Cordis ExoSeal. Maximise Clinical Safety*. The novel approach to secure and easy closure. Vascular Closure Device CORDIS EXOSEAL VCD

Similar documents
Maximise Clinical Safety*. Cordis ExoSeal. The novel approach to secure and easy closure. Vascular Closure Device CORDIS EXOSEAL VCD

Endovascular Catalog. Endovascular Catalog Page 1 cordis.com

Chronic Total Occlusion (CTO) Technologies. Re-open vital channels

Chronic Total Occlusion (CTO) Technologies

INTRODUCING. Cordis POWERFLEX Pro PTA Dilatation Catheter

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

Interactive Tool Box for Below The Knee selected by Max Amor & Joseph Azzi.

Pocket Reference Guide For (CTO) Technologies

Cordis EXOSEAL Vascular Closure Device

Vascular Closure Device: A to Z. Owayed M Al Shammeri, MD, FSCAI Interventional Cardiologist AlRayyan Hospital, HMG Riyadh

CLOSES WITH SECURITY. LEAVES WITHOUT A TRACE.

We Catch. What Others Miss

Cardiovascular Catalog

CAROTID ARTERY ANGIOPLASTY

Versatility and Proven Safety

Talent Abdominal Stent Graft

Straub Endovascular System &

All-In-One. Iliac Branch System. PER F ORM ANC E b y d e s i g n ILIAC BRANCH ENDOPROSTHESIS

Advanced Innovation for Exceptional Performance

REDUCE COMPLICATIONS WITH RADIAL AND FEMORAL

Cordis Closing the Wound

Endovascular Repair of Combined Occluded Femoral and Popliteal Arteries

Alternate Vascular Access for TAVR. Gian Paolo Ussia Campus Bio-medico University, Rome Italy

Instructions for Use Cordis PRECISE PRO Rx Nitinol Stent System

Clinically proven. ordering info. Vascular Intervention // Peripheral Self-Expanding Stent System/0.018 /OTW. Pulsar-18

When Outcomes Matter, Design Matters

Vascular Closure Techniques

PERFORMANCE YOU CAN TRUST. EverFlex Self-expanding Peripheral Stent with Entrust Delivery System

Appropriate Device Selection for Endovascular Procedures

Proven Performance Through Innovative Design *

FROM THE EVERYDAY TO THE EXTRAORDINARY

LOWERING THE PROFILE RAISING THE BAR

Assurant Cobalt Iliac BALLOON EXPANDABLE STENT SYSTEM

Vascular V12. Covered Stent. The New Standard of Care

How to Choose Among Carotid Embolic Protection Devices?

The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service

Cordis EXOSEAL Vascular Closure Device

Finally, the Control You Need to Deliver Accurate Treatment

Copyright HMP Communications

Access Closure: Manual vs. Device

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Copyright HMP Communications

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

Diagnosis and Management of Femoral Access Site Complications IV: Novel Techniques for Endovascular Rescue

Case Study of Implantation of a VICI VENOUS STENT - Combined NIVL and PTS Stenting

Percutaneous Intervention for totally Occluded Coarctation Of Aorta. John Jose, Vipin Kumar, Ommen K George Dept Of Cardiology

IMAGES. in PAEDIATRIC CARDIOLOGY

Optimal Filter Placement

Ancillary Components with Z-Trak Introduction System

PressureWire Aeris with Agile Tip Technology. Wireless FFR Functionality and Handles like a Workhorse PCI Guidewire 1

NC EMERGE TM PTCA Dilatation Catheter

The Art of. Flow Restoration. Ikazuchi Zero. Semi-Compliant PTCA Balloon OVERVIEW CROSSABILITY LOW PROFILE CASE STUDY CODES

Quick Reference Guide

interventional cardiology

Combine the best of both worlds

-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE

5F Devices with 0.035

Άγγελος Παπανικολάου MD, Ειδικευόμενος Καρδιολογίας, A Πανεπιστημιακή Καρδιολογική Κλινική, ΓΝΑ Ιπποκράτειο

(EU), FACC (USA), FSCAI (USA)

Mechanical Properties of the GORE TIGRIS Vascular Stent

Issam D. Moussa, MD. Professor of Medicine Mayo Clinic College of Medicine Chair, Division of Cardiovascular Diseases Mayo Clinic Jacksonville, FL

ABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM

Indications. The AngioVac cannula is intended for use as a venous drainage cannula and for the removal of fresh, soft thrombi or emboli

Max Medical Devices.

