MRIdian. Linac Advantage. For distribution in the United States

Similar documents
The MRIdian Advantage

A New Standard of Care. ASTRO 2017 Update (NASDAQ: VRAY) 1

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

Elekta - a partner and world-leading supplier

PINPOINTING RADIATION THERAPY WITH THE PRECISION OF MR.

I. Equipments for external beam radiotherapy

PRECISE, ROBOTIC TREATMENT AS INDIVIDUAL AS EVERY PATIENT

typical IMRT fraction time and expand high definition radiotherapy anywhere in the body with the widest range of motion of the

Elekta Synergy Digital accelerator for advanced IGRT

S Y N C H R O N Y R E S P I R A T O R Y T R A C K I N G S Y S T E M

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Stereotactic Radiosurgery. Extracranial Stereotactic Radiosurgery. Linear accelerators. Basic technique. Indications of SRS

Elekta Infinity. Digital accelerator for advanced treatments. Redefining treatment precision, speed and control

Overview of Advanced Techniques in Radiation Therapy

Elekta Infinity Digital accelerator for advanced treatments

Mitsubishi Heavy Industries Technical Review Vol. 51 No. 1 (March 2014)

A Patient s Guide to SRS

Department of Radiation Oncology SMART. Stereotactic MR-guided adaptive radiotherapy. Marloes Jeulink Omar Bohoudi

ART for Cervical Cancer: Dosimetry and Technical Aspects

XSIGHT LUNG TRACKING SYSTEM

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

Changing Paradigms in Radiotherapy

Subject: Image-Guided Radiation Therapy

Radiation Oncology. The conf ident path to treatment Philips Radiation Oncology Solutions

Helical Tomotherapy Experience. TomoTherapy Whole Brain Head & Neck Prostate Lung Summary. HI-ART TomoTherapy System. HI-ART TomoTherapy System

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

IMAGE-GUIDED RADIATION THERAPY

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

UCLA UCLA UCLA 7/10/2015. The need for MRI in radiotherapy. Multiparametric MRI reflects a more complete picture of the tumor biology

Protura Robotic Patient Positioning System. for efficiency + performance

Clinical Implementation of a New Ultrasound Guidance System. Vikren Sarkar Bill Salter Martin Szegedi

Stereotactic MR-guided adaptive radiation therapy (SMART) for locally advanced pancreatic tumors

Herlev radiation oncology team explains what MRI can bring

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Precisely Maximize Dose, side effects, Patient

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Chapters from Clinical Oncology

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

5/28/2015. The need for MRI in radiotherapy. Multiparametric MRI reflects a more complete picture of the tumor biology

What is the CyberKnife System?

Motion gating and tracking techniques: overview and recent developments

Elekta R&D Update 22 January 2015, Utrecht

EORTC Member Facility Questionnaire

02 CyberKnife: Treatment Delivery

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

Implementation of advanced RT Techniques

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Original Date: April 2016 Page 1 of 7 FOR CMS (MEDICARE) MEMBERS ONLY

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

Comparison of high and low energy treatment plans by evaluating the dose on the surrounding normal structures in conventional radiotherapy

Intensity Modulated RadioTherapy

Technology Challenges of Commercial Medical Electron Accelerators

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Radiosurgery by Leksell gamma knife. Josef Novotny, Na Homolce Hospital, Prague

SunCHECK Patient Comprehensive Patient QA

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Medical Dosimetry Graduate Certificate Program IU Graduate School & The Department of Radiation Oncology IU Simon Cancer Center

CONFIDENCE IN THE OUTCOMES THAT MATTER MOST TO YOU

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

Radiotherapy physics & Equipments

Unrivaled, End-to-End

Credentialing for the Use of IGRT in Clinical Trials

IMRT for Prostate Cancer

iviewdose Confidence and assurance in dose delivery

Technique For Plan Quality and Efficiency Using VMAT Radiosurgery For Patients with Multiple Brain Metastases

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Outline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams

4D Radiotherapy in early ca Lung. Prof. Manoj Gupta Dept of Radiotherapy & oncology I.G.Medical College Shimla

LA GESTIONE DELLE NUOVE TECNOLOGIE Cinzia Iotti. Azienda Arcispedale S. Maria Nuova IRCCS Reggio Emilia

Page 1. Helical (Spiral) Tomotherapy. UW Helical Tomotherapy Unit. Helical (Spiral) Tomotherapy. MVCT of an Anesthetized Dog with a Sinus Tumor

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

CT Imaging at the Point-of-Care

Advances in external beam radiotherapy

SRS Uncertainty: Linac and CyberKnife Uncertainties

A UNIQUELY SMART RADIATION THERAPY SYSTEM

Your Global Quality Assurance Platform All-in-One. All Connected. All Secure.

