Zenith. Total Ankle Replacement Surgical technique

Similar documents
Zenith. Total Ankle Replacement Surgical technique

Uniglide. Unicompartmental Knee Replacement Mk III surgical technique

Revolution. Unicompartmental Knee System

Zimmer Trabecular Metal Ankle Interpositional Spacer and Trabecular Metal Ankle Fusion Spacer

OPERATIVE TECHNIQUE SKS Total Knee Replacement

Triathlon Knee System

Trinity. Advanced Bearing Acetabular System Surgical technique

Cementless Tapered Femoral Stem Surgical technique

31861_ _Cover 3/18/08 0:03 Page 2 S U R G I C A L T E C H N I Q U E Total Ankle System

BOX Total Ankle Replacement. Operative Technique. Balanced Natural Movement

MetaFix. Cementless Total Hip Replacement Surgical technique

TOTAL KNEE ARTHROPLASTY SYSTEM

ANATOMIC SURGICAL TECHNIQUE. 5 in 1. Conventional instrumentation 07/11/2013

Total Knee Original System Primary Surgical Technique

TRK REVISION KNEE Surgical Technique

Triathlon TS Knee System. Surgical Protocol

Extramedullary Tibial Preparation

QUICK REFERENCE GUIDE. MiniRail System. Part B: Foot Applications. By Dr. B. Magnan, Dr. E. Rodriguez and Dr. G. Vito ALWAYS INNOVATING

Integra. Cadence Total Ankle System SURGICAL TECHNIQUE

LCP Anterior Ankle Arthrodesis Plates. Part of the Synthes Locking Compression Plate (LCP) System.

AGC Total Knee System. Concise Surgical Technique Featuring EquiFlex Instrumentation

Zimmer NexGen Trabecular Metal Tibial Tray

Surgical Technique Guide

Unicondylar Surgical Technique

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD

UvA-DARE (Digital Academic Repository) Treatment of osteochondral defects of the talus van Bergen, C.J.A. Link to publication

FOREWORD PRESERVATION UNICOMPARTMENTAL KNEE SYSTEM

U2 PSA. Revision Knee. Surgical Protocol

INFINITY. Total Ankle System TIBIAL SPACER GUIDE SURGICAL TECHNIQUE

Locking Ankle Plating System. Surgical Technique

Uniglide. Unicompartmental Knee Replacement Mk III surgical technique. The mobile bearing is not commercially available in the USA

LAMINA SPREADER SURGICAL TECHNIQUE

ClassiQ. Scorpio. Anterior Referencing Surgical Protocol. Anterior Referencing. For use with Scorpio ClassiQ Instrument System

MiniRail System. Part B: Foot Applications. By Dr. B. Magnan, Dr. E. Rodriguez and Dr. G. Vito

Bone Conserving Hip Replacement Surgical technique

TRIAL COMPONENTS SURGICAL TECHNIQUE REAMING THE TIBIAL AND FEMORAL INTRAMEDULLARY CANAL

SIGMA High Performance Partial Knee. Unicondylar. Surgical Technique

Triathlon Knee System. Universal Baseplate Surgical Protocol

BIOTECH FUTURE KNEE Minimal Invasive (and classic) Surgical Technique

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME

INFINITY. Total Ankle System SURGICAL TECHNIQUE

Surgical Technique. Ankle Plating System

Triathlon Knee System Universal Baseplate Surgical Protocol

Uniglide. Unicompartmental Knee Replacement Mk III surgical technique

FLK167 02/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel Fax:

Cementless Tapered Femoral Stem Surgical technique

U2 KNEE SYSTEM. High Flexion Engineered

Surgical technique MkII instrumentation

Tibial & Femoral Opening Wedge Osteotomy System. Surgical Technique

The information contained in this document is intended for healthcare professionals only.

