Hoffmann II MRI External Fixation Systems. Hoffmann II MRI Hoffmann II Compact MRI Modular Systems for Upper Extremity Lower Extremity Pelvis

Similar documents
Hoffmann II Compact External Fixation System

Hoffmann II Compact External Fixation System. Modular System for

Hoffmann II External Fixation System

Hoffmann II Micro External Fixation System. Indications for the Hand

Hoffmann II Micro External Fixation System

Gamma3 TM Fragment Control Clip

EXTERNAL FIXATION SYSTEM

Hoffmann 3 Modular External Fixation. Operative technique

EXTERNAL FIXATION SYSTEM

Large External Fixator Modular Knee Bridge. Using multi-pin clamps.

VBOSS TM System Overview. Vertebral Body Support System

Large External Fixator Delta Frame Ankle Bridge. For staged fixation of the distal tibia.

Medium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use.

Hoffmann LRF Circular External Fixation. Operative technique

AxSOS Locking Plate System

Large External Fixator Delta Frame Ankle Bridge. Using pin clamps with outrigger posts.

Medium External Fixator Pediatric Femoral Shaft Frame. Using medium multi-pin clamps.

Sterile-Packaged Large External Fixator Kits. For treatment of long bone and pelvic fractures that require external fixation.

Flexibility In Action. ACL Instrumentation

VariAx TM Distal Radius Locking Plate System

Multi-Guide II Mandibular Distractor

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

onotube TRIAX EXTERN AL FIXATION SYSTEM

EasyStep. Operative technique

Monotube Triax. External Fixation System. External Fixation. Operative Technique

VLIFT System Overview. Vertebral Body Replacement System

External Distal Radius Fixator. Supplement to the 8 mm rod fixator system

Knee spanning solutions

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

Monolateral External Fixation System for Trauma and Orthopaedics

Mini External Fixator

AxSOS. Locking Plate System. Operative Technique. Small Fragment Basic Fragment

Large External Fixator Modular Knee Bridge

CMF. Maxillofacial portfolio

Low-Profile Wrist Fixator. For stabilization of fractures of the distal radius.

Craniomaxillofacial. Universal Trocar System

System. Humeral Nail. Surgical Technique

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

TRIAX EXTERNAL FIXATION SYSTEM

Surgical Technique. 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plates

Medical Devices HUMERUS. WRIStX

Clinical. Solutions. Synthes Solutions. Foot and Ankle.

Collinear Reduction Clamp

MEFiSTO. Monolateral External Fixation System for Trauma and Orthopaedics.

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Foot & Ankle. Smart Toe II. Intramedullary Implant. Operative Technique. Foot & Ankle

External Fixator Brochure

Asnis III. Cannulated Screw System. Operative Technique. 4.0mm 5.0mm 6.5/8.0mm. Shoulder. Elbow. Hand & Wrist. Hip. Pelvis. Femur.

For Small-Statured Adults and Pediatric Patients. Medium External Fixator Basic Modular Frame

Intra Medullary Interlocking Nailing System

Elbow Hinge Fixator. Guided Flexion/Extension for Unstable Elbow Fractures.

VariAx Compression Plating System. Operative technique

Asnis III Cannulated Screw System. Operative technique

NeuroMend. Collagen Wrap Conduits. Operative Technique

VariAx Distal Radius Locking Plate System

LCP Metaphyseal Plates. For extra-articular fractures.

MEFiSTO. Monolateral External Fixation System for Trauma and Orthopaedics.

SMARTLockTM. Hybrid MMFTM

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

pediatric orthopedic implants fixator

Leibinger Next Generation Universal Trocar System

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

Hybrid Fixator Proximal Tibia Frame. Using rings with clamps.

Mandible Reconstruction Module Reference ence Guide

Surgical Technique. Targeter Systems Overview

Asnis III Cannulated Screw System

MatrixNEURO. The next generation cranial plating system.

