Efficacy of ProTaper retreatment system in root canals filled with guttapercha and two endodontic sealers

Similar documents
Research Article Evaluation of Manual and Two-Rotary Niti Retreatment Systems in Removing Gutta-Percha Obturated with Two Root Canal Sealers

Comparative Analysis of Efficacy and Cleaning Ability of Hand and Rotary Devices for Gutta-Percha Removal in Root Canal Retreatment: An in vitro Study

Evaluation of retrievability using a new soft resin based root canal filling material

Comparison of the efficacy of three different techniques in the removal of gutta-percha and two types of sealers during endodontic retreatment

Evaluation of three different rotary systems during endodontic retreatment - Analysis by scanning electron microscopy

The effectiveness of a self-adjusting file to remove residual gutta-percha after retreatment with rotary files

Comparing the Efficacy of Mtwo and D-RaCe Retreatment Systems in Removing Residual Gutta- Percha and Sealer in the Root Canal

Effectiveness of rotary or manual techniques for removing a 6-year-old filling material

Staining Potential of Calcium Hydroxide and Monochlorophenol Following Removal of AH26 Root Canal Sealer

Comparison of Orange Oil and Chloroform as Gutta- Percha Solvents in Endodontic Retreatment

Last Generation Endodontic Instruments. A Study of their. Drs. Siragusa and Racciatti are affiliated with the Department of

EFFICACY OF NON-SURGICAL RETREATMENT WITH AND WITHOUT USING ULTRASONICS AND DENTAL MICROSCOPE

Influence of cervical preflaring on apical file size determination - An in vitro study

CBCT Evaluation of the Root Canal Filling Removal Using D-RaCe, ProTaper Retreatment Kit and Hand Files in curved canals

Safety and Simplicity!

Analysis of two different endodontic desobturation techniques through clearing teeth technique

In vitro evaluation of root canal preparation with plastic endodontic rotary finishing file - A SEM study

Comparative Analysis of Efficacy of Hand and Rotary NiTi Instruments in Gutta-percha /jp-journals

The Graduate School Yonsei University Department of Dentistry Myoungah Seo

Creating a glide path for rotary NiTi instruments: part two

Corresponding Author:Dr.Sneha Vaidya 3

Shah. Management of a maxillary second premolar with an S-shaped root canal - An endodontic. Management of a maxillary second premolar

Integra Miltex. Endodontic Files. Limit uncertainty with the brand you trust

Endodontics. Patented partial heat treatment Improved safety

ORIGINAL ARTICLE INTRODUCTION

Working length changes following straight-line access and different coronal flaring methods

INTERNATIONAL JOURNAL OF CURRENT RESEARCH IN CHEMISTRY AND PHARMACEUTICAL SCIENCES

PHD student. Department of Endodontics, Faculty of Medicine and Dentistry, University of Valencia, Spain 2

WaveOne Gold reciprocating instruments: clinical application in the private practice: Part 2

WHERE SAFETY MEETS EFFICIENCY

5/8/2012. Endodontics. Root Canal Preparation Root Canal Filling. Coronal Access. Isolation. Follow-up. Diagnosis

Case Report. July 2015; Vol. 12, No. 7. Vineet Agrawal 1, Sonali Kapoor 2, Mukesh Patel 3

Before we begin demonstrating the shock of paradigms on the instrumentation

Cleaning Efficiency of Nickel Titanium GT and.04 Rotary Files when used in a Torque Controlled Rotary Handpiece

in simulated curved canals

Introduction. IEJ Iranian Endodontic Journal 2017;12(2):

An in vitro comparative evaluation of a hand file and three rotary NiTi instruments for removing gutta percha during root canal re-treatment

Comparison of Spreader Penetration during Lateral Compaction of 0.04 and 0.02 Tapered Gutta-Percha Master Cones

Efficacy of reciprocating and rotary techniques for removing filling material during root canal retreatment

ENDODONTOLOGY. An in-vitro evaluation of apical sealing of three epoxy resin based commercial preparations INTRODUCTION MATERIALS AND METHODS ABSTRACT

Comparison of apical and coronal sealing in canals having tapered cones prepared with a rotary NiTi system and stainless steel instruments

A comparative scanning electron microscopic study of the effect of three different rotary instruments on smear layer formation

JCDP ABSTRACT INTRODUCTION /jp-journals

Comparison of canal preparation pattern of K3 and ProTaper rotary files in curved resin blocks

Field Guide to the Ultrasonic Revolution

Endo Easy Efficient. The efficient NiTi system. User Information.

