This is a provisional PDF comprising this cover note and the manuscript as it was upon acceptance for publication.

Similar documents
Introduction. Case ABSTRACT. KEY WORDS: Coronary vessel anomalies; Percutaneous transluminal coronary angioplasty; Tomography, X-ray computed.

An Expedient and Versatile Catheter for Primary STEMI Transradial Catheterization/Intervention

SELECTION OF GUIDING CATHETER AND TECHNICS FOR PCI IN ANOMALOUS ORIGIN CORONARY ARTERY

Cordis VISTA BRITE TIP

Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System

INTRODUCTION CASE REPORT

The variation of carotid origin, the divergent orientation of common carotid (frequent posterior and left to right direction of right common as

Catheter selection for transradial angiography and intervention

Percutaneous coronary intervention of RIMA. The real challenge!

Guide Catheter Selection and Manipulation from the Wrist

Basic Technique of PAD Intervention (Renal Artery)

Iatrogenic coronary artery dissection is rare, with. Copyright 2017

Department of Internal Medicine, Saitama Citizens Medical Center, Saitama , Japan

IMAGES. in PAEDIATRIC CARDIOLOGY

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

Makoto Sekiguchi, 1 MD, Naoki Sagawa, 1 MD, Akito Miyajima, 1 MD, Shuichi Hasegawa, 1 MD, Masao Yamazaki, 1 MD, and Masahiko Kurabayashi, 2 MD

Introduction. Case Report

(EU), FACC (USA), FSCAI (USA)

Imaging in TAVI. Jeroen J Bax Dept of Cardiology Leiden Univ Medical Center The Netherlands Davos, feb 2013

Coronary angiography and PCI

Radiation Safety Abbott Vascular. All rights reserved.

This is a provisional PDF comprising this cover note and the manuscript as it was upon acceptance for publication.

For Personal Use. Copyright HMP 2013

Copyright HMP Communications

Selection and Use of Basic Equipment : Guiding Catheters, Wires and Balloons

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

Transradial Vascular Interventions Expanding Indications and Increasing Safety

Dual Arterial Access for Stenting of Aortic Coarctation in Patients with Near-Total Descending Aortic Interruption

Effect of Intravascular Ultrasound- Guided vs. Angiography-Guided Everolimus-Eluting Stent Implantation: the IVUS-XPL Randomized Clinical Trial

Percutaneous Transluminal Coronary Angioplasty of Occluded Coronary Arteries New Angiographic Features Related to Success

Percutaneous Intervention for totally Occluded Coarctation Of Aorta. John Jose, Vipin Kumar, Ommen K George Dept Of Cardiology

LM stenting - Cypher

Experience with Transradial and Transulnar Abdominal Angiography and Intervention.

Total occlusion at ostial Left internal mammary graft with successful angioplasty and longterm patency result

Ping-Pong Guide Catheter Technique for Retrograde Intervention of a Chronic Total Occlusion Through an Ipsilateral Collateral

First Transfemoral Aortic Valve Implantation In Bulgaria - Crossing The Valve With The Device Is Not Always

Vascular Access: Management of Complications. Chris Burrell, South West Cardiothoracic Centre, Plymouth

Anatomic variants of the normal coronary artery circulation

Prevention and Management of Vascular Complications Related to Transcatheter Aortic Valve Implantation

Occlusion of right coronary artery by microembolization caused by excessive diagnostic catheter manipulation

Edwards Sapien. Medtronic CoreValve. Inoperable FDA approved High risk: in trials. FDA approved

New York Valves Patient focused evidence-based approach. New York City: 6 December Antonio Colombo

The arterial switch operation has been the accepted procedure

CASE REPORTS: Filters to Prevent Distal Embolization during Coronary Artery Stenting: The Risk of Mousetrap

CORONARY ANOMALIES. Clinical Significance. Disclosures. Definitions. Learning Objectives. Prevalence. Consultant for M2S, Inc.

