Similar documents

AUTHOR QUERIES - TO BE ANSWERED BY THE CORRESPONDING AUTHOR

HIGH SENSITIVE RADIATION DETECTOR FOR RADIOLOGY DOSIMETRY

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

Application of MCNP4C Monte Carlo code in radiation dosimetry in heterogeneous phantom

Inhomogeneity effect in Varian Trilogy Clinac ix 10 MV photon beam using EGSnrc and Geant4 code system

Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: a monte carlo study

PROCEDURE FOR ABSORBED DOSE TO WATER DETERMINATION IN HIGH ENERGY PHOTON AND ELECTRON BEAMS BY FERROUS SULPHATE DOSIMETER AT INMRI-ENEA

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

On the impact of ICRU report 90 recommendations on k Q factors for high-energy photon beams

Imaging of Radiation Dose Using Cherenkov Light

CHARACTERIZATION OF THE ELECTRON BEAM RADIATION FIELD BY CHEMICAL DOSIMETRY

EXPERIMENTAL RESULTS IN PERCENTAGE DEPTH DOSE (PDD) DETERMINATION AT THE EXTENDED DISTANCES *

Assessment of variation of wedge factor with depth, field size and SSD for Neptun 10PC Linac in Mashhad Imam Reza Hospital

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

Improving personal dosimetry of medical staff wearing radioprotective garments: Design of a new whole-body dosimeter using Monte Carlo simulations

Dosimetry Optimization System and Integrated Software (DOSIS): a comparison against Fluka code results over a standard phantom

Monte Carlo Modelling: a reliable and efficient tool in radiation dosimetry

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Dose differences between the three dose calculation algorithms in Leksell GammaPlan

Neutron dose evaluation in radiotherapy

DOSIMETRIC COMPARISION FOR RADIATION QUALITY IN HIGH ENERGY PHOTON BEAMS

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

Introduction. Measurement of Secondary Radiation for Electron and Proton Accelerators. Introduction - Photons. Introduction - Neutrons.

A preliminary clinic dosimetry study for synchrotron radiation therapy at SSRF

Protons Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry J. Phys.: Conf. Ser.

Optimization of the T2 parametric image map calculation in MRI polymer gel dosimetry

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

THERMOLUMINESCENT (TL) DOSIMETRY OF SLOW-NEUTRON FIELDS AT RADIOTHERAPY DOSE LEVEL

Response evaluation of CaSO4:Dy; LiF:Mg,Ti and LiF:Mg,Ti microdosimeters using liquid water phantom for clinical photon beams dosimetry

MODELLING A GAMMA IRRADIATION PROCESS USING THE MONTE CARLO METHOD

Radiochromic film dosimetry in water phantoms

Skin Model and its impact on Digital Mammography

IORT with mobile linacs: the Italian experience

Validation of the MC platform GATE for radiation therapy applications Evaluation of dose deposited by electrons. Yann Perrot, LPC, CNRS/IN2P3

[Setawati et. al., Vol.4 (Iss10): October, 2017] ISSN: DOI: /zenodo

Characterization and implementation of Pencil Beam Scanning proton therapy techniques: from spot scanning to continuous scanning

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Venue: IEEE NSS/MIC/RTSD Conference, Seoul, South Korea, 27 th October 2013 Workshop: NWK3/RD1 Radiation Protection and Dosimetry

Hampton University Proton Therapy Institute

EQUIVALENT DOSE FROM SECONDARY NEUTRONS AND SCATTER PHOTONS IN ADVANCE RADIATION THERAPY TECHNIQUES WITH 15 MV PHOTON BEAMS

M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

8/2/2018. Disclosures. In ICRU91: SRT = {SBRT/SABR, SRS}

CHEMICAL DOSIMETRY OF GAMMACELL WITH FERROUS SULFATE

SIMULATION RESPONSE OF RESISTIVE PLATE CHAMBER FOR FAST NEUTRONS USING GEANT4 MC CODE

Study of a spherical phantom for Gamma knife dosimetry

Dependence of the thermoluminescent high-temperature ratio (HTR) of LiF:Mg,Ti detectors on proton energy and dose