RSBO Revista Sul-Brasileira de Odontologia ISSN: Universidade da Região de Joinville Brasil

Endo Easy Efficient one file endo

You succeed your root canal treatments! Characteristics...page 4. Instruments...page 6. Protocol...page 10. Questions & Answers...

Self-adjusting files in retreatment: a high-resolution micro-computed tomography study

A WHOLE NEW DIMENSION OF TOTAL PERFORMANCE.

A great file. Even better.

Instructions for use: FlexMaster. the rotary NiTi-System for every case. Endo Easy Efficient

Case Report Endodontic Management of Maxillary Second Molar with Two Palatal Roots: A Report of Two Cases

Endo Easy Efficient. one file endo. The RECIPROC Technique Steps to Success.

Celebrating 30th Anniversary of DiaDent Specialized GUTTA PERCHA & PAPER POINTS REFERENCE GUIDE

An In Vivo Evaluation of Two Types of Files used to Accurately Determine the Diameter of the Apical Constriction of a Root Canal: An In Vivo Study

Effective cleaning and shaping of the root

Endodontics. Lec.7 د. حسن الرماحي 5 th class. Obturation techniques

Efficacy of novel thermomechanically treated reciprocating systems for gutta-percha removal from root canals obturated with warm vertical compaction

Minimally Invasive Endodontics for Better and Safer Treatment

Case Report Endodontic Treatment of Maxillary Premolar with Three Root Canals Using Optical Microscope and NiTi Rotatory Files System

flexible performance Chemin du Verger 3 CH-1338 Ballaigues Switzerland

KING SAUD UNIVERSITY College of Dentistry. Department of Restorative Dental Sciences DIVISION OF ENDODONTICS COURSE OUTLINE 323 RDS

Comparison of Canal Preparation Pattern of K3 and ProTaper Rotary Files in Curved Resin Blocks

/jp-journals An in vitro Study to Compare the Effectiveness of F-file with Ultrasonically Activated K-file to Remove Smear Layer

XP-endo Shaper. The One to Shape your Success

Race family Endodontic NiTi rotary files

ENDO-EZE TM GENIUS ENDODONTIC SYSTEM WHERE SAFETY MEETS EFFICIENCY

Non-surgical endodontic treatment f invaginatus type III using cone bea Title tomography and dental operating mic report.

MDJ The effects of canal preparation by different NiTi rotary Vol.:9 No.:2 2012

Tools for Endodontic Success

A COMPARATIVE STUDY OF ROOT CANAL FILLINGS BASED ON WARM GUTTA-PERCHA CONDENSATION TECHNIQUES

Smear layer removal evaluation of different protocol of Bio Race file and XPendo Finisher file in corporation with EDTA 17% and NaOCl

In vitro Study of Apically Extruded Debris and Irrigant Following the Use of Conventional and Rotary Instrumentation Techniques

Comparison of Efficacy of Three Ni-Ti Instruments in Removal of Gutta-Percha from Root Canal during Retreatment- An In Vitro Study

XP-endo Finisher. 3D Generation

Comparison of the Different Techniques to Remove Fractured Endodontic Instruments from Root Canal Systems

3 4SHAPING PATH 1DIAGNOSTIC GLIDE CAVITY ACCESS

one file endo Endo Easy Efficient

Failure of ProFile instruments used with air, high torque control, and low torque control motors

EndoWave. Enhanced safety for root canal preparation. Thinking ahead. Focused on life.

