SENSATION and CS300 Smaller meets faster. IABP System

Similar documents
LINEAR 7.5Fr. IAB Catheter

LINEAR. 7.5Fr. IAB Catheter. This document is intended to provide information to an international audience outside of the US.

HLS Cannulae Solutions from tip to tip.

HLS Cannulae Solutions from tip to tip.

HLS CANNULAE SOLUTIONS FROM TIP TO TIP

Arrow AC3 Optimus Intra-Aortic Balloon Pump Greater precision with increased simplicity; an evolution in IABP performance

Arrow AC3 Optimus Intra-Aortic Balloon Pump Greater precision with increased simplicity; an evolution in IABP performance

CLINICAL SUPPORT SERVICES DEVELOPING AN IABP PRECEPTOR STRATEGY

IABP Timing & Fidelity. Pocket Reference Guide

CLAMPLESS BEATING HEART SURGERY PRODUCT FAMILY

Extracorporeal Circuit Cannulae { VENOUS}

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

LINEAR. 7.5Fr. IAB CATHETER INSTRUCTIONS FOR USE. INSTRUCTIONS FOR USE LINEAR 7.5Fr. Intra-Aortic Balloon Catheter 1

ER REBOA Catheter. Instructions for Use

Directions For Use. All directions should be read before use

The next step in dialysis catheter technology

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

DC-40 Ultrasound System. powerful efficient sleek

A GUIDE TO OUR NIBP TECHNOLOGY

Defibrillators TEC-8300K series. It s all seamless

XEMEX IABP Balloon Plus

Cardioplegia Circuit Products { CARDIOPLEGIA ADAPTERS}

Altrix Precision Temperature Management System. Simple. Safe. Efficient.

An intermittent catheter you can BELIEVE in. magic. INTERMITTENT CATHETER with m3 technology

Section 6 Intra Aortic Balloon Pump

Advanced Innovation for Exceptional Performance

ROTABLATORTM. Peripheral. Rotational Atherectomy System. Quick Reference Cards

arrow nextstep antegrade & Arrow Edge The next step in dialysis catheter technology

THE journal OF EXTRA-CORPOREAL TECHNOLOGY ABSTRACT

Polyurethane Dual Lumen Occlusion Catheter English Instructions for Use. Polyurethane Dual Lumen Occlusion Catheter

Extended Dwell Catheter Product Offerings. Providing optimal outcomes for long-term and intermediate therapies

Cardioplegia Circuit Products { ANTEGRADE}

Driving performance, delivering versatility. Spetzler -Malis and SILVERGlide Non-Stick Bipolar Forceps

One intelligent solution

PRESS RELEASE THE NEW SPECIAL-PURPOSE OPERATING TABLE FOR PRECISION SURGERY IN ORTHOPEDICS, TRAUMATOLOGY AND NEUROSURGERY: THE YUNO OTN

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Device Preparation (all steps to be performed per standard interventional technique)

Rock your practice with digital restorations in a day.

Atrium Advanta V12. Balloon Expandable Covered Stents

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

Global Myocardial Protection

NIRxcell CoCr Coronary Stent System

Advancing Lives and the Delivery of Health Care. The High-Flow Port Designed for Apheresis

Directions For Use. All directions should be read before use. Page 1 of 8

LeMaitre Embolectomy Catheter

URGENT FIELD SAFETY NOTICE MEDICAL DEVICE FIELD CORRECTION Maquet/Datascope CARDIOSAVE Intra-Aortic Balloon Pump (IABP)

61% SvO 2. Clarity. Simplified.

TurboHawk. Plaque Excision System

FIND YOUR IDEAL CANNULAE CATALOG. Designed for your smallest patients

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

Defibrillators TEC-8300K series. Improving quality of resuscitation

powerful versatile mobile

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

Changing the Way Performance is Measured

ConforMIS, Inc. 28 Crosby Drive Bedford, MA Phone: Fax:

PressureWire Aeris with Agile Tip Technology. Wireless FFR Functionality and Handles like a Workhorse PCI Guidewire 1

Safe, simple and reliable closed blood sampling for effective patient blood management.9,14

Automated Blood Pressure Monitor

Indications. The AngioVac cannula is intended for use as a venous drainage cannula and for the removal of fresh, soft thrombi or emboli

Integra. Limit uncertainty by simplifying operation and maximizing performance with NXT Digital Architecture

HDiag 37 - Vascular Assist 03 27/4/07 17:11 Page 1. Vascular Assessment Systems and Electronic Patient Record Software. DIAGNOSTIC Products Division

Graft Delivery Devices

How to Record & Send Information

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Peel-Apart Percutaneous Introducer Kits for

MARS Ambulatory ECG Analysis The power to assess and predict

AXS Catalyst Distal Access Catheter

Product specifications Mattress replacement alpha active 4 Mattress replacement Pump GetinGe GrouP arjohuntleigh GetinGe MaQuet arjohuntleigh

