Simplifying Solid-Phase Extraction [ OASIS SOLID-PHASE EXTRACTION PRODUCTS ]

Similar documents
Taking the Complexity out of SPE Method Development

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Sample Preparation. Sample Preparation. We are focused on quality and reproducibility. ~ Pat Curtis, Principal Process Chemist, Wexford, Ireland

Performance of an ultra low elution volume 96-well plate

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE)

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Transforming Sample Preparation Xin Zhang Senior Research Chemist

Protect Your Mass Spec

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

PosterREPRINT INTRODUCTION. 2-D PAGE of Mouse Liver Samples. 2-D PAGE of E.coli Samples. Digestion / Cleanup. EXPERIMENTAL 1-D PAGE of BSA Samples

[ APPLICATION NOTE ] Oasis PRiME HLB Cartridge for Cleanup of Infant Formula Extracts Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis

Quantification of Budesonide Using UPLC and Xevo TQ-S

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

Transforming Sample Preparation Introducing Waters Newest Solid Phase Extraction Product

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

Improving Food Process Control Using the

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

ApplicationNOTE A MULTI-RESIDUE LC/MS/MS METHOD FOR THE DETERMINATION OF 81 PESTICIDE RESIDUES IN FRUIT AND VEGETABLES: PART 1, METHOD OVERVIEW

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

[ Care and Use Manual ]

LC-MS/MS Method for the Determination of Tenofovir from Plasma

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Filtration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products

Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD

Development of a High Sensitivity SPE-LC-MS/MS Assay for the Quantification of Glucagon in Human Plasma Using the ionkey/ms System

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology

A New Era in SFC Column Technology

Systematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs

Core-Shell Technology for Proteins and Peptides

Keep it Clean with Strata -X

Reducing Sample Volume and Increasing Sensitivity for the Quantification of Human Insulin and 5 Analogs in Human Plasma Using ionkey/ms

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Phospholipid Removal Solutions

A High Sensitivity UPLC/MS/MS Method for the Analysis of Clopidogrel and Clopidogrel Carboxylic Acid Metabolite in Human K 2 EDTA Plasma

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Simultaneous Analysis of Intact Human Insulin and Five Analogs in Human Plasma Using μelution SPE and a CORTECS UPLC Column

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

The Raptor HILIC-Si Column

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

Supra-Clean and Supra-Poly Solid Phase Extraction (SPE) Solutions

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

USP Method Transfer of Ziprasidone HCl from HPLC to UPLC

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

GlycoWorks Sample Preparation Consumables

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link System. Fully-Automated HbA 1c Testing

Determination of Pharmaceutical Residues in Bovine Milk via LC MS/MS Following Solid Phase Extraction

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link. Fully-Automated HbA 1c Testing

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Bio-Rad Laboratories. Hemoglobin Testing. VARIANT II Hemoglobin Testing System For HbA 1c

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Noora Perkola Finnish Environment Institute. Nordic MS Symposium November 9, 2011, Båstad, Sweden

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Dienes Derivatization MaxSpec Kit

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Rapid and Robust Detection of THC and Its Metabolites in Blood

Challenges in Developing an Ultra-Sensitive Bioanalytical Method for Ethinylestradiol in Human Plasma

Corticosteroids. Optimizations. Jens Hinge Andersen. National Food Institute Danish Technical University

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Comparison of a UPLC Method across Multiple UHPLC Systems

Finally, a Solid Phase Extraction product for Drugs of Abuse

Application Note. Author. Abstract. Introduction. Food Safety

The first and only fully-automated, multiplexed solution for Measles, Mumps, Rubella and Varicella-zoster virus antibody testing

Cardiac Assessment Controls

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS

Ultra Columns. also available. ordering note

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

Author. Introduction. Small Molecule Pharmaceuticals & Generics

Overview of Matrix Effects in Bioanalysis

The Development of LC/MS Methods for Determination of MDMA (Ecstasy) and Metabolites in Biological Samples

SPME-LC Fibers for a Variety of Applications

Powerful Sample Prep and LC Column Solutions for Forensic Toxicology Applications

Strata -X Polymeric SPE

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

Comparison of Simultaneous Nitrofuran (NF) and Chloramphenicol (CAP) Analytical Methods for AOAC Validation Study

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Transcription:

Simplifying Solid-Phase Extraction [ OASIS SOLID-PHASE EXTRACTION PRODUCTS ]

Through the combination of innovative sorbent technology and hardware design, Oasis Products have become the first choice in solid-phase extraction (SPE). Oasis Products are trusted by separation scientists across the globe to meet a wide variety of sample preparation needs, ranging from a simple and fast matrix cleanup to the need to solve the most difficult and highly selective sample preparation challenges. Researchers rely on the superior technical performance of Oasis Products to achieve unmatched purity, consistency, and quality in their sample preparation methods. * U.S. patents 5,882,521 (1996), 5,976,376 (1998), 6,106,721 (1999), 6,254,780 (2001), 6,322,695 (2001), 6,468,422 (2002), 6,726,842 (2004), 6,773,583 (2004), 6,723,236 (2004) 2

[ OASIS SOLID-PHASE EXTRACTION PRODUCTS ] Fastest and simplest methods leading to the cleanest samples Highest sensitivity for small molecules and therapeutic peptides Reduced matrix effects for LC-MS/MS analyses Unsurpassed selectivity Highest SPE recovery Exceptional product quality and reproducibility Wide selection of sorbents Broad array of formats 3