BILLING BULLETIN. Re: Interventional Cardiology. Bulletin #: 1. Date Issued: November 10, Background

Welcome to the 8 th European Bifurcation Club October Barcelona

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Flexibility of the COMBO Dual Therapy Stent

Bifurcation stenting with BVS

Complete Proximal Occlusion of All Three Main Coronary Arteries Complicated With a Left Main Coronary Aneurysm: A Case Report

CoA Stenting Alexandria Experience

Comparison of transradial and transfemoral approach for carotid artery stenting: RADCAR study

Transradial Artery Approach for Coronary Intervention: Maharat Nakhonratchasima Hospital Experience of The First 20 Cases

Preprocedural evaluation for TAVR

Case Report Treatment of a Distal Left Main Trifurcation Supported by the TandemHeartì Left Ventricular Assist Device

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

TRANSRADIAL PERIPHERAL VASCULAR INTERVENTIONS

Emergent percutaneous coronary intervention for acute myocardial infarction in patients with mirror dextrocardia: case reports and brief review

Thoracic Endovascular Aortic Repair (TEVAR) Indications and Basic Procedure

CPT Code Details

The World s Smallest Heart Pump

CAROTID ARTERY ANGIOPLASTY

Acute dissections of the descending thoracic aorta (Debakey

Dissection of descending aorta treated by stent-graft implantation in a patient with Marfan syndrome

Coronary Artery Anomalies from Birth to Adulthood; the Role of CT Coronary Angiography in Sudden Cardiac Death Screening

I Was Too Late With Device Placement

My Indications are based on anatomy

Coronary artery Dissection. Dr TP Singh MD,DM

Overview of Trasradial Approach for Coronary Angiography and Intervention. A/Prof. Phạm Mạnh Hùng, MD.FACC., FESC

PATIENT SPECIFIC STRATEGIES IN CRITICAL LIMB ISCHEMIA. Dr. Manar Trab Consultant Vascular Surgeon European Vascular Clinic DMCC Dubai, UAE

Cannulating LIMA Graft Using Right Transradial Approach: Two Simple and Innovative Techniques

TRANSRADIAL CARDIAC CATHETERIZATION. Amanda Ryan, DO, Interventional Cardiologist Heart Care Centers of Florida April 13, 2013

Case Report Cardiol Res. 2017;8(2): ress. Elmer

For Personal Use. Copyright HMP 2013

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

How to manage TAVI related vascular complications. Paul TL Chiam MBBS, FRCP, FESC, FACC, FSCAI

Intro: Slide 1. Slide 2. Slide 3. Basic understanding of interventional radiology. Gain knowledge of key terms and phrases

Fighting Through a Heavy Calcified RCA-CTO; Required Retrograde Approach Two Times in the Difficulty of Passing Devices Through

Making the difference with Live Image Guidance

Ostial Stents and Distal Embolic Protection During Renal Stenting

Anatomy and Classification of Aortic Dissection

New Double Stent Technique

PCI for Ostial Lesion

Innovation in Transradial access. Aminian Adel, MD CHU Charleroi Belgium

A transradial approach for carotid artery stenting

Can t See the Forest for the Trees: Transcollateral Crossing of Chronic Total Occlusions

ΣΥΜΠΛΟΚΕΣ ΑΓΓΕΙΟΠΛΑΣΤΙΚΕΣ ΑΓΓΕΙΟΠΛΑΣΤΙΚΗ ΔΙΧΑΣΜΩΝ

Coronary Artery from the Wrong Sinus of Valsalva: A Physiologic Repair Strategy

CIPG Transcatheter Aortic Valve Replacement- When Is Less, More?

SAMPLE EDITION PELVIC AND LOWER EXTREMITY ARTERIES WITH ENDOVASCULAR REVASCULARIZATION. Cardiovascular Illustrations and Guidelines

2017 Cardiology Survival Guide

Le# main treatment with Stentys stent. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy

An Experience of Catheter-Induced Aortocoronary Dissection Complicated by Subtle Coronary Perforation

Complex PCI of an LAD/Diagonal bifurcation lesion (Medina 1,1,1) utilizing the DK Crush technique ".

