CELL-DYN Strength in Technology, Proven Reliability. Optical WBC Technology. Patented M.A.P.S.S. Differential. Multiple Technologies

Similar documents
CELL-DYN 3700 Strength in Technology, Proven Reliability

Abbott Cell-Dyn Reticulocyte Method Comparison and Reticulocyte Normal Reference Range Evaluation

Hematology 101. Cindy Rogers, MT(ASCP) Diagnostics System Specialist

Automated Hematology Analyzer. Differentiate with the XT-4000i

3. Blood Cell Histograms:

BLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S.

Guide to the 1-3 Minute Blood Film Microscopic Review: Why and How?

Full Blood Count analysis Is a 3 part-diff good enough? Dr Marion Münster, Sysmex South Africa

A Look Into the Determination of Cell Morphology in Hematology in the 21 st Century. Ramon Simon-Lopez, MD Global Scientific Director Beckman Coulter

Lavender Top Management SUCCESS BEYOND FINANCES

Lavender Top Management SUCCESS BEYOND FINANCES. Mission/ Vision

HumaCount 5D. Outperforming 5-part Hematology System. CoreLab DX. Hematology

Evaluation of haematology analyzer CELL-DYN 3700 SL

Evaluation of the Abbott Cell-DYN 3500 Hematology Analyzer in a University Hospital

First comparative evaluation of leucocyte differential and reticulocyte count between Abbott Cell -DYN 3700 and Beckman-Coulter Gen S

HM5. Hematology Analyzer BETTER. ACTUALLY.

XN-SERIES. XN Technology and Case Studies

10/30/2015. XN Case Studies: Every Picture Tells a Story

Advanced Hematology Five-Part Differential. Simple Operation

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

Evaluation of the Abbott CELL-DYN 4000 Hematology Analyzer

Sysmex Journal International Vol.9 No.2 (1999)

Precision and Accuracy of the Leukocyte Differential on the Sysmex XE-2100

Continuing Education Questions

Complete Blood Count (CBC) Assist.Prof. Filiz BAKAR ATEŞ

Kathleen Finnegan MS MT(ASCP)SHCM

INFECTION/ INFLAMMATION

ADx Bone Marrow Report. Patient Information Referring Physician Specimen Information

Performance evaluation of Celltac G: a new automated hematology analyzer

Clinical use of flow cytometry

Getting Beyond the Flags: Quantitative assessment of immature granulocyte (IG) populations may improve the assessment of sepsis and inflammation.

XN-SERIES. Hematology Case Studies: Every Picture Tells a Story

Changes in Automated Complete Blood Cell Count and Differential Leukocyte Count Results Induced by Storage of Blood at Room Temperature

Interpreting Hematology Scatter-Plots; One Cancer Center s Keys to Seeing the BIG Picture

ADVANCED HAEMATOLOGY BATTLE OF THE BANDS. Dennis B. DeNicola, DVM, PhD, DACVP IDEXX Laboratories, Inc. Westbrook, Maine, USA BACKGROUND

Complete Blood Count (CBC)

XN series. Case interpretation. Gebruikersdag Vlaanderen- 6 oktober 2016

Scoring System for Detecting Spurious Hemolysis in Anticoagulated Blood Specimens

Brief Communication Diagnostic Hematology

NEW YORK STATE CYTOHEMATOLOGY PROFICIENCY TEST PROGRAM Glass Slide - November 2016

Hematopathology Case Study

Hematology 101. Blanche P Alter, MD, MPH, FAAP Clinical Genetics Branch Division of Cancer Epidemiology and Genetics Bethesda, MD

Paper ID: ART

Interpreting the CBC. Robert Miller PA Assistant Professor of Clinical Pediatrics and Family Medicine USC Keck School of Medicine Retired

Rapid Laboratories In House Tests

EDUCATIONAL COMMENTARY BLOOD CELL IDENTIFICATION

Customer Information Literature List White Blood Cells

Blutbild 2012: Automatisiert oder manuell? Georg Stüssi Servizio di Ematologia Istituto Oncologico della Svizzera Italiana

Blood Cell Identification Graded

Evaluation of Coulter S-Plus Three-part Differential in Population with a High Prevalence of Abnormalities