Obturation of internally prepared cavities (simulating internal resorption) with three different techniques

Fauzia Ashraf, Pushpa Shankarappa, Abhinav Misra, Asheesh Sawhney, Nandamuri Sridevi, and Anu Singh

Failure of ProTaper rotary Ni-Ti instruments used by undergraduate students

Case Report. International Journal of Scientific Study. Abstract

ANATOMIC. XP-endo Finisher. optimal cleaning while preserving dentine

RSBO Revista Sul-Brasileira de Odontologia ISSN: Universidade da Região de Joinville Brasil

IN VITRO EVALUATION OF ROOT CANAL PREPARATION WITH TWO ROTARY INSTRUMENT SYSTEMS PRO TAPER AND HERO SHAPER

Removal efficiency of propolis paste dressing from the root canal

Influence of plugger penetration depth on the area of the canal space occupied by gutta-percha

1) INDICATIONS FOR USE These products have to be used only in hospital environments, clinics or dental offices by qualified dental personnel.

Comparison of Remaining Root Dentine Thickness After Three Rotary Instrumentation Techniques By Cone Beam Computerised Tomography-An Invitro study

5 Days Comprehensive Endodontic Course Topics

Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 1. Shaping ability in simulated curved canals

Shaping Potential of Manual NiTi K-File and Rotary ProTaper and Analyzing the Final Outcome of Shaped Canals using CT

Leakage along warm gutta-percha fillings in the apical canals of curved roots

Instruments used in Endodontics

UNICLIP DIRECTIONS FOR USE REF C226U - 0,8 MM / 1 MM FOR DENTAL USE ONLY. FISDR / F EN / 11 / updated 06/2016 1/7

A Shift Up In Performance. Performance Refined

Transcription:

www.pucrs.br/repositorio Efficacy of ProTaper retreatment system in root canals filled with guttapercha and two endodontic sealers Só MVR, Saran C, Magro ML, Vier-Pelisser FV, Munhoz M. Efficacy of ProTaper retreatment system in root canals filled with gutta-percha and two endodontic sealers. J Endod 2008; 34(10): 1223-5. PMID: 18793925 [PubMed - indexed for MEDLINE] http://dx.doi.org/10.1016/j.joen.2008.07.020 Journal of Endodontics (ISSN: 0099-2399) The PDF publisher version of this paper is not available in the PUCRS Institutional Repository because this is a RoMEO green journal (Archiving Policy: Can archive pre-print and post-print) but author cannot archive publisher's version/pdf. A versão PDF da editora não está disponível no Repositório Institucional da PUCRS porque este é um periódico classificado como RoMEO verde (Política de Arquivamento: Pode arquivar a versão preprint e postprint), mas o autor não pode arquivar a versão/pdf do editor.

Efficacy of ProTaper Retreatment System in Root Canals Filled with Gutta- Percha and Two Endodontic Sealers Marcus Vinícius Reis Só, DDS, MSc, PhD, Caroline Saran, DDS, Miriam Lago Magro, DDS, MSc, Fabiana Vieira Vier-Pelisser, DDS, MSc, PhD,, Marcelo Munhoz, DDS Department of Endodontics, University of Passo Fundo, Passo Fundo, RS, Brazil Department of Endodontics, Uningá, Caxias do Sul, RS, Brazil Department of Endodontics, University of Ribeirão Preto, Ribeirão Preto, SP, Brazil Corresponding Author: Dr Marcus Vinicius Reis Só E-mail address: endo-so@hotmail.com

Abstract This study evaluated the efficacy of ProTaper Universal rotary retreatment system and hand files for filling material removal during retreatment and the influence of sealer type on the presence of filling debris in the reinstrumented canals. The canals of 60 palatal roots of first molars were obturated with gutta-percha and either a zinc oxide eugenol based or a resin-based sealer and reinstrumented: G1, EndoFill/hand files; G2, AH Plus/hand files; G3, EndoFill/ProTaper; G4, AH Plus/ProTaper. Roots were cleaved and examined with an optical microscope, and the amount of filling debris on canal walls was analyzed on digitized images. There was no significant difference (P>.05) among the root canal thirds within each group. G3 presented significantly more filling debris than G1 in the cervical third (P =.04). In the middle third, G2/G3/G4 showed more debris than G1 (P =.03). The techniques were similar (P =.64) in the apical third. All groups presented filling debris in the 3 canal thirds after reinstrumentation. Key Words: Endodontic retreatment; endodontics; root canal filling