Oasis HLB Simplifying Solid-Phase Extraction Hydrophilic-Lipophilic Balanced Copolymer Waters introduced Oasis HLB in 1996, effectively changing the way scientists performed solid-phase extraction (SPE), as well as their expectations of this process. Constructed with a water-wettable copolymer that is stable from ph 0 14, Oasis HLB created a whole new range of solid-phase extraction method development possibilities. It is the gold standard in reversed-phase SPE, trusted by scientists across the world. Hydrophilic monomer Retention of polars Lipophilic monomer Reversed-phase retention Traditionally, solid-phase extraction methods have required condition and equilibration steps to prepare the sorbent for sample introduction. The condition step was required to wet the sorbent and allow liquid to enter the pores, enabling retention within the sorbent. Once wetted, the sorbent needed to be equilibrated with aqueous solution to prepare it for aqueous sample loading. Since Oasis HLB is a water-wettable sorbent, the analytes can interact with the sorbent and are retained when loaded directly onto the sorbent in an aqueous sample solution. This eliminates the condition and equilibration steps from the traditional solid-phase extraction protocol and reduces the number of processing steps from 5 to 3. The result is an average reduction in solvent consumption of up to 70% and a 40% savings in sample preparation time. Save Time and Solvent by Moving from a 5-Step Protocol to a 3-Step Protocol Standard (5-Step) Simplified (3-Step) 200 µl methanol (MeOH) Condition 200 µl H 2 O Equilibrate 200 µl spiked dilute plasma ( µl plasma + µl 4% H 3 PO 4 ) Load 200 µl spiked dilute plasma ( µl plasma + µl 4% H 3 PO 4 ) 200 µl 5% MeOH in H 2 O Wash 200 µl 5% MeOH in H 2 O 25 µl * 2 MeOH Elute 25 µl * 2 MeOH Traditional 5-step SPE protocol vs. the new 3-step SPE protocol with an Oasis HLB µelution Plate. (Typical loading range between 10 375 µl undiluted plasma.) 4

[ OASIS SOLID-PHASE EXTRACTION PRODUCTS ] The ability to simplify and shorten SPE protocols is due to the unique water-wettable, balanced nature of the hydrophilic/lipophilic Oasis Sorbent. Silica-based sorbents and other Oasis-like polymeric sorbents that are not as water-wettable as Oasis HLB sacrifice performance when eliminating these condition and equilibration steps. The chart below illustrates the difference that a thoroughly water-wettable sorbent such as Oasis HLB can make in the implementation of this simplified, 3-step protocol. Oasis HLB is able to effectively retain a wide range of compounds without the condition and equilibration steps. The competitors polymeric sorbent and a silica based sorbent do not work in the absence of these steps. Simplify Solid-Phase Extraction Without Sacrificing Recovery HLB μelution plate Polymer-based μ plate tc 18 μelution plate 90 80 70 60 50 40 30 20 10 0 Azidothymidine (AZT) Propranolol 7-Hydroxycoumarin Phenacetin Protriptyline Amitriptyline Betamethasone Alprazolam Naproxen The percent recoveries for a diverse set of compounds remain high with Oasis HLB when the condition and equilibration steps are eliminated from the solid-phase extraction protocol. Under these same conditions, the silica based sorbent produces recoveries of less than 10 percent for all analytes. The polymeric based sorbent produces recoveries of less than 10% for 7 compounds and less than 20% and 50% for the other two compounds. Additional information can be found within these application notes: Application note A Simplified, Mixed-Mode Sample Preparation Strategy for Urinary Forensic Toxicology Screening by UPLC-MS/MS A Simplified, Solid-Phase Extraction (SPE) Protocol for Bioanalysis Using Oasis HLB Search by literature code at waters.com Literature code 720005290EN 720005140EN 5

Oasis PRiME HLB Oasis PRiME HLB is the first-of-its-kind SPE sorbent that sets the new performance standard for routine analyses. The unique, patent-pending Oasis PRiME HLB Sorbent provides cleaner samples in less time and with less effort. These powerful and easy-to-use benefits are important since solid-phase extraction provides many benefits when performed prior to chromatographic analyses, especially when using mass detection. These benefits include a reduction in matrix effects and chromatographic complexity as well as the ability to increase sample concentration. However, scientists also desire sample preparation methods that are SIMPLE to follow while providing CLEANER sample eluates in the FASTEST time possible. Based on Oasis HLB Technology, Oasis PRiME HLB was developed to meet these needs with a focus on these advantages: Simpler Faster Even Cleaner 6

[ OASIS SOLID-PHASE EXTRACTION PRODUCTS ] Simpler Easy, efficient protocols Oasis PRiME HLB was created to have the same powerful benefits made possible with Oasis HLB. The Oasis PRiME HLB Copolymer is extremely water-wettable, making it possible to eliminate the condition and equilibration steps that are required when using silica-based or other polymeric sorbents. Without these additional steps, sorbents that are not as water-wettable are unable to effectively retain analytes of interest during the sample load step, causing a loss of recovery. The ability to skip these steps saves valuable sample processing time and costly solvent purchase and disposal. Oasis PRiME HLB allows you to choose the sample preparation method that meets your analytical needs. The simplicity of the sorbent design and protocols makes it easy to implement into your laboratory's workflow without requiring solid-phase extraction expertise. 3-step protocol (catch and release SPE) Load pre-treated sample Wash: 5% MeOH Elute: 90/10 acetonitrile/meoh Use the 3-step solid-phase extraction protocol to remove the most matrix interferences, including salts, phospholipids, and proteins. This technique also allows for sample concentration/enrichment. It is the perfect solution for routine bioanalytical sample clean up or any other reversed-phase solid-phase extraction application. 2-step protocol (pass-through SPE) Load pre-treated sample Analytes pass-through unretained Rinse to collect hold up volume (optional) Use the 2-step solid-phase extraction protocol to remove matrix interferences quickly if your sample solution contains a high concentration of organic solvent(s) and concentration and/ or salt removal is not required. This protocol is perfectly suited for multiple residue screening of veterinary drugs, pesticides and mycotoxins in various food samples. 7