DR SUDHIR MEHTA MD,MNAMS,FICP. Senior Professor & Head Medical Unit SMS Medical College & Hospital Jaipur

SediVue Dx Urine Sediment Analyser. Fresh samples / Revolutionary technology / A new standard of care. The Complete Diagnostic Solution

EDUCATIONAL COMMENTARY DIFFERENTIATING IMMATURE PERIPHERAL BLOOD CELLS

LEANING Away Waste and Improving Patient Care with Advances in Hematology

Differential Blood Smear H3

Blood DLC, Retic count, PCV, Hb and ESR. Dr. Tamara Alqudah

5/1/2017 DISCUSSION POINTS. Clinical Utility of Immature Cell Indices Beyond the Routine CBC John E. Donnelly BSN, RN

It s Easier Than you Think How to Implement the Advanced Clinical Parameters

Hematopathology Case Study

HAEMATOLOGICAL EVALUATION OF ANEMIA. Sitalakshmi S Professor and Head Department of Clinical Pathology St John s medical College, Bangalore

Flow cytometry leukocyte differential : a critical appraisal

e-figure 1. The design of the study.

+ Bloodsmear exam 1/12/2014. Goals. Instrument Technologies

2007 Workshop of Society for Hematopathology & European Association for Hematopathology Indianapolis, IN, USA Case # 228

CASE STUDIES PERIPHERAL BLOOD AND BODY FLUIDS

Changes of hematological references depends on storage period and temperature conditions in rats and dogs

Ordering Physician CLIENT,CLIENT. Collected REVISED REPORT

Evaluation of the Diagnostic Performance of the Sysmex XT-2000i Automated Hematology Analyzer in the Detection of Immature Granulocytes

Sue Jung Kim, MD, MS; Yoonjung Kim, MD; Saeam Shin, MD; Jaewoo Song, MD, MS; Jong Rak Choi, MD, PhD

Quality control in the hematology laboratory for the sake of the patient. Dr Marion Münster Manager Medical & Scientific Affairs Sysmex South Africa

3/31/2017 OBJECTIVES CASE STUDY #1 MANUAL REVIEW. Hematology Case Studies: Every Picture Tells a Story

NOTE: This table will be discontinued after this lot.

Detection of important abnormalities of the differential

Auto Validation and Management Reports Using Sysmex WAM. Alfonso Ziccardi Laboratory Operation Manager for AP/CP/Safety Officer

Combining. and New Diagnostic. to Help Clinicians Achieve. Patient Outcomes at. per Healthcare Encounter

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Cbc with differential

LYDIA NELSON, M.S., MT(ASCP), SH, SAMUEL CHARACHE, M.D., SANDRA WINGRELD, MT(ASCP), AND EDWARD KEYSER, MT(ASCP)

1.) 3 yr old FS Siamese cat: 3 day history of lethargy, anorexia. Dyspneic, thin, febrile.

By Dr. Mohamed Saad Daoud

Formation of Blood Cells

EDUCATIONAL COMMENTARY DISTINGUISHING MORPHOLOGIC LOOK-ALIKES

Refrigerated Storage Improves the Stability of the Complete Blood Cell Count and Automated Differential

Differential Blood Smear H3

HISTOLOGY VIRTUAL LABORATORY BLOOD AND LYMPHATICS SYSTEM

Cardiocap/5. GE Healthcare. The compact, all-in-one, critical care monitor. Features. Available options

Blood Cells Med Terms Quiz

Notes for the 2 nd histology lab

EDUCATIONAL COMMENTARY MORPHOLOGIC CHANGES IN PERIPHERAL BLOOD CELLS

Vision Hema. Additional modules

The LaboratoryMatters

Proper Slide Preparation

Beyond the CBC Report: Extended Laboratory Testing in the Evaluation for Hematologic Neoplasia Disclosure

Detection. personal. Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily.