Welch Allyn HScribe Holter Analysis System

Speed - Accuracy - Exploration. Pathfinder SL

JETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW

Data Collection Worksheet

Safe-T-Centesis catheter drainage system. Innovations in patient safety, clinician safety and procedural efficacy.

i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE

One intelligent solution

Pruitt Irrigation Occlusion Catheter. English Instructions for Use. Pruitt Irrigation Occlusion Catheter

Balloon in Balloon (BIB )

Arrow-Clark VectorFlow Hemodialysis Catheter Because in Chronic Hemodialysis Catheters, the Tip Matters

High Flow Family. Short Term Dialysis Catheters. Dialysis

Ruby Coil. Large Volume Detachable Coils

SedLine Sedation Monitor

SYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only

Combine the best of both worlds

CARDIOVIT CS-200 Excellence. Designed for high-volume workload, equipped with the latest technology to save time and boost productivity

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

A SIMPLE SOLUTION FOR CARDIAC MONITORING

Integra Flowable Wound Matrix

The Art of. Flow Restoration. Ikazuchi Zero. Semi-Compliant PTCA Balloon OVERVIEW CROSSABILITY LOW PROFILE CASE STUDY CODES

22F coil-reinforced cannula. Designed with a balloon actuated, expandable funnel shaped distal tip

Sleep Apnea Therapy Software User Manual

X Series Extensive Capabilities

Biomedical Instrumentation E. Blood Pressure

BARD LATEX FOLEY CATHETERS. Together, advancing the world of health. Utilization. Insertion. Maintenance. Duration

BP-600 Noninvasive Blood Pressure Sensor

TrueSight Personalized Planning & Targeting System. Operative technique

CLARIVEIN INFUSION CATHETER

BETTER WOUND CARE. BETTER OUTCOMES.

Rhinology Products. Rhinology Products. Superior solutions for superior patient care.

Peripheral Intravascular Lithotripsy (IVL) Catheter Instructions for Use (IFU)

Transcription:

SENSATION and CS300 Smaller meets faster IABP System

Cardiac Assist SENSATION and CS300 3

Cardiac Assist SENSATION and CS300 5 Smaller The SENSATION 7Fr. Fiber-Optic IAB Catheter Faster The CS300 with INTELLISENSE Optimal Therapy for all IABP Patients Smaller is better SENSATION 7Fr.: The smallest IAB catheter available today combined with innovative, fiber-optic technology that automatically calibrates in vivo. Smaller is better for the patient, potentially reducing vascular complications. Arterial lumen 8Fr. IABs 7.5Fr. IABs Linear 7.5Fr Catheter Increased space for distal flow Sensation 7Fr. Drawing not to scale Faster Balloon pump system CS300: The CS300 with IntelliSense combines fiber-optic speed with automatic in vivo calibration. The result is faster time to therapy, faster signal acquisition, and faster adaptation to rate and rhythm changes. 1998 System 98 2000 System 98XT 2003 CS100 2007 CS300

6 SENSATION and CS300 Cardiac Assist SENSATION 7Fr. Smaller and faster is better for the patient and clinician 7Fr. size without sacrificing performance: The 7Fr. catheter is made possible by fiber-optic technology, allowing more patients with smaller, compromised vessels to benefit from IABP therapy. Potential for smaller arteriotomy Potential for reduced limb ischemia 7Fr. catheter allows: 13% increase in the amount of distal flow vs. 8Fr. * 23% reduction on catheter cross-sectional area Percentage of Flow Distal to Lab Insertion Site* 7Fr. and 8Fr. IAB Catheters Simulated Femoral Artery (diameter) 4.0mm 8Fr. IAB Catheter 7Fr. IAB Catheter 51.2 63.8 0 20 40 60 80 % of Normal Flow *Ohley (theoretical model) on file Proprietary IAB Membrane Membrane: A patented, blowmolded polyurethane IAB material created to stand up to your most difficult patients Abrasion resistance improved 43% Improved fatigue resistance Immediate inflation at start-up Reduced insertion force Abrasion Resistance 1 SENSATION 7Fr. Membrane 43% better than Cardiothane II 4.5 4 3.5 3 2.5 2 1.5 1 0.5 Proprietary IAB Membrane Competitor Cardiothane TM II

Cardiac Assist SENSATION and CS300 7 The fiber-optic sensor instantaneously transmits a precise pressure signal to the CS300: Reduced signal transfer delay vs. fluid-filled column Maximizes helium gas shuttle lumen Speeds and standardizes pressure set-up (plug & play) Advanced tip design and reduced signal artifact Provides a clean, crisp arterial pressure waveform Arterial pressure waveform not affected by electrosurgical interference or patient movement and positioning New IAB tray and insertion kit packaging: Innovative tray design for faster, easier set-up and improved membrane Sensor window Balloon membrane (shown inflated) protection Sensor face cavity (filled with silicone gel) Sensor fiber The unique T-handle balloon retainer: Ensures smallest balloon membrane profile Protects balloon membrane during set-up Sensor Radiopaque marker Molded tip Inner lumen tubing (polyimide) Unique T-handle Graphic representation of catheter Drawing not to scale