Faster Faster, more even flows across cartridges and plates with less plugging Oasis PRiME HLB has been designed to increase speed both within the SPE device itself and in your laboratory s sample processing workflow. Not only can you eliminate the condition and equilibration steps, viscous samples flow more easily through the cartridges and 96-well plates due to a new, optimized frit and sorbent design. Flow rates through the devices are much faster for common matrices such as plasma, urine, and milk. The optimal load, wash, and elution flow rates are achieved using less vacuum or positive pressure than with other SPE devices. Increased Sample Processing Speed with Oasis PRiME HLB Matrix Device Format Oasis PRiME HLB Speed Increase 1:1 Diluted Plasma µelution Plate 2 3x Faster 1:1 Diluted Plasma 1 cc/30 mg Cartridge 4x Faster 1:1 Diluted Urine 30 mg Plate 6x Faster 1:1 Diluted Urine 10 mg Plate 2x Faster 1:1 Diluted Milk 3 cc/60 mg Cartridge 1 2x Faster 1:1 Diluted Milk 6 cc/200 mg Cartridge 2 3x Faster Flow comparison vs. another reversed-phase SPE sorbent. Loading performed with 4 inch Hg (n=4). Faster processing time compared to other sample preparation techniques With the elimination of the condition and equilibration steps, Oasis PRiME HLB provides faster processing time compared to other sample preparation techniques such as solid-supported liquid extraction (SSLE). Scientists can achieve highly reproducible sample clean up with less process complexity and fewer steps. Reduce Sample Preparation Time and Steps with Oasis PRiME HLB Compared to SSLE SSLE 1. Add sample (3 min) 2. Wait (5 10 min) 3. Add extraction solvent (2 min) 4. Wait (5 10 min) 5. Extract (1 min) 6. Evaporate (5 min) 7. Reconstitute (2 min) Oasis PRiME HLB 1. Load pre-treated sample (4 min) 2. Wash: 5% MeOH (3.5 min) 3. Elute: 90/10 acetonitrile/meoh (2 min) TOTAL PROCESS- ING TIME: 9.5 min. TOTAL PROCESS- ING TIME: 28 33min. Oasis PRiME HLB reduces sample preparation time and complexity by providing efficient sample preparation. Compared to SSLE, samples can be processed in fewer steps and less time. 8

[ OASIS SOLID-PHASE EXTRACTION PRODUCTS ] Even Cleaner Oasis PRiME HLB removes more than 95% of common matrix interferences such as proteins, salts, and phospholipids, using the generic protocol without any additional optimization. Cleaner samples means less variability in your analytical results from sample to sample, increasing the robustness of your analyses. Phospholipids Remaining in Final Eluate 7000000 6000000 5000000 4000000 3000000 2000000 0000 0 Oasis PRiME HLB Competitor SX Competitor SO PPT 1:3 Plasma:ACN Fewer phospholipids remain in the final sample eluate with the Oasis PRiME HLB Sorbent and 3-step protocol, compared to the final eluates using traditional 5-step protocol on the competitors' sorbents. This removal is also more reproducible with Oasis PRiME HLB as indicated by the error bars (n=5). Food analysis can provide an exceptional challenge in sample preparation. Meat and milk samples are typically extracted with an acetonitrile based solvent for LC-MS determination of veterinary drug residues. Among the most significant co-extractable substances are fats and polar lipids, particularly phospholipids. For example, 1 ml of whole milk contains about 35 mg of fat and about 0.3 mg of phospholipids. A gram of pork muscle typically contains about mg of fat and about 5 mg of phospholipids. Reversed-phase sorbents such as C 18 are effective for removal of fat from the acetonitrile based extraction solvent, but are ineffective for removal of phospholipids. Excessive amounts of phospholipids can shorten LC column life and contribute to ion-suppression and contamination in the mass spectrometer. Oasis PRiME HLB is highly effective for removal of both phospholipids and fats from meat and milk extracts. Phospholipids Remaining After Pass-through Sample Clean Up Silica C 18 4.58 4.33 1: MRM of 12 Channels ES+ TIC (Phospholipid) 1.87e8 Oasis PRiME HLB 1: MRM of 12 Channels ES+ TIC (Phospholipid) 1.87e8 0% 1 2 3 4 5 6 min 1 2 3 4 5 6 min 0% 4.33 Lipid removal from acetonitrile-based meat extract results: Oasis PRiME HLB removes more than 90% of hexane-extractable total lipids (determined gravimetrically). Oasis PRiME HLB successfully removes both phospholipids and fats in pass-through method. The silica C 18 sorbent removes only fats, NOT phospholipids. Removal of both of these components results in fewer matrix effects and less column and/or instrument contamination. 9