Tumor Tracking Current & Future Developments. Josh Evans, Ph.D. Virginia Commonwealth University Richmond, VA

Additional Questions for Review 2D & 3D

Image Guided Stereotactic Radiotherapy of the Lung

WITH. The Next Step in Office MRI

From position verification and correction to adaptive RT Adaptive RT and dose accumulation

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

A UNIQUELY SMART RADIATION THERAPY SYSTEM

Stereotactic Ablative Radiotherapy for Prostate Cancer

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

For a legacy that lives large: Think Big. Philips CT Big Bore. Computed tomography

Proton Beam Therapy at Mayo Clinic

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

Cyberknife Stereotactic Treatment

Plans for the Precision Cancer Medicine Institute University of Oxford

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Intensity-Modulated and Image- Guided Radiation Treatment. Outline. Conformal Radiation Treatment

Transcription:

MRIdian Linac Advantage For distribution in the United States

MRI + LINAC THE FUTURE IS HERE

SIMULTANEOUS IMAGING AND TREATMENT because organ motion matters Visibly Different It is a simple truth. Voluntary and involuntary life-sustaining movements don t stop while your patients are receiving radiation therapy. As your patient moves, the tumor and healthy organs move too preventing accurate treatment and sparing of healthy tissues! At ViewRay, we understand that the best way to deliver an accurate dose of radiation to a moving target is to be able to see inside the body at the time of treatment. That is why we designed MRIdian, the world s first and only MRI-Guided Radiation Therapy System that can image and treat cancer patients simultaneously. MRIdian was an early breakthrough allowing the world s first clinical MRI guided radiation treatments, having treated over 1,200 patients in clinics worldwide. The MRIdian Linac, is ViewRay s latest breakthrough technology. It is based on the clinically proven MRIdian imaging and treatment planning platform. The next-generation radiotherapy solution that integrates a linac with MRI technology in a compact design, together with our proprietary software to locate, target and track the position and shape of tumors while radiation is delivered. MRIdian Linac uses the same split-magnet MRI system used in MRIdian and is designed to fit in standard radiotherapy vaults replacing X-Ray guided linear accelerators. MRIdian Linac can provide continuous soft-tissue imaging during linac-based radiation treatment. Being able to constantly see both the tumor and surrounding organs means you can accurately align the tumor to the treatment beams, adapt or reshape the treatment volume to accommodate changes in the shape and location of the tumor and healthy tissues, and track soft tissues in real time to avoid missing a moving tumor or irradiating sensitive internal structures. MRIdian Linac s proprietary deformable image registration based auto-contouring, Monte Carlo based dose computation, and treatment plan optimization software allow you to review and adapt the treatment plan while the patient is on the table. Over 700 on-table adaptive treatment sessions have been delivered on the MRIdian platform, as described by Acharya et al. [1]. Our MRI-based technology improves tumor visibility and spares as much healthy tissue as possible while powerful tracking tools make sure only the precise amount of radiation prescribed is delivered. The treatment sequences are recorded so you can evaluate the therapy session at any time or share it with your patient for added peace of mind. With MRIdian Linac s enhanced visualization and motion management tools you can treat your patients with clinical confidence, knowing that you will be able to target the tumor accurately and deliver less radiation to your patients healthy tissue. Image and treat simultaneously with MRIdian Linac because organ motion matters! The dosimetric value of reshaping the dose distribution based on daily MRI visualized anatomy basis has been demonstrated by Henke et al. [2] and the dosimetric value of real-time (4 fps) soft tissue target tracking in reducing treatment margins has been demonstrated by Acharya et al. [3]. [1] Acharya, S., et al (2016). Online Magnetic Resonance Image Guided Adaptive Radiation Therapy: First Clinical Applications. IJROBP, 94(2), 394-403. [2] Henke, L., et al. (2016). Simulated Online Adaptive Magnetic Resonance Guided Stereotactic Body Radiation Therapy for the Treatment of Oligometastatic Disease of the Abdomen and Central Thorax: Characterization of Potential Advantages. IJROBP, 96(5), 1078-1086. [3] Acharya, S, et al. (2016). Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion. IJROBP, 96(4), 785-792.