Opening Wedge Osteotomy

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

MIS Cemented Tibial Component

Distal Cut First Femoral Preparation

Knee. Surgical Protocol

Intramedullary Tibial Preparation

The Flower Medial Column Fusion Plate

total ankle system Surgical Technique

TIBIAXYS ANKLE FUSION

1. Pre-Operative Planning Skin Incision and Arthrotomy

Pre-Operative Planning. Positioning of the Patient

SCORE Revision. Revision Total Knee Arthroplasty Cemented. Surgical Technique With Conventional Instrumentation Primary cases

Pre-Operative Navigation Guides SURGICAL TECHNIQUE

PEDUS-L. Locking Plantar Lapidus Plate

Triathlon with Single-Use Instrumentation Optimize Your TKA Experience. Posterior Referencing Surgical Protocol

Merete PlantarMAX Lapidus Plate Surgical Technique. Description of Plate

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

Surgical Technique. VISIONAIRE FastPak Instruments for the LEGION Total Knee System

TaperFit. Cemented Total Hip Replacement Surgical technique

NATURAL MOTION TECHNOLOGY SURGICAL TECHNIQUE. EMPOWR 3D Knee. EMPOWR PS Knee

Lesser MPJ Hemi Implant

Dual Mobility System Surgical technique

Dual Mobility System Evaluation surgical technique

MRH Knee System Modular Peg Baseplate Surgical Protocol

KneeAlign System Surgical Technique Guide

Profix. Total Knee System. As described by

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

Lateral TTC Plate SURGICAL TECHNIQUE

Arthrex Open Wedge Osteotomy Technique Designed in conjunction with:

NexGen LPS Fixed Bearing Knee. Surgical Technique

FACTS 1. Most need only Gastro aponeurotic release [in positive Silverskiold test]

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

NexGen Cruciate Retaining (CR) and Revision Instrumentation. Surgical Technique

REVISION KNEE PROSTHESIS ROTARY PIVOT TOTAL KNEE REPLACEMENT. w w w. a s t o n - m e d i c a l. c o m

Fibula Rod System. Lateral Malleolus Fracture Indications:

What Happens to the Paediatric Flat Foot? Peter J Briggs Freeman Hospital Newcastle upon Tyne

S U R G I C A L T E C H N I Q U E David A. McQueen, MD Return to Menu

Knee. Surgical Protocol

The ACL-PCL Substituting Knee. BioFoam Tibial Bases. Surgical Technique For Cementless Tibial Fixation

INTUITION INSTRUMENTS SURGICAL TECHNIQUE

Surgical Technique Final Trial Reduction and Component Implantation of

Surgical Technique. VISIONAIRE Disposable Instruments for the LEGION Total Knee System

Zimmer Unicompartmental High Flex Knee. Spacer Block Surgical Technique

POSTERIOR REFERENCE NEXGEN COMPLETE KNEE SOLUTION. Multi-Reference 4-in-1 Femoral Instrumentation Posterior Reference Surgical Technique

NEXGEN COMPLETE KNEE SOLUTION S A. Tibial Stem Extension & Augmentation Surgical. ATechnique

ANTERIOR REFERENCE NEXGEN COMPLETE KNEE SOLUTION. Multi-Reference 4-in-1 Femoral Instrumentation Anterior Reference Surgical Technique

Triathlon Tritanium. Surgical Protocol. with Triathlon Cementless Beaded PA Femoral Component

Zimmer Unicompartmental High Flex Knee. Intramedullary, Spacer Block Option and Extramedullary Minimally Invasive Surgical Techniques

INTUITION INSTRUMENTS SURGICAL TECHNIQUE

SURGICAL TECHNIQUE GUIDE

Transcription:

Total Ankle Replacement Surgical technique

Contents Operative summary 4 Pre-operative planning and templating 6 Patient positioning 6 Exposure 6 Saw blades 7 Joint line definition 7 Tibial alignment jig 8 Tibial cut 8 Talar cut 9 Malleolar cut 9 Tibial sizing 10 Tibial window preparation 10 Tibial window removal 11 Tibial trial 11 Talus sizing and centring 12 Anterior talus preparation 12 Talar drill guide 13 Posterior cut 13 Talus trial 14 Mobile insert selection 14 Final implants 15 Wound closure 15 Post-operative care 15 Compatibility chart 16 Ordering information 17 Instrumentation 18 2