Sorbents The Mixed-Mode Ion Exchange/Reversed-Phase Sorbents are all based on the Oasis HLB Copolymer to provide a range of options for method development. Oasis MCX Mixed-Mode Cation exchange sorbent for bases Oasis MAX Mixed-Mode Anion exchange sorbent for acids Oasis HLB Hydrophilic-Lipophilic Balanced reversed-phase sorbent for acids, bases, and neutrals pk a <1 Oasis WCX Hydrophilic Retention of Polars Mixed-Mode Weak Cation exchange sorbent for strong bases and quaternary amines Stable from ph 0 14 Water-wettable No silanol interactions Lipophilic RP Retention pk a >18 Oasis WAX Mixed-Mode Weak Anion exchange sorbent for strong acids pk a ~5 pk a ~ 6 Reduced Matrix Effects The presence of matrix interferences in a sample limits the maximum sensitivity that can be achieved. In addition, the removal of matrix interferences increases the robustness and reproducibility of your analytical results. Analyte % RSD of Matrix Factors Amitriptyline 6.03 Nortriptyline 5.53 Imipramine 8.36 Desipramine 7.15 Doxepin 5.96 Following extraction with an Oasis Mixed-Mode Sorbent, the matrix effects were evaluated for a panel of 5 antidepressant drugs in multiple lots of urine. The RSD of the matrix factors was determined to be between 5.5 and 8.4%, which is well within the 15% limit required by regulatory agencies. 10

[ OASIS SOLID-PHASE EXTRACTION PRODUCTS ] Sensitivity The Oasis Mixed-Mode Sorbents, which are all built upon the unique water-wettable Oasis HLB Copolymer, provide both reversed-phase and ion exchange modes of retention, enabling greater cleanup selectivity and sensitivity for both acidic and/or basic compounds. An example of this outstanding capability can be seen with the Oasis µelution Plate. This product employs a patented design to concentrate a sample up to 15x without requiring evaporation or reconstitution. 0% LOQ of Alprazolam from Plasma A. Matrix blank 1.54 1.58 1.62 1.66 1.70 1.74 1.78 min 1.61 B. 1 pg/ml spiked sample 0% 1.52 1.66 1.55 1.73 1.54 1.58 1.62 1.66 1.70 1.74 1.78 min LC-MS/MS chromatogram of 1 pg/ml of alprazolam from rat plasma. Bases pk a 2 10 OASIS MCX NEUTRALS Oasis 2 X 4 Method Development Protocol Strong Acids pk a <1.0 OASIS WAX 4-Step Protocol Load Pre-treated sample Wash 1 2% Formic acid Wash 2 or Elute 1 % MeOH Elute 2 5% NH 4 OH in MeOH Strong Bases pk a >10 OASIS WCX 4-Step Protocol Load Pre-treated sample Wash 5% NH 4 OH Elute % MeOH Elute 2 2% Formic Acid in MeOH Acids pk a 2 8 OASIS MAX NEUTRALS Selectivity Having a variety of tools for method development allows separation scientists to optimize their protocols to achieve maximum selectivity and sensitivity. Small molecules and therapeutic peptides require different approaches to sample preparation due to their solubilities and stabilities. Oasis SPE Products are available in a variety of sorbents and can be used in conjunction with a simple, logical approach to quickly develop new separation methods. Bases Strong Acids Strong Bases Acids * When using the µelution plate, perform the second elution using 5% NH 4 OH in 60:40 CH 3 CN:CH 3 OH (for protocol 1) and 2% HCOOH in 60:40 CH 3 CN:CH 3 OH (for protocol 2). 11

Peptides The increasing number of peptide based therapeutics brings new challenges to the typical bioanalytical laboratory. Sensitive, selective, and robust bioanalytical methods, which would ideally meet current regulatory criteria, must be developed for these types of compounds, which differ significantly from small molecule drugs. Because of their size and charge state distribution, sensitivity by mass spectrometry may be lower for biomolecules than typical small molecules, necessitating sample concentration and other means of increasing overall method sensitivity. We provide basic starting protocols for sample preparation and show how the use of mixed-mode ion-exchange solid-phase extraction in µelution format can simplify the process of method development for peptide therapeutics and biomarkers. Oasis µelution Plate technology for peptides enables: Up to 15x concentration without evaporation Concentration is often necessary to reach the limit of detection (LOD) with peptides Oasis WCX µelution PROTOCOL Oasis MAX µelution Dilute plasma with 4% H 3 PO 4 Condition MeOH/ Equilibrate H 2 0 Wash 1: 5% NH 4 OH Wash 2: 20% ACN Elute: 1% TFA in 75/25 ACN/H 2 O Dilute: H 2 O Helps minimize analyte loss Eliminates problems re-solubilizing peptides after dry-down steps Beneficial for thermally unstable peptides LOD and LOQ of Desmopressin from Plasma A. Matrix blank % A. Matrix blank 1.62 1.66 1.70 1.74 1.78 min 0 0.50 1.00 1.50 2.00 min 1.61 % 1.66 0 B. 1 pg/ml spiked sample 1.73 1.62 1.66 1.70 1.74 1.78 min 1.04 138 % Baseline x5 0 B. 1 pg/ml spiked sample 0.50 1.00 1.50 2.00 min 1.04 138 Baseline x5 0% B. 1 pg/ml spiked sample 0.50 1.00 1.50 2.00 min 1.04 765 Baseline x25 1.04 765 Baseline x25 C. 5 pg/ml spiked sample 0.50 1.00 1.50 2.00 min C. 5 pg/ml LC-MS/MS chromatogram of 1 pg/ml and 5 pg/ml of desmopressin from human plasma. spiked sample 12 0% 0.50 1.00 1.50 2.00 min

