PRO-DENSE Bone Graft Substitute The following languages are included in this packet:

Similar documents
PRO-DENSE BONE GRAFT SUBSTITUTE

The following languages are included in this packet:

CELLPLEX TCP SYNTHETIC CANCELLOUS BONE

EVOLVE TRIAD BONE SCREWS

ENDO-FUSE INTRA-OSSEOUS FUSION SYSTEM The following languages are included in this packet:

SIDEKICK EZ FRAME EXTERNAL FIXATION SYSTEM The following languages are included in this packet:

EVOLVE TRIAD SYSTEM

METAL HEMI SYSTEM

DARCO MIS FOREFOOT SCREW

BIOFOAM ANKLE SPACER BLOCK

The following languages are included in this packet:

Metallic Internal Fixation Devices The following languages are included in this packet:

ORTHOLOC 3Di PLANTAR LAPIDUS PLATE

EXTERNAL FIXATION SYSTEMS The following languages are included in this packet:

METATARSAL DECOMPRESSION IMPLANT (MDI) SYSTEM

BIOARCH SUBTALAR IMPLANT SYSTEM

CLAW II POLYAXIAL COMPRESSION PLATING SYSTEM

BONE VOID FILLERS CONTAINING DONATED HUMAN TISSUE The following languages are included in this packet:

MICA SCREWS For additional information and translations please contact the manufacturer or local distributor.

BIOFOAM BONE WEDGE

ORTHOLOC 3Di ANKLE FUSION PLATING SYSTEM

CASE STUDY: PRO-DENSE Injectable Regenerative Graft Used to Backfill a Bone Cavity Following Resection of a Giant Cell Tumor

Technique Guide KISSloc Suture System

DARCO HEADED CANNULATED SCREWS

For use by an Accredited Orthopaedic Surgeon only

Technique Guide Small Bone Fusion System

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

ADVANCED BONE GRAFT SYSTEM OVERVIEW

Device Preparation (all steps to be performed per standard interventional technique)

MICROPORT KNEE SYSTEMS The following languages are included in this packet:

STABILIZATION AND FRACTURE FIXATION

INVISION TOTAL ANKLE REVISION SYSTEM The following languages are included in this packet:

Cerasorb M DENTAL. O:\Zulassung\Cerasorb Dental Kanada 2013\Texte\Cerasorb M Dental final IFU docx

Calcium Phosphate Bone Void Filler TECHNIQUE GUIDE

DISTAL RADIUS. Instructions for Use

JRI Thompson Hemiarthroplasty

Customized Cranial and Craniofacial Implants. Instructions For Use. 7000revD_Instructions_For_Use. Page 1 of 8

TOTAL ELBOW SYSTEM The following languages are included in this packet:

POSTERIOR LUMBAR FUSION SURGICAL TECHNIQUE USING A BONE VOID FILLER. Magnifuse. Bone Graft

St. Jude Medical 8-Channel Adapter. Clinician's Manual

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

Yasargil Permanent Aneurysm Clips

Salto Talaris Total Ankle Prosthesis

Lapidus Arthrodesis System Instructions for Use

TC-PLUS Primary Knee IMPORTANT MEDICAL INFORMATION SPECIAL NOTE. This Package Insert is for product distributed in the US only.

Single Use Curlew TM Multiple Biopsy Forceps

OPERATIVE TECHNIQUE. CONSTRUX Mini PTC. Mini PTC Spacer System

Document No Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE

Implantable K-wire SURGIC A L T ECHNIQUE

INTELLIGENT SPINAL SYSTEM

Precautionary Statement ( )

MASTERGRAFT Putty. Technical Guide

Instructions for use for Bone Plates, Bone Screws, Intramedullary Nails, Pins and Wires

INSTRUCTIONS FOR USE FOR:

CANNULATED SCREW SYSTEM The following languages are included in this packet:

SALVATION EXTERNAL FIXATION SYSTEM

Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6

Doc. No.: IU/8 for. Rev. No.: 07 ResTOR Prosthesis

Instructions for Use io-flex Probe

Aesculap CranioFix absorbable

Doc no: IFU/CPL Issue date: Rev no: 00 Rev date: 1

Norian Drillable: A Competitive Analysis

REPIPHYSIS LIMB SALVAGE SYSTEM

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

Important notice: the device(s) can be prescribed and implanted only by a doctor legally authorized to perform this type of surgery.

INBONE II. Total Ankle System SURGICAL TECHNIQUE SUPPLEMENT TIBIAL REAMING SPECIFICATION

TOTAL ANKLE SYSTEMS

C-THRU Anterior Spinal System

Important Information on ATLAS Hip Fracture Nail For use by an Accredited Orthopaedic Surgeon only

Desara TV and Desara Blue TV

WristMotion Wrist Hemiarthroplasty System Instructions for Use

Revision A Date:

SALVATION EXTERNAL FIXATION SYSTEM

DMF Page 63. Description

Aesculap CeSpace TM PEEK and CeSpace TM XP Spinal Implant System Instructions for Use

PERFORATED CLICK X Augmentable pedicle screws for osteoporotic bone

CAUTION Federal law (USA) restricts this device to sale, by or on the order of a physician.

