A High Sensitivity UPLC/MS/MS Method for the Analysis of Clopidogrel and Clopidogrel Carboxylic Acid Metabolite in Human K 2 EDTA Plasma

Similar documents
Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

Quantification of Budesonide Using UPLC and Xevo TQ-S

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology

Reducing Sample Volume and Increasing Sensitivity for the Quantification of Human Insulin and 5 Analogs in Human Plasma Using ionkey/ms

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology

Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Challenges in Developing an Ultra-Sensitive Bioanalytical Method for Ethinylestradiol in Human Plasma

[ APPLICATION NOTE ] Oasis PRiME HLB Cartridge for Cleanup of Infant Formula Extracts Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis

Development of a High Sensitivity SPE-LC-MS/MS Assay for the Quantification of Glucagon in Human Plasma Using the ionkey/ms System

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE)

USP Method Transfer of Ziprasidone HCl from HPLC to UPLC

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Simultaneous Analysis of Intact Human Insulin and Five Analogs in Human Plasma Using μelution SPE and a CORTECS UPLC Column

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

[ APPLICATION NOTE ] UPLC-MS/MS Analysis of 45 Amino Acids Using the Kairos Amino Acid Kit for Biomedical Research INTRODUCTION APPLICATION BENEFITS

Comparison of a UPLC Method across Multiple UHPLC Systems

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk

Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection

John Haselden 1, Gordon Dear 1, Jennifer H. Granger 2, and Robert S. Plumb 2. 1GlaxoSmithKline, Ware, UK; 2 Waters Corporation, Milford, MA, USA

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK

Dienes Derivatization MaxSpec Kit

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

A UPLC/MS Approach for the Diagnosis of Inborn Errors of Metabolism

The Application of UPLC/MS E for the Analysis of Bile Acids in Biological Fluids

Detection of Cotinine and 3- hydroxycotine in Smokers Urine

A RAPID AND SENSITIVE UPLC/UV/MS METHOD FOR SIMVASTATIN AND LOVA S TAT IN IN SU P P O RT O F C L E A NING VA L I DAT IO N S T U DIES

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System.

GlycoWorks Sample Preparation Consumables

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system

Profiling Flavonoid Isomers in Highly Complex Citrus Juice Samples Using UPLC Ion Mobility Time-of-Flight Mass Spectrometry

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

UPLC/MS/MS Method for the Routine Quantification of Regulated and Non-Regulated Lipophilic Marine Biotoxins in Shellfish

A Metabolomics Approach to Profile Novel Chemical Markers for Identification and Authentification of Terminalia Species

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

[ APPLICATION NOTE ] A Generic Kit-Based Approach for LC-MS/MS Quantification of Urinary Albumin for Clinical Research APPLICATION BENEFITS

Jody Dunstan, 1 Antonietta Gledhill, 1 Ailsa Hall, 2 Patrick Miller, 2 Christian Ramp 3. Waters Corporation, Manchester, UK 2

Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 )

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

Analysis of N-Linked Glycans from Coagulation Factor IX, Recombinant and Plasma Derived, Using HILIC UPLC/FLR/QTof MS

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Performance of an ultra low elution volume 96-well plate

Abstract. Introduction

Profiling and Quantitation of Metabolomic Signatures for Breast Cancer Cell Progression

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Summary Chapter 8 CHAPTER 8. Summary. Page 173

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Rapid Quantitative Analysis of Cannabidiol from Consumer Products Using UltraPerformance Convergence Chromatography

Determination of Clarithromycin in Human Plasma by LC-EI Tandem Mass Spectrometry: Application to Bioequivalence Study

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Title: Pharmacokinetics of daikenchuto, a traditional Japanese medicine (Kampo) after. single oral administration to healthy Japanese volunteers

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

PosterREPRINT SIMULTANEOUS QUANTIFICATION OF PSYCHOTHERAPEUTIC DRUGS IN HUMAN PLASMA BY TANDEM MASS SPECTROMETRY

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

LC-MS/MS Method for the Determination of Raloxifene and its Glucuronide Metabolites from Human Plasma Using SPE Micro Elution

[ APPLICATION NOTE ] The Separation of 8 -THC, 9 -THC, and Their Enantiomers by UPC 2 Using Trefoil Chiral Columns INTRODUCTION APPLICATION BENEFITS