[ OASIS SOLID-PHASE EXTRACTION PRODUCTS ] Quality Waters expert manufacturing capabilities and stringent quality controls have established the highest standard in batch-to-batch and lot-to-lot reproducibility for SPE sorbents, enabling scientists to develop robust, accurate, and precise analytical methods. Scientists can be confident that the methods can be seamlessly transferred to laboratories across the globe. Recovery % No Batch Reservations Needed: Consistently high recoveries over more than 15 years of production. RSDs of recovery for: Procainamide: 1.90% Ranitidine: 1.68% Acetaminophen: 1.65% Formats µelution Plates Patented μelution plate design. Ideal for SPE cleanup and analyte enrichment of sample volumes ranging from 10 µl to 375 µl. No evaporation and reconstitution necessary due to elution volumes as low as 25 µl. Up to a 15x increase in concentration. Compatible with most liquid-handling robotic systems for automated, reliable high throughput SPE (HT-SPE). 96-well Extraction Plates Innovative, award-winning two-stage well design. High throughput and high recovery. Available with 5 mg, 10 mg, 30 mg, and 60 mg of sorbent per well. Compatible with most liquid-handling robotic systems for automated, reliable high throughput SPE (HT-SPE). Syringe-Barrel Cartridges Ultra-clean syringe barrel and frits. Available with cartridges ranging from 1 cc to 60 cc. Flangeless syringe-barrel cartridges available in 1 cc, 3 cc, and 6 cc configurations. Plus-style cartridges with Luer inlet hub and outlet tip with 225 mg of sorbent. Glass Cartridges Ultra-clean glass syringe with Teflon frit. For trace level detection and analysis at part-per-trillion levels. Available in 5 cc with 200 mg of sorbent configuration. On-Line Columns and Cartridges For rugged, reproducible, and ultra-fast on-line analysis. Wide choice of configurations, particle sizes, and sorbent chemistries. Available with six patented Oasis Sorbents HLB, PRiME HLB, MCX, MAX, WCX, and WAX. High recovery and reproducible results for a wide range of compounds. Cartridge format for use with Spark Holland Prospekt-2 /Symbiosis systems also available. 13