LOW PROFILE NEURO. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Complex process High costs

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates

TIPMED EXTERNAL FIXATION SYSTEMS

Low Profile Neuro Plating System. Surgical Technique

Small External Fixator Nonspanning Wrist Frame. For the treatment of wrist fractures.

Femur Condylar Plate System Procedural Steps.

Technique Guide. The Distraction Osteogenesis Ring System. Nonarticular tibia frame.

AxSOS 3 Titanium Proximal Lateral Humerus Locking Plate System. Operative technique

QUICK REFERENCE GUIDE. The PreFix Fixator (92000 Series) ALWAYS INNOVATING

INnate. Surgical Technique Guide. Anatomic Fixation in Your Hands. The INnate Implant

Foot & Ankle. EasyClip. Osteosynthesis Compression Staples. Foot & Ankle

External Skeletal Fixation (ESF)

Mini External Fixator.

Handling Technique. Collinear Reduction Clamp. For minimally invasive fracture reduction.

Complex process High costs

A Legacy of Serving the Surgical Community

Correction System. Surgical Technique

VariAx Elbow Locking Plate System

EXTERNAL FIXATION SYSTEM OPERATIVE TECHNIQUE

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

Asnis. Micro Cannulated screw system. Xpress operative technique

SpeedTip CCS 2.2, 3.0

TransFx External Fixation System Large and Intermediate Surgical Technique

Asnis III Cannulated Screw System

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

Technique Guide Hammertoe Correction System

2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the Synthes locking compression plate (LCP) system.

The Calcaneal Plate. The Synthes non-locking solution for the Calcaneus.

Mandible External Fixator II

VersiTomic Flexible Reaming System

Transcription:

Hoffmann II MRI External Fixation Systems Hoffmann II MRI Hoffmann II Compact MRI Modular Systems for Upper Extremity Lower Extremity Pelvis

Introduction In the ever changing world of medicine, new technology is advancing the treatment of the patient. The Magnetic Resonance Imaging (MRI) scanner uses electromagnetic fields to make exact images of the human body. More and more hospitals are investing in MRI suites and using the MRI scanners on a routine basis to more accurately assess their patients. For this reason, Stryker offers a line extension of External Fixation which may be used safely in MRI scanners up to 3.0 Tesla 1. This means that the patient can be placed in the MRI scanner with the fixator in situ without additional risk for the patient or the MRI scanner itself. With non MRI safe fixators, the patient can be injured in two ways. The static magnetic field generated by MRI systems will attract ferromagnetic objects with considerable force. This can lead to displacement of the components which can cause serious injuries to the patient and damage to the scanner. In addition to this, conductive devices may experience heating by the induction of electromotive forces when subjected to gradient magnetic fields. This can lead to temperature increases of the fixator pins which can be significant and reach critical levels. These increases may cause patient discomfort and may even lead to bone necrosis. The engineers at Stryker have created MRI systems which are made of nonferromagnetic and non-conductive materials. This allows the surgeon to build any size or type of frame construct with no additional risk for the patient in an MRI environment up to 3.0 Tesla. Image is showing the magnet resonance tomograph Magnetom Avanto by Siemens AG Medical 1 1.5 and 3.0 Tesla Test Data with specific conditions on file at Stryker Trauma AG

Features & Benefits Versatility and Ease-of-Use are the keys to an effective external fixator. Whether it is middle-of-the-night trauma, or a complicated fracture with associated softtissue damage, the Hoffmann II MRI product family gives the surgeon the right tools to resolve even the most difficult cases. With the patented Snap-Fit Technology, stable frame building is simple. It is possible to reduce the fracture, make post-operative corrections, and treat soft-tissue damage with the frame in situ. The non-ferromagnetic components are Color-Coded and there are just a handful of High Quality Instruments in the system. This makes the product very manageable in the Operating Room. Patented Light-Weight and Advanced composite materials are nonferromagnetic and non-conductive. You can create a Low-Profile, Radiolucent Frame which can be used in the MRI Scanner. With full Independent Pin Placement, you can easily build a frame to treat fractures close to a joint or to stay clear of damaged soft-tissue areas. Note: Refer to the Standard Hoffmann II and Hoffmann II Compact Systems for a detailed Operative Technique, since these systems function in the same way in the operating theater.