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

Case Report Anomalous Left Main Coronary Artery: Case Series of Different Courses and Literature Review

PCI for Left Anterior Descending Artery Ostial Stenosis

Your heart is a muscular pump about the size of your fist, located

Transcription:

This is a provisional PDF comprising this cover note and the manuscript as it was upon acceptance for publication. A typeset PDF article will be published soon. Transradial approach superior to transfemoral approach for guide catheter engagement of right coronary artery Article Type Case Report Author(s) Samir B. Pancholy Journal name and URL Clinical Medicine: Case Reports http://la-press.com/journal.php?journal_id=91 This article is published under the terms of the Creative Commons Attribution License. Copyright in the article, its metadata, and any supplementary data is held by the author or authors. We welcome new submissions to this journal at any time. For further information on this journal and how to submit your research to it please visit the journal home page or send an email to the Managing Editor (editorial@la-press.com)

Introduction: Percutaneous coronary intervention (PCI) has become the treatment of choice for patients with symptomatic one vessel coronary artery disease especially when they fail medical therapy alone. Guide catheter support is essential to perform PCI. Transfemoral access is the most commonly used access for PCI. Most guide catheter shapes are designed to allow co axial engagement from the femoral approach. We have observed that transradial approach frequently provides superior guide support in patients where transfemorally placed guides are either suboptimal or on occasion not successful in engaging the target vessel. We describe a case of PCI of right coronary artery arising from right sinus of valsalva, where engaging the ostium from right femoral access was unsuccessful despite aggressive attempts, with subsequent transradial approach successfully allowing guide catheter placement with extreme ease, followed by successful completion of ostial right coronary artery stenting. Case Details: A 72 years old female with history of hypertension, presented with retrosternal and interscapular pain upon minor exertion, for 48 hours. Inferior wall motion abnormality was seen on echocardiogram. EKG and Troponin I was normal. Cardiac catheterization was performed by using 4 french access from right radial artery, using 4 french JL3.5 and JR4 catheters. An 80% ostial stenosis involving the right coronary ostium was noted. No catheter waveform change was noted. 4 french JR4 catheter was placed into the right coronary artery without any difficulty (figure 1). LV function was normal. Manual pressure was used to achieve hemostasis. The patient was brought back to the catheterization laboratory 24 hours later for percutaneous coronary intervention, and transfemoral approach was used selected in view of large reference lumen diameter of the right coronary artery and hence anticipated need for large profile access. A 7 french introducer sheath was placed in the right femoral artery in a standard fashion. Attempts were made using JR4, JR3.5, Williams, AL1, LIMA, Hockey stick, Multipurpose, Champ, Kiez right 1, AR1, MAC 3, MAC 3.5, catheters for approximately two hours, to engage right coronary artery ostium (figure 3 4). Altering the guide characteristics with use of the stiff end of 0.035 /260 cm guidewire and subsequent manipulation was also attempted. All of these attempts were unsuccessful. After using 250 ml of non ionic contrast, the procedure was terminated. The patient was brought back to the catheterization laboratory for a final attempt at PCI from right radial artery access. 6 french Radiofocus Glidesheath (Terumo Medical) was introduced in the right radial artery and 6 french JR4 guiding catheter was placed in the ascending aorta. Right coronary ostium was engaged at the first attempt (figure 5). Catheter waveform ventricularization was noted. The catheter was withdrawn promptly.