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

International Association of Scientific Innovation and Research (IASIR) (An Association Unifying the Sciences, Engineering, and Applied Research)

Epithermal neutron beams from the 7 Li(p,n) reaction near the threshold for neutron capture therapy

Leila E. A. Nichol Royal Surrey County Hospital

An anthropomorphic head phantom with a BANG polymer gel insert for dosimetric evaluation of IMRT treatment delivery

Neutron Interactions Part 2. Neutron shielding. Neutron shielding. George Starkschall, Ph.D. Department of Radiation Physics

Comparison of Energy Dependence of PAGAT Polymer Gel Dosimeter with Electron and Photon Beams using Magnetic Resonance Imaging

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Neutron Measurements for Intensity Modulated Radiation Therapy

Borges C 1, Zarza- Moreno M 2, Teixeira N 2, Vaz P 3 1

GDR in Radiotherapy Treatment Fields with 18 MV Accelerators

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Verification of Relative Output Factor (ROF) Measurement for Radiosurgery Small Photon Beams

Preliminary study of MAGAT polymer gel dosimetry for boron-neutron capture therapy

MAESTRO: Methods and Advanced Equipment for Simulation and Treatment in Radiation Oncology

Ion radiography as a tool for patient set-up & image guided particle therapy: a Monte Carlo study

Single Photon Emission Tomography Approach for Online Patient Dose Assessment in Boron Neutron Capture Therapy

Figure 1.1 PHITS geometry for PTB irradiations with: broad beam, upper panel; mono energetic beams, lower panel. Pictures of the setups and of the

Multilayer Gafchromic film detectors for breast skin dose determination in vivo

How accurately can we measure dose clinically? Accurate clinical dosimetry. Dosimetric accuracy requirement

IAEA-CN THE ESTRO-EQUAL RESULTS FOR PHOTON AND ELECTRON BEAMS CHECKS IN EUROPEAN RADIOTHERAPY BEAMS*

PREDICTION OF ABSORBED DOSE DISTRIBUTIONS AND NEUTRON DOSE EQUIVALENT VALUES IN PROTON BEAM RADIATION THERAPY

COMPARISON OF RADIOBIOLOGICAL EFFECTS OF CARBON IONS TO PROTONS ON A RESISTANT HUMAN MELANOMA CELL LINE

Diode calibration for dose determination in total body irradiation

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro

Limits of Precision and Accuracy of Radiation Delivery Systems

Comparison of microlion liquid filled ionisation chamber with Semiflex and Pinpoint air filled chambers

Energy dependent response of Al 2 O 3 and its potential application in personal monitoring.

Rotating and static sources for gamma knife radiosurgery systems: Monte Carlo studies

3-D dose verification by cone-beam optical CT scanning of PRESAGE dosimeter

DOSE MEASUREMENTS IN TELETHERAPY USING THERMOLUMINESCENT DOSIMETERS

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

Small field diode dosimetry

Calibration of TLD700:LiF for Clinical Radiotherapy Beam Modalities & Verification of a High Dose Rate Brachytherapy Treatment Planning System

Dosimetric Consideration in Diagnostic Radiology

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

Calculation methods in Hermes Medical Solutions dosimetry software

Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance

Non-target dose from radiotherapy: Magnitude, Evaluation, and Impact. Stephen F. Kry, Ph.D., D.ABR.

Real Time Spectrometer for thermal neutrons from Radiotherapic Accelerators

nuclear science and technology

Dosimetry in digital mammography

Abstract: A National Project for the in-vivo dosimetry in radiotherapy: first results

FLUKA Monte Carlo Simulation for the Leksell Gamma Knife Perfexion TM radiosurgery system

3D printing of air slab caps for correction free small field dosimetry. Benjamin Perrett, Paul Charles, Tim Markwell, Tanya Kairn, Scott Crowe

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

Plan-Specific Correction Factors for Small- Volume Ion Chamber Dosimetry in Modulated Treatments on a Varian Trilogy

Calibration of two 90 Sr+ 90 Y dermatological applicators

Transcription:

This article was published in an Elsevier journal. The attached copy is furnished to the author for non-commercial research and education use, including for instruction at the author s institution, sharing with colleagues and providing to institution administration. Other uses, including reproduction and distribution, or selling or licensing copies, or posting to personal, institutional or third party websites are prohibited. In most cases authors are permitted to post their version of the article (e.g. in Word or Tex form) to their personal website or institutional repository. Authors requiring further information regarding Elsevier s archiving and manuscript policies are encouraged to visit: http://www.elsevier.com/copyright

Nuclear Instruments and Methods in Physics Research A 5 (07) 2 5 www.elsevier.com/locate/nima An optimized Monte Carlo (PENELOPE) code for the characterization of gel-layer detectors in radiotherapy G. Castellano a,b,, D. Brusa a, M. Carrara c, G. Gambarini d, M. Valente d a FaMAF, National University of Cordoba, Argentina b CONICET, Argentina c Department of Medical Physics, National Cancer Institute of Milan, Italy d Physics Department, University of Milan and I.N.F.N., Italy Available online 24 May 07 Abstract Monte Carlo (MC) simulation of radiation transport is considered to be one of the most accurate methods of radiation therapy dose calculation. A basic requirement for MC treatment planning is a detailed knowledge of the characteristics of radiation beam generated from medical linear accelerators (LINACs). One of the most important input parameters is the photon fluence of the beam, usually not determinable experimentally. Thus, an MC simulation code based on the PENELOPE package was developed in order to survey the influence of the incident spectrum on the in-phantom dose distributions. Different spectra for the incident photon fluence have been considered in order to establish the most adequate one. The resulting planned dose distributions have been compared with those determined experimentally with ionization chamber measurements and gel dosimeter layers analyzed with optical technique. The specific gel composition has been implemented in the MC simulation code. Comparisons between experimental measurements, approximated simulations (water) and specific simulations (gel composition) have been performed. r 07 Elsevier B.V. All rights reserved. PACS: 87.53. j; 87.53.Dq; 02..Lq Keywords: Monte Carlo simulation; External radiotherapy; Fricke gel dosimetry 1. Introduction The assessment of radiation dose distribution in radiotherapy treatment planning should be quite accurate, since the dose delivered to patients must not differ more than 5% from the prescribed dose [1,2]. Although most threedimensional treatment planning system algorithms usually involve the pencil beam method [3], Monte Carlo (MC) simulation has increasingly become more important since several irradiation configurations can be simulated for dose distribution determinations. Utilization of MC codes has found an extensive application in radiation transport studies and also for dose distribution determinations in clinical dosimetry. In order Corresponding author. FaMAF, National University of Cordoba, Argentina. Tel.: +54 351 433 52; fax: +54 351 433 54. E-mail address: gcas@famaf.unc.edu.ar (G. Castellano). to simulate the irradiation situation corresponding to a typical commercial Linac therapy unit, PENELOPE MC package [4] has been employed. Fricke (ferrous-sulphate) layered-gel dosimeters imaged with an optical system have demonstrated to be a useful tool for dose distribution measurements in radiotherapy [5,6]. Briefly, the optical method used for Fricke gel dosimeter analysis is based on the imaging of visible light transmittance through the dosimeters, detected before and after irradiation. In order to perform optical transmittance analysis, gel dosimeters are in form of layers and they are placed on a plane and homogeneous illuminator. The images are detected by means of a CCD camera supplied with a suitable optical filter, giving a good spatial resolution for the dose distribution. A suitable dedicated MC subroutine has been adapted in order to check the tissue-equivalence of the here used Fricke gel dosimeters, for photon and electron beams. 0168-9002/$ - see front matter r 07 Elsevier B.V. All rights reserved. doi:10.1016/j.nima.07.05.215

