A Closer Look Product Education at a glance

Similar documents
A Closer Look. LATITUDE NXT Alerts SUMMARY. Alerts. Red Alerts

LATITUDE Patient Management System

CLINICAL SUMMARY COGENT-4 FIELD FOLLOWING STUDY

Tech Corner. ATP in the Fast VT zone

COGNIS. Specifications. COGNIS: Model N119 ZIP TELEMETRY CARDIAC RESYNCHRONIZATION THERAPY

SVT Discriminators. Definition of SVT Discrimination. Identify which patient populations might benefit from these features

Accessing Battery Information. Status symbol. Figure 1. Summary Dialog screen. Figure 2. Battery Status screen of a TELIGEN ICD 1

Tachyarrhythmia Suspicion and Detection

Size (mm) (H W D) Mass (g) Volume (cc)

NEIL CISPER TECHNICAL FIELD ENGINEER ICD/CRTD BASICS

ICD: Basics, Programming and Trouble-shooting

The Nuts and Bolts of ICD Therapy

Advanced ICD Concepts

Supplemental Material

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

Diagnostic capabilities of the implantable therapeutic systems

PARAD/PARAD+ : P and R Based Arrhythmia Detection

ICD Discrimination Algorithms

ICD Diagnostics: Making the most of it

Device Interrogation- Pacemakers, ICD and Loop Recorders. Dulce Obias-Manno, RN, MHSA, CCDS,CEPS, FHRS Device Clinic Coordinator, MHVI

GDT1000 SENSING ACUTE STUDY

Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

HRC Carole Joyce. Bradford Royal Infirmary. Senior Chief Cardiac Physiologist. Pacing & Invasive Services.

MADIT Studies: CRT in the Non-LBBB Patient and Other Findings. Arthur J. Moss, MD

UnitedHealthcare Medicare Advantage Cardiology Prior Authorization Program

AUTOGEN ELICD, AUTOGEN MINIICD, DYNAGEN EL ICD, DYNAGEN MINI ICD, INOGEN EL ICD, INOGEN MINI ICD, ORIGEN EL ICD, ORIGEN MINI ICD,

12 th International Winter Arrhythmia School Collingwood, Ontario February 7, Dr. Derek Yung. MD, FRCPC

A Closer Look. LATITUDE TM NXT Alerts SUMMARY. Alerts. Red Alerts

Dual-Chamber Implantable Cardioverter-Defibrillator

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

CONSULTA CRT-P Model C4TR01

Programming of Bradycardic Parameters. C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany

Programming Manual for MRI Protection Mode

The text conventions discussed below are used throughout this manual.

Protocol. This trial protocol has been provided by the authors to give readers additional information about their work.

Interactive Simulator for Evaluating the Detection Algorithms of Implantable Defibrillators

LONGITUDINAL SURVEILLANCE REGISTRY OF ACUITY SPIRAL LEAD

A New Dual Chamber Cardioverter-Defibrillator with Left Atrial Pacing Support

Top 5 Things to Know about Pacemakers and ICD s. Jeffrey S. Osborn, M.D., C.C.D.S. March 4, 2017.

Check for the presence of blood or body fluids on the lead terminal/electrode tip and in header ports. Clean as necessary with sterile water.

NEED A DEFIBRILLATOR? NOW YOU HAVE OPTIONS.

Supplementary Online Content

VISIONIST VISIONIST X4 VALITUDE VALITUDE X4 INLIVEN INTUA INVIVE

Introduction. CLINICAL RESEARCH Clinical Trial Design. Mohammad Saeed 1 *, Mehdi Razavi 1, Curtis G. Neason 2, and Simona Petrutiu 2. Aims.

Quality Standards for the Implantation of Cardiac Rhythm Management Devices. Pan- London Arrhythmia Project Group. Version 3 (18 th July 2011)

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

CONTAK RENEWAL CLINICAL SUMMARY

SYSTEM GUIDE TELIGEN 100 IMPLANTABLE CARDIOVERTER HIGH ENERGY DEFIBRILLATOR REF F102, F103, F110, F111

CONTAK RENEWAL 3 AVT CLINICAL SUMMARY

Implant Procedure Concepts

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

A Closer Look. Connecting DF-4 and IS-4 Leads to DF-4 and IS-4 Defibrillators

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

ALTRUA 50 and ALTRUA 60

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

education Pacemakers for Beginners Institute of Education

Clinical Data Summary: Avoid FFS Study

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

Friedman, Rott, Wokhlu, Asirvatham, Hayes 201. Figure 65.7 Shortening of the AV interval during pacing.