A 0.014 /190 cm Hi Torque floppy guidewire was placed in the catheter and the right coronary ostium was promptly re engaged at first attempt. The guidewire was promptly placed in the distal right coronary artery and 4.0/15 mm Cutting balloon was used to pre dilate the right coronary ostium with 1 inflation at 14 atmospheres for 120 seconds (figure 6). A 5.0/18 mm Herculink stent was deployed at the right coronary ostium at 16 atmospheres for 20 seconds. The stent was post dilated with the same balloon with two inflations at 20 atmospheres for 15 seconds each (figure 7). Excellent angiographic result was obtained, confirmed in two orthogonal views. Discussion: Despite major advances in PCI, basic necessities such as co axial and strong guidecatheter support remain the foundation for success. Transfemoral access still remains the most common access for PCI in the U.S. Multiple catheter shapes have been developed to accommodate anatomic variations, but on occasion none of these catheters allow for one to engage the target vessel. Multiple factors play a role in making the anatomy insurmountable. Anomalous aorto ostial anatomy is the most common scenario for difficult target vessel access 1 4. Choosing a suitable guide catheter based on location of anomalous origin and aortic root size, frequently allows the operator to access these anomalous or variant ostia 5.6. Certain dedicated guide catheter shapes are also available for this purpose 7. Catheter manipulation with specific maneuvers has been successful in certain situations 8. Right radial approach has been described to be successful in accessing anomalous left sinus of valsalva origin right coronary artery 9. Infrequently, the unfolding of the ascending aorta, aortic arch as well as descending thoracic aorta and iliac vessels, prohibits the catheter engagement of a non anomalous coronary ostium. We have encountered this problem more frequently using transfemoral approach, and have noticed a surprising lack of these situations using transradial approach. One reason for this difference is the absence of the influence of aorto iliac anatomy on the behavior of the coronary guiding catheter in the ascending aorta. By traversing a shorter segment of aorta, using TRI, the effects of the distal anatomy on proximal catheter behavior are decreased. This is especially noticeable in right coronary interventions. The right coronary catheters when placed from right radial access, provide superior back up support, as opposed to the support provided by the same catheter from femoral approach, in view of the fact that transradial placement allows for these catheters to obtain added support from the contralateral aortic wall, similar to the behavior of the extra backup series guide catheters for the left coronary artery. As PCI is now performed on a wider variety of patients with more elderly in the population undergoing PCI, encountering these procedural situations has become more frequent. TRI from right radial access offers a completely different geometric approach to the ascending aorta, and hence provides an option that femoral approach or catheter

shape variation, does not allow for. TRI from the left radial artery mimics the transfemoral geometry. Hence for guide catheter placement one could argue that transradial approach is certainly offering the benefits of transfemoral approach if left radial artery is used and a different orientation to the aorto ostial junction if the right radial artery is used. We recommend switching to transradial approach when femoral approach does not succeed in engaging the target coronary artery. In order to successfully offer PCI to all subsets of patients, the interventionalist will need to be able to perform transradial intervention. REFERENCES: 1. Mooss AN, Heintz MH. Percutaneous transluminal angioplasty of anomalous right coronary artery. Cathet Cardiovasc Diagn 1989; 16:16 18. 2. Lee BI, Gist HC Jr, Morris EI. Percutaneous coronary artery stenting of an anomalous right coronary artery with high anterior takeoff using standard size 7 French left Judkins guiding catheters. J Invas Cardiol 2003;15:682 684. 3. Topaz O, DiSciascio G, Goudreau E, Cowley MJ, Nath A, Kohli RS, Vetrovec GW. Coronary angioplasty of anomalous coronary arteries: notes on technical aspects. Cathet Cardiovasc Diagn 1990;21:106 111. 4. Ng W, Chow WH. Successful angioplasty and stenting of anomalous right coronary artery using a 6 French Left Judkins #5 guide catheter. J Invas Cardiol 2000;12:373 375. 5. Yip H, Chen MC,Wu CJ, Yeh KH, Fu M, Hang CL, Fang CY, Hsieh KY. Primary angioplasty in acute inferior myocardial infarction with anomalous origin right coronary arteries as infarct related arteries: focus on anatomic and clinical features, outcomes, selection of guiding catheters and management. J Invas Cardiol 2001;13:290 297. 6. Fournier JA, Gonzalez Barrero A, Fernandez Cortacero JA, Sanchez A. Coronary angioplasty of anomalous right coronary artery originating from the left sinus of valsalva. Int J Cardiol 1995; 49:284 286. 7. Qayyum U, Leya F, Steen L, Sochanski M, Grassman E, Cho L, Lewis B. New catheter design for cannulation of the anomalous right coronary artery arising from the left sinus of valsalva.

Catheter Cardiovasc Interv 2003;60:382 388. 8. Seth A. Understand and use your rights. Catheter Cardiovasc Interv 2005; 65(1):41-42 8. Lorin JD, Robin B, Lochow P, Lorenzo A, Sedlis SP. The right radial approach for stenting of lesions in the right coronary artery with anomalous take off from the left sinus of valsalva. J Invas Cardiol 2000;12:478 480.