1 Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis. N Engl J Med 352;13, March 31, 2005

Guide Wires design and selection Abbott Vascular. All rights reserved.

Is a Stent or Scaffold Necessary in The SFA?

Excimer Laser for Coronary Intervention: Case Study RADIAL APPROACH: CORONARY LASER ATHERECTOMY FOR CTO OF THE LAD FOLLOWED BY PTCA NO STENTING

Micromesh technology in carotid artery treatment what is next? Max Amor MD Clinique Louis Pasteur, Essey-Les-Nancy France

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

Vascular Access: Management of Complications. Chris Burrell, South West Cardiothoracic Centre, Plymouth

CAROTID ARTERY ANGIOPLASTY

C ARDIAC INTERVENTION

Vascular Closure Techniques

Vascular Closure Techniques

EluNIR. Ridaforolimus Eluting Coronary Stent System. Advancing Deliverability for the Road Ahead

Single Pass MCA Revascularization with Trevo

My Indications are based on anatomy

New Stroke Interventions. Scott L. Zuckerman M.D. Vanderbilt Neurosurgery

12-month results of a novel large access closure device: insights from the FRONTIER II Study

TRANSRADIAL PERIPHERAL VASCULAR INTERVENTIONS

Acute dissections of the descending thoracic aorta (Debakey

TEACHING CASE # 5. Reocclusion Of Transverse And Sigmoid Venous Sinuses Mechanical and Chemical Thrombectomy

The Challenge of Accurately Stenting Aorto-Ostial Lesions

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

Turbo-Power. Laser atherectomy catheter. The standard. for ISR

Cardiva Catalyst III INSTRUCTIONS FOR USE

Challenging anatomies demand versatility.

Aspiration Mechanical Thrombectomy in AV fistula salvage

Mechanical Thrombectomy of Large Vessel Occlusions Using Stent Retriever Devices

Durable outcomes. Proven performance.

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

Shaping the future with the swirling flow stent

CORPORATE SUPPORT. AstraZeneca

Techniques for Carotid Interventon

ASDIN 10th Annual Scientific Meeting Final

Guidewire Selection. Making the Most Out of My Guidewire: LINC 2016: Leipzig Interventional Course Leipzig, Germany January 26-29, 2016

Indications for use. Contraindications within the United States

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Transcription:

Cordis ExoSeal Vascular Closure Device CORDIS EXOSEAL VCD Maximise Clinical Safety*. The novel approach to secure and easy closure. * Clinical data from the ECLIPSE Trial indicates safety in terms of vascular injury, access site-related bleeding, infection or nerve injury, new ipsilateral lower extremity ischemia or SAE. Wong et al JACC Cardiovasc Interv. 2009 Aug;2(8):785-93.

Access, Diagnose and Treat with the Complete Line of Products and Services from Cordis Since 1959, Cordis has been a leader in the market offering best-in-class access, diagnostic and treatment solutions. Over the past four decades, our product offering has grown to become one of the largest in the industry. With high performing solutions to help support sustained patient outcomes, Cordis has become the full-line partner of choice.

Why EXOSEAL? The Novel Choice. Introducing the Cordis EXOSEAL Vascular Closure Device. Combining clinical safety* and ease-of-use, the Cordis EXOSEAL Vascular Closure Device means a more confident close and improved patient outcomes. WHY EXOSEAL? Easy-to-Use Functionality Trusted Bioabsorbable Technology Precise Extravascular Closure Excellent Clinical Results* *Clinical data from the ECLIPSE Trial indicates safety in terms of vascular injury, access site-related bleeding, infection or nerve injury, new ipsilateral lower extremity ischemia or SAE. Wong et al JACC Cardiovasc Interv. 2009 Aug;2(8):785-93.