Introduction: When endodontic treatment fails, nonsurgical endodontic retreatment is often indicated as the first choice to eliminate or to substantially reduce the microbial load from the root canals. However, well-compacted filling material offers resistance to instruments, and incomplete removal of gutta-percha and sealer limits the access to the apical foramen and impairs root canal disinfection and reshaping. Several studies ( [1], [2], [3], [4], [5], [6], [7], [8], [9], [10], [11], [12], [13] and [14]) have reported that debris is left on canal walls after root canal retreatment, regardless of the type of instrumentation (hand or rotary), type of filling material, and use or not of solvents. Different rotary systems (Profile ( [1], [2], [5], [6], [7] and [15]), Quantec (15), GT Rotary (3), K3 ( [4], [6] and [12]), Protaper ( [3], [6], [10], [11] and [12]), and RaCe (10)) have been evaluated for root filling removal and root canal reinstrumentation. More recently, ProTaper nickel-titanium (NiTi) rotary system has been upgraded to the ProTaper Universal rotary system, which offers, in addition to shaping and finishing instruments, retreatment files designed specifically to remove obturation material from root canals. To date, few data are available about the behavior of ProTaper Universal retreatment instruments in endodontic retreatment (16). Therefore, this in vitro study evaluated comparatively the efficacy of the ProTaper Universal (Tulsa Dental, Tulsa, OK) rotary retreatment system and hand files for removal of filling material during root canal retreatment and the influence of the type of sealer on the presence of filling debris in the reinstrumented canals. Material and Methods Specimen Selection Sixty maxillary first molars were radiographed and selected if they had a palatal root with a single straight canal (or curvature <5 degrees) and fully formed apex. The apical 16 mm of the palatal roots was sectioned for use to standardize canal length in all teeth. Initial Endodontic Treatment The canals were prepared according to a crown-down technique with Flexofile hand files (21 mm, 1st/2nd series; Dentsply/Maillefer, Ballaigues, Switzerland). The cervical and middle thirds were preflared with Gates-Glidden drills sizes 2 and 3 (Dentsply/Maillefer). Briefly, each canal was negotiated with a size 15 file until its

tip was visible at the apical foramen, and the working length (WL) was established 1 mm short of canal length (15 mm). The apical stop was prepared with a size 30 file. Canals were irrigated with 1 ml 1% NaOCl at each change of file. When instrumentation was completed, the canals were filled with 17% ethylenediaminetetraacetic acid during a period of 3 minutes, flushed with 1% NaOCl, dried with absorbent paper points, and obturated with lateral compaction of thermoplasticized gutta-percha and either a zinc oxide eugenol (ZOE) based sealer (Endofill; Dentsply Ind e Com Ltda, Petrópolis, RJ, Brazil) or a resin-based sealer (AH Plus; Dentsply De Trey GmbH, Konstanz, Germany). Sealers were taken to the canals with the master gutta-percha cone, which was coated and inserted in a single movement. The quality and apical extent of root fillings were confirmed radiographically. The specimens used in this experiment had wellcompacted fillings extending to 1 mm short of the apex. The access cavities were sealed (Coltosol; Coltene-Whaledent, Cuyahoga Falls, OH), and the roots were stored in artificial saliva at 37 C for 3 months. Endodontic Retreatment Thirty roots had their canals (15 filled with gutta-percha/endofill [G1] and 15 with gutta-percha/ah Plus [G2]) emptied and reinstrumented with hand files. Gates- Glidden drills sizes 3 and 4 were first used at the cervical and middle thirds, and the filling mass was penetrated with a size 60 Hedström file (Dentsply/Maillefer) followed by sizes 55, 50, 45, and 40, until the WL was reached with a size 35 or 30 file. The apical third was enlarged up to a size 45 Flexofile hand file. The other 30 roots had their canals (15 filled with gutta-percha/endofill [G3] and 15 with gutta-percha/ah Plus [G4]) emptied with the ProTaper Universal NiTi rotary retreatment files and reinstrumented with ProTaper Universal NiTi rotary shaping and finishing instruments, following manufacturer's instructions. Root fillings were removed by using the D1, D2, and D3 retreatment files, which have a convex cross section with taper/tip diameter of 0.09/0.30, 0.08/0.25, and 0.07/0.20 mm, respectively. D1, D2, and D3 files were activated by an electric engine (Endo-Pró, Driller, São Paulo, SP, Brazil; 3 N/cm torque, 500 rpm speed) and used with a brushing action in a crown-down manner at the cervical, middle, and apical canal thirds, respectively, until reaching the WL. When 1 mm of filling material was left apically, the final canal portion was negotiated by using sizes 15 and 20 files with 1% NaOCl. Canal refinement was accomplished with the shaping (S1 and SX in the cervical third and S2 in the middle third) and finishing instruments (F1, F2, and F3 up to WL) at 2 N/cm torque and 250 rpm speed. No solvent was applied so that the sealers did not have their removal affected by solvent use. For both techniques, the canals were irrigated with 1% NaOCl between files, filled with 17% ethylenediaminetetraacetic acid after reinstrumentation, and flushed again with 1% NaOCl. Analysis of Filling Debris