Oasis PRiME HLB Solid-Phase Extraction Products Description Format Qty. Part No. Oasis PRiME HLB µelution Plate 3 mg 1/pk 186008052 Oasis PRiME HLB 96-well Plate 10 mg 1/pk 186008053 Oasis PRiME HLB 96-well Plate 30 mg 1/pk 186008054 Oasis PRiME HLB Cartridge 1 cc/30 mg /box 186008055 Oasis PRiME HLB Cartridge 3 cc/60 mg /box 186008056 Oasis PRiME HLB Cartridge 3 cc/150 mg /box 186008717 Oasis PRiME HLB Cartridge 6 cc/200 mg 30/box 186008057 Oasis PRiME HLB Cartridge 6 cc/500 mg 30/box 186008718 Oasis PRiME HLB Plus Light Cartridge Plus Light/ mg 50/box 186008886 Oasis PRiME HLB Plus Short Cartridge Plus Light/335 mg 50/box 186008887 Oasis HLB Solid-Phase Extraction Products Description Format Particle Size Qty. Part No. Oasis HLB Cartridge 1 cc/10 mg 30 µm /box 186000383 Oasis HLB Cartridge 1 cc/30 mg 30 µm /box WAT094225 Oasis HLB Cartridge 1 cc/30 mg 30 µm 1,000/box 186003908 Oasis HLB Flangeless Cartridge 1 cc/30 mg 30 µm /box 186001879 Oasis HLB Cartridge with Gilson ASPEC adapter 1 cc/10 mg 30 µm 500/box 186000988 Oasis HLB Cartridge with Gilson ASPEC adapter 1 cc/30 mg 30 µm 500/box WAT058882 Oasis HLB Cartridge 3 cc/60 mg 30 µm /box WAT094226 Oasis HLB Cartridge 3 cc/60 mg 30 µm 1,000/box 186007646 Oasis HLB Flangeless Cartridge 3 cc/60 mg 30 µm /box 186001880 Oasis HLB Cartridge with Gilson ASPEC adapter 3 cc/60 mg 30 µm 500/box WAT058883 Oasis HLB Cartridge 6 cc/200 mg 30 µm 30/box WAT106202 Oasis HLB Cartridge 3 cc/400 mg 60 µm /box 186003849 Oasis HLB Cartridge 3 cc/540 mg 60 µm /box 186004134 Oasis HLB Flangeless Cartridge 3 cc/540 mg 60 µm /box 186003852 Oasis HLB Cartridge 6 cc/150 mg 30 µm 30/box 186003365 Oasis HLB Cartridge 6 cc/150 mg 60 µm 30/box 186003379 Oasis HLB Cartridge 6 cc/500 mg 60 µm 30/box 186000115 Oasis HLB Cartridge 12 cc/500 mg 60 µm 20/box 186000116 Oasis HLB Cartridge 20 cc/1 g 60 µm 20/box 186000117 Oasis HLB Cartridge 35 cc/6 g 60 µm 10/box 186000118 Oasis HLB Plus Short Cartridge 225 mg 60 µm 50/box 186000132 Oasis HLB Plus Light Cartridge 30 mg 30 µm 50/box 186005125 Oasis HLB Vac RC Cartridge 20 cc/30 mg 30 µm 50/box 186000382 Oasis HLB Vac RC Cartridge 20 cc/60 mg 30 µm 50/box 186000381 Oasis HLB Glass Cartridge 5 cc/200 mg 60 µm 30/box 186000683 Oasis HLB µelution Plate 2 mg/96-well 30 µm 1/pk 186001828BA Oasis HLB Plate 5 mg/96-well 30 µm 1/pk 186000309 Oasis HLB Plate 10 mg/96-well 30 µm 1/pk 186000128 Oasis HLB Plate 30 mg/96-well 30 µm 1/pk WAT058951 Oasis HLB Plate 60 mg/96-well 60 µm 1/pk 186000679 Oasis MAX Solid-Phase Extraction Products (Anion Exchange) Description Format Particle Size Qty. Part No. Oasis MAX Cartridge 1 cc/10 mg 30 µm /box 186004649 Oasis MAX Cartridge 1 cc/30 mg 30 µm /box 186000366 Oasis MAX Flangeless Cartridge 1 cc/30 mg 30 µm /box 186001883 Oasis MAX Cartridge 3 cc/60 mg 30 µm /box 186000367 Oasis MAX Cartridge 3 cc/60 mg 60 µm /box 186000368 Oasis MAX Flangeless Cartridge 3 cc/60 mg 30 µm /box 186001884 Oasis MAX Cartridge 6 cc/150 mg 30 µm 30/box 186000369 Oasis MAX Cartridge 6 cc/150 mg 60 µm 30/box 186000370 Oasis MAX Cartridge 6 cc/500 mg 60 µm 30/box 186000865 Oasis MAX Plus Short Cartridge 225 mg 60 µm 50/box 186003517 Oasis MAX Vac RC Cartridge 20 cc/30 mg 30 µm 50/box 186000372 Oasis MAX Vac RC Cartridge 20 cc/60 mg 30 µm 50/box 186000371 Oasis MAX Vac RC Cartridge 20 cc/60 mg 60 µm 50/box 186000378 Oasis MAX Solid-Phase Extraction Products (Anion Exchange) Continued Description Format Particle Size Qty. Part No. Oasis MAX µelution Plate 2 mg/96-well 30 µm 1/pk 186001829 Oasis MAX Plate 10 mg/96-well 30 µm 1/pk 186000375 Oasis MAX Plate 30 mg/96-well 30 µm 1/pk 186000373 Oasis MAX Plate 60 mg/96-well 30 µm 1/pk 186001256 Oasis MAX Plate 60 mg/96-well 60 µm 1/pk 186001205 Oasis MCX Solid-Phase Extraction Products (Cation Exchange) Description Format Particle Size Qty. Part No. Oasis MCX Cartridge 1 cc/10 mg 30 µm /box 186004648 Oasis MCX Cartridge 1 cc/30 mg 30 µm /box 186000252 Oasis MCX Flangeless Cartridge 1 cc/30 mg 30 µm /box 186001881 Oasis MCX Cartridge 1 cc/30 mg 60 µm /box 186000782 Oasis MCX Cartridge 3 cc/60 mg 30 µm /box 186000254 Oasis MCX Flangeless Cartridge 3 cc/60 mg 30 µm /box 186001882 Oasis MCX Cartridge 3 cc/60 mg 60 µm /box 186000253 Oasis MCX Cartridge 6 cc/150 mg 30 µm 30/box 186000256 Oasis MCX Cartridge 6 cc/150 mg 60 µm 30/box 186000255 Oasis MCX Cartridge 6 cc/500 mg 60 µm 30/box 186000776 Oasis MCX Cartridge 20 cc/1 g 60 µm 20/box 186000777 Oasis MCX Cartridge 35 cc/6 g 60 µm 10/box 186000778 Oasis MCX Plus Short Cartridge 225 mg 60 µm 50/box 186003516 Oasis MCX Vac RC Cartridge 20 cc/60 mg 30 µm 50/box 186000261 Oasis MCX Vac RC Cartridge 20 cc/60 mg 60 µm 50/box 186000380 Oasis MCX µelution Plate 2 mg/96-well 30 µm 1/pk 186001830BA Oasis MCX Plate 10 mg/96-well 30 µm 1/pk 186000259 Oasis MCX Plate 30 mg/96-well 30 µm 1/pk 186000248 Oasis MCX Plate 30 mg/96-well 60 µm 1/pk 186000250 Oasis MCX Plate 60 mg/96-well 60 µm 1/pk 186000678 Oasis WCX Solid-Phase Extraction Products (Weak Cation Exchange) Description Format Particle Size Qty. Part No. Oasis WCX Cartridge 1 cc/10 mg 30 µm /box 186004650 Oasis WCX Cartridge 1 cc/30 mg 30 µm /box 186002494 Oasis WCX Cartridge 3 cc/60 mg 30 µm /box 186002495 Oasis WCX Cartridge 6 cc/150 mg 30 µm 30/box 186002498 Oasis WCX Cartridge 1 cc/30 mg 60 µm /box 186002496 Oasis WCX Cartridge 3 cc/60 mg 60 µm /box 186002497 Oasis WCX Cartridge 6 cc/500 mg 60 µm 30/box 186004646 Oasis WCX Plus Short Cartridge 225 mg 60 µm 50/box 186003518 Oasis WCX µelution Plate 2 mg/96-well 30 µm 1/pk 186002499 Oasis WCX 96-well Plate 10 mg/96-well 30 µm 1/pk 186002501 Oasis WCX 96-well Plate 30 mg/96-well 30 µm 1/pk 186002503 Oasis WAX Solid-Phase Extraction Products (Weak Anion Exchange) Description Format Particle Size Qty. Part No. Oasis WAX Cartridge 1 cc/10 mg 30 µm /box 186004651 Oasis WAX Cartridge 1 cc/30 mg 30 µm /box 186002489 Oasis WAX Cartridge 3 cc/60 mg 30 µm /box 186002490 Oasis WAX Cartridge 6 cc/150 mg 30 µm 30/box 186002493 Oasis WAX Cartridge 1 cc/30 mg 60 µm /box 186002491 Oasis WAX Cartridge 3 cc/60 mg 60 µm /box 186002492 Oasis WAX Cartridge 6 cc/500 mg 60 µm 30/box 186004647 Oasis WAX Plus Cartridge 225 mg 60 µm 50/box 186003519 Oasis WAX µelution Plate 2 mg/96-well 30 µm 1/pk 186002500 Oasis WAX 96-well Plate 10 mg/96-well 30 µm 1/pk 186002502 Oasis WAX 96-well Plate 30 mg/96-well 30 µm 1/pk 186002504 Oasis WAX 96-well Plate 60 mg 30 µm 1/pk 186003915 14