ALIGN ADAPT AND TRACK MRIdian Linac Improves tumor visibility and patient alignment Tracks tumors and manages patient motion Provides on-table adaptive RT planning Accurately records delivered radiation dose Supports advanced therapy techniques Fits into existing treatment paradigms and workflow Right Breast Mediastinum Head/Neck Right Lung Bladder Mesenteric Aortic Arch Hilum Soft Tissue ABD Pancreas Mediastinal LN Adrenal Rib Pelvic LN Paraaortic Liver Iliac Stomach Spine Soft Tissue Neck Left Lung Spleen Colon Periaortic Left Breast Prostate Soft Tissue Pelvis Rectum 1

ULTRA-FAST TREATMENT PLANNING without compromising quality MRIdian Linac offers an adaptive, automated and integrated treatment planning system that uses a linac to deliver modulated radiation therapy. Our proprietary Monte Carlo Treatment Planning System is ultra-fast without compromising quality. MRIdian Linac fits into existing treatment paradigms and can be used for three-dimensional conformal radiation therapy planning (3D-CRT); intensity modulated radiation therapy planning (IMRT); stereotactic radiosurgery (SRS); stereotactic body radiation therapy (SBRT); and image-guided radiation therapy (IGRT); across a broad spectrum of disease sites. Treatment Planning Workstations (TPW): Both Treatment Planning and Delivery workstations have a minimum of twelve processor cores, 64 GB RAM, 1.5 GB video memory, ample hard disk space and an oversized LCD display. Treatment Planning and Delivery Software (TPDS): The TPDS operates on both a remote TPW and on the treatment delivery system. Treatment plans may be created to pre-plan treatment using volumetric CT, MRI, or PET images on remote workstations. The TPDS is designed to create optimized 3D-CRT, IMRT, SRS and SBRT, conformal and combinations of IMRT and conformal treatment plans for delivery on our IGRT system.

MRIdian Linac Treatment Flow MRI Positioning Scan DAILY TREATMENT FLOW under 20 minutes Auto-Contour ALIGN MRI Positioning Scan Patient Setup An integrated MRI unit captures volumetric soft-tissue images for accurate pretreatment positioning in just a few seconds. The high- quality soft-tissue contrast allows you to locate the tumor and align the patient to the treatment beams accurately without using X-ray, CT or surrogate registration markers. MRIdian Linac allows for accurate automatic patient alignment. ADAPT Auto-Contour MRIdian Linac provides real-time imaging that clearly defines the targeted tumor from the surrounding soft tissue and other critical organs. Using an MRI image captured at the beginning of each therapy session, the system automatically identifies and maps the patient s soft tissue anatomy in 3D. It then transfers contours to the daily image using a rigid or deformable registration. On-Table Dose Prediction On-Demand Optimization On-Table Dose Prediction On-table dose computation rapidly produces dose distributions and DVHs to predict the anticipated dose delivery. While the patient is on the treatment table the system compares the pretreatment MRI image to the planning image and automatically calculates the required dose to be delivered to the target using the current treatment plan. If the dose prediction and prescribed treatment is not clinically acceptable, you can change this on demand. On-Demand Optimization Utilizing our proprietary Monte Carlo algorithm and software, MRIdian Linac calculates the optimal treatment plan for the patient at the time of treatment. MRIdian Linac has the ability to automatically recalculate the dose and adapt the treatment plan to changes in the patient s anatomy at the time of treatment. You can re-optimize and re-plan your treatment session in less than two minutes while the patient is on the table.

TRACK Track Tissue and Manage Patient Motion MRIdian Linac captures multiple soft-tissue imaging planes concurrently during treatment, refreshing the image multiple times per second. This real-time imaging allows you to track the movement of the tumor and the surrounding healthy tissue directly as well as verify the target and tracking boundary. If a specified percentage of tumor or critical organ moves beyond a physician-defined boundary, the treatment beam automatically pauses. When the tumor moves back into the predefined boundary, treatment automatically resumes. Beam control is especially important in situations where tumors may be in close proximity to critical organs. Treatment MRIdian Linac can be used for 3D-CRT, IMRT, IGRT, SBRT and SRS across a broad spectrum of disease sites. MRIdian Linac s increased target accuracy allows you to treat patients with higher doses of radiation over fewer treatment fractions. This, combined with improved tumor visibility and accurate dose recordings, means you can treat patients who would not previously have been considered radiation therapy candidates. MRIdian Linac also captures and records a video of the delivered treatments, called MRIdian Movie, for later evaluation or for sharing with your patients. Physician Review MRIdian Linac calculates the dose delivered after each treatment and records the level of radiation exposure that the tumor has received, allowing you to review and adapt the prescription between fractions on demand. MRIdian Linac provides you with complete information and a wide range of powerful review and assessment tools, allowing you to deliver targeted, personalized radiotherapy for each patient. TREATMENT FLOW 15 20 Minute Time Slot Patient Setup Auto-Contour Dose Prediction ALIGN, ADAPT AND TRACK WITH VISUAL CLINICAL CONFIDENCE Re-Optimization Track & Verify Treatment M.D. Review