Technology Reproducibility Stability Simplification through innovation 3

Operative summary a. Joint line definition b. Tibial alignment jig c. Tibial cut d. Talar cut e. Malleolar cut f. Tibial sizing g. Tibial window preparation h. Tibial window removal 4

i. Tibial trial j. Talus sizing and centring k. Anterior talus preparation l. Talar drill guide m. Posterior cut n. Talus trial o. Mobile insert selection p. Final implants 5

Zenith Ankle System Description: Ti and CoCr Talus Components Pack No. Sheet 1 of 1 MAGNIFICATION: 115% (1.15:1) 500.1001 - Size 1 Ti 500.1011 - Size 1 CoCr 500.1002 - Size 2 Ti 500.1012 - Size 2 CoCr 100 90 80 70 60 50 40 30 20 10 0 Template No: 500.9090 REV: 03 ECR: 9234 DATE: 18/01/2010 500.1003 - Size 3 Ti 500.1013 - Size 3 CoCr 500.1004 - Size 4 Ti 500.1014 - Size 4 CoCr FRM303 Rev: Original ECR: 5892 DATE: 19/09/05 Pre-operative planning and templating It is recommended that patient X-rays should be studied pre-operatively to gauge any potential difficulties and to plan for them accordingly. X-rays should include accurate anterior-posterior (A-P) and lateral standing views of the complete foot and ankle of both feet would be useful. Templating can be achieved using X-rays or digital imaging. Patient positioning The patient is placed in a supine position, with a pad under the ipsilateral buttock, to prevent uncontrolled external rotation of the foot. The foot and knee should be free for rotation and alignment. A tourniquet should be used in most cases. The patient should be draped with the knee exposed to allow alignment. Exposure The surgical exposure is in line with current practice for total ankle replacement. The recommended approach is through an anterior incision over the joint line in most cases. The incision should be approximately 10-15cm long and extend proximally to allow adequate fixation for the tibial jig. The incision may be routed laterally or medially, to accommodate a previous A-L or A-M approach. After the fascia has been incised in a longitudinal fashion, the incision is deepened between the tendon of the tibialis anteriomediola, and the extensor hallucis tendons laterally. The neurovascular bundle is protected by reflecting it laterally with the extensor hallucis longus (EHL) tendon. A complete anterior capsulectomy is performed to provide access to the ankle joint line. 6

It is important for soft tissue balancing to be considered at this stage. Any required ligament soft tissue releases should be made to ensure that the talus can be brought into neutral alignment in this position. It should be possible for the position of the foot to be determined. The calcaneum should be in neutral to 7º of valgus. The forefoot should be neutral so that all the metatarsal heads are lying at the same level. Note: Self-retaining retractors should be used with great care during total ankle replacement surgery and where possible should not be used at all. This is a precautionary measure against pressure necrosis which can be caused by using a self-retaining retractor in the neutral position and not removing it prior to plantar-flexion. Saw blades Saw blades of the following dimensions are recommended for use with the Zenith instruments. Oscillating saw blade: 1.27mm thick with non-offset teeth, 60-90mm length and 13-15mm width. Reciprocating saw blade: 0.65mm thick with max. cut thickness 1mm. Single sided blade 40-60mm length. These specifications have been determined by the instrumentation and allow defined accurate cuts. Note: The saw blades provided with the system may not be compatible with the power tools being used. This should be checked prior to use. Step 1. Joint line definition Having checked the alignment of the joint and released soft tissues appropriately, the level of the joint line should be determined. It is important for any osteophytes to be removed from the ankle joint line in order to provide adequate visualisation and definition of the joint line. All osteophytes impinging medially and laterally should be removed. The 2mm spacer is inserted into the joint gap so that it is held between the tibia and talus. A thicker 3mm or 4mm spacer can be used in cases of bone loss and joint deformity. 7