G. Castellano et al. / Nuclear Instruments and Methods in Physics Research A 5 (07) 2 5 3 Therefore, exact knowledge of Fricke gel dosimeter chemical composition and dimensions allowed appropriate target material input, in order to define the dosimeter chemical and geometrical properties for the simulation code. 2. Materials and methods 2.1. Monte Carlo simulations The MC code used in this work has been adapted from the sample programs distributed with version 03 of the PENELOPE package. These FORTRAN 77 routines perform MC simulation of coupled electron photon transport in arbitrary materials. The scattering models included allow the simulation of electron, positron and photon transport in the energy range of 100 ev 1 GeV. Random electron photon showers are generated in complex material structures consisting of distinct homogeneous regions of different compositions. The main program has to control the evolution of the simulated tracks and keep score of the relevant quantities. Photon transport is simulated in a detailed way, which means that all the interaction events in a photon history are simulated in chronological succession. On the other hand, electron and positron tracks are simulated by means of a mixed algorithm: individual hard interactions are accounted for in a detailed way, whereas soft collisions are taken into account through condensed simulation, i.e., several interactions are grouped in one single event. This procedure ensures reliable simulation results, while saving simulation CPU time. The sample program PENCYL provided in the 03 PENELOPE distribution has been modified according the requirements of the actual situations to be reproduced. In order to allow a divergent rectangular beam, the developed program generates pseudo-random numbers to adequately cover the desired rectangular field area with the corresponding incident photon fluence. For each primary photon generated in this way, a proper incident direction is assigned following the source divergence. Different energy distributions for the incident photon beam have been considered. With the aim of achieving the most reliable situation, a typical bremsstrahlung spectrum has been taken into account as well as simplified cases, such as combinations of monoenergetic beam components. The main irradiated materials considered here have been two kinds of phantoms: the first one consisting of homogeneous water, while the second one reproduced the detailed chemical composition and geometry of the Fricke gel layer dosimeters described below. The simulations were carried out in a cluster facility with 3.0 MHz Pentium processors, each with 10 8 primary particles, which typically implied around 10 6 s of CPU time. 2.2. Experimental dosimeter characterization The elaboration process of gel dosimeters involves a Fricke (ferrous sulfate) solution infused with Xylenol Orange, which is incorporated to a gel matrix (porcine skin gelatin) as described in [6,7]. The mass chemical composition of the dosimeter sensitive volume is approximately: H, 11.04%; O, 88.42%; C, 0.04%; N, 0.002%; Fe, 0.003%; Na, 0.002% and S, 0.005%. Simulated and experimental relative dose distributions corresponding to these dosimeters have been compared with ionization chamber reference data for in-water on-axis relative depth dose distributions. Fricke gel dosimeters have been irradiated with an 18 MV photon beam from the Clinac 2100 C Varian linear accelerator (Linac). The employed beam field size was 10 cm 10 cm, with an isocentric technique, SSD 100 cm. The dosimeters have been irradiated inside a suitable tissue-equivalent phantom in order to ensure accurate dosimetric conditions. 3. Results and discussion The simplest incident spectrum considered for the simulations was a monoenergetic beam with half of the maximum of the bremsstrahlung spectrum, i.e. 9 MeV. Other simple incident beams tested have been suitable combinations of monoenergetic components, as the 2-delta example shown in Fig. 1. Fig. 2 shows the on-axis normalized depth dose distribution (PDD) results obtained with several simplified input incident spectra corresponding to a homogeneous water phantom. For the case of the 2-delta incident spectrum, equal intensities have been chosen for the 6 and 12 MeV photon beam components. On the other hand, Intensity (a.u.) 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0.00 Optimum Spectrum Two-delta (6 and 12 MeV) 0 2 4 6 8 10 12 14 16 18 Energy (MeV) Fig. 1. Optimal bremsstrahlung spectrum and 2-delta simple model for the Clinac 2100 C 18 MV photon beam as input for dose distribution simulations.

4 G. Castellano et al. / Nuclear Instruments and Methods in Physics Research A 5 (07) 2 5 PDD 100 90 MC1Delta MC2Delta MC3Delta IonChamb PDD 100 MC Water MC Fricke Gel Reference: Ionisation Chamber 0 5 10 15 25 Depth (cm) Fig. 2. Monte Carlo simulations for the normalized depth dose (PDD) corresponding to the several simplified delta spectra considered, as compared to the experimental distribution measured with an ionization chamber. 0 5 10 15 25 Depth (cm) Fig. 3. Comparison of simulated PDD for water and Fricke gel phantoms with reference data. weighted values have been used in the case of the 3-delta example with energies of 4.5, 9 and 13.5 MeV, with ratio 6:2:1, respectively. Clearly the depth dose distribution cannot be satisfactorily simulated with these simplified spectra. Particularly, when considering several energy components with appropriate intensities, the in-phantom simulated absorbed dose distribution becomes closer to the experimental one. With the aim of assessing the quality of the most adequate incident beam spectrum, a large number of different energy distributions, employing weighted monoenergetic lines combinations as well as continuous parameterized spectra, have been considered. Minimal squares were the adopted optimization procedure. When approaching the optimal incident spectrum differences are not distinguishable at first sight. Therefore, the measure chosen for quantifying the suitability of the obtained results has been a chi-square test, defining w 2 ¼ 1 N X N i¼1 ðy i ~y i Þ 2 s 2 i where y i and ~y i are the measured and simulated values, respectively, and s i represents the uncertainty of each of the N simulated values. By means of this tool, the optimal spectrum plotted in Fig. 1 has been achieved. Henceforth, in order to obtain accurate results, the simulations corresponding to the tissue-equivalence tests have been performed including the obtained optimal incident spectrum. The adapted MC code has been employed to the Fricke gel dosimeter tissue-equivalence study. The obtained onaxis depth dose distributions corresponding to Fricke gel dosimeter and homogeneous water phantoms are compared with ionization chamber measurements in Fig. 3. The obtained results evidence an on-axis tissue-equivalence (1) Transverse Side (pixel indexed) 0 10 10 10 0 10 between these materials. However, it is necessary to survey the entire in-phantom dose distributions for achieving a more reliable comparison. To this aim, central plane isodose curves have been determined for both materials, some of which are displayed in Fig. 4. Remarkable coincidences have been obtained for all isodose values. 4. Conclusion --- Water --- Fricke Gel The adapted code has shown to be a suitable tool for simulating in-phantom dose distribution in water and Fricke gel. The obtained results for the on-axis normalized depth dose distribution and the isodose curves may be considered as a first confirmation of the Fricke gel dosimeter tissue-equivalence. Depth (pixel indexed) Scale: 1cm:8pix Fig. 4. In-phantom MC central plane isodose curves for water and Fricke gel.

G. Castellano et al. / Nuclear Instruments and Methods in Physics Research A 5 (07) 2 5 5 Further developments will focus attention on variance reduction technique in order to save CPU time, as well as details of the accelerator components. Acknowledgments The authors are grateful to Istituto Nazionale per la Cura e Ricerca dei Tumori di Milano for allowing access to the facilities employed in this work, and to Royalite Plastics S.R.L. for the supply of polystyrene plates for phantom design. G.G., G.C. and M.V. acknowledge INFN for partial support this work. References [1] ICRU Report 24: Determination of absorbed dose in a patient irradiated by a beam of x or gamma rays in radiotherapy procedures, ICRU, Washington, 1976. [2] J. Cunningham, Progress in Medical Radiation Physics, vol. 1, Plenum, New York, 1982. [3] P. Keall, P. Hoban, Med. Phys. 23 (1996) 479. [4] F. Salvat, J. Fernández-Varea, J. Sempau, PENELOPE, A code system for Monte Carlo simulation of electron and photon transport, NEA France, 03. [5] G. Gambarini, C. Birattari, M. Mariani, R. Marchesini, L. Pirola, P. Prestini, M. Sella, S. Tomatis, Nucl. Instr. and Meth. B213 (04) 321. [6] G. Gambarini, D. Brusa, M. Carrara, G. Castellano, M. Mariani, S. Tomatis, M. Valente, E. Vanossi, J. Phys: Conf. Ser. 41 (06) 466. [7] M. Bero, W. Gilboy, P. Glover, J. Radiol. Prot. (00) 287.