The setup and validation of an LC-MS/MS assay of Androstenedione & Testosterone a labs experience

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

Supporting Information

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

[Application Note] TOXICOLOGY SCREENING BY UPLC/PDA IN COMBINATION WITH AN EXTENSIVE COMPOUND LIBRARY

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis

High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

[ application note note ] ]

Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS

Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS

Author. Introduction. Small Molecule Pharmaceuticals & Generics

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

Lipid Class Separation Using UPC 2 /MS

Application Note. Author. Abstract. Introduction. Food Safety

Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID

Transcription:

A High Sensitivity UPLC/MS/MS Method for the Analysis of Clopidogrel and Clopidogrel Carboxylic Acid Metabolite in Human K 2 EDTA Plasma Jennifer L. Simeone, Paul D. Rainville, Robert S. Plumb Waters Corporation, Milford, Mass., USA A P P L I C AT ION B E N E F I T S A high-sensitivity method for the analysis of clopidogrel and its carboxylic metabolite was developed using solid-phase extraction along with UPLC/MS/MS that achieved an LLOQ of 1 pg/ml in human plasma. INT RO DU C T ION Clopidogrel (trade name Plavix, Figure 1), is a thienopyridine derivative antiplatelet prodrug used in the prevention of artherosclerotic events. It is dosed in an inactive form, and requires a hepatic biotransformation to yield the active thiol-metabolite which binds to cell receptor P2Y12, irreversibly inhibiting the platelet activation process. 1 In addition to the active metabolite, an inactive carboxylic acid metabolite is also formed. This acid metabolite accounts for the majority of circulating clopidogrel related material with very low levels of the active metabolite and unchanged prodrug being present. 2,3 Due to the reactivity of the thiol metabolite, coupled with the low levels of the unchanged prodrug, most quantitative studies are based on the circulating levels of the inactive metabolite. The ability to detect the low levels of unchanged prodrug will provide more accurate data on the pharmacokinetics of clopidogrel, allowing improved evaluation of the bioavailability of new formulations. Most published methods for the analysis of clopidogrel/metabolite employ a liquid-liquid extraction (LLE) technique, often times requiring a double LLE prior to LC/MS. 3,4 This method is both time consuming and tedious and often requires large volumes of harmful chemicals, such as hexane and diethyl ether. WAT E R S SO LU T IONS Regulated Bioanalysis System Solution UNIFI Scientific Information System To address this issue the use of solid-phase μelution technology was investigated, with the aim to increase throughput while decreasing solvent consumption. A typical LLE will consume anywhere from 2 to 8 ml of organic solvent per sample, in contrast to µelution methods that require less than 0.5 ml of organic solvent. The use of µelution plates also allows the sample to be concentrated during the extraction process which facilitates lower detection limits. In this application note, we present a high-sensitivity method for the analysis of clopidogrel and clopidogrel carboxylic acid metabolite from human plasma using UPLC/MS/MS. K E Y W O R D S Clopidogrel, clopidogrel carboxylic acid metabolite 1

E X P E R IM E N TA L UPLC conditions LC system: Waters ACQUITY UPLC System LC column: Flow rate: Waters ACQUITY UPLC BEH C 18 1.7-µm, 1.0 x 50 mm 140 µl/min Figure 1. Chemical structure of clopidogrel and carboxylic metabolite. Column temp.: 45 C Mobile phase A: 0.1% Formic acid SAM P L E P R E PA R AT ION Mobile phase B: Gradient: MS conditions MS System: MS/MS Parameters: Ionization: Capillary voltage: Collision energies: Cone voltage: Acetonitrile 10% B hold for 0.5 min 10 to 90% B from 0.5 to 3 min Waters Xevo TQ-S equipped with a low flow probe for use with 1.0-mm I.D. columns Transitions: Clopidogrel 322.1 > 212.0 d4-clopidogrel 326.1 > 216.1 Clopidogrel metabolite 308.1 > 198.1 d4-clopidogrel metabolite 312.1 > 202.1 Positive ion ESI 0.5 kv 16 V 35 V Solid phase extraction Plasma samples were extracted by diluting 350 µl of plasma sample, containing 10 µl of internal standard solution at a concentration of 250 pg/ml, with 350 µl of aqueous 2% formic acid. Samples were added to an Oasis HLB µelution plate, after pre-conditioning the plate with methanol (200 µl) followed by water (200 µl). Samples were drawn through under vacuum, and then washed with 2% formic acid (200 µl) and 5% methanol/water (200 µl). The sample was eluted with 2 x 25 µl of methanol, and then diluted with an equal volume of water prior to injection. Samples were prepared at the following concentrations: 1.00, 2.50, 5.00, 10.0, 25.0, 50.0, 100, 250, and 500 pg/ml. Data integration and calculation software Waters UNIFI Scientific Information System 2