Step 2. Tibial alignment jig The two parts of the tibial alignment jig and the tibialtalar block are assembled. The shaft of the jig is aligned parallel to the longitudinal axis of the tibia and proximally aligned with the tibial tuberosity. The tibial-talar block locates over the spacer using the dedicated slot. The proximal aspect is adjusted to the correct length and then secured below the knee with a silicone strap. A-P positioning of the jig is adjusted by loosening the screw on the fixing block. Once the jig has been adjusted the screw is tightened. If required a standard 3.5mm hex driver may be used. The M-L position of the jig can also be adjusted. This is done by sliding the fixing block medially or laterally. The medial end of the tibial cut should be aligned to the lateral edge of the medial malleolus. Note: Once the alignment of the jig is satisfactory the proximal pins are fixed to maintain its position. In most cases the foot is then brought into a 5 equinus position. Care must be taken to recognise a dorsiflexed or plantiflexed position of the talus on the pre-op lateral X-ray. If present, the foot needs to be positioned carefully to place the talus such that the superior cut is undertaken to take this into account. Step 3. Tibial cut The tibial-talar block provides three tibial cutting options. The slots are 3mm apart allowing a standard cut and +/- 3mm cuts, depending on the condition of the tibia and the amount of bone to be resected. The medial hole is drilled through both cortices first to dissipate any stresses thus protecting the medial malleolus. Care must be taken to protect the lateral malleolus which is often slightly posterior. 8

An oscillating blade is then used to make the tibial cut. Care must be taken to prevent notching of the malleoli. This can be achieved by slightly externally rotating the cut on the medial side and medially rotating on the lateral side. Step 4. Talar cut The most distal slot on the tibial-talar block is used to make the talar cut. An oscillating saw is used. Note: Ensure that the foot is not moved from the pre-ordained (5 equinus) position in between tibial and talus cuts. The cuts must be parallel to each other when the foot is in neutral for accurate implant positioning. Step 5. Malleolar cut The tibial-talar block is removed from the jig. The tibial alignment jig should remain in place for later preparation. A vertical cut is made using a reciprocating saw in a straight line starting at the tibial distal face and ending at the medial hole that was made anteriorly. The distal tip of the cutting blade should be marginally angled laterally in the sagittal plane to help protect the tibia posterior. In order to remove the resected bone it may be necessary to extend the horizontal tibial cut laterally. Extra care must be taken to ensure that the fibula is not notched. 9

By undertaking the tibial and talar cuts consecutively it is easier to remove the posterior part of the talus, providing an optimal work space. Use of a laminar spreader facilitates this. If spreaders are used care must be taken to prevent malleolar fracture due to distraction. Step 6. Tibial sizing The tibial sizing instrument is positioned such that the posterior lip hooks onto the posterior tibia. The correct size is read off the scale. Note: If the size indicated falls between two sizes then the tibia should be prepared for the smaller size and then up-sized if necessary. Check to see if the sagittal cut is correctly positioned medially to ensure correct sizing and that the tibial stem position is central to the tibia in the frontal plane. Step 7. Tibial window preparation The tibial window is prepared using the selected tibial window cutting block. This block is chosen from a range of six blocks based on the following criteria: 1. The thickness of the initial distal tibia cut. If a standard cut is made then the standard blocks should be used; if a -3mm cut is made then the -3mm block should be used; if a +3mm cut is made than the +3mm block should be used. 2. The size is measured by the tibial sizer in the A-P plane. This defines the stem of the implant. The blocks are marked for use with sizes 1/2 and sizes 3/4. 10

