Albert Lisbona Medical Physics Department CLCC Nantes Atlantique a

Similar documents
Guideline & Reports 医学物理学会教育委員会資料

EORTC Member Facility Questionnaire

New Radiation Health Technologies Challenges, Opportunities, Limitations

Plans for Future Radiotherapy Physics Education in the Russian Federation

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Horizon Scanning Technology Briefing National Helical Tomotherapy Horizon Hi-ART System for Scanning external cancer Centre radiotherapy August 2006

Hong Kong Association of Medical Physics. Guide to Candidates

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Quality assurance in external radiotherapy

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

The Journey of Cyberknife Commissioning

SunCHECK Patient Comprehensive Patient QA

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

I. Equipments for external beam radiotherapy

The RPC s Evaluation of Advanced Technologies. AAPM Refresher Course July 29, 2008 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Who Should Know Radiation Oncology Coding?

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

8/2/2018. Disclosures. In ICRU91: SRT = {SBRT/SABR, SRS}

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Overview of Advanced Techniques in Radiation Therapy

ph fax

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

National Institute for Health and Clinical Excellence. Health Technology Appraisal. IIntensity modulated radiotherapy for prostate cancer

The 1 st. FARO Council Meeting. May 30, 2015 Kyoto International conference center, Japan

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

Training Course on Small Field Dosimetry

Economic Implications of Advancements in Radiation Technology. Dramatic Growth of RT Capacity in the US

Small field dosimetry, an example of what a Medical Physicist does (& some more examples) A/PROF SCOTT CROWE MEDICAL PHYSICIST

IEC Subcommittee 62C (Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry): Recent and Active Projects

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Major accidents in radiotherapy

Elekta Synergy Digital accelerator for advanced IGRT

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

International Practice Accreditation

SRS Uncertainty: Linac and CyberKnife Uncertainties

What is the CyberKnife System?

Implementation of advanced RT Techniques

Canadian Partnership for Quality Radiotherapy. Technical Quality Control Guidelines for Gamma Knife Radiosurgery. A guidance document on behalf of:

Radiotherapy physics & Equipments

RISK ASSESSMENT IN RADIATION THERAPY OF PATIENTS USING PROBABILISTIC SAFETY ANALYSIS OF RADIOTHERAPY DEVICES

Session 17 Practical Implementation of New Technologies in Low-to-Middle Income Countries

An Independent Audit and Analysis of Small Field Dosimetry Quality Assurance. David Followill IROC Houston QA Center

TomoTherapy. Michelle Roach CNC Radiation Oncology Liverpool Hospital CNSA. May 2016

iviewdose Confidence and assurance in dose delivery

SRS/SBRT Errors and Causes

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Patient-specific quality assurance for intracranial cases in robotic radiosurgery system

Understanding Radiation Therapy. For Patients and the Public

1ª Jornada de Análisis de Riesgos en RT. 10 de Dic 2014 José Luis Roldán

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Unrivaled, End-to-End

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

Monte Carlo for CyberKnife Incise TM MLC

LA GESTIONE DELLE NUOVE TECNOLOGIE Cinzia Iotti. Azienda Arcispedale S. Maria Nuova IRCCS Reggio Emilia

Special Procedures Rotation I/II SBRT, SRS, TBI, and TSET

IPEM Recommendations for the Provision of a Physics Service to Radiotherapy

EBAMP European Board for Accreditation in Medical Physics

Clinical experience with TomoDirect System Tangential Mode

Eric E. Klein, Ph.D. Chair of TG-142

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

CODING GUIDELINES. Radiation Therapy. Effective January 1, 2019

DEPT OF RADIATION ONCOLOGY DEPT OF RADIATION ONCOLOGY

Advances in external beam radiotherapy

New Radiation Treatment Modalities in the Treatment of Lung Cancer

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

New Technology. New Technology. Summary. Data Collection. Hospital charge data used in APC grouping and payment

BELdART-2: Moving towards safer radiotherapy. Steven Lelie 1,2, Wouter Schroeyers 1, Brigitte Reniers 1, Sonja Schreurs 1

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

IAEA Support to Medical Physics in Africa and Latin America: achievements & challenges

Innovative RT SBRT. The variables with REQ in superscript are required.