HawkeyeTM Peek. surgical technique

AXS Catalyst Distal Access Catheter

Page 1 of 7 Doc. No.: IU/15 Rev. No.: 05 Rev. Date:03MAY2018. Instructions for use for ATLAS Tibial Fracture(TF) Nail

Doc no: IFU/CC Issue date: Rev no: 04 Rev date:

FUSEFORCE. Hand Fixation System SURGICAL TECHNIQUE

Zimmer Anterior Buttress Plate System. Surgical Technique

Duracryl sutures should be selected and implanted depending on the patient condition, surgical experience, suturing technique and wound size.

TriboFit Hip System. Issue 3 - August 2013 English

SYNPOR POROUS POLYETHYLENE IMPLANTS. For craniofacial and orbital augmentation and reconstruction

SYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only

BONE GRAFT WASHER _Rev A IMPORTANT INFORMATION ON THE BONE GRAFT WASHER

Talar Dome System Surgical Technique

Low Profile Neuro Plating System. Surgical Technique

Polyurethane Dual Lumen Occlusion Catheter English Instructions for Use. Polyurethane Dual Lumen Occlusion Catheter

Peel-Apart Percutaneous Introducer Kits for

Duraloc CONSTRAINED LINER

ALLOPURE. Bicortical Allograft Wedges Specific for Evans and Cotton Osteotomies SURGICAL TECHNIQUE

For use by an Accredited Orthopaedic Surgeon only

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

low ProfIle neuro PlaTIng system

Transcription:

EN PRO-DENSE Bone Graft Substitute 133486-11 The following languages are included in this packet: English (en) For additional languages, visit our website www.wmt.com Then click on the Prescribing Information option. For additional information and translations please contact the manufacturer or local distributor. M* C 0086* P Wright Medical Technology, Inc Wright Medical EMEA 5677 Airline Rd Hoogoorddreef 5 Arlington, TN 38002 1101 BA Amsterdam U.S.A. The Netherlands * The CE-Marking of Conformity is applied per catalog number and appears on the outer label, if applicable. April 2013 Printed in U.S.A.

Attention Operating Surgeon IMPORTANT MEDICAL INFORMATION WRIGHT MEDICAL PRO-DENSE Bone Graft Substitute (133486-11) OUTLINE: DEFINITIONS GENERAL PRODUCT INFORMATION A. INDICATIONS B. CONTRAINDICATIONS C. POTENTIAL COMPLICATIONS D. PRECAUTIONS E. ADVERSE REACTIONS F. HANDLING & STERILIZATION G. STORAGE CONDITIONS H. DIRECTIONS FOR USE/MIXING INSTRUCTIONS

DEFINITIONS Symbols and abbreviations may be used on the package label. The following table provides the definition of these symbols and abbreviations. Table 1. Definitions of Symbols and Abbreviations Symbol g h D Y i H l p N M P I K Definition Batch code Catalog number Do not re-use Caution, consult accompanying documents Consult operating instructions Use by Storage temperature limitation Keep dry Keep away from sunlight Date of manufacture Manufacturer Authorized EC Representative in the European Community Sterilized using ethylene oxide Sterilized using radiation Sterilized using gas plasma For prescription use only Do not use if packaging is ripped or damaged 2

Abbreviation Ti Ti6Al4V CoCr SS UHMWPE CaSO4 HA Material Titanium Titanium Alloy Cobalt Chrome Alloy Stainless Steel Ultra High Molecular Weight Polyethylene Calcium Sulfate Hydroxyapatite GENERAL PRODUCT INFORMATION PRO-DENSE Bone Graft Substitute paste consists of pre-measured surgical grade calcium sulfate and calcium phosphate, pre-measured neutralized glycolic acid mixing solution, and the tools necessary to mix the components into a paste and inject the material into the defect site. When mixed and injected according to directions, PRO-DENSE Bone Graft Substitute paste will harden in situ and provide temporary intra-operative support. PRO-DENSE Bone Graft Substitute products are provided sterile for single patient use. A. INDICATIONS PRO-DENSE resultant paste is intended for use as a bone graft substitute to be injected or digitally packed into open bone voids/gaps that are not intrinsic to the stability of bony structure of the skeletal system (i.e., the extremities and pelvis) to cure in situ. These open bone voids may be surgically created osseous defects or osseous defects created from traumatic injury to the bone. The paste provides a bone graft substitute that resorbs and is replaced with bone during the healing process. The PRO-DENSE paste cured in situ provides an open void/gap filler that can augment provisional hardware (e.g. K-Wires) to help support bone fragments during the surgical procedure. The cured paste acts only as a temporary support media and is not intended to provide structural support during the healing process. PRO-DENSE is provided sterile for single use only. For the PRO-DENSE Core Decompression Procedure Kit: The PRO-DENSE Core Decompression Procedure Kit, consisting of a bone void filler and manual surgical instruments, is intended to be used during core decompression procedures. The bone void filler component resorbs and is replaced with bone during the healing process. The bone void filler included in the PRO-DENSE Core Decompression Procedure Kit is not intended to be used as a load-bearing device. B. CONTRAINDICATIONS The PRO-DENSE Bone Graft Substitute injectable paste is contraindicated where the device is intended as structural support in load-bearing bone and in articulating surfaces. Conditions representing relative contraindications include: Severe vascular or neurological disease Uncontrolled diabetes Severe degenerative bone disease Closed bone void/gap Pregnancy Uncooperative patients who will not or cannot follow postoperative instructions, including individuals who abuse drugs and/or alcohol 3