Product Features Deployment Button Lockout feature reduces risk of intravascular plug deployment. Indicator Window Provides indication of extravascular position before deployment. Sheath Adapter & Wire Loop Release Compatible with introducer sheath (sheath exchange not required).* * Minimises chance of infection and inflammation > Maximises patient comfort. Cordis EXOSEAL Closure Device provides **Compatible with sheaths up to 12 cm. Please consult IFU for further details.

Cordis EXOSEAL Vascular Closure Device Maximise Clinical Safety* in Closure Designed for accurate placement, secure extravascular deployment and reduced complication rates.* Bleed-Back System Provides visual indicator for secure extravascular plug deployment. PRODUCT FEATURES Indicator Wire Nitinol indicator wire provides gentle and precise feedback to ensure extravascular plug placement. precise and secure extravascular arterial closure. *Clinical data from the ECLIPSE Trial indicates safety in terms of vascular injury, access site-related bleeding, infection or nerve injury, new ipsilateral lower extremity ischemia or SAE. Wong et al JACC Cardiovasc Interv. 2009 Aug;2(8):785-93.

Bioabsorbable Technology Clinically Safe * and Trusted, Synthetic Plug Closure The Cordis EXOSEAL Vascular Closure Device uses a Polyglycolic Acid (PGA) plug material to securely close the femoral artery puncture site while causing low tissue reactivity to minimise access site complications*. *Clinical data from the ECLIPSE Trial indicates safety in terms of vascular injury, access site-related bleeding, infection or nerve injury, new ipsilateral lower extremity ischemia or SAE. Wong et al JACC Cardiovasc Interv. 2009 Aug;2(8):785-93.

Plug Absorption Characteristics PGA plug material absorption and tissue reaction assessment in rat gluteal model 1 3 Days 14 Days 60 Days Effective Why a PGA Plug is Safe * : PGA has a long history in medical use PGA is not made from animal tissue Fully resorbed within 60-90 days BIOABSORBABLE 1 Data on file at Cordis *Clinical data from the ECLIPSE Trial indicates safety in terms of vascular injury, access site-related bleeding, infection or nerve injury, new ipsilateral lower extremity ischemia or SAE. Wong et al JACC Cardiovasc Interv. 2009 Aug;2(8):785-93.

Extravascular Positioning Secure Extravascular Closure Confident, extravascular positioning of bioabsorbable plug Plug is held securely in place by surrounding tissue

Secure and Precise Extravascular Placement Eliminates any possibility of intravascular deployment Deploys haemostatic plug without impeding arterial blood flow Provides two visual signals to increase operator confidence and patient comfort BLACK-WHITE Device not yet positioned to deploy. Lockout feature activated. BLACK-BLACK Deploy, if significantly reduced bleed-back is also seen from bleed-back window. BLACK-RED Release slight tension on device until window shows Black-Black. Otherwise switch to manual compression. EXTRAVASCULAR