IAEA activities in Medical Physics

The future of radiation therapy. Safe and innovative options, including the CyberKnife System

Concept for quantifying the dose from image guided radiotherapy

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Changing Paradigms in Radiotherapy

Mitsubishi Heavy Industries Technical Review Vol. 51 No. 1 (March 2014)

M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

RPC s Credentialing Programs for Clinical Trials

Quality Assurance in Radiation Therapy

HALF. Who gets radiotherapy? Who gets radiotherapy? Half of all cancer patients get radiotherapy. By 1899 X rays were being used for cancer therapy

About Cancer Research UK

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

QA for Clinical Dosimetry with Emphasis on Clinical Trials

Proton Stereotactic Radiotherapy: Clinical Overview. Brian Winey, Ph.D. Physicist, MGH Assistant Professor, HMS

Radiation treatment planning in lung cancer

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

An anthropomorphic head phantom with a BANG polymer gel insert for dosimetric evaluation of IMRT treatment delivery

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

Radiotherapy In-vivo Treatment Verification: Multi-center analysis for more than 6 million fractions delivered

ADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER

Transcription:

The Equipment : safety, commissioning, re commissioning calibration : Equipements : sûreté, recette, modification calibration A medical physicist point of view. Albert Lisbona Medical Physics Department CLCC Nantes Atlantique a lisbona@nantes.fnclcc.fr

CT Scanner SPECT-CT MRI PET-CT Radiotherapy Information System Network Treatment delivery Radiotherapy Treatment Planning System Medical Linear Accelerator

Acceptance and Commissioning Acceptance : to verify that the machine fulfills all the specifications given by the manufacturer and the ones agreed on as requirements for purchase. In addition to this the unit should fulfill ALL safety requirements as documented by national and international standards (e.g. IEC documents). Manufacturer representative and hospital representative Commissioning : to ensure that the unit is suitable for patient treatment within a certain department including preparation and verification of planning data. Hospital representative

Commissioning Commissioning of radiotherapy equipment is a very important and complex process. One needs to know all specs of the equipment AND have the appropriate tools in relation with the technical level of radiotherapy procedures for patient. Only qualified experts should perform the commissioning and certify that a treatment unit is fit for use on patients.

Commissioning Simple treatments, 3D Conformal Radiation Therapy treatments, Complex treatments : Intensity Modulated Radiation Therapy (which conforms the dose more closely to the shape of the tumor target) with image guidance (Image Guided Radiation Therapy) Stereotactic RadioSurgery Stereotactic Radiation Therapy Respiratory gated radiation therapy

3D CRT IMRT To increase target dose with sparing of healthy tissue. Use of adapted equipments : 3D dose calculation software (convolution superposition algorithms), Medical linear accelerator, MultiLeavesCollimator, Real time imaging devices. To increase target dose with sparing of healthy tissue by 3D CRT optimization. Same equipments + : Adapted software using doses volumes constraints (knowledge data bases) to realize optimization.

Commissioning Innovative machines such as : HiArt (Tomotherapy), Cyberknife (Accuray).

QA AAPM, IPEMB, SEFM, SFPM,. Quality assurance recommendations including commissioning well established concerning : Medical imaging devices (CT scanner, SPECT/PET CT, MRI) Medical Linear Accelerators Radiotherapy Treatment Planning System In some countries these recommendations have been turned into regulation. Innovative radiotherapy is growing faster than quality assurance recommendations.

Re commissioning When the machine is upgraded to full production standards : Software version upgrade, Hardware upgrade (e.g. micromlc, IGRT, stereotactic treatments, ) Partially when change or upgrade of the Radiotherapy Information System.

Conclusion Quality Assurance program in order to maintain : Physical performances of equipments, Reliability on radiotherapy procedures, Level of confidence throughout the radiotherapy team. To pay particular attention to new technologies and/or complex radiotherapy procedures especially vs staff leveling.

Some references. IEC IAEA IEC 60601 2 1 Ed.3.0 Medical electrical equipment Part 2 1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV IEC 62083 Ed 2.0 Medical electrical equipment Requirements for the safety of radiotherapy treatment planning systems

Some references. IMRT SRS TPS M. Alber et al.., Guidelines for the Verification of IMRT ESTRO, Brussels, Belgium, 2008. G.A. Ezzell et al. IMRT commissioning : Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119, Med. Phys. 36 (11) November 2009. M.C. Schell et al. Stereotactic Radiosurgery, Report of Task Group 42, 1995. IAEA TECDOC 1540 Specification and Acceptance Testing of Radiotherapy Treatment Planning Systems April 2007.