VETERINARY HEMATOLOGY ATLAS OF COMMON DOMESTIC AND NON-DOMESTIC SPECIES COPYRIGHTED MATERIAL SECOND EDITION

Cytochrome-C (rat, mouse) forward GGAGGCAAGCATAAGACTGG. mouse hexokinase 2 gene, intron 9 reverse GGGAACACAAAAGACCTCTTCTGG

COMPANY OR UNIVERSITY

Differential Blood Smear H3

Tube 1 : FLAER/CD24/CD16/CD15/CD45

Transcription:

CELL-DYN 3700 Strength in Technology, Proven Reliability Optical WBC Technology Patented M.A.P.S.S. Differential Multiple Technologies

CELL-DYN 3700 Multiple Technologies One Superior Result Multiple Technologies Improve Accuracy and Increase the Number of Reportable Results The CELL-DYN 3700 offers advanced diagnostic capability for clinical laboratories. The instrument performs simultaneous laser and impedance measurements on white blood cells, and has been designed to choose the correct answer even in the presence of problematic specimens. This capability equates to better accuracy, less review and a higher number of reportable patient results. The CELL-DYN 3700 can be configured as a fully automated system including a sample loader or as a single sample closed system. The system provides a complete 23-parameter CBC at a rate of 90 samples per hour. Advanced Technology Minimizes Obsolescence The CELL-DYN multiple technology platform is one of the most advanced cell counting systems available. Dual-technology assures powerful and efficient analysis today and in the future.

MONO LYM BASO NEU EOS M.A.P.S.S. Differential M.A.P.S.S. technology provides a differential virtually free of interference from NRBCs, clumped platelets, and debris. Patented kinetic WBC monitoring alerts the operator to the presence of osmotically fragile cells. This system generates a specific flag correlating to the types of cells found in chronic lymphocytic leukemia and other lymphoid malignancies. Increased Resolution Expands WBC Linearity CELL-DYN Sheath Reagent is formulated to eliminate stroma and debris from the optical leukocyte enumeration. This process allows the helium-neon laser to accurately count white cells in extreme leukopenic samples. Internal Validation Provides Diagnostic Superiority Internal validation of WBC Optical Count (WOC) and WBC Impedance Count (WIC) assures the correct leukocyte count is virtually always reported, even in the presence of abnormal pathology. Nuclei Resistant RBC Mode A detergent lytic agent and special resistant RBC mode minimizes interference caused by resistant red cells. This feature saves technologist time by reducing the need for manual count verification. QC Management Twenty QC files (120 points per file) are available with summary statistics and Levey-Jennings plots. In addition, moving averages with modified Westgard rules are available for system monitoring, including the differential parameters. Walk-Away Automation The optional 100-position sample loader system employs a tube-sensing mechanism that accepts the most commonly used collection tubes. At the point of aspiration, bar codes are read and tubes are sampled in their upright position. Results are matched with worklist demographics to provide a complete report.

Reticulocyte Assays With Reportable IRF Based Upon NCCLS/ICSH Methods Laboratories have long requested an automated method for retic onsuming and labor-intensive test. Abbott has based its reticulocyte assay on the NCCLS/ICSH recommended method of supravital staining technology. Red blood cells and reticulocytes are counted, sized and identified by the proprietary M.A.P.S.S. (Multi-Angle Polarized Scatter Separation) technology. Comprehensive Reticulocyte Analysis & Classification The CELL-DYN 3700 utilizes New Methylene Blue Scatter Classification 9 0 2 staining to measure the Immature Reticulocyte Fraction (IRF). Immature reticulocytes contain more RNA than mature reticulocytes. Since Polyribosomal RNA absorbs new methylene blue stain, these immature cells can be identified by 90 laser scatter. Results are graphically displayed on the CELL-DYN monitor with a threshold that clearly separates immature and mature reticulocytes. d e g 3 1 2 3 5 4 6 1 10 deg Mature RBCs Nucleated Cells Platelets The IRF is reported as a fraction or percent of the total reticulocytes. 4 5 6 Reticulocytes IRF (Immature Reticulocyte Fraction) Coincidence Unique Advantages of IRF Analysis An improved method for the classification of anemias Automated monitoring of erythropoetic activity during therapy