Cardiac Assist SENSATION and CS300 9 CS300 IABP A Smart and Flexible Pump Faster is better for the patient and clinician Faster time to therapy: CS300 has true one-button start-up. Simply push one button to initiate therapy. Automatically calibrates the fiber-optic pressure sensor in the patient and recalibrates every 2 hours or sooner should patient or environmental conditions change Automatically evaluates and selects the best lead and trigger source Automatically sets optimal timing Automatically adjusts to changes in patient conditions without clinician intervention Faster inflation and deflation speed: The combination of a fast balloon pump and a superior catheter result in a fast inflate/deflate time. Speed matters! For the patient, the benefit is an improvement in arrhythmia tracking and response. A smart timing algorithm matters: The CS300 with IntelliSense is designed to emulate an experienced user, allowing the clinician more time to focus on the patient. The CS300 regularly examines key landmarks on the ECG and arterial pressure waveform to determine optimal timing. It then quickly adapts to rate or rhythm changes instead of imposing fixed timing rules. One-button start-up R-Trac is a patented surveillance algorithm that quickly identifies unpredictable rhythms such as A-Fib. Once identified, R-Trac adjusts timing on a beat-to-beat basis in order to optimize augmentation and support during diastole. Flexibility matters. The CS300 has the ability to adjust all timing parameters to patient s changing needs. The CS300 is the only pump that can be used with any of the catheters mentioned below: The SENSATION 7Fr. fiber-optic IAB catheter Conventional fluid-filled IAB catheters Pediatric IAB catheters Smart and flexible to meet the needs of your patients.

10 SENSATION and CS300 Cardiac Assist SENSATION 7Fr. and CS300 IABP Unique Features Fiber-optic pressure signal transmission to a patient monitor: An electrically isolated, low-level pressure output from the CS300 enables clinicians to send the fiber-optic arterial pressure waveform directly to a patient monitor by simply attaching an appropriate cable. Unique automatic in vivo calibration: Maquet has the ONLY fiber-optic IABP and catheter system that automatically calibrates in the patient after insertion and automatically recalibrates in vivo every 2 hours or sooner should patient or environmental conditions change. Low-level pressure output allows direct connection to a patient monitor The result: Faster time to therapy, ongoing consistency and accuracy of the arterial blood pressure waveform, and improved ease of use. In vivo Calibration Fiber-optic pressure waveform at insertion, prior to calibration Pressure (mmhg) 120 110 100 90 80 70 60 50 After calibration, fiberoptic pressure waveform matches reference pressure waveform 40 0 2 4 6 8 10 12 14 16 18 Time in seconds The in vivo calibration gives you the confidence that the fiber-optic pressure waveform is consistently accurate 1 Fiber-optic Millar

Cardiac Assist SENSATION and CS300 11 Smaller, faster, smarter, easier Optimal therapy for all IABP patients Integrated IV pole Fiber-optic sensor module Detail of fiber-optic sensor connector from SENSATION IAB Electrically isolated, lowlevel fiber-optic pressure output Rubber helium tank knob Easy access helium tank Data output port: allows connection to clinical information systems

12 SENSATION and CS300 Cardiac Assist Customized Solutions Extensive portfolio of clinical support services: Real-time remote access via WIN-IABP modem connection A variety of clinical education programs designed to maximize staff time, increase confidence and improve productivity Accredited programs for physicians and nurses Extensive library of educational materials to meet the needs of providers as well as patients Technical Services protect investment: Emergency Service available Preventative Maintenance Programs Telephone Technical Support Extended Warranty & Service Agreements Loaner & Rental IABP Programs Maquet Field Service Representatives provide rapid response for all your IABP service requests

Maquet 1300 MacArthur Blvd., Mahwah, NJ 07430, USA Phone: +1 201 995 8700 or 1 800 777 4222 Maquet Medical Systems USA 45 Barbour Pond Drive, Wayne, NJ 07470, USA Phone: 1 888 880 2874 www.maquet.com http://ca.maquet.com Getinge Group is a leading global provider of products and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences. We operate under the three brands of ArjoHuntleigh, Getinge and Maquet. ArjoHuntleigh focuses on patient mobility and wound management solutions. Getinge provides solutions for infection control within healthcare and contamination prevention within life sciences.maquet specializes in solutions, therapies and products for surgical interventions, interventional cardiology and intensive care. PN: 0002-08-0845 Rev A Maquet is a registered trademark of Maquet GmbH SENSATION is a U.S. registered tradedmark of Datascope Trademark Corp. CS300 and INTELLISENSE are trademarks of Datascope Trademark Corp. Copyright 2014 Datascope Corp. or its affiliates. All rights reserved. 10/14 Caution: Federal (U.S.A.) Law restricts this device to sale by or on the order of a physician. Refer to Instructions for Use for current indications, warnings, contraindications, and precautions. 1 Data on file MCV00012635 Rev B