SOPHISTICATED SCIENTIFIC DESIGN optimal field strength for radiation therapy MRI SYSTEM Visibly Different One of the most significant advantages of MRIdian Linac is that it integrates an MRI system with a Radiation Delivery System. The MRI component of MRIdian Linac captures soft tissue images of the patient s body simultaneously during treatment. We have engineered our MRI system to be able to produce high-quality images using a low field strength 0.35 Tesla magnet. One of the key benefits of this design is that it provides optimal field strength for radiation therapy. The 0.35 Tesla magnet allows the system to avoid the image artifacts and distortions in the dose distribution that occur when using a high field strength magnet. MRIdian Linac s low field MRI allows for geometrically precise images, without susceptibility distortions or chemical-shift artifacts, and accurate dose distributions. Furthermore, at 0.35 T, owing to the lower RF excitation frequency, RF induced tissue heating is a non issue, allowing uninterrupted MR imaging of the patient. The MRI imaging system fits in standard vaults and has unique pop-apart design as shown below to enable non-destructive rigging. Another feature of our patented design is the split superconducting magnet. This addresses technical complications that can arise from combining an MRI with a LINAC because the split magnet allows for unobstructed beam path through a central gap.

Magnetic shield RF shield Linear accelerator RADIATION DELIVERY SYSTEM Radiation is delivered from a compact inline S-band 6 MV standing wave linac with side coupled cavities. The flattening filter free linac is designed to deliver 600 cgy/min. The highlight of the MRIdian Linac design is the patented magnetic and RF shielding that isolates the workings of a linac and the MRI system from each other. A Linac emits RF energy that may interfere with the MRI image acquisition process and affect MRI image quality. MRIdian Linac uses copper shields enforced with carbon fiber for RF shielding. The combination of the materials reduces RF leakage from the linac to almost zero, ensuring zero impact on the MR image quality. The linac gantry is located in the central gap of the split super conducting magnet. ViewRay has developed specialized magnetic shielding technology consisting of concentric steel shells that create a central magnetic void at the linac components, in the otherwise uniform magnetic field of the MRI. The linac is equipped with a *138-leaf double focused double stacked multi-leaf collimator (MLC) with minimum penumbra to shape the beam for precision radiation therapy treatments. *Double Stack MLC is 510(k) pending.

FULLY INTEGRATED SYSTEM for intuitive workflow INTERVENTIONAL MRI-IMAGING SYSTEM Split Superconducting Magnet 0.35 T MRI does not distort patient images or dose distributions 50 cm diameter of spherical volume (DSV) Allows unobstructed beam path Designed for simultaneous soft-tissue imaging during therapy Low-field ensures no RF induced heating in patients State-of- the-art split gradient coil with massive cooling capacity for unlimited fast scanning Low- density uniformly radiation-attenuating receive coils ensure superior image quality and optimal dose distributions 70 cm bore diameter accommodates large patients Fits in standard vaults with pop-apart design for non-destructive rigging and installation LINAC BASED RADIATION THERAPY SYSTEM Flattening filter free design enables dose rate >600 cgy/min Enables fast IMRT, SBRT or conformal external beam radiation therapy *138-leaf Double-Focused Double Stacked Multi-Leaf Collimator (MLC) system for reduced penumbra and minimum interleaf leakage INTELLIGENT AUTOMATED SOFTWARE On-table Adaptive Treatment Planning with autocontouring, deformable image registration, realtime Monte Carlo calculation and full scale IMRT and SBRT optimization in under 2 minutes Real-Time MRI-guided tracking of soft tissue to control beam delivery via on-the-fly target registration and real-time beam control Comprehensive Database and Informatics System captures all simulation, treatment planning and the treatment delivery information Automatic archiving of all parameters, images, treatment plans and accumulated dose to target via deformable image registration and Monte Carlo simulation On-Table Dose Prediction INTEGRATED WORKFLOW Operators Console Integrated console for patient positioning, ontable dose prediction, treatment plan optimization and re-planning, real-time tissue tracking and treatment Treatment Planning Station Soft Tissue Tracking Support for multi-modality image based reviewing, contouring, treatment planning and treatment monitoring Automatically Updated Database Server Captures all patient and machine data *Double Stack MLC is 510(k) pending.