Multi-Dimensional Cell Classification M.A.P.S.S. (Multi-Angle Polarized Scatter Separation) technology applies a multi-step algorithm to the light scatter data to classify WBCs. Four distinct light-scattering measurements are made on each individual white blood cell (0, 10, 90 and 90 depolarized). A list of all the cells with these corresponding measurements is made; this is called List Mode Data Analysis. Up to 10,000 events are measured and stored on each patient sample. The proprietary M.A.P.S.S. technology accurately identifies five white cell sub-populations. Since white cells are diluted in a single leucoprotective reagent, they maintain their cellular integrity and are measured in their true native state. The elimination of fixatives, dyes or stains minimizes the possibility of misclassification caused by numerous dilutions and special dye channels. List Mode Data Analysis Size Complex- Lobularity Granularity Classification Cell 0 10 90 90 Depolarized 1st 2nd 3rd 1 165 162 116 32 POLY NEUT 2 60 64 15 6 MONO LYMPH 3 140 79 21 99 MONO MONO 4 148 182 104 118 POLY EOS 5 90 110 28 8 MONO BASO 6 36 37 8 4 MONO NOISE NOISE Monocyte 0 Scatter Lymphoblast Monoblast variant lymphs Myeloblast blasts myelocyte immature granulocytes Neutrophils Monocytes Basophils Lymphocytes metamyelocyte Eosinophils band bands segmented Eosinophilic segmented Lymphocyte Non-white blood cells Basophilic segmented Erythrocyte 10 Scatter

CELL-DYN 3700 Reportable CBC, Differential, Reticulocyte and Immature Reticulocyte Fraction All on One Platform SPECIFICATIONS Technology and Methods Combined impedance and M.A.P.S.S. flow cytometry 5 mw helium neon laser Hydrodynamic focusing of cell stream Dual WBC methods (WOC, WIC) WBC (WOC) and differential measurement - Light scatter analysis: 0, 10, 90, 90 depolarized WBC (WIC) measurement - Nucleated cell impedance analysis List mode data analysis up to 10,000 cells Cell-by-cell analysis with color identification Cyanide-free hemoglobinometry Complete reticulocyte analysis with IRF Resistant RBC mode for lyse-resistant red cells Processing and Aspiration CBC with auto-differential, 90 specimens per hour <240 microliters (closed mode) <130 microliters (open mode) <355 microliters (loader mode) Data Management Full on-board QC - 20 files (120 data points) - Summary statistics and Levey-Jennings plots - Moving averages (including differential) - Westgard rules 10,000 results stored with graphics Work list capability (800 entries) Programmable patient and report limits Complete patient demographics Bar code reading: Code 39, Codabar, Code 128, Interleaved 2 of 5 Auto-calibration program On-board diagnostics Operating Environment Temperature 15 C (59 F) to 30 C (86 F) Humidity 10% to 85% relative humidity, non-condensing Data Module High-speed microprocessor Hard & floppy disk drives RS232, bi-directional interface 15 SVGA color monitor Multiple language option: French, German, Italian, Japanese, Spanish Standards and Safety Compliance UL CSA IEC 1010 CE Mark CELL-DYN is a registered trademark and M.A.P.S.S. is a trademark of Abbott Laboratories. Levey-Jennings is a registered trademark of the Levey-Jennings Company. Parameters White Cells Red Cells Platelets Reticulocytes WBC# Neutrophil # & % Lymphocyte # & % Monocyte # & % Eosinophil # & % Basophil # & % *For Laboratory Use Only RBC# HGB HCT MCV MCH MCHC RDW Electrical Requirements PLT# MPV *PCT *PDW RETIC# RETIC % IRF Module Voltage Frequency Max Current Analyzer (CS) 110VAC ± 10% 3 amps Analyzer (SL) 120VAC ± 10% 220VAC ± 10% 240VAC ± 10% 3 amps 6 amps 6 amps Monitor 100-240 VAC 1.3 amps Printer 120VAC ± 10% 240VAC ± 10% System Components CELL-DYN 3700SL CELL-DYN 3700CS 0.4 amps 0.2 amps Module Height Width Depth Weight Analyzer (CS) 24" (61cm) 30" (76cm) 22" (56cm) 190 lbs (86kg) Analyzer (SL) 27" (68cm) 30" (76cm) 31" (79cm) 288 lbs (131kg) Printer 13" (33cm) 19" (48cm) 24" (61cm) 14.3 lbs (6.5kg) Abbott GmbH & Co. KG Abbott Diagnostics Europe Max-Planck-Ring 2 65205 Wiesbaden Tel. (+49) 61 22 58 0 Fax (+49) 61 22 58 12 44 www.abbottdiagnostics.com AH2104/uk Cell-Dyn 3700 07/06/x