Technical Details - Hoffmann II MRI Color Code Guidelines for Safe MRI Procedures The color coding of the Hoffmann II MRI system will help you ensure that the frame you build may be used for MRI procedures. Since the dimensions are virtually the same between the Hoffmann II and Hoffmann II MRI, it is important to understand and follow the color code scheme to avoid any possible mixup of components leading to patient injury. All of the tightening bolts have a GOLD head All of the clamps and couplings contain the color GREEN. All of the 30 Angled Posts have a GOLD tip All MRI components have MRI engraved on them.

Technical Details - Hoffmann II Compact MRI Hoffmann II Compact MRI also has color coding to distinguish it from the standard Hoffmann II Compact System. The 4-Hole Pin Clamp and couplings contain the color ORANGE. Peri-Articular Pin Clamp has a GOLD post. All of the tightening bolts have a GOLD head. All MRI components have MRI engraved on them. All of the 30 Angled Posts have a GOLD tip

Technical Details MRI Carbon Connecting Rods and Tubes The rods are color-coded in YELLOW for easy recognition. The Hoffmann II MRI System uses Ø8mm rods, and the Hoffmann II Compact MRI uses Ø5mm rods. The Carbon Connecting Rods in the MRI systems have been specially designed to be non-conductive and non-ferromagnetic. They are coated with a patented electricity-insulating material. This means that no induced current can be carried through any frame built with MRI components. To guarantee non-conductivity, the rods are single-use. Note: The Standard Hoffmann II and Hoffmann II Compact Carbon and Aluminium Rods are not MRI safe because they are made from conductive materials. The Stainless Steel Rods are not MRI safe because they are both conductive and ferromagnetic. When using the non-conductive rods and non-ferromagnetic components, you can be assured that the patient is at no risk undergoing an MRI procedure due to the fixator 1. The Hoffmann II MRI System offers two types of Ø20mm tubes: a Compression/Distraction Tube and a Dynamization Tube. They are color coded in GREEN. The Hoffmann II Compact MRI System offers a Ø15mm Compression/ Distraction Tube, which is color coded in ORANGE.

Technical Details Apex Pins Apex Pins have always been and will continue to be safe for MRI procedures up to 3.0 Tesla. There is a common misconception that all stainless steel parts are ferromagnetic and therefore not MRI safe. All of Stryker s pins are made of high-quality non-ferromagnetic surgical stainless steel or titanium. There are four different types of pins that can be used with Stryker external fixation components. Note: The MRI Hoffmann II Systems can only be guaranteed for MRI use when using Stryker s Apex Pins to build frames. These pins come in a variety of diameters, total lengths, and thread lengths. Self-Drilling Pin Blunt Pin Cancellous Pin Transfixing Pin Related Stryker Products The system can be used together with other Stryker systems to give the surgeon the Full Package of fracture treatment. SPS Small and Basic Fragment Plating Systems ASNIS III Cannulated Screws T2 Nailing Systems