The roots were grooved longitudinally in a buccolingual direction with a diamond disk and split into halves with a chisel. The root half with greater amount of filling debris on visual inspection was examined with an operative clinical microscope at 10 magnification (DF Vasconcellos, São Paulo, SP, Brazil). Images were captured with a digital camera (Nikon-Colpix, Tokyo, Japan) coupled to the microscope and analyzed with AutoCAD 2004 software (Mechanical Desktop Power Pack; Microsoft, Redmond, WA). Canal walls and filling debris were identified on the basis of the difference of radiopacity. A single operator used a specific software tool to outline the canal area and the filling debris area in each third (cervical, middle, and apical), as well as the total canal area. The filling debris area/canal area ratios were considered for statistical analysis and expressed as percentage of filling material left after reinstrumentation. Data were analyzed by Kruskal-Wallis test and Student-Newman-Keuls test for multiple comparisons at P<.05. First, statistics compared the canal thirds within each group; next, the groups were compared in each canal third; finally, intergroup comparison considered the total canal area to calculate the filling debris area/canal area ratios. Results Table 1 presents the filling debris area/canal area ratios obtained in the 3 canal thirds for the studied groups. Table 2 compares the groups regarding the filling debris area/canal area ratios in each canal third. G3 presented significantly more filling debris than G1 in the cervical third (P =.04). In the middle third, G2, G3, and G4 showed more debris than G1 (P =.03). The techniques did not differ significantly (P =.64) in the apical third. Filling debris area/canal area ratios for the total canal area in each group are presented in Table 3. TABLE 1. Filling Debris Area/Canal Area Ratios (%) in the Cervical, Middle, and Apical Thirds for the Different Groups Cervical Third Middle Third Apical Third P Value G1 0.034322 (0.064183) 0.049115 (0.104533) 0.092614 (0.14312).05 G2 0.052692 (0.061595) 0.091637 (0.116722) 0.092614 (0.14312).63 G3 0.205882 (0.247242) 0.148637 (0.159277) 0.136439 (0.191388).79 G4 0.223936 (0.298752) 0.166132 (0.150775) 0.157621 (0.165576).95 Values expressed as means (standard deviations). Statistically significant difference if P<.05 (Kruskal-Wallis test). TABLE 2. Intergroup Comparison Regarding Filling Debris Area/Canal Area Ratios in Each Root Canal Third Third Group P Value Cervical G3 > G1.04 Middle G2, G3, and G4 > G1.03