The correct block is located onto the jig and the 3.2mm drill is used to prepare the proximal radius of the tibial window. Note: A reciprocating saw is used to cut both sides of the tibial window. It is important to use the correct length of sawblade to prevent cutting bicortically. Both the block and the jig can be removed after this stage. Step 8. Tibial window removal The tibial window is removed by using the curved osteotome as a punch. Tapping the proximal end of the prepared tibial window allows the bone to be removed in one piece. It is important that this window of bone is removed and stored carefully as it will be repositioned at the end of the procedure. The tibial window is then deepened such that the stem will be in the mid-point of the tibia in both planes. Step 9. Tibial trial The tibial trial is assembled onto the handle and inserted into the tibia using a tilt and lift action. Note: Care must be taken when inserting these trials. They should not be rotated or have pressure exerted on them to avoid fracture of the medial or lateral malleolus. The tibial trial should rest on the anterior cortex of the tibia. If the trial does not fit as expected, then a larger trial can be used and excess bone can be removed until the trial fits in place. The trial impactor can be used to ensure seating of the implant. In general, down-sizing should be avoided, however up-sizing can be achieved by using a larger tibial window cutting block (following step 7). 11

Step 10. Talus sizing and centring It is important to ensure the talus component sits centrally beneath the tibia in order to restore the natural biomechanics of the ankle. Each of the talus sizers are trialled on the flat talus cut made in step 4 of the procedure. The most appropriate size is the one that fits closest to the A-P and M-L planes and also locates easily beneath the tibial window. The feeler is moved across the posterior radius of the talus sizer to confirm sizing positioning and to check for posterior osteophytes. 12 The size selected should not overhang in A-P or M-L planes. If this does happen a smaller sizer should be selected. Once the correct talus sizer has been chosen, a pin is located through the central pin hole. The talus sizer is then removed leaving the pin in place. This pin marks the central location of the talus and hence the centre of rotation of the talus. Occasional difficulty can occur with removal of the sizer. Under these circumstances the pin can be temporarily removed and then carefully replaced. Note: The line across the talar sizer reflects the central point in the coronal plane. Step 11. Anterior talus preparation The anterior talus guide locates around the pin in the talus to ensure that the guide sits in the correct A-P position. Alignment with the second metatarsal is performed using the guide rod which locates at the base of the guide. This gives a guide to rotation of the talar component around a longitudinal axis. The talus guide is fixed in place using two driven pins through the pin holes. The correct reamer tool is chosen depending on the previously selected talus sizer. Each reamer directly corresponds to the four talus sizes to ensure the correct amount of bone is resected from each face depending on the size chosen. Note: To ensure that all talar cuts are precise, the guide must rest fully against the pin inferiorly and must remain flat on the superior talar cut thoughout.

The reamer is inserted through the introduction hole and is moved around within the guide until the anterior face has been fully resected. The guide block pin is then removed revealing the two, flat prepared surfaces of the talus, one anteriorly and one superiorly. Step 12. Talar drill guide The talar guide is placed against the prepared anterior/ superior talus. The M-L position of the peg hole is determined by aligning the pin hole directly beneath the tibal window (this pin is separate to step 11). The block is then pinned in place. The peg holes are drilled by using the short 4.5mm drill through the anterior guide holes in the block as shown. After the first drill hole, a peg should be inserted for stabilisation prior to drilling the second hole. Step 13. Posterior cut The appropriate posterior cutting block is placed against the anterior/superior talus with the pins locating into the holes. An oscillating saw is used in the slot to make the posterior cut. Note: Care must be taken not to take the cut too far and damage the posterior soft tissue. 13