KEY SYSTEM SPECIFICATIONS Parameter Beam Energy Beam Source Size Dose Rate Isocenter Distance 6 MV ~ 0.2 cm > 600 cgy/min (FFF) in water at 90 cm SAD, for a 10 cm x 10 cm field 90 cm MLC *138 leaves, double focused, double stacked MRI System Parameters Field Strength Magnet type Bore diameter Homogeneity over 45 cm DSV Field of View Spatial integrity 0.35 T Superconducting 70 cm < 25 ppm 50 cm < 0.2 cm over 35 cm DSV < 0.1 cm over 20 cm DSV Patient couch weight limit Patient couch repositioning accuracy Patient couch travel range at isocenter 440 lbs + 0.1 cm Vertical: 0 to -20 cm Lateral: -7 to +7cm *Double Stack MLC is 510(k) pending.

EASY SITE PLANNING system fits into a standard vault Visibly Different SPACE REQUIREMENTS Recommended Vault Size: 19-2 (5.9 m) x 24-8 (7.6 m) Minimum Finished Ceiling Height: 9-6 (2.9 m) Minimum Clear Opening into Vault: 3-11 (1.2 m) W x 6-11 H (2.1 m) Recommended RF Closet Size: 3-8 (1.1 m) x 4-0 (1.2 m) MRIdian Linac is designed to fit into a typical radiation therapy vault, similar to other replacement linear accelerators. All of the components fit through standard hospital vault entrances for easy assembly.

ViewRay, Inc. (NASDAQ:VRAY) is a medical device company developing advanced radiation therapy technology for the treatment of cancer. ViewRay holds the exclusive worldwide license for its combination of MRI and radiation therapy technologies. MRI-guided radiation therapy was conceived by company founder James F. Dempsey, Ph.D., while he was a member of the radiation oncology faculty at the University of Florida in 2003.

exclusively focused on MRI-guided radiation therapy As the innovators of practical and clinical MRI-guided radiation therapy ViewRay continues to add to a growing list of industry firsts, First on-table adaptive RT system First patient treated with MRI-guided RT First FDA-cleared MRI-guided RT system -MRIdian First CE-marked MRI-guided RT system First to provide direct soft tissue tracking First exclusively Monte Carlo TPS First MRI-guided system to fit in standard vaults First commercially available MRI-guided Linac system At ViewRay we believe that MRI-guided radiation delivery should be the standard of care for radiation therapy. We are partnering with top-tier hospitals including leading university research and teaching hospitals in a global effort to educate radiation oncologists about the capabilities and resulting benefits of MRI-guided radiation delivery over traditional radiation therapy systems. We will maintain our competitive lead in MRI- guided radiation therapy and adaptive treatment planning by committing to continued innovation. We are working with leading cancer centers and early adopters of bestin-class technology to collect and publish data on clinical efficacy, treatment times and clinical results for patients who have been treated on our first FDA cleared product - MRIdian. ViewRay will continue to support the publication of clinical and scientific data and analysis, work with key opinion leaders, present at leading academic conferences and engage in outreach at leading hospitals worldwide. Utilizing professional feedback to guide product development, we plan to continue to introduce enhancements to the system that will maximize the efficiency and effectiveness of our products for our customers and improve patient outcomes. ViewRay is exclusively focused on MRI-guided radiation therapy. By continuing to invest in our technology we are confident that we will maintain our leadership position in the emerging MRI-guided radiation therapy market.

World Leader in MRI Guided Adaptive Radiation Therapy

www.viewray.com ViewRay Corporate Headquarters 2 Thermo Fisher Way Oakwood Village, OH 44146 USA Tel: +1 440 703 3210 ViewRay West Coast Office 815 East Middlefield Road Mountain View, CA 94043 USA Tel: +1 650 252 0920 European Authorized Regulatory Representative: MedPass International Ltd. Winsor House Bretforton, Evesham, Worcestershire, WR11 7JJ, United Kingdom. 0086 L-0083 Rev D March 2017