Clinical Results with the Dual-Chamber Cardioverter Defibrillator Phylax AV - Efficacy of the SMART I Discrimination Algorithm

Procurement Support to Ministry of Health, Ukraine. Invitation to Bid for:

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

Defibrillation threshold testing should no longer be performed: contra

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE GUIDANCE EXECUTIVE (GE)

Version überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken.

- DRAFT - SYSTEM GUIDE COGNIS 100-D CARDIAC RESYNCHRONIZATION THERAPY HIGH ENERGY DEFIBRILLATOR. Part 1 of 2 REF N118, N119

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

SYSTEM GUIDE COGNIS 100-D CARDIAC RESYNCHRONIZATION THERAPY HIGH ENERGY DEFIBRILLATOR REF P106, P107, P108

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

Is This Thing Working?

Mahmoud Suleiman MD. On behalf of the Israeli ICD Registry Scientific Committee. Jan 11, National ICD Registry

Implantable Defibrillators Market by Product Type [Transvenous Implantable Cardioverter-Defibrillator (T-ICDs), Subcutaneous Implantable Cardioverter

A Closer Look. X-ray Identification in Boston Scientific Pulse Generators SUMMARY. X-ray Identifier. Figure 1. X-ray identifier

Teaching Rounds in Cardiac Electrophysiology

DESCRIPTION: Infection rate following CIED device implantation, replacement, or revision

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

Version überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken.

IMAGEREADY MR CONDITIONAL PACING SYSTEM

Tachycardia Devices Indications and Basic Trouble Shooting

PHYSICIAN S TECHNICAL GUIDE HeartLogic TM Heart Failure Diagnostic Service

How to set up a device clinic for heart failure patients Dr C Sridevi

D044, D045, D046, D047, D174, D175, D176, D177 D020, D021, D022, D023 D150, D151, D152, D153 D010, D011, D012, D013 D140, D141, D142, D143

Case Description A 25 years old male served in a combat unit for 3 years (GOLANY) Implantation of Dual chamber ICD in 7/2010 due to Severe Non ischemi

Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms

PERFORMANCE MEASURE TECHNICAL SPECIFICATIONS. HRS-3: Implantable Cardioverter-Defibrillator (ICD) Complications Rate

Understanding Atrial Fibrillation A guide for patients

Subcutaneous implantable cardioverter defibrillator insertion for preventing sudden cardiac death

Need to Know: Implantable Devices. Carolyn Brown RN, MN, CCRN Education Coordinator Emory Healthcare Atlanta, Georgia

Diagnostic Value of the ICD Atrial Lead in Accurate Discrimination of Supraventricular from Ventricular Arrhythmias The ALTITUDE EGM Study

Model 5392 EPG Temporary Pacer

Lack of interference of electromagnetic navigation bronchoscopy to implanted cardioverter-defibrillator: in-vivo study

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

2010 Canadian Cardiovascular Society/ Canadian Heart Rhythm Society Training and Maintenance of Competency in Adult Clinical Cardiac

ENABLE MRI CLINICAL STUDY SUMMARY

A Prospective Study Comparing the Sensed R Wave in Bipolar and Extended Bipolar Configurations: The PropR Study

Shock Reduction Strategies Michael Geist E. Wolfson MC

Syllabus and Program of the Diploma in Cardiac Pacing

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART II

Transcription:

A Closer Look Product Education at a glance an ICD or CRT-D When Atrial Information is Not Used SUMMARY Boston Scientific dual-chamber ICDs and multi-chamber CRT-Ds will respond to atrial sensing regardless of whether an atrial lead is implanted. Therefore, if an atrial lead is not going to be implanted or information from an attached atrial lead is not going to be used, certain device parameters should be re-programmed. Products Referenced All Boston Scientific ICDs and CRT-Ds Products referenced herein may not be approved in all geographies. For comprehensive information on device operation and indications for use, reference the appropriate product labeling. CRT-D: Cardiac Resynchronization Therapy Defibrillator ICD: Implantable Cardioverter Defibrillator Contact Information United States www.bostonscientific.com Technical Services U.S. LATITUDE Clinician Support U.S. 1.800.CARDIAC (227.3422) +1.651.582.4000 tech.services@bsci.com latitude@bsci.com Patient Services 1.866.484.3268 International www.bostonscientific-international.com Technical Services Europe +32 2 416 7222 eurtechservice@bsci.com International LATITUDE Customer Support www.latitude.bostonscientificinternational.com latitude.international@bsci.com Copyright 2010 by Boston Scientific Corporation or its affiliates. All rights reserved. Atrial therapy can be a valuable component of the overall therapy plan for ICD or CRT-D patients. Atrial information may be used to inhibit ventricular therapy in the presence of atrial fibrillation or atrial flutter, or it may be used to bypass ventricular therapy inhibitors if the ventricular rate is faster than the atrial rate. While atrial therapy is often beneficial and atrial rate information is useful, there may be clinical situations in which atrial lead information is not useful. Examples include patients in chronic atrial fibrillation, absence of an atrial lead, or atrial lead dislodgement. If atrial lead information is not required or an atrial lead was not implanted (the atrial port is plugged), reconfiguration of certain device parameters and features may be appropriate, as listed in Table 1. Tables 2 and 3 provide information on navigating to the programmer screen where these configuration changes can be made. Table 1. Summary of Changes and Results When Atrial Information is Not Used Parameter Result Pacing Mode Program Mode to VVI(R) a Atrial pacing will not occur Atrial information will not be used to drive brady pacing Atrial sensing will not occur Atrial lead AS markers will not appear configuration b Program the Atrial lead to The accrual of atrial counters will be minimized For Stability/Onset: Program V Rate > A Rate and AFib Rate Threshold to Review Stability and adjust if necessary a Detection Enhancements Episode/EGM Storage c Atrial Daily Measurements For Rhythm ID COGNIS CRT-D / TELIGEN ICD Program Atrial Tachyarrhythmia Discrimination to. Review Stability (For Post-shock only) and adjust if necessary a VITALITY ICD / VITALITY 2 ICD Program Rhythm ID Detection Enhancement Mode to VR Program Episode Data Storage for Brady (ATR and PMT) to 0% Program Atrial Electrogram Storage to Program the atrial Intrinsic Amplitude and atrial Pace Impedance to Therapy decisions will not be based on atrial-based measurements Enables additional storage space in the Arrhythmia Logbook for tachy episodes Atrial diagnostic information will not be collected a Nominal Stability setting is 10-20 ms for dual-chamber and 30 ms for single-chamber ICDs and CRT-Ds. b Applies only to COGNIS CRT-Ds and TELIGEN ICDs. An atrial EP test should not be performed if the atrial lead is programmed to. c Applies to all ICD and CRT-D devices except COGNIS CRT-Ds and TELIGEN ICDs. NOTE: During follow-up visits, the user may de-select the atrial realtime electrogram trace. If an atrial lead is implanted and the physician subsequently elects to utilize atrial information, the disabled/adjusted parameters should be programmed back to the appropriate settings. February 23, 2010 002-1458, Rev. D Page 1 of 5

Table 2. TELIGEN ICDs and COGNIS CRT-Ds: When Atrial Information is Not Used Pacing Mode Atrial Lead Configuration Change the Atrial lead to Tachy (VT Detection Enhancement) Parameters Change Atrial If using Rhythm ID: Tachyarrhythmia Discrimination to Review Stability (For Post- Shock only) and adjust if necessary For both INITIAL DETECTION and POST-SHOCK DETECTION: Change V Rate > A Rate to Change AFib Rate Threshold to Review Stability, and adjust if necessary If using Onset/Stability: VT-1 or VT, whichever zone has Detection Enhancements On February 23, 2010 002-1458, Rev. D Page 2 of 5

Table 2. TELIGEN ICDs and COGNIS CRT-Ds: When Atrial Information is Not Used (continued) Atrial Daily Measurement Setup For the Atrial lead: Change Intrinsic Amplitude to Change Pace Impedance to Final Device When the desired changes have been made, select on the screen or press the Program key on the programmer. NOTE: If an atrial lead is implanted and the physician subsequently elects to utilize atrial information, the disabled/adjusted parameters should be programmed back to the appropriate settings. February 23, 2010 002-1458, Rev. D Page 3 of 5

Table 3. All Other ICDs and CRT-Ds: When Atrial Information is Not Used Pacing Mode (Normal and Post-Shock) Normal: Post-shock: Tachy (VT Detection Enhancement) Parameters For both Initial and If using Detection Redetection: Enhancements: Change V Rate >A Rate to Change A Fib Rate Threshold to Review Stability and adjust if necessary Change Rhythm ID Detection Enhancement Mode to VR VT-1 or VT, whichever zone has Detection Enhancements on If using Rhythm ID (VITALITY / VITALITY 2): February 23, 2010 002-1458, Rev. D Page 4 of 5

Table 3. All Other ICDs and CRT-Ds: When Atrial Information is Not Used (Continued) Arrhythmia Logbook Setup Episode Data Storage: Change Brady (ATR and PMT) to 0% Electrogram Storage Source: Change Atrial to Daily Measurement Setup Change Atrial Intrinsic Amplitude to Change Atrial Pace Impedance to Final Device When the desired changes have been made, press the Program key on the programmer. NOTE: If an atrial lead is implanted and the physician subsequently elects to utilize atrial information, the disabled/adjusted parameters should be programmed back to the appropriate settings. February 23, 2010 002-1458, Rev. D Page 5 of 5