Step 14. Talus trial The correct talus size (as defined by the talus sizer) should be trialled to ensure that the chosen implant is the best fit. Any further bone removal should be carried out at this stage to ensure that the trial implant fits perfectly. The talar impactor can be used to ensure that the trial is fully seated in direct line with the pegs. The tibial trial is then re-introduced and fully seated. 14 Step 15. Mobile insert selection The mobile insert trial must match the size of the talus (see compatibility chart on page 16). The thickness of the mobile insert is defined by the condition of the ankle in relation to the soft tissue and ligaments, ensuring joint stability. The trial is inserted in between the trial tibia and talus. Varus/valgus tests are performed to confirm that the mobile insert and the talus remain in full contact medially and laterally. The mobile bearing must slide on the tibial component in the coronal plane. During these checks, the joint surfaces must remain in contact. Any gaps or tilting of the insert indicate instability and must be remedied by the insertion of a thicker bearing and if necessary ligament balancing procedures including lateral ligament reconstruction. With the trials in place, the ankle joint must have a good range of movement. Plantar-flexion should be up to 45 and dorsi-flexion should be up to 20. If dorsi-flexion is found to be insufficient or if there is an equinus deformity, it is necessary to check that no residual impingement is present in the gutters preventing dorsi-flexion, also that the posterior capsule is not tight. If these two issues have been dealt with, a percutaneous tendo-achilles lengthening may be required. This will preserve the correct ligament tension and give a satisfactory range of movement into dorsiflexion. Do not insert a thinner mobile bearing, as this will cause instability. Do not insert a thicker mobile bearing as this will cause joint stiffness and pain.

Step 16. Final implants The final implants are placed into position and impacted until fully seated. The bone wedge is replaced in the window of the tibia, grafting it in place, if required, with small pieces of cancellous bone. Step 17. Wound closure The wound should be closed in layers with particular care taken to close the retinaculum over the tendons. Step 18. Post-operative care Patients should be mobilised initially non-weight bearing in a cast below the knee for two weeks. Once the wound is healed and providing that there are no complications, the patient can be mobilised partial weight bearing in a removable cast for a further four weeks, at which point radiographs should be taken. Following satisfactory radiographs, the patient should go through a course of physiotherapy. 15

Compatibility chart Size 1 Size 2 Size 3 Size 4 The tibial size is selected before the talus and mobile insert. Use of the tibial sizer and trial tibial component ensures that the correct sized prostheses are chosen. The talus is sized independently of the tibia and the correct size is based on intra-operative talus sizing instruments. The previously selected talus determines the size of the mobile insert as it conforms to the deep sulcus on the talus bearing surface. The thickness of the mobile insert can vary depending on the original condition of the ankle as well as the ligaments and the soft tissue surrounding it. 5, 6, 7, 8, 10, 12mm 5, 6, 7, 8, 10, 12mm 5, 6, 7, 8, 10, 12mm 5, 6, 7, 8, 10, 12mm Size 1 Size 2 Size 3 Size 4 16

Ordering information Tibia component (Titanium) 503.1001 Size 1 Cementless 503.1002 Size 2 Cementless 503.1003 Size 3 Cementless 503.1004 Size 4 Cementless Talus component (Titanium) 500.1001 Size 1 Cementless 500.1002 Size 2 Cementless 500.1003 Size 3 Cementless 500.1004 Size 4 Cementless Tibia component (Cobalt Chrome) 503.1011 Size 1 Cementless 503.1012 Size 2 Cementless 503.1013 Size 3 Cementless 503.1014 Size 4 Cementless Talus component (Cobalt Chrome) 500.1011 Size 1 Cementless 500.1012 Size 2 Cementless 500.1013 Size 3 Cementless 500.1014 Size 4 Cementless Bearing UHMWPE 506.1051 Size 1 x 5mm 506.1052 Size 2 x 5mm 506.1053 Size 3 x 5mm 506.1054 Size 4 x 5mm 506.1061 Size 1 x 6mm 506.1062 Size 2 x 6mm 506.1063 Size 3 x 6mm 506.1064 Size 4 x 6mm 506.1071 Size 1 x 7mm 506.1072 Size 2 x 7mm 506.1073 Size 3 x 7mm 506.1074 Size 4 x 7mm 506.1081 Size 1 x 8mm 506.1082 Size 2 x 8mm 506.1083 Size 3 x 8mm 506.1084 Size 4 x 8mm 506.1101 Size 1 x 10mm 506.1102 Size 2 x 10mm 506.1103 Size 3 x 10mm 506.1104 Size 4 x 10mm 506.1121 Size 1 x 12mm 506.1122 Size 2 x 12mm 506.1123 Size 3 x 12mm 506.1124 Size 4 x 12mm 17