Discussion Third Group P Value Apical G1 = G2 = G3 = G4.64 Statistically significant difference if P<.05 (Kruskal-Wallis test). TABLE 3. Filling Debris Area/Canal Area Ratios (%) for the Total Canal Area in Each Experimental Group G1 G2 G3 G4 0.048311 a 0.078681 a,b 0.157667 b 0.160895 a,b (0.080741) (0.0494) (0.167058) (0.155456) Values expressed as means (standard deviations). Different superscript letters indicate statistically significant difference at 5% significance level (Kruskal-Wallis test). In endodontic retreatment, it is consensual that accurate removal of gutta-percha and sealer followed by adequate canal reinstrumentation provides better access to the necrotic tissue remnants and microorganisms causing persistence of periapical inflammation. However, previous studies have found that completely clean canal walls were not produced with any of the techniques investigated ( [5], [7], [8] and [12]). Likewise, in the present study, filling debris was found in all cleaved canals after endodontic retreatment with both hand files and ProTaper Universal system. In the cervical third, significant differences were observed between hand and rotary instrumentation in canals filled with the ZOE-based sealer. Canals emptied and prepared with rotary instruments left more gutta-percha and Endofill debris than those reinstrumented with hand files (P =.04). The cervical third was the most critical for ProTaper retreatment. However, cleanliness in the cervical and middle thirds of G1 and G2 was more likely due to the action of the Gates-Glidden drills than the hand files because the kinematics of these drills pushes the filling material out of the root canal. In the middle third, hand reinstrumentation of canals filled with Endofill left less filling debris than rotary instrumentation associated with Endofill or AH Plus and hand files associated with AH Plus (P =.03). In the same way as reported by Zmener et al. (7), more filling debris was left in the middle third of canals reinstrumented with rotary instruments. Kosti et al. (5) observed a greater amount of resin-based sealer (AH 26) in the middle third, although without significant difference between the rotary and hand techniques for this type of sealer. It might be speculated that because resin-based sealers have better adhesion to dentin walls, their removal from root canals with rotary instruments is more difficult. The manufacturer of the ProTaper Universal system contraindicates its use in root canals filled with these sealers, which might help explain the presence of more filling debris in G3/G4. The apical root canal third is a critical area for cleaning, shaping, and filling procedures. In terms of case prognosis, the real impact of the presence of debris after filling material removal and reinstrumentation of infected canals remains

unclear. In the present study, regardless of the technique and sealer, this region of the canal presented filling material remnants, although without significant differences (P =.64) among the groups. Because G1/G2 were prepared to an apical diameter of around 0.45 mm and G3/G4 of around 0.30 mm, cleaner apical canal sections would be expected in both manually instrumented groups. However, it was not observed in the present study, perhaps because the great taper of the F3 instrument (taper 0.09) determines a diameter of 0.39 and 0.48 mm at 1 and 2 mm from its tip, respectively, approaching the diameter of size 45 hand files at these distances. It should also be considered that hand files can be precurved and directed to the regions in which the tactile sensation indicates the presence of filling material. Therefore, the combined use of hand and rotary instruments appears to be a good option to improve apical cleaning. A previous ex vivo study (7) evaluating retreatment efficacy of hand versus automated instrumentation did not find differences between rotary/oscillatory instruments and hand files in the apical third. Masiero and Barletta (4) justified the fact that rotary instrumentation (K3 system) promoted better apical cleaning compared with other techniques because the shape of canals reinstrumented with the K3 system was similar to the original canal section. In the present study, rotary instrumentation was not more effective than hand files in the apical third, where the canal section tends to be circular. Regarding the total canal area, differences between the techniques were observed only when the ZOE-based sealer was used; more filling debris was found when ProTaper Universal System was used (P =.002). Most studies did not detect differences between hand and rotary instrumentation with different sealers considering the total canal area ( [11] and [12]), possibly as a result of nonuse of solvent. Although the findings of the present study are consistent, extrapolation to the clinical condition should be done with care. Further research is necessary for this system to be used in a safer and more effective manner for endodontic retreatment. The following might be concluded (1). Debris was left in all canal thirds, regardless of the retreatment technique (2). The greatest differences between techniques and sealers were found in the middle third, with less amount of debris in canals obturated with Endofill and reinstrumented with hand files (3). The techniques had similar cleaning efficacy in the apical third, regardless of the sealer. References 1. V. Sae-Lim, I. Rajamanickam, B.K. Lim, H.L. Lee. Effectiveness of Profile.04 taper rotary instruments in endodontic retreatment. J Endod, 26 (2000), pp. 100 104 2. K.M. Barrieshi-Nusair. Gutta-percha retreatment: effectiveness of nickel-titanium rotary instruments versus stainless steel hand files. J Endod, 28 (2002), pp. 454 456