Ordering Information - Components REF Description Hoffmann II MRI Components 4921-2-020 5-Hole Pin Clamp for Ø4, Ø5, and Ø6mm pins 4921-2-060 10-Hole Pin Clamp for Ø4, Ø5, and Ø6mm pins 4921-2-080 Pelvic Clamp for Ø4, Ø5, and Ø6mm pins 4921-1-010 Rod to Rod Coupling for Ø8mm rods or posts 4921-1-020 Pin to Rod Coupling for Ø4-5mm pins/ø8mm rods or posts 4921-1-030 Inverted Pin to Rod Coupling for Ø8mm rods or posts/ø4-5mm pins 4921-1-100 Tube to Rod Coupling for Ø20mm tubes/ø8mm rods or posts 4921-2-140 30 Angled Post Ø8mm 4921-2-120 Straight Post Ø8mm Hoffmann II MRI Ø20mm Tube 4921-0-000 Dynamization Tube 4921-0-015 Compression/Distraction Tube Ø8mm Rods 5028-8-065 Carbon Connecting Rod 65mm 5028-8-100 Carbon Connecting Rod 100mm 5028-8-150 Carbon Connecting Rod 150mm 5028-8-200 Carbon Connecting Rod 200mm 5028-8-250 Carbon Connecting Rod 250mm 5028-8-300 Carbon Connecting Rod 300mm 5028-8-350 Carbon Connecting Rod 350mm 5028-8-400 Carbon Connecting Rod 400mm 5028-8-450 Carbon Connecting Rod 450mm 5028-8-500 Carbon Connecting Rod 500mm 174mm (L) 5028-7-030 Semi-Circular Carbon Rod 174mm (L)

Ordering Information - Instruments REF Description Hoffmann II Instruments for MRI System (not for use in the MRI suite) 4920-9-010 Stabilization/Reduction Wrench 4920-9-020 Thumbwheel 4920-9-030 7mm T-Wrench/Ø5-6mm Pin Inserter 5054-8-009 7mm Spanner Wrench 4921-9-984 Storage Case Lid 4921-9-983 Storage Case Upper Insert 4921-9-982 Storage Case Lower Insert 4921-9-981 Storage Case Base

Ordering Information - Components REF Description Hoffmann II Compact MRI Components 4941-2-020 4-Hole Pin Clamp for Ø3 and Ø4mm pins 4941-2-200 Peri-Articular Pin Clamp for Ø3mm pins 4941-1-010 Rod to Rod Coupling for Ø5mm rods or posts 4941-1-020 Pin to Rod Coupling for Ø5mm rods or posts/ø3-4mm pins 4941-1-058 Rod to Rod Coupling for Ø8mm rods or posts/ø5mm rods or posts 4941-1-100 Tube to Rod Coupling for Ø15mm tube/ø5mm rods or posts 4941-2-140 30 Angled Post Ø5mm 4941-2-120 30 Angled Post Ø5mm Hoffmann II Compact MRI Ø15mm Tube 4941-0-015 Compression/Distraction Tube Ø5mm Rods 5048-5-065 Carbon Connecting Rod 65mm 5048-5-100 Carbon Connecting Rod 100mm 5048-5-150 Carbon Connecting Rod 150mm 5048-5-200 Carbon Connecting Rod 200mm 5048-5-250 Carbon Connecting Rod 250mm 5048-5-300 Carbon Connecting Rod 300mm 10

Ordering Information - Instruments REF Description Hoffmann II Compact Instruments for MRI System (not for use in the MRI suite) 4940-9-010 Stabilization/Reduction Wrench 4920-9-020 Thumbwheel 4940-9-030 5mm Wrench/Ø3-4mm Pin Driver 5150-9-005 5mm Spanner Wrench 4941-9-923 Storage Case Lid 4941-9-922 Storage Case Insert 4941-9-921 Storage Case Base 11

Trauma, Extremities & Deformities Biologics Surgical Products Neuro & ENT Stryker Trauma AG Bohnackerweg 1 CH-2545 Selzach Switzerland www.osteosynthesis.stryker.com The information presented in this brochure is intended to demonstrate a Stryker product. Always refer to the package insert, product label and/or user instructions before using any Stryker product. Surgeons must always rely on their own clinical judgment when deciding which products and techniques to use with their patients. Products may not be available in all markets. Product availability is subject to the regulatory or medical practices that govern individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. Stryker Corporation or its subsidiary owns the registered trademark: Stryker Stryker Corporation or its subsidiary owns, uses or has applied for the following trademarks: Hoffmann, Compact, T2, Apex, Asnis III Literature Number: 5075-1-600 LOT B3606 Copyright 2006 Stryker Printed in Germany