Endotracheal intubation with airtraq W versus storz W videolaryngoscope in children younger than two years - a randomized pilot-study

Similar documents
Clinical Study McGrath Video Laryngoscope May Take a Longer Intubation Time Than Macintosh Laryngoscope

ISPUB.COM. The Video-Intubating Laryngoscope. M Weiss THE LARYNGOSCOPE INTRODUCTION TECHNICAL DESCRIPTION

Is the Airtraq optical laryngoscope effective in tracheal intubation by novice personnel?

Video laryngoscopy in paediatric anaesthesia in South Africa

The reasons 13/11/ Cost 2. Availability 3. Comparison 4. Complications 5. Knowledge. Pulmonary and critical care medicine (PCCM) fellows.

N. Jagannathan 1, *, J. Hajduk 1, L. Sohn 1, A. Huang 1, A. Sawardekar 1, B. Albers 1, S. Bienia 2 and G. S. De Oliveira 3.

Cronicon ANAESTHESIA. Khaled Mohammed Elnaghy 1 and Javier Yuste 2 * Abstract. Keywords: Intubation; Video laryngoscopes; GlideScope; LMA CTrach

INFORMED CONSENT FOR publication of the present

Z.U.M.J.Vol.19; N.5; September; 2013

Comparison of the Berman Intubating Airway and the Williams Airway Intubator for fibreoptic orotracheal intubation in anaesthetised patients.

Omiros Chalkeidis*, Georgios Kotsovolis, Apostolos Kalakonas, Maria Filippidou, Christos Triantafyllou, Dimitris Vaikos, Epaminondas Koutsioumpas

Fiberoptic bronchoscope and C-MAC video laryngoscope assisted nasal-oral tube exchange: two case reports

Haemodynamic response to orotracheal intubation: direct laryngoscopy versus fiberoptic bronchoscopy

Comparison of the Airtraq to the Bonfils Fibroscope for Endotracheal Intubation in a Simulated Difficult Airway

How do you use a bougie as an airway adjunct for endotracheal intubation?

Anesthetic challenges when elective case becomes emergent

DIFFICULT AIRWAY MANAGMENT. Dr.N.SANTHOSH KUMAR MD ANESTHESIA (2 nd Yr)

Hemodynamic response to laryngoscopy in ischemic heart disease: Macintosh blade versus GlideScope videolaryngoscope

Displacement of the epiglottis during intubation with the Pentax-AWS Airway Scope. Suzuki, Akihiro ; Katsumi, Norifumi ; Honda, Takashi ; Sasakawa,

LARYNGOSCOPE IN MYASTHENIA GRAVIS PATIENTS

Video Laryngoscopy and its future in Airway Management

Airway Anatomy. Soft palate. Hard palate. Nasopharynx. Tongue. Oropharynx. Hypopharynx. Thyroid cartilage

A comparison between the GlideScope Ò Video Laryngoscope and direct laryngoscope in paediatric patients with difficult airways a pilot study

Samal et al: Comparison of the Macintosh and Airtraq Laryngoscope

British Journal of Anaesthesia 102 (4): (2009) doi: /bja/aep013 Advance Access publication February 20, 2009

Use of the Aintree Intubation Catheter with the Laryngeal Mask Airway and a Fiberoptic Bronchoscope in a Patient with an Unexpected Difficult Airway

Hong Kong Journal of Emergency Medicine. KL Tsui, CY Hung, CW Kam. t p= p=0.004

Educational Session: Evaluation and Management of the Difficult Airway

The Superiority Of Mcgrath Videolaryngoscope After Failed Conventional Laryngoscopy

Recent Advances in Airway Management HA Convention 2014

Nasotracheal intubation with Parker Flex-Tip versus preformed nasal endotracheal tubes for children undergoing adenotonsillectomy

Comparison between C-MAC video-laryngoscope and Macintosh direct laryngoscope during cervical spine immobilization

Comparison of Indirect Video Laryngoscopes in Children Younger than Two Years of Age: A Randomized Trainee Evaluation Study

This is a repository copy of Videolaryngoscopy versus direct laryngoscopy for tracheal intubation in children (excluding neonates).

British Journal of Anaesthesia 100 (4): (2008) doi: /bja/aen002 Advance Access publication January 31, 2008

Comparison. F Agro immobilization. to DL Trauma/SCI. GS experiences. to other. GS experiences. GS experiences. to DL.