[ OASIS SOLID-PHASE EXTRACTION PRODUCTS ] Oasis Method Development Kits Description Format Particle Size Part No. Oasis Sorbent Selection Plate, 3 rows each: MCX, MAX, WCX, and WAX 10 mg/96-well 30 µm 186003249 Oasis µelution Sorbent Selection Plate, 3 rows each: MCX, MAX, WCX, and WAX 2 mg/96-well 30 µm 186004475 Oasis Sorbent Selection Cartridge Kit, 10 each: MCX, MAX, WCX, and WAX 1 cc/30 mg 30 µm 186003463 Oasis Sorbent Selection Flangeless Cartridge Kit, 10 each: MCX, MAX, WCX, and WAX 1 cc/10 mg 30 µm 186006344 Oasis Sorbent Selection Flangeless Cartridge Kit, 10 each: MCX, MAX, WCX, and WAX 1 cc/30 mg 30 µm 186006345 Therapeutic Peptide Method Development Kits Description UPLC Therapeutic Peptide Method Development Kit Includes: 1 Oasis Peptide Method Development 96-well µelution Plate, (part no.: 186004713) 1 ACQUITY UPLC Peptide BEH C 18, 300Å, 1.7 µm, 2.1 x 50 mm Column, (part no.: 186003685) 3 96-well 1 ml Collection Plate and Cap Mat, (part no.: 600001043) HPLC Therapeutic Peptide Method Development Kit Includes: 1 Oasis Peptide Method Development 96-well µelution Plate, (part no.: 186004713) 1 XBridge Peptide BEH C 18, 300Å, 3.5 µm, 2.1 x 50 mm Column, (part no.: 186003607) 3 96-well 1 ml Collection Plate and Cap Mat, (part no.: 600001043) Part No. 176001835 176001836 Oasis µelution 96-well Plates Description Particle Size Qty. Part No. Oasis PRiME HLB 1/pk 186008052 Oasis HLB 30 µm 1/pk 186001828BA Oasis MCX 30 µm 1/pk 186001830BA Oasis MAX 30 µm 1/pk 186001829 Oasis WCX 30 µm 1/pk 186002499 Oasis WAX 30 µm 1/pk 186002500 Oasis 96-well Plates Particle Size 5 mg/ 96-well 10 mg/ 96-well 30 mg/ 96-well 60 mg/ 96-well Description 1/pk 1/pk 1/pk 1/pk Oasis PRiME HLB 186008053 186008054 Oasis HLB 30 µm 186000309 186000128 WAT058951 Oasis HLB 60 µm 186000679 Oasis MCX 30 µm 186000259 186000248 Oasis MCX 60 µm 186000250 186000678 Oasis MAX 30 µm 186000375 186000373 186001256 Oasis MAX 60 µm 186001205 Oasis WCX 30 µm 186002501 186002503 Oasis WAX 30 µm 186002502 186002504 186003915 On-Line SPE Columns and Cartridge Columns Description Format Particle Size Qty. Part No. Oasis HLB Column 2.1 x 20 mm 5 µm 1/pk 186002034 Oasis HLB Column 3.0 x 20 mm 5 µm 1/pk 186002037 Oasis HLB Column 3.9 x 20 mm 5 µm 1/pk 186002040 Oasis HLB Cartridge Column 3.9 x 20 mm 5 µm 1/pk 186001413 Oasis HLB Column 4.6 x 20 mm 5 µm 1/pk 186002043 Oasis HLB Column 2.1 x 20 mm 15 µm 1/pk 186002035 Oasis HLB Column 3.0 x 20 mm 15 µm 1/pk 186002038 Oasis HLB Column 3.9 x 20 mm 15 µm 1/pk 186002041 On-Line SPE Columns and Cartridge Columns Continued Description Format Particle Size Qty. Part No. Oasis HLB Cartridge Column 3.9 x 20 mm 15 µm 1/pk 186001414 Oasis HLB Column 4.6 x 20 mm 15 µm 1/pk 186002044 Oasis HLB Column 2.1 x 20 mm 25 µm 1/pk 186002036 Oasis HLB Cartridge Column 2.1 x 20 mm 25 µm 1/pk 186000706 Oasis HLB Column 3.0 x 20 mm 25 µm 1/pk 186002039 Oasis HLB Column 3.9 x 20 mm 25 µm 1/pk 186002042 Oasis HLB Column 4.6 x 20 mm 25 µm 1/pk 186002045 Oasis HLB Direct Connect Column 2.0 x 15 mm 25 µm 1/pk 186001792 Oasis MCX Column 2.1 x 20 mm 30 µm 1/pk 186002046 Oasis MCX Cartridge Column 2.1 x 20 mm 30 µm 1/pk 186002051 Oasis MCX Column 3.0 x 20 mm 30 µm 1/pk 186002047 Oasis MCX Column 3.9 x 20 mm 30 µm 1/pk 186002048 Oasis MCX Column 4.6 x 20 mm 30 µm 1/pk 186002049 Oasis MAX Column 2.1 x 20 mm 30 µm 1/pk 186002052 Oasis MAX Cartridge Column 2.1 x 20 mm 30 µm 1/pk 186002057 Oasis MAX Column 3.0 x 20 mm 30 µm 1/pk 186002053 Oasis MAX Column 3.9 x 20 mm 30 µm 1/pk 186002054 Oasis MAX Column 4.6 x 20 mm 30 µm 1/pk 186002055 Oasis WCX Column 2.1 x 20 mm 30 µm 1/pk 186002505 Oasis WCX Column 3.9 x 20 mm 30 µm 1/pk 186002507 Oasis WAX Column 2.1 x 20 mm 30 µm 1/pk 186002508 Oasis WAX Column 3.9 x 20 mm 30 µm 1/pk 186002509 Oasis Symbiosis/Prospekt-2 Cartridges Description Format Particle Size Qty. Part No. Oasis HLB Symbiosis/Prospekt-2 Cartridge 1 x 10 mm 30 µm 96/box 186005781 Oasis HLB Symbiosis/Prospekt-2 Cartridge 1 x 20 mm 30 µm 96/box 186005786 Oasis MCX Symbiosis/Prospekt-2 Cartridge 1 x 10 mm 30 µm 96/box 186005782 Oasis MCX Symbiosis/Prospekt-2 Cartridge 1 x 20 mm 30 µm 96/box 186004653 Oasis MAX Symbiosis/Prospekt-2 Cartridge 1 x 10 mm 30 µm 96/box 186005783 Oasis MAX Symbiosis/Prospekt-2 Cartridge 1 x 20 mm 30 µm 96/box 186004654 Oasis WCX Symbiosis/Prospekt-2 Cartridge 1 x 10 mm 30 µm 96/box 186005784 Oasis WCX Symbiosis/Prospekt-2 Cartridge 1 x 20 mm 30 µm 96/box 186004655 Oasis WAX Symbiosis/Prospekt-2 Cartridge 1 x 10 mm 30 µm 96/box 186005785 Oasis WAX Symbiosis/Prospekt-2 Cartridge 1 x 20 mm 30 µm 96/box 186004656 SPE Columns for Waters UPLC with On-Line SPE Technology Description Format Particle Size Qty. Part No. Oasis HLB Direct Connect HP Column 2.1 x 30 mm 20 µm 1/pk 186005231 XBridge C 18 Direct Connect HP Column 2.1 x 30 mm 10 µm 1/pk 186005232 XBridge C 8 Direct Connect HP Column 2.1 x 30 mm 10 µm 1/pk 186005233 Oasis Bulk Material and Glass Cartridge Description Particle Size Qty. Part No. Oasis HLB 30 µm/ gm 186007549 Oasis HLB 30 µm/250 gm 186007550 Oasis MAX 30 µm/ gm 186007551 Oasis MAX 30 µm/250 gm 186007552 Oasis MCX 30 µm/ gm 186007553 Oasis MCX 30 µm/250 gm 186007554 Oasis HLB Glass Cartridge 60 µm 30/box 186000683 15