R E SU LT S A N D D IS C U S S ION The resulting chromatograms obtained for standards clopidogrel and clopidogrel carboxylic acid, as well as the internal standards d 4 -clopidgrel and d 4 -clopidogrel carboxylic acid are shown in Figure 2. Figure 2. Example chromatograms of clopidogrel (top left), deuterated clopidogrel (bottom left), carboxylic acid metabolite (top right) and deuterated carboxylic acid metabolite (bottom right). The metabolite and deuterated internal standard elute at 1.7 min, while clopidogrel and its internal standard elute at 2.8 min. The calibration curve was linear over the range of 1 to 500 pg/ml, with no carryover present (Figures 3 to 5). The use of µelution technology along with a 1.0-mm I.D. column gave a lower limit of quantification (LLOQ) of 1 pg/ml for both clopidogrel and its metabolite. The use of microbore chromatography is known to give increases in sensitivity of up to four-fold over that obtained with a standard 2.1-mm column. Clopidogrel showed a signal-to-noise value of 7:1 while the metabolite showed signal-to-noise value of 5:1 (Figure 6). Quality control (QC) samples were injected in replicates of five at four different levels spanning the range of the calibration curve. All QCs met acceptance criteria of accuracy/precision ± 20% for the LLOQ and accuracy precision ± 15% for all QC levels (Table 1). 3

Figure 3. Calibration line for clopidogrel from 1 to 500 pg/ml. Figure 4. Calibration line for clopidogrel carboxylic acid metabolite from 1 to 500 pg/ml. Figure 5. No detectable carryover was observed for both clopidogrel (ULOQ top left, blank bottom left) and the carboxylic acid metabolite (ULOQ top right, blank bottom right). 4

Figure 6. Signal-to-noise values for clopidogrel and carboxylic acid metabolite. Table 1. QC statistical data for QC levels at LLOQ, Low, Mid, and High values. Figure 7. Chromatographic resolution of clopidogrel and carboxylic metabolite from choline-containing phospholipids. 5

Another essential part of method reliability and robustness is the ability to separate the analyte(s) of interest from any background interferences. The most common interferences encountered in bioanalysis are phospholipids, which can be especially problematic for late eluting compounds, such as clopidogrel. To determine if phospholipids would coelute with the drug and metabolite, the generic 184 >184 transition was monitored (Figure 7). As can be seen from the chromatogram, clopidogrel elutes in between two major regions of interferences while the metabolite elutes over a minute before any of the phospholipids. References 1. J-M. Pereillo, M. Maftouh, A. Andrieu, M-F. Uzabiaga, O. Fedeli, P. Savi, M. Pascal, J-M. Herbert, J-P. Maffrand, C. Picard, Drug Metabolism and Disposition 30 (2002) 1288-1295. 2. A. Robinson, J. Hillis, C. Neal, A.C. Leary, Journal of Chromatogr. B 848 (2007) 344-354. 3. J-J. Zou, H-W Fan, D-Q Guo, Y-B. Li, S. Lin, Y-B Zhu, C-X. Yu, J. Zhou, J-H. Liu, Y-F Hu, Chromatographia 70 (2009) 1581-1586. 4. M. El Sadek, S. Moustafa, H. Kadi, A. Moneim, A. Al-Hakami, American Journal of Analytical Chemistry 2 (2011) 447-455. C O N C LUSIONS A high-sensitivity method for the analysis of clopidogrel and its carboxylic metabolite was developed with an LLOQ of 1 pg/ml Quality Control (QC) samples meet required acceptance criteria put forth by the U.S. FDA Both clopidogrel and the carboxylic acid metabolite were successfully separated from possible coeluting phospholipids There was no detectable carryover present Waters, ACQUITY UPLC, Oasis, and Xevo are registered trademarks of Waters Corporation. UNIFI and The Science of What s Possible are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2012 Waters Corporation. Produced in the U.S.A. March 2012 720004285en AG-PDF Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com