTouch Micro Exam - None

Key To De g r a d at i o n Rat i n g ed ed ed 4 GENERAL PURPOSE GLOVES 5 no General Purpose Gloves Can Be Recommended Alone. Use 2-100 Barrier Gloves For Handling Chloroform. See Below A Preferred Protection little or no degradation or permeation. Good Protection minimal degradation; permeation should not occur in less than 30 minutes. Fair Protection degradation may occur, and/or some chemical is likely to permeate the glove in less than 30 minutes. Limited Protection degradation is likely to occur; some chemical will probably permeate or penetrate the glove in less than 5 minutes. Not Recommended severe degradation and permeation is likely. Not Rated insufficient data is available to make a recommendation. d d. Minimize Contact. General Purpose GLOVES 5 Other - Perry General Purpose Gloves, Housekeeping Gloves, Sol-Vex When reviewing this guide remember that barrier ratings are based upon Ansell's knowledge and expertise of materials and their performance in a controlled setting. Actual workplace conditions usually dictate a combination of performance capabilities; these variables cannot be duplicated in a controlled environment. A product's resistance to cuts, punctures, and abrasion must also be taken into account as a critical usage factor. A glove with excellent permeation resistance may not be adequate if it tears or punctures easily. Always factor in the physical performance requirements of the job or application when selecting a glove barrier. Barrier ratings indicated are intended to guide and inform healthcare personnel, safety specialists and other qualified professionals involved in ensuring safety in the healthcare environment. Because the conditions of ultimate use are beyond our control, and because we cannot run permeation tests in all possible work environments and across all combinations or chemical solutions, this guide is solely advisory. The suitability of the product for a specific job must be determined based upon testing by the purchaser. Ansell believes this information is the best currently available; it is subject to revision as additional knowledge and experience are gained. Anyone intending to use the suggestions contained in this publication should first verify that the glove selected is suitable for the intended use and meets all appropriate health standards. The suggestions in this guide are not comprehensive and Ansell disclaims any implied warranties, including merchantability and fitness for particular purpose for use of its gloves with any particular chemical or fluid. Upon written request, Ansell will be happy to provide a sample to aid you in making your own selection to meet your own individual safety requirements. Vinyl is not represented in the above chart because Ansell does not recommend for use with chemicals or bodily fluids. For more information about our complete Medical Glove line, call toll-free: (800) 952-9916

Ansell Healthcare Products LLC 200 Schulz Drive Red Bank, NJ 07701 U.S.A. Phone: (800) 952-9916 (U.S.A. only) www.ansellhealthcare.com 50 BR180 08/09