The Partner of Choice from Stick to Seal Cardiovascular Emboli protection device ANGIOGUARD RX Emboli Capture Guidewire System Guiding catheters Long VISTA BRITE TIP Guiding Catheter VISTA BRITE TIP Guiding Catheter ADROIT Guiding Catheter Steerable guidewires ATW Guidewire ATW MW Guidewire REFLEX Steerable Guidewire SHINOBI PLUS Steerable Guidewire SHINOBI Steerable Guidewire STABILIZER Balance Performance Steerable Guidewire STABILIZER MW Steerable Guidewire WIZDOM Steerable Guidewire Balloons EMPIRA Balloons Catheters EMPIRA NC Balloons Catheters Catheter sheath introducers AVANTI + Sheath Introducer Diagnostic catheters 7F HIGH FLOW INFINITI Catheters QUICK CARE 4F INFINITI Catheters SUPERTORQUE Plus Catheters Diagnostic guidewires EMERALD Diagnostic Guidewire Endovascular Catheter sheath introducers AVANTI + Sheath Introducer BRITE TIP Interventional Sheath Introducer CTO catheters FRONTRUNNER XP CTO Catheter OUTBACK LTD Re-entry Catheter Diagnostic catheters NYLEX Angiographic Catheter SUPER TORQUE Angiographic Catheter SUPER TORQUE MB Angiographic Catheter TEMPO Angiographic Catheter TEMPO AQUA Hydrophilic-Coated Angiographic Catheter Diagnostic guidewires EMERALD Guidewire Emboli protection device ANGIOGUARD RX Emboli Capture Guidewire System Guiding catheters VISTA BRITE TIP Guiding Catheter VISTA BRITE TIP IG Introducer Guiding Catheter Pre-mounted balloon expandable stents.014 PALMAZ BLUE 0.14 Peripheral Stent.018 PALMAZ GENESIS Peripheral Stent on SLALOM Delivery System.018 PALMAZ BLUE 0.18 Peripheral Stent.035 PALMAZ GENESIS Peripheral Stent on OPTA Pro.035 Delivery System PTA balloons.014 RX AVIATOR Plus PTA Balloon Dilatation Catheter.014 RX SLEEK PTA Balloon Dilatation Catheter.018 OTW SAVVY Long PTA Balloon Dilatation Catheter.018 OTW SAVVY PTA Balloon Dilatation Catheter.018 OTW SLALOM PTA Balloon Dilatation Catheter.035 OTW MAXI LD PTA Balloon Dilatation Catheter.035 POWERFLEX Pro PTA Balloon Catheter.035 OTW POWERFLEX Extreme PTA Balloon Dilatation Catheter Self-expanding stents.014 PRECISE PRO RX Nitinol Stent System.035 Long S.M.A.R.T. Nitinol Stent System.035 S.M.A.R.T. CONTROL LARGE Nitinol Stent System.035 S.M.A.R.T. CONTROL Nitinol Stent System S.M.A.R.T. Flex Vascular Stent Steerable guidewires.014 ATW Steerable Guidewire.014 STABILIZER Peripheral Steerable Guidewire.018 SV Steerable Guidewire.035 AQUATRACK Hydrophilic Nitinol Guidewire.035 JINDO Tapered Steerable Guidewire.035 STORQ Steerable Guidewire Unmounted balloon expandable stents PALMAZ GENESIS Peripheral Stent PALMAZ XL Balloon Expandable Stent for Large Vessels Venous products OPTEASE Retrievable Vena Cava Filter TRAPEASE Permanent Vena Cava Filter

Cordis EXOSEAL Vascular Closure Device For clinically safe*, confident close resulting in improved patient outcomes, use the Cordis EXOSEAL Vascular Closure Device Easy-to-Use Functionality Trusted Bioabsorbable Technology Precise Extravascular Closure Excellent Clinical Results* *Clinical data from the ECLIPSE Trial indicates safety in terms of vascular injury, access site-related bleeding, infection or nerve injury, new ipsilateral lower extremity ischemia or SA Wong et al JACC Cardiovasc Interv. 2009 Aug;2(8):785-93. E.

Products Providing a broad range of quality and innovative products to make a real difference in the minimally invasive treatment of cardiac and vascular disease. Services Supporting interventionalists and cathlab personnel by offering a full range of educational services through the Cordis Cardiac and Vascular Institute (CCVI). Outcomes Changing the lives of patients by being committed to evidence based medicine with the largest body of clinical evidence. This means maintaining an unwavering commitment to helping change the face of circulatory disease management. Today, tomorrow and into the future, we re devoted to our strong partnership with you, while consistently creating leading-edge products that will benefit the industry. Important Information: Prior to use, refer to the instructions for use supplied with these devices for indications, contraindications, side effects, suggested procedure, warnings and precautions. As part of the Cordis policy of continuous product development we reserve the right to change product specifications without prior notification. Tel:+32 2 746 30 00 Fax:+32 2 746 34 05 Johnson & Johnson Medical NV/SA 2013 EU302 August 2013 2E-800-1697-4