Hemodynamic responses to orotracheal intubation with a video laryngoscope. in infants: a comparison study

AN ALGORITHM FOR EASY INTUBATION. COMBINED USE OF THE MACINTOSH LARYNGOSCOPE AND FLEXIBLE BRONCHOSCOPE IN UNEXPECTED DIFFICULT INTUBATION

ENDOTRACHEAL INTUBATION POLICY

Comparison of laryngoscopy and intubating conditions using kings vision laryngoscope and C-MAC video laryngoscope

The Glidescope Ò system: a clinical assessment of performance

Comparison of two methods of gum elastic bougie aided endotracheal intubation using Airtraq video laryngoscope

LEVITAN S FIBREOPTIC STYLET: BEYOND BARRIERS. - Our Perspective.

COMPARISON OF DIRECT VERSUS INDIRECT LARYNGOSCOPY FOR INTUBATION IN THE PREHOSPITAL SETTING: A SYSTEMATIC REVIEW AND META-ANALYSIS

Retrospective audit of the air-q intubating laryngeal airway as a conduit for tracheal intubation in pediatric patients with a difficult airway

A systematic review of the role of videolaryngoscopy in successful orotracheal intubation

Airway Management. Teeradej Kuptanon, MD

British Journal of Anaesthesia 101 (6): (2008) doi: /bja/aen288 Advance Access publication October 3, 2008

Patient-specific depth of endotracheal intubation-from anthropometry to the Touch and Read Method

1 Chapter 40 Advanced Airway Management 2 Advanced Airway Management The advanced airway management techniques discussed in this chapter are to

Incidence and predictors of difficult nasotracheal intubation with airway scope

Chapter 40 Advanced Airway Management

The LMA CTrach TM, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients

Cervical Spine Motion

PREDICTORS OF DIFFICULT INTUBATION: STUDY IN KASHMIRI POPULATION

Difficult Airway. Victor M. Gomez, M.D. Pulmonary Critical Care Medicine Medical City Dallas Hospital

Clinical Comparison of Lightwand-guided versus Conventional Endotracheal Intubation

British Journal of Anaesthesia 102 (1): (2009) doi: /bja/aen342

Airway Management & Safety Concerns Experience from Bariatric Surgery

Laryngoscopy: Time to broaden our horizon.

Study of Comparison of Standard And English Macintosh Laryngoscope Blades in Patients Undergoing Surgery Under General Anaesthesia.

External Laryngeal Manipulation for Better Laryngeal View

GlideScope Cobalt AVL Video Baton for Intubation in Infants Weighing Less Than 10 Kilograms

Corresponding author: X.-H. Li

Published online 2015 December 5. Research Article

NiravKotak 1, Abhishek Kesarwani 2 1

Al-Qasmi et al. Al-Qasmi et al. Trials 2013, 14:298

Advanced Airway Management. University of Colorado Medical School Rural Track

(ix) Difficult & Failed Intubation Queen Charlotte s Hospital

The implication of using dominant hand to perform laryngoscopy: an analysis of the laryngoscopic view and blade-tooth distance

Preface... Acknowledgements... Contributors... 1 The Difficult Airway: Definitions and Algorithms The Expected Difficult Airway...

RESPIRATION AND THE AIRWAY. Editor s key points

Comparison of McGrath Series 5 video laryngoscope with Macintosh laryngoscope: A prospective, randomised trial in patients with normal airways

A clinical evaluation of the Bonfils Intubation Fibrescope*

The Mallampati Test versus the Upper Lip Bite Test in Predicting Difficult Intubation. Chance Buttars BSN, BA Bryan College of Health Sciences

Emergency Department/Trauma Adult Airway Management Protocol

This interdisciplinary clinical support document provides guidelines for the safe establishment of an artificial airway.

EUROANESTHESIA 2007 Munich, Germany, 9-12 June 2007

In 2011 I received an unrestricted lecture honorarium from Ambu I have been loaned equipment by Intavent Direct (Teleflex) and Aircraft Medical As an

MD (Anaesthesiology) Title (Plan of Thesis) (Session )

Difficult Airway. Department of Anesthesiology University of Colorado Health Sciences Center (prepared by Brenda A. Bucklin, M.D.)

Comparative Evaluation of Performance of Videolaryngoscope vs Fastrach Intubating Laryngeal Mask Airway

Difficult Airway Management during Anesthesia: A Review of the Incidence and Solutions

C-MAC videolaryngoscope compared with direct laryngoscopy for rapid sequence intubation in an emergency department A randomised clinical trial

The era of video laryngoscopy has entered its second decade. Video Laryngoscopy: A Debate

9/20/18. Ear To Sternal Notch. Primary Methods to Rescue & Prevent Failed Intubation. Ear to Sternal Notch Position

Hemodynamic Response to Tracheal Intubation Using New Airway Intubating Devices

Evaluation of the Airtraq Ò and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation*

Airway/Breathing. Chapter 5

Pediatric Difficult Airway Management. R2 Nichakan Rewurai R2 Pattiya Suttidate Supervisor: Assist. Prof. Sahatsa Mandee

Optimising tracheal intubation success rate using the Airtraq laryngoscope

Equipment: NRP algorithm, MRSOPA table, medication chart, SpO 2 table Warm

Success of Tracheal Intubation with Intubating Laryngeal Mask Airways

Anaesthesia for Thoracic Surgery

RESPIRATION AND THE AIRWAY First clinical experience of tracheal intubation with the SensaScope Ò, a novel steerable semirigid video stylet

Endotracheal intubation using semi-rigid optical stylet in simulated difficult airways of high grade modified Cormack and Lehane laryngeal views

The Laryngeal Mask and Other Supraglottic Airways: Application to Clinical Airway Management

Cuffed or uncuffed ETT in pediatric anesthesia? Dr. Renata Haghedooren Dr. Sophie Chullikal Dr. Julie Lauweryns

Nobuko Tachibana Yukitoshi Niiyama Michiaki Yamakage

Unanticipated difficult tracheal intubation - during routine induction of anaesthesia in an adult patient

Transcription:

Sørensen and Holm-Knudsen BMC Anesthesiology 2012, 12:7 RESEARCH ARTICLE Open Access Endotracheal intubation with airtraq W versus storz W videolaryngoscope in children younger than two years - a randomized pilot-study Martin Kryspin Sørensen 1* and Rolf Holm-Knudsen 2 Abstract Background: New laryngoscopes have become available for use in small children. The aim of the study was to compare the Storz W videolaryngoscope (SVL) to the Airtraq W Optical laryngoscope (AOL) for tracheal intubation in children younger than two years of age who had a normal airway assessment. Our hypothesis was that the SVL would have a better success rate than the AOL. Methods: Ten children aged 2 years or younger scheduled for elective cleft lip/palate surgery were included. The anesthesia was standardized and a Cormack-Lehane (CL)-score was obtained using a Macintosh laryngoscope. After randomization CL-score and endotracheal tube positioning in front of the glottis was performed with one device, followed by the same procedure and intubation with the other device. The video-feed was recorded along with real-time audio. The primary endpoint was the success rate, defined as intubation in first attempt. Secondary endpoints were the time from start of laryngoscopy to CL-score, tube positioning in front of the glottis, and intubation. Results: Two intubation attempts were needed in two of five patients randomized to the SVL. The difference in time (SVL vs. AOL) to CL-score was 4.5 sec (p = 0.0449). The difference in time (SVL vs. AOL) to tube positioning was 11.6 sec (p = 0.0015). Time to intubation was 29.0 sec for SVL and 15.8 sec for AOL. Conclusion: No difference in the success rate of endotracheal intubation could be established in this ten patient sample of children younger than two years with a normal airway assessment scheduled for elective cleft lip/palate surgery. However, the Airtraq W Optical videolaryngoscope showed a number of time related advantages over the Storz W videolaryngoscope. Because of the small sample size a larger trial is needed to confirm these findings. Both devices were considered safe in all intubations. Trial registration: ClinicalTrials.gov; Identifier NCT01090726. Keywords: General anaesthesia, Airway management, Intratracheal intubation Background Videolaryngoscopes and optical laryngoscopes have been developed and used in adults during the last decade, and some of these are now available for small children [1]. The devices have proven effective in adults [2], but whether downscaling the adult equipment will work efficiently in small children is yet to be proven, though good initial experiences are reported [3]. Small children are not only * Correspondence: martin@kryspin.dk 1 Department of Anaesthesia, Centre of Head and Orthopaedics, Copenhagen University Hospital, Rigshospitalet, Blegdamsvej 9, 2100, Copenhagen, Denmark shorter than larger children and adults, but relative differences in the dimensions of the mouth and of the upper airways are present between the groups. Small children have a relatively larger tongue that takes up more space in the oral cavity. The jaw is shorter making it more difficult to displace the tongue, and the larynx is localized more cephalad. The epiglottis is long, narrow, omega-shaped, and angled towards the lumen of the airway [4]. For these reasons one cannot expect to have the same excellent overview in a small child with a downscaled laryngoscope blade per se as in a larger child or in an adult. Airway related problems are among the most critical 2012 Soerensen and Holm-Knudsen; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Sørensen and Holm-Knudsen BMC Anesthesiology 2012, 12:7 Page 2 of 5 complications in pediatric anesthesia, with an incidence four times higher among children aged one year or younger than in older children. Thus airway management in small children remains an important research area [5]. The main objective of the pilot-study was to make a direct comparison of the Storz W Berci-Kaplan videolaryngoscope (SVL) (Figure 1) and the Airtraq W Optical videolaryngoscope (AOL) (Figure 2) using a Macintosh laryngoscope as reference for endotracheal intubation in small children with a normal preoperative airway assessment, thereby generating data that can be used for sample size calculations for larger trials in similar settings. The evaluation was focused on key components in the intubation procedure. Our hypothesis was that SVL would have a better success rate than AOL. Methods The Regional Ethics Committee Capital Region (Address: Kongens Vænge 2, 3400 Hillerød, Denmark) approved the trial the 24 th of February 2010 (Protocol: H-2-2009-148). The trial was registered at ClinicalTrials.gov (Identifier: NCT01090726) prior to inclusion of the first patient. Written informed consent was obtained from the parents of all participating patients. Patients were eligible if they were between 1 month and 2 years of age, were cleft lip/palate surgical patients with an ASA Physical Scale class 1 2, and had an indication of intubation for general anesthesia. We excluded patients if a history of difficult intubation was present, if the child had Figure 1 Storz W Berci-Kaplan videolaryngoscope. Figure 2 Airtraq W Optical videolaryngoscope. breathing difficulties during sleep or a dysmorphic feature with apparent micro- or retrognathia. Patients were randomized 1:1 according to a computer generated list (GraphPad Software W, Inc., La Jolla, California, USA). A total of 10 envelopes were prepared for the trial, by staff with no other involvement in the trial. The patients were randomized to be intubated by either the SVL or the AOL. The patients were monitored with a three lead ECG, non-invasive blood pressure measurement, pulse oximetry, capnography and temperature. Induction of anesthesia was done with sevoflurane and an intravenous access was established. Intravenous fentanyl (2.5 microgram/kg) and cisatracurium (0.1 mg/kg) was given. Mask ventilation and sevoflurane inhalation were continued for 4 minutes after which the time measurements were done and the endotracheal intubation was performed. Intubation was preceded by a crossover design with three laryngoscopies performed with three different laryngoscopes. Between each laryngoscopy the patient was ventilated by face mask. First, laryngoscopy was performed with a Macintosh blade and Cormack-Lehane (CL)-score [6] and timing to CL-score were registered. Then laryngoscopy was performed with either AOL or SVL depending on randomization and the CL-score with this device was registered. Time to CL-score and time to ready to intubate position of the endotracheal tube just in front of the glottis were also registered. Finally the patient was intubated using the other device (AOL or SVL). The CL-score with this device was registered along with time to CL-score, time to position the endotracheal tube in ready to intubate in front of glottis and time to complete endotracheal intubation, defined as passage of the

Sørensen and Holm-Knudsen BMC Anesthesiology 2012, 12:7 Page 3 of 5 Table 1 Patient characteristics, case by case Allocation SVL AOL AOL SVL AOL AOL SVL AOL SVL SVL Weight, kg 7.1 6.8 9.8 9.3 6.7 6.0 6.9 13.0 6.3 7.6 Age, months 7 3 16 16 3 3 3 17 4 4 vocal cords with the endotracheal tube. The evaluation of the airway was performed using a Macintosh blade, which is our standard method in children weighing more than 3 kg. A laryngoscope blade size 0 was used in children younger than six months otherwise a size 1 blade was used. When using the AOL the size was chosen from the recommendation on the package. AOL infant (size 0) for endotracheal tubes 3.0 and 3.5, and AOL pediatric (size 1) for size 4.0. With the SVL a Miller-like bladesize0wasused. The blade resembles an ordinary Miller blade, but is lower and half a cm longer. In all cases with all three devices the tip of the laryngoscope blade was placed in the vallecula and external pressure was applied to the neck if necessary. Preformed oral Microcuff W endotracheal tubes were used forintubationinallcases.whenusingthesvlamalleable stylet with the tip bent as a hockey-stick was placed in the tube. Only indirect laryngoscopy, using the video monitor, was attempted with the SVL. When using the AOL only thedistalhalfofthepreformedtubewaskeptinthetube conduit during advancement of the tube as described by Xue et al [7]. The experiment was finished upon completed intubation, defined by verification of ETT placement. Only two intubation attempts were accepted. After this the experimental setup would be considered finished. In case of continued failure to intubate the responsible anesthesiologist would determine how to proceed. All investigations were performed by one experienced pediatric anesthesiologist, who had performed 20 or more endotracheal intubations with each of the new devices (AOL, SVL) in small children prior to inclusion of patients in the trial. Both the AOL and the SVL were connected via their monitors to a laptop computer. The video-feed was integrated in the software program Final Cut Pro 7 (Apple Inc., California, U.S.A.) with live audio from the room. An equipment rack was built for the purpose with monitors, laptop and cables securely clamped. This ensured that the setup would be the same for all patients. A switch made it possible to easily control the source of video-input to the computer, without affecting the ease of changing devices, thetimerecording,orthesafetyofthepatient.therecording was started when the first laryngoscopy with the Macintosh laryngoscope was initiated. Time recording was done with both video and audio recording and by having the anesthesiologist mark the endpoints with a clear voice. The integrated recording was analyzed after the procedure. Endpoints were measured and evaluated independently two times, and then they were compared to identify potential discrepancies. If a discrepancy was found, the shortest time or best rating was chosen. The primary endpoint was the success rate, defined as intubation in first attempt. Secondary endpoints were CL, time from start of laryngoscopy to CL, time to ETT positioning in front of the glottis, and time to endotracheal intubation. Time measurement was started from the point where the device was lifted off the table. Time to CL-score was recorded, and it was defined as the time point when the best possible view was achieved including the use of external manipulation. If a secondary intubation attempt was needed, all time recordings were based on the secondary attempt alone. Statistical analysis No sample size calculation has been performed. An objective of this pilot-study was to determine the baseline data, on which a sample size calculation could be made for similar but larger studies. The Wilcoxon test was used for statistical analysis of paired data. A P-value of less than 0.05 was considered statistical significant. All statistical calculations were done using SAS statistical software, Version 9.1 (SAS Institute, Cary, NC, USA). Figure 3 Trial profile. Results In the period from March 2010 to October 2010 we included ten patients in the trial (Table 1; Figure 3). The

Sørensen and Holm-Knudsen BMC Anesthesiology 2012, 12:7 Page 4 of 5 Table 2 Results, case by case Case 1 2 3 4 5 6 7 8 9 10 Mean (SD) Allocation - intubation SVL AOL AOL SVL AOL AOL SVL AOL SVL SVL CL-score, Macintosh 1 2 1 2 1 2 1 1 1 1 CL-score, Airtraq 1 1 1 1 1 1 1 1 1 1 CL-score, SVL 1 1 1 1 1 1 1 1 1 1 Time to CL-score, Macintosh, sec 6 12 6 12 9 16 8 5 7 11 9.2 (3.49) Time to CL-score, Airtraq, sec 6 9 7 5 6 7 7 7 13 7 7.4 (2.22) Time to CL-score, SVL, sec 9 24 5 6 7 9 9 20 24 6 11.9 (7.64) Ready to intubate position, Airtraq, sec 16 16 19 14 20 13 26 11 25 15 17.5 (4.97) Ready to intubate position, SVL, sec 34 37 22 19 31 19 28 37 40 24 29.1 (7.84) Intubation, sec 34 16 19 19 20 13 28 11 40 24 Intubation attempts 2 1 1 2 1 1 1 1 1 1 SVL-group weighed 7.4 (1.1) kg and the AOL-group weighed 8.5 (2.9) kg. The age was 6.8 (5.4) months in the SVL-group and 8.4 (7.4) months in the AOL-group. Due to technical problems in two of five patients randomized to the SVL, two intubation attempts were needed: one due to fogging of the lens and the other due to sudden separation of the blade from the handle. All patients were intubated in the first attempt with the AOL (Table 2). The difference in time to CL-score between the devices (SVL-AOL) was 4.5 sec (p = 0.0449). The difference in time between the devices (SVL-AOL) to place the ETT in a ready to intubate position in front of the glottis was 11.6 sec (p = 0.0015) (Table 3). Time to endotracheal intubation was 29.0 sec for SVL and 15.8 sec for AOL. All patients had a CL-score of 1 with both the SVL and the AOL, whereas three patients had a CLscore of 2 with a Macintosh blade. No patient developed postoperatively stridor. No time discrepancy of more than 1 sec was found between the two independent evaluations of the integrated video and audio recordings. Discussion In two well-matched groups (Table 1) intubation was successful in the first attempt in 5/5 with the AOL and 3/5 with the SVL. The AOL was significantly faster than the SVL in all measured procedural elements of intubation in small children. CL-scores were 1 in all measurements with the two devices (Table 2). All patients were safely intubated. Table 3 Results SVL-AOL P-value Difference in time to CL-score, sec 4.5 (1.9) 0.0449 Difference in time to Ready to intubate 11.6 (2.6) 0.0015 position, sec Paired data, presented as mean (SD). A few limitations of the study must be mentioned. First, only one anesthesiologist performed all the investigational procedures and did this unblinded. Although experienced in intubation of this patient group with these devices, his personal skills could be reflected in the results of the investigation. In order to eliminate this bias the number of consultants performing the laryngoscopies would have to be increased. However, this would introduce other confounders such as the differing in learning curves with the devices and variable overall intubation experience in small children between the consultants. It was therefore decided to have only one consultant with extensive training in intubating small children with both devices, although unintentional biases of the intubator could have influenced the results. Blinding was not possible in this study. We compensated for these limitations by having every experimental procedure video recorded chronologically with integrated audio from the operating room, to make the results as objective as possible. The video evaluation was done independently twice. Maximum discrepancies of only one second between the recordings on all endpoints were found, and we consider this part of the study reproducible. Secondly, too few patients were included in order to do statistical analysis of unpaired data. However, this was a pilot-study and as such the data can still be used for sample size calculations in similar settings of future trials. In a comparison of the Glidescope W and the SVL on a pediatric mannequin, time to endotracheal intubation was 19.9 (6.1) sec with the SVL under normal conditions [8]. We recorded a time to intubation with the SVL of 29.0 sec, with all measurements being 19 sec or above, but we only had five observations. Our results, although based on very few observations, are supported by Vlatten et al. who performed a randomized trial comparing the SVL to direct laryngoscopy in 56 children, aged 4 years or younger. They reported time to intubation to be 27 sec [9].

Sørensen and Holm-Knudsen BMC Anesthesiology 2012, 12:7 Page 5 of 5 The application of results from mannequin studies to the clinic is becoming increasingly controversial, as it has proliferated without being followed by clinical trials on humans [10]. A central problem with mannequin studies is that one does not know exactly where the mannequins differ from the variety in the population. One could speculate that when intubating patients one is more cautious, and that this will prolong the endpoint of time to intubation as compared to the mannequin setting. The AOL has been evaluated in a case series of 20 children aged 14 days to 9 years with both normal and difficult airways, and in conclusion the device was found safe and beneficial [11]. Although the case series had a wider age range than our pilot-study, these findings are in good accordance with ours. A couple of maneuvers have been proposed to facilitate intubation with AOL easier. When using a preformed endotracheal tube one can bypass the exoteric tube conduit of the AOL with the upper part of the tube. Other maneuvers have been proposed to facilitate successful intubation with the AOL when tube advancement is difficult [12]. These include the use of a stylet, an Endoflex-tube, or a fiberoptic bronchoscope. It is best to optimize the view before an intubation attempt. In this report we present data from a direct comparison between the Airtraq W and the Storz W Berci-Kaplan videolaryngoscope in small children. In the narrow age group investigated, there are distinct features in the airway dimensions, where they differ from infants and older children. This could pose a challenge in the use of the two devices. It is not possible to extrapolate our results in children with normal airways to small children with difficult airways, as narrow space in the airway poses special challenges to the equipment. Failure to intubate these children with the AOL has been published [13]. Further studies, or case series, in small children with difficult airways are awaited before the usefulness of these devices in these children can be established. A novel endpoint in the current study was the ready to intubate tube positioning. The introduction of this endpoint allowed the use of a paired statistical analysis on a procedural relevant endpoint without increasing the risk for the patients. However, this endpoint is a surrogate endpoint for intubation with limited clinical impact. In a similar but larger trial, we would therefore recommend the use of time to intubation or success rate in an unpaired design as primary endpoint with our data as the basis for the sample size calculation of a direct comparison between the Airtraq W and the Storz W Berci-Kaplan videolaryngoscope in small children. In conclusion, no difference in the success rate of endotracheal intubation could be established in this ten patient sample of children younger than two years with a normal airway assessment scheduled for elective cleft lip/palate surgery. However, the Airtraq W Optical videolaryngoscope showed a number of time related advantages over the Storz W videolaryngoscope. Because of the small sample size a larger trial is needed to confirm these findings. Both devices were considered safe in all intubations. Competing interests Both authors declare that they have no competing interests. Authors' contributions MKS wrote the protocol, assisted in data collection, did the statistical analyses, and wrote the manuscript. RHK assisted in writing the protocol, collected the data, assisted in the statistical analyses, and assisted in writing the manuscript. Both authors read and approved the final manuscript. Author details 1 Department of Anaesthesia, Centre of Head and Orthopaedics, Copenhagen University Hospital, Rigshospitalet, Blegdamsvej 9, 2100, Copenhagen, Denmark. 2 Department of Anaesthesia, Centre of Head and Orthopaedics, Copenhagen University Hospital, Rigshospitalet, Blegdamsvej 9, 2100, Copenhagen, Denmark. Received: 5 January 2012 Accepted: 18 April 2012 Published: 30 April 2012 References 1. Doherty JS, Froom SR, Gildersleve CD: Pediatric laryngoscopes and intubation aids old and new. Paediatr Anaesth 2009, 19(Suppl 1):30 37. 2. Pott LM, Murray WB: Review of video laryngoscopy and rigid fiberoptic laryngoscopy. Curr Opin Anaesthesiol 2008, 21:750 758. 3. Holm-Knudsen R: The difficult pediatric airway a review of new devices for indirect laryngoscopy in children younger than two years of age. Paediatr Anaesth 2011, 21:98 103. 4. Holm-Knudsen RJ, Rasmussen LS: Paediatric airway management: basic aspects. Acta Anaesthesiol Scand 2009, 53:1 9. 5. Tay CL, Tan GM, Ng SB: Critical incidents in paediatric anaesthesia: an audit of 10 000 anaesthetics in Singapore. Paediatr Anaesth 2001, 11:711 718. 6. Cormack RS, Lehane J: Difficult tracheal intubation in obstetrics. Anaesthesia 1984, 39:1105 1111. 7. Xue FS, Liu HP, Liao X, Yuan YJ, Liu JH: Endotracheal intubation with Airtraq optical laryngoscope in the pediatric patients. Paediatr Anaesth 2011, 21:703 704. 8. Hurford DM, White MC: A comparison of the Glidescope and Karl Storz DCI videolaryngoscopes in a paediatric manikin. Anaesthesia 2010, 65:781 784. 9. Vlatten A, Aucoin S, Litz S, Macmanus B, Soder C: A comparison of the STORZ video laryngoscope and standard direct laryngoscopy for intubation in the Pediatric airway a randomized clinical trial. Paediatr Anaesth 2009, 19:1102 1107. 10. Rai MR, Popat MT: Evaluation of airway equipment: man or manikin? Anaesthesia 2011, 66:1 3. 11. Hirabayashi Y, Shimada N: Airtraq optical laryngoscope: initial clinical experience in 20 children. J Anesth 2010, 24:148 149. 12. Xue FS, He N, Liu JH, Liao X, Xu XZ, Zhang YM: More maneuvers to facilitate endotracheal intubation using the Airtraq laryngoscope in children with difficult airways. Paediatr Anaesth 2009, 19:916 918. 13. Holm-Knudsen RJ, White J: The Airtraq may not be the solution for infants with difficult airways. Paediatr Anaesth 2010, 20:374 375. doi:10.1186/1471-2253-12-7 Cite this article as: Sørensen and Holm-Knudsen: Endotracheal intubation with airtraq W versus storz W videolaryngoscope in children younger than two years - a randomized pilot-study. BMC Anesthesiology 2012 12:7.