Hypercalcemia Renal compromised patients Patients with a history of or active Pott s disease C. POTENTIAL COMPLICATIONS Proper surgical procedures and techniques are the responsibility of the medical professional. Each surgeon must evaluate the appropriateness of the procedure used based on personal medical training and experience. Although Wright Medical cannot recommend a particular surgical technique suitable for all patients, a detailed surgical technique is available for surgeon reference. D. PRECAUTIONS As with any surgical procedure, care should be exercised in treating individuals with preexisting conditions that may affect the success of the surgical procedure. This includes individuals with bleeding disorders of any etiology, long-term steroidal therapy, immunosuppressive therapy, or high dosage radiation therapy. Avoid overfilling the bone void or pressurizing the treatment site. The provided K-Wires (where supplied) are not intended for implantation. Use PRO-DENSE Bone Graft Substitute injectable paste as supplied and according to the Handling and Use information provided. All powder (supplied) and all solution (supplied) must be used when mixing paste. This device has not been evaluated for safety and compatibility in the MR environment. This device has not been tested for heating or migration in the MR environment. Warning: Do not use kit if any container is cracked or broken. For the 4cc kit only: Warning: the stylet of the needles contains nickel which is a known allergen to a small percentage of the population. Intra-Operative Precautions Use medical devices in accordance with their labeled indications and Wright Medical Technology s instructions for use, especially during insertion and removal. Inspect devices prior to use for damage during shipment or storage or any out-of-box defects that might increase the likelihood of fragmentation during a procedure. Inspect devices immediately upon removal from the patient for any signs of breakage or fragmentation. If the device is damaged, retain it to assist with Wright Medical Technology s analysis of the event. Carefully consider and discuss with the patient (if possible) the risks and benefits of retrieving vs. leaving the fragment in the patient. Advise the patient of the nature and safety of unretrieved device fragments including the following information: a. The material composition of the fragment (if known); b. The size of the fragment (if known); c. The location of the fragment; d. The potential mechanisms for injury, e.g., migration, infection; e. Procedures or treatments that should be avoided such as MRI exams in the case of metallic fragments. This may help to reduce the possibility of a serious injury from the fragment. 4

E. ADVERSE EFFECTS Possible adverse effects include but are not limited to: Wound complications including hematoma, site drainage, bone fracture, infection, and other complications that are possible with any surgery Fracture or extrusion of the bone void filler, with or without particulate debris generation Deformity of the bone at the site Incomplete, or lack of, osseous ingrowth into bone void, as is possible with any bone void filler. Transient hypercalcemia Potential to pressurize material in a closed void, which could result in fat embolization and/or embolization of the device material into the blood stream. F. HANDLING AND STERILIZATION PRO-DENSE Bone Graft Substitute injectable paste is provided sterile and should be considered sterile unless the inner packaging has been opened or damaged. This product should not be resterilized. The kits are for single patient use and should never be reused. Devices labeled for single-use only should never be reused. Reuse of these devices may potentially result in serious patient harm. Examples of hazards related to the reuse of these devices include, but are not limited to: significant degradation in device performance, cross-infection, and contamination. G. STORAGE CONDITIONS All kits must be stored in a clean, dry environment and be protected from sunlight and extremes in temperature. The PRO-DENSE Bone Graft Substitute products should be stored at 15-30 C or 59-86 F. H. DIRECTIONS FOR USE/MIXING INSTRUCTIONS The PRO-DENSE Bone Graft Substitute injectable paste is supplied in a kit that contains the components and tools required to mix and inject the resultant paste. Detailed mixing and handling instructions are included on the Mixing Instructions Card. CAUTION: Federal Law (U.S.) restricts this device to the sale, distribution, and use by or on the order of a physician. 5