Instrumentation Tray 1 500.9002 2mm spacer 500.9003 3mm spacer 500.9004 4mm spacer 503.9000 EM jig 500.9001 Tibia/talar cutting block 503.9016 Tibia sizer 503.9120 Tibia keel cutting block - size 1 / 2 503.9121 Tibia keel cutting block - size 1 / 2 - +3 503.9122 Tibia keel cutting block - size 1 / 2 - -3 503.9340 Tibia keel cutting block - size 3 / 4 503.9341 Tibia keel cutting block - size 3 / 4 - +3 503.9342 Tibia keel cutting block - size 3 / 4 - -3 503.9012 Curved osteotome 500.9005 Anterior talar cutting jig 500.9014 Anterior talar cutting jig alignment rod 500.9105 Talar sizer + centre guide size 1 500.9205 Talar sizer + centre guide size 2 500.9305 Talar sizer + centre guide size 3 500.9405 Talar sizer + centre guide size 4 500.9106 Anterior talar cutter size 1 500.9206 Anterior talar cutter size 2 500.9306 Anterior talar cutter size 3 500.9405 Anterior talar cutter size 4 500.9020 Posterior talus feeler 500.9100 Posterior talar cutting block - size 1 500.9200 Posterior talar cutting block - size 2 500.9300 Posterior talar cutting block - size 3 500.9400 Posterior talar cutting block - size 4 500.9017 Posterior talar cutting block handle 500.9021 Talar drill guide 503.9103 3.2mm drill 500.9104 4.5mm stopped drill 500.9019 Pin adaptor 291.608 Pin set box (with pins inside) 650.0010 Pin puller 18

Tray 2 500.9010 Talar trial extractor 500.9102 Talar trial - size 1 500.9202 Talar trial - size 2 500.9302 Talar trial - size 3 500.9402 Talar trial - size 4 503.9101 Tibia trial - size 1 503.9201 Tibia trial - size 2 503.9301 Tibia trial - size 3 503.9401 Tibia trial - size 4 503.9015 Tibia/insert trial handle 506.9105 Trial insert - size 1 / 5mm 506.9106 Trial insert - size 1 / 6mm 506.9107 Trial insert - size 1 / 7mm 506.9108 Trial insert - size 1 / 8mm 506.9110 Trial insert - size 1 / 10mm 506.9112 Trial insert - size 1 / 12mm 506.9205 Trial insert - size 2 / 5mm 506.9206 Trial insert - size 2 / 6mm 506.9207 Trial insert - size 2 / 7mm 506.9208 Trial insert - size 2 / 8mm 506.9210 Trial insert - size 2 / 10mm 506.9212 Trial insert - size 2 / 12mm 506.9305 Trial insert - size 3 / 5mm 506.9306 Trial insert - size 3 / 6mm 506.9307 Trial insert - size 3 / 7mm 506.9308 Trial insert - size 3 / 8mm 506.9310 Trial insert - size 3 / 10mm 506.9312 Trial insert - size 3 / 12mm 506.9405 Trial insert - size 4 / 5mm 506.9406 Trial insert - size 4 / 6mm 506.9407 Trial insert - size 4 / 7mm 506.9408 Trial insert - size 4 / 8mm 506.9410 Trial insert - size 4 / 10mm 506.9412 Trial insert - size 4 / 12mm 500.9009 Talar impactor 503.9008 Tibia impactor 19

The Corinium Centre Cirencester, GL7 1YJ t: +44 (0)1285 659 866 f: +44 (0)1285 658 960 e: info@coringroup.com www.coringroup.com Printed on 9lives 80 which contains 80% total recycled fibre and is produced at a mill which holds the ISO 14001 for Environmental Management Systems. The pulp is bleached using Elemental Chlorine Free processes. 2010 Corin P No I799 Rev4 04/2010 ECR 10192