Sales Offices: Australia 61 2 9933 1777 Austria 43 1 877 18 07 Belgium and Luxembourg 32 2 726 0 Brazil 55 11 4134 3788 Canada 1 800 252 4752 China 86 21 6156 2666 Czech Republic 420 2 617 11384 Denmark 45 46 59 8080 Finland 358 9 5659 6288 France 33 1 30 48 72 00 Germany 49 6196 400 600 Hong Kong 852 2964 1800 Hungary 36 1 350 5086 India 91 080 49292200 03 Ireland 353 1 448 1500 Israel 9723 3731391 Italy 39 02 265 0983 Japan 81 3 3471 7191 Korea 82 2 6300 9200 Malaysia 603 7841 1688 Mexico 52 55 52 00 1860 The Netherlands 31 76 508 7200 Norway 47 6 384 6050 Poland 48 22 101 5900 Portugal 351 21 893 61 77 Puerto Rico 1 787 747 8445 Singapore 65 6593 7 Spain 34 93 600 9300 Sweden 46 8 555 115 00 Switzerland 41 56 676 7000 Taiwan 886 2 2508 5500 UAE 971 4 214 62 38 UK 44 208 238 6 US 1 800 252 4752 www.waters.com/oasis Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com Waters, The Science of What s Possible, UPLC, ACQUITY UPLC, XBridge, and Oasis are registered trademarks of Waters Corporation. Teflon is a registered trademark of E.I. du Pont de Nemours and Company or its affiliates. Prospekt and Symbiosis are trademarks of Spark Holland. All other trademarks are the property of their respective owners.. 2017 Waters Corporation. Printed in the U.S.A. June 2017 720001692EN KP-SIG 16