3. M. Hülsmann, V. Bluhm. Efficacy, cleaning ability and safety of different rotary NiTi instruments in root canal retreatment. Int Endod J, 37 (2004), pp. 468 476 4. A.V. Masiero, F.B. Barletta. Effectiveness of different techniques for removing gutta-percha during retreatment. Int Endod J, 38 (2005), pp. 2 7 5. E. Kosti, T. Lambrianidis, N. Economides, C. Neofitou. Ex vivo study of the efficacy of H-files and rotary Ni-Ti instruments to remove gutta-percha and four types of sealer. Int. Endod J, 39 (2006), pp. 48 54 6. A.C.C. Maciel, M.F.Z. Scelza. Efficacy of automated versus hand instrumentation during root canal retreatment: an ex vivo study. Int Endod J, 39 (2006), pp. 779 784 7. O. Zmener, C.H. Pameijer, G. Bonegas. Retreatment efficacy of hand versus automated instrumentation in oval-shaped root canals: an ex vivo study. Int Endod J, 39 (2006), pp. 521 526. 8. J.F. Schirrmeister, P. Hermanns, K.M. Meyer, F. Goetz, E. Hellwig. Detectability of residual Epiphany and gutta-percha after root canal retreatment using a dental operating microscope and radiographs: an ex vivo study. Int Endod J, 39 (2006), pp. 558 565 9. J.F. Schirrmeister, K.M. Meyer, P. Hermanns, M.J. Altenburger, K.T. Wrbas. Effectiveness of hand and rotary instrumentation for removing a new synthetic polymer-based root canal obturation material (Epiphany) during retreatment. Int Endod J, 39 (2006), pp. 150 156 10. J.F. Schirrmeister, K.T. Wrbas, K.M. Meyer, M.J. Altenburger, E. Hellwig. Efficacy of different rotary instruments for gutta-percha removal in root canal retreatment. J Endod, 32 (2006), pp. 469 472 11. R. Gergi, C. Sabbagh. Effectiveness of two nickel-titanium rotary instruments and a hand file for removing gutta-percha in severely curved root canals during retreatment: an ex vivo study. Int Endod J, 40 (2007), pp. 532 537 12. A.Y. Saad, S.M. Al-Hadlaq, N.H. Al-Katheeri. Efficacy of two rotary NiTi instruments in the removal of gutta-percha during root canal retreatment. J Endod, 33 (2007), pp. 38 41. 13. X. Huang, J. Ling, X. Wei, L. Gu. Quantitative evaluation of debris extruded apically by using Protaper Universal Tulsa rotary system in endodontic retreatment. J Endod, 33 (2007), pp. 1102 1105

14. F. Somma, G. Cammarota, G. Plotino, N.M. Grande, C.H. Pameijer. The effectiveness of manual and mechanical instrumentation for the retreatment of three different root canal filling materials. J Endod, 34 (2008), pp. 466 469 15. N. Imura, A.S. Kato, G.I. Hata, M. Uemura, T. Toda, F. Weine. A comparison of the relative efficacies of four hand and rotary instrumentation techniques during endodontic retreatment. Int Endod J, 33 (2000), pp. 361 366 16. L.S. Gu, J.Q. Ling, X. Wei, X.Y. Huang. Efficacy of ProTaper Universal rotary retreatment system for gutta-percha removal from root canals. Int Endod J, 